¢ pre inpaul.com Ss rejinpaul.info
Grow wien Us Ye Grow With Us
All The best For Exams - Rejinpaul Team
‘Anna University Exams April/May 2015 — Regulation 2008
Rejinpaul.corn Unique iniportant Questions 6th Semester'BE/BTECH
E2352 — DESIGN OF STEEL STRUCTURES.
Unit 4
1. Explain the various steps involved to the welded in a structural design processes.
2._ Explain the design principle of welded joint for a single unequal angle connected to a gusset plate
3. A6mm thick angle section Is subjected to a 10mm thick guessed plate the angle is supporting a load
of 60kn find out the number of 16mm diameter of rivet.
4. An équal angle 75mmx75mm @11.Oke/Mm Is subjected'to a load of 180kn, whose line of action
passed thought the centroid of the section which is at 22.2mm from the hell this angle is to be
welded to a(guessediplate if the sizeof the weld Is to.be mm, find the length of fillet welded.
5. Adouble riveted lap joint in plates 10mm tk is made with 16mm rivets at 60mm pitch. Estimate how
the joint will fail and calculate its efficiency if the tearing strength of the plate is 475n/mm2 and
shearing and bearing strength of the rivets are 380n/mm?2 and 750n/mm2 respectively.
6. Adouble riveted double cover butt joint is used to connect plates 12 Mm thick. Using Un
formula, determine the diameter of rivet; rivet value, gauge and efficiency of joint,
Unit It
1. Design of double angle tension members carrying a axial.tension load of 300kn,.In addition to this it
is also subjected to a udl of 0.4kn/m through its length including self wt. centre to centre distance is
2.7m
2.) Desigh’a double angle discontinuous strutito carry 250 KN load. Effective length of member is 3.00
m. Use equal angles placed back-to-back at opposite faces of the gusset plate 10 mm thick.
3., A diagonal member of the roof carries. max.ayial load-of 300kn design the section and the
connecting with 14mm gassed plate the length of the gusset plate available for making the
connection is 310mm design the angle also required the steel of yield stress isty250n/mm2.
4, Design the tension strength of 6 Yoof truss diagonal 100 X 75 X 10 mnv’eonnectedto the gusset plate
by 20 mm diameter power driven rivets in one row along the length of the member. The short leg of
‘the angle is kept outstanding
5, A tension members is subjected to a pull of 300kn.design suitable section if (iJit consists of a single
angle connected by one leg. {iit consistiof double angle on elther side of gusset plate,
6. A tie members in a roof truss consist of two ISA90x60x8mm determine the safé load carrying
capacity of the members if i. The angle are on the same side of the gusset plate ji. The angle are
either side of the gusset plate. 16mm rivets are used.
Unit itl
4. Design a.colurhn to,carry an axial load of1250 kn.the length of column is 4,5m and itis restrained at
both ends
2. design complete a buit up column composed of channel section placed back to back and carrying
axial load of 1500kn,its length is 6m and itis effectively held in positional both ends and restrained
against rotation at one ends take fy 250n/mm2
3. 8. A discontinues strut consists of two ISA 90X75X10mm placed to the same side of a gusset plate
10mm thick with its longer leg back to back, with one rivet on each angle at the ends. The effective
indsGrow With Us
rejinpaul.com <>. rejinpaul.info
a gga @pier
All The best For Exams - Rejinpaul Team
length of the strut is 2.5m.Determine the allowable load. What is the safe load if the strut is
continuous? Take fy = 250N/mm2. The arigleé até connected with tack rivets along thellength.
4. Design of double angle tension members carrying a axial tension load of 350kn. In addition to thi
js also subjected to audi of 4kn/m through its length including self wt. centre to,centre distance is
2.5m.
5, State step by step procedure of designing of ver
‘Unit IV
1. Design a bearing stiffener for a welded plate girder with the followingspecifications. Web = 1000mm
X/6rnm thick, Flanges = 2 Nos: of 350X20min plate on each'side. Support reaction = S50kN.Width of
the support = 300mm.
2. Design the step by step procedure for design of vertical and horizontal stiffeners in plate girder.
3. Asimply supported steel joist with a 4.0m effective span carries audl of 40kN/mover its span
inclusive of self weight. The. beam is laterally unsupported. Design suitable section. Take fy =
250N/mm2.
Awelded plate girder has (i) each top bottom flange 435x28mm|
and horizontal stiffeners.
5. Design a beam of 6m span carries a udl of 30kn/m and two concentrated load of 25kn each at 2m
from either support the depth of section Is restricted to 350mm assume the compression of flange is
unrestrained laterally.
| and horizontal stiffeners in a Plate girders.
Web 1250x10mm design vertical
Unit V
1. Desigh’a gantry girder to ba Used in an’mill building carrying an electric over/head travelling crane
for the following data: Crane capacity = 300 kN. Total self weight of all components = 30 kN.
Minimum approach at the carne hook of gantry girder = 1.2m Wheel base = 3.5m C/C distance
between gantry rails = 18m C/C distance between columns = 8m Self weight of rail section = 130
N/m Determine: Max.BM and SF produced by the vertical load. Max.BM and SF praduced by the
horizontal oad. The max.longitudinal force exerted along the crane.
2. State design steps of a roof truss member wise in brief. Answer should contain design loads
3./ Determine the dead Joad, live load and wind load'on a FINK type truss for the Following data and
mark the loads on the nodes of the truss. Span = 12m Pitch = .Of span Height at eves level = 10m
from the ground Spacing of truss = 5m.c/c.
4, Design a gantry girder to be used in an industrial building carrying an EOT crane for the following
data; Crane capacity = 200 kN. Total self weight of all components = 240 kN. Minimum approach at
the carne hook of gantry girder = 1.2m Wheel base = 3.5m C/C distance between gantry rails = 16m
C/C distance between columns = 8m Self weight of rail section = 300 N/m yield stress = 250 N/mm2
Design the main gantry section. Connection design not required.
5, A toof truss- shed is to be built Jodhpur city area for an industrial use. Determine the basic wind
pressure .The.use of shed 12 mX 20 m
All the Best for Exams
Questions Are Expected for University Exams This May or may Not Be Asked for Exams
Please do not Copy {or) Republish This Questions, Students if You Find the Same Questions in Other
Sources, Kindly report us 16 rejinpaulteani@gm