You are on page 1of 9

APLICANDO EL MÉTODO DE NASH

PERIODOS DE RETORNO 10, 25, 50 Y 100 AÑOS

CAUDALES MAXIMOS
Año (1) Caudal m³/s
(2)
1982 183.6
1983 81.2
1984 292.87
1985 129.7
1986 115
1987 105
1988 71.27
1989 178.46
1990 24.34
1991 102.49
1992 14.86
1993 129.32
1994 189.02
1995 303.68
1996 124.62
1997 26.49
1998 280
1999 414.34
2000 287.32
2001 204.31
2002 119.13
2003 130.96
2004 159.34
2005 35.6
2006 156.2
2007 43.09
2009 102
2010 98.39
2011 180.73
2012 304.04
2013 177.78
2014 82.99
Solución:

1.- Ordenando en forma descendente, los valores de los caudales maximos.

CAUDALES MAXIMOS ANUALES DE LA CUENCA


DOÑANA (m³/s)
CAUDALES ANUALES (m³/s)
AÑO CAUDAL ORDENADO
(m³/s) MAX.
1982 183.6 414.34
1983 81.2 304.04
1984 292.87 303.68
1985 129.7 292.87
1986 115 287.32
1987 105 280
1988 71.27 204.31
1989 178.46 189.02
1990 24.34 183.6
1991 102.49 180.73
1992 14.86 178.46
1993 129.32 177.78
1994 189.02 159.34
1995 303.68 156.2
1996 124.62 130.96
1997 26.49 129.7
1998 280 129.32
1999 414.34 124.62
2000 287.32 119.13
2001 204.31 115
2002 119.13 105
2003 130.96 102.49
2004 159.34 102
2005 35.6 98.39
2006 156.2 82.99
2007 43.09 81.2
2009 102 71.27
2010 98.39 43.09
2011 180.73 35.6
2012 304.04 26.49
2013 177.78 24.34
2014 82.99 14.86
Según tabla se tiene la organización de Caudales para el calculo con el metodo de Nash

2.- Calculos Preliminares

m (1) CAUDALES (m³/s) T (3) T/(T-1) (4) X (5) Q*X (6) Q2 (7)
1 414.34 33.00 1.03 -1.8741 -776.50 171677.6356
2 304.04 16.50 1.06 -1.5662 -476.19 92440.3216
3 303.68 11.00 1.10 -1.3831 -420.01 92221.5424
4 292.87 8.25 1.14 -1.2509 -366.36 85772.8369
5 287.32 6.60 1.18 -1.1466 -329.43 82552.7824
6 280.00 5.50 1.22 -1.0597 -296.72 78400
7 204.31 4.71 1.27 -0.9849 -201.22 41742.5761
8 189.02 4.13 1.32 -0.9187 -173.66 35728.5604
9 183.60 3.67 1.38 -0.8592 -157.74 33708.96
10 180.73 3.30 1.43 -0.8047 -145.43 32663.3329
11 178.46 3.00 1.50 -0.7543 -134.61 31847.9716
12 177.78 2.75 1.57 -0.7071 -125.71 31605.7284
13 159.34 2.54 1.65 -0.6626 -105.57 25389.2356
14 156.20 2.36 1.74 -0.6202 -96.88 24398.44
15 130.96 2.20 1.83 -0.5796 -75.91 17150.5216
16 129.70 2.06 1.94 -0.5405 -70.10 16822.09
17 129.32 1.94 2.06 -0.5025 -64.99 16723.6624
18 124.62 1.83 2.20 -0.4654 -58.00 15530.1444
19 119.13 1.74 2.36 -0.4290 -51.11 14191.9569
20 115.00 1.65 2.54 -0.3930 -45.20 13225
21 105.00 1.57 2.75 -0.3572 -37.51 11025
22 102.49 1.50 3.00 -0.3214 -32.94 10504.2001
23 102.00 1.43 3.30 -0.2852 -29.09 10404
24 98.39 1.38 3.67 -0.2485 -24.45 9680.5921
25 82.99 1.32 4.13 -0.2108 -17.50 6887.3401
26 81.20 1.27 4.71 -0.1717 -13.94 6593.44
27 71.27 1.22 5.50 -0.1306 -9.30 5079.4129
28 43.09 1.18 6.60 -0.0864 -3.72 1856.7481
29 35.60 1.14 8.25 -0.0379 -1.35 1267.36
30 26.49 1.10 11.00 0.0176 0.47 701.7201
31 24.34 1.06 16.50 0.0855 2.08 592.4356
32 14.86 1.03 33.00 0.1814 2.70 220.8196
SUMATORIA 4808.94 -19.3345 -4340.68 1017793

3.- Calculo del Qm y Xm


Qm= 150.28 m3/s
Xm= -0.6042

4.- Calculo de los Parametros a y b;

b= -199.30
a= 29.86

5.- Calculo del Caudal Maximo.

T= 10 años Qmax= 296.83 m3/s


T= 25 años Qmax= 378.90 m3/s
T= 50 años Qmax= 439.78 m3/s
T= 100 años Qmax= 500.21 m3/s

6.- Calculo de las desviaciones estandar y covarianza

Sxx= 192.66
Sqq= 7407889.45
Sxq= -37242.26

7.- Calculo del Intervalo de Confianza

El valor de X se calcula para cada periodo de retorno

T= 10 años X= -1.3395
T= 25 años X= -1.7513
T= 50 años X= -2.0568
T= 100 años X= -2.3600
T= 10 años ∆Q= 48.41 m3/s
T= 25 años ∆Q= 47.15 m3/s
T= 50 años ∆Q= 46.20 m3/s
T= 100 años ∆Q= 40.16 m3/s

8.- Calculo del Caudal de Diseño

T= 10 años Qd= 345.24 m3/s


T= 25 años Qd= 426.05 m3/s
T= 50 años Qd= 485.98 m3/s
T= 100 años Qd= 540.37 m3/s
X2 (8)
3.5121
2.4530
1.9129
1.5648
1.3146
1.1230
0.9700
0.8441
0.7382
0.6475
0.5689
0.5000
0.4390
0.3847
0.3360
0.2922
0.2525
0.2166
0.1840
0.1545
0.1276
0.1033
0.0814
0.0618
0.0444
0.0295
0.0170
0.0075
0.0014
0.0003
0.0073
0.0329
18.8828

You might also like