You are on page 1of 12
Addendum for Mode! 250 This manual is applicable to units bearing serial numbers above 3500 and is the serve as the manual for units below that serial number except For the followir Throughout the original manual, replace “A, "B’ "Channel A” and “Channel B” with "L”, "R”, Channel" and "R Channel”, respectively. Pages 2 — Replace Figure 1. (Amplifier Simpli- and 3 fied Schematic) with Figure 1. con- tained herein. Page 4 — Replace Figure 2. (Rectifier/Relay Board Simplified Schematic) with Fig- ure 2. contained herein. Page4 ~ Reploce Figure 3. (250 Metering Cir- cuit Simplified Diagram) with Fig- ure3. contained herein. PageS — Replace 100, 220-VOLT AC CON- VERSION with: 220-VOLT AC CONVERSION To convert the Model 250 to 220-volt operation, perform the fotiowing steps: 1, Remove the top cover. 2. Orient the Model 250 so that the tear panel is facing toward the viewer, 3, Locate TB1, the strip located on the power transformer half shell facing the rear panel, which ter- minates the power transformer primary wires, 4, Unsolder all jumpers from TB1. 5. Solder a jumper (18 AWG) to TB1 connecting the grey and violet transtormer wires. 6. _Reattach the top cover. 7. Replace the 6-amp, 250V fuse in the unit with the'4-amp, 250V fuse, Part #451-1003, supplied with the 220-volt conversion kit, Part #105-1007-1. 8, Affix labels, supplied in conver- sion kit, in the appropriate loca- tions on the unit cover, and ad- jacent to the line cord, fuse holder and accessory outlets. ‘The Model 250 is now ready for 220- volt operation, 100-VOLT AC CONVERSION To convert the Model 250 to 100-volt operation, follow the procedure out- lined for '220-volt conversion except for items 4, 5, 7 and & Item 7 is eliminated. These items will read: 4, Unsolder the black and white power lead-in wires and all jumpers from T81. 5. Solder two jumpers (18 AWG) to TB1, one connecting the orange and violet transformer wires, and one connecting the grey and white transformer wires. Solder the black and white power lead-in wires to the white and orange transformer wires, re spectively, at TBI. 8. Affix labels, supplied in the 190- volt conversion kit, Part #105: 1008-1, in the appropriate loca- tions on the unit cover, and ad jacent to the line cord and ac: cessory outlets. The Model 250 is now ready for 100- volt operation. In Table |, for “AC Power Control Box,” replace “Fabricate in accord: ance with Figure 3.” with “Fabricate in accordance with Figure 4.”; for “Amplifier Output Load Box,” replace “Fabricate_ in accordance with Fig ure 4.” with “Fabricate in accordance with Figure 8.” In “PERFORMANCE VERIFICATION TEST PROCEDURE,” replace as indicated Page 7 — Page 8 — In paragraph C. (DC Balance Test), sub-paragraph 3. — Replace “R504” with “R502.” Page 8 — In paragraph D. (Total Hum and Noise Test), sub-paragraph 2 — Replace "0.25 mv" with "0.2 mv." Page 8 — In paragraph E.(Bias Adjustment Test), sub-paragraph 6 — Replace “10 watts” with "7 watts.”” Page 8 — In paragraph E.(Bias Adjustment Test), sub-paragraph 7 — Replace “R536” with R526” and replace “10 watts” with "7 watts.”” In paragraph F. (Maximum Power Out- put), sub-paragraph 7 — Replace “analyzer” with “oscillator.” PageQ — Page 9 — Page 9 — Page 10 — In paragraph G. (Relay Operation), sub-paragraph 1 — Replace "2 min- utes’ with "30 seconds.” In paragraph G. (Relay Operation), sub-paragraph 3 — Add “Drive both channels.” Replace Figure 4. (AC Power Control Box Simplified Schematic) with Fig ure 4. contained herein. In “TROUBLE ANALYSIS,” replace as indicated Page 11 — Page 11 — Page 11 — Page 11 — In SYMPTOM 1. — Replace "(100 watts or more)" with "(80 watts or more}. In SYMPTOM 1. PROCEDURE b. — Replace “Check for open control R224, 215-1005-1 bias assembly" with “Check for open 215-1006-1 bias assembly.” In SYMPTOM 5.