Removing the ETB Unit

<Preparation>

1. Pull out the Fixing Feed Unit.

1-1) Open the Front Cover.

1-2) Turn the Fixing Feed Unit Pressure Release Lever in the direction of the arrow to pull out the Fixing
Feed Unit.

1-3) Push to release the Release Springs at both sides of the Rail, and then further pull out the Fixing
Feed Unit until it stops.
CAUTION:

Do not touch the surface of the ETB when handling the ETB Unit.

<Procedure>

1) Remove the Fixing Feed Right Front Upper Cover.

1 Screw
2) Hold the 2 Handles to remove the ETB Unit in the direction of the arrow.

<Processing when replacing the parts>

1) Clear the ETB control counter. (COPIER>FUNCTION>CLEAR>TR-BLT)


Parts counter (COPIER>COUNTER>DRBL-1>TR-BLT) is also cleared coincidentally.