- Add PROCEDURE c — "Check C502 for leakage.” la SYMPTOM 7. — Replace PROCE- DURE a. with “Check for defective C505, C506, C508, C509, C510, C516, €519 and C520.” Page 12 — Page 12 — Pages 13 ~ and 14, Page 15 — Page 17 — Pages 18 — and 19 In SYMPTOM 9. — Replace PROCE- DURE b. with “Check output for Proper ctipping into 4 ohm load with 25.8 volts AC ovtaut (positive and negative levels must not vary more than 1 volt at 2 KHz).” Add SYMPTOM 11. — “No Output’* and add PROCEDURE a. “Check 529, 0510, Q511, 802, 803, 0804’ and A805. PARTS LIST — The Parts List con- tained herein identifies ali parts which differ from those used in units arior to serial number 3601 Replace Figure 7. (Power Amplifier Board Component Assembly Diagram) with Figure 7, contained herein, Replace Figure 9. (Meter Board Com- ponent Assembly Diagram) with Fig- ure 9. contained herein Replace Figure 10. (Model 250 Sche- matic) with Figure 10. contained herein, Rsi7 ows L ran tl + Ho 3 ws Oe | YY {— tC) t A516 ¢ Ne S18 FIGURE 1. Amplifier Simplified Schematic, 527758) 10 RecriFieR RELAY SORRD Cvoc y!)___sgge ' aseK v0. reese FIGURE 2, RECTIFIER/RELAY BOARD SIMPLIFIED SCHEMATIC 2xamp — VARIAC sLo-8Lo [VARIABLE] (wonmay] prRecT| AC OUTLETS ON, * 105 TO 125 VAC 80/60 Hz o o ° o AC WATTMETER AC VOLTMETER, [0 TO 300 WATTS: OT 150 VAC FIGURE 4— AC POWER CONTROL BOX SIMPLIFIED SCHEMATIC PARTS LIST Reference Description Marantz || Reference Description Marantz Designetion | and/or emerks | Part Number] | Designaticm andior Remarks | Part Number HEATSINK ASSEMBLY 511} Transistor, PNP 461-1046." 0505 | Cap., 36 pf.26%, 100v | 385-1068 516 NPN 1462-1035." 6508 | Cap., 47 pf.+10%, 100v. | 385-1040 asi? "pnp 461-1030." 512 | Cap., 1000 pf. +10%, 100v] 985-1068 0520] Transistor, NEN 1462-1000 se 6918 | (Wor Used! 802 | Cap.,0.1yf, =t0%, 250v | 386-1000 512 | Cop.,0.1 pt, £10%, 250V | 986-1000 520 | Cop., 6800 vf, +10%, 400v] 986-1026 crB01 | WNot Used R803. | Diode 460-1011 0801 | Transistor, NPN (contained) 462-1043 R501 | Res. C/F,4.7K.25%, | aag.4a72 in 218-1008-1 Heat Sensor 1120 Aso) 508 | Res..C/F, 91K, 25%, 434.5912 0802 | Transistor, PNP 461-1031" vaw 0803 | Transistor, NPN 462-1036" R526 | Res., Variable, 250 ohms, | 420-1026 0804 | Transistor, PNP 461-1031." aw " 0805 | Transistor, NPN 462-1036." 529. | Res, C/C, 39 ohms, =10%,| 423-2399 iw METER BOARD R590 | Res.,C/C, 99 ohms, =10%, | 423.2903 ww 292 ‘COMPONENT ASSEMBLY R852 | Res. C/C,5.6 ohms, 423-1562 25%, 1W R431 | Res., C/F, 22K, 45%, aw | 494-6222 553 | Res.,C/C,5.6 ohms, 429-1562 rage | Res, CIF, 24K, 25%, aw] 434-4242 ee Rasa | Ros., CF, 22K, 25%, 1/4w | 4345222 REG | Bos CIF, 10K. 25%, #945102 R434 | Res. C/F, 24K, +6%, 14] 434-4242 1555 | Res, C/F, 470 ohms, 434.3472 5%, 1/4W MISCELLANEOUS PARTS 556 | Res,,C/F, 75 ohms, 434.2782 25%, 1/4W 1 Transformer, Power | 440-1010-1 557 | Res. C/F, 10 0hm, 433-2102 25%, 1/2W Ri (Not Used) Re (Not Used) 0501 | Transistor, NPN 462:1038.2 0502 | Transistor, NEN 462-1038-2 Front Panel 134-1031-1 0507 | Transistor, PNP 461-1087." 0508 | Transistor, NPN 462-1053" |] mma | Meter 1865-1002 0510 | Transistor, NPN 462-1084." “For applicable dash qumber, se transistor specification chart on unit schematic (Figure 10) FIGURE 9 ~ METER BOARD COMPONENT ASSEMBLY DIAGRAM

You might also like