𝑛𝑡𝑒𝑟𝑚𝑖𝑐𝑎 = 40%

𝑊̇ = 10𝑚𝑤
∆𝑡 = 8°𝐶
𝑉𝑎𝑔𝑢𝑎 = 6 𝑚/𝑠

∙ 𝑃𝐴𝑅𝐴 𝐴𝐺𝑈𝐴 𝑆𝐴𝑇𝑈𝑅𝐴𝐷𝐴

𝑃2 = 10𝐾𝑃𝑎
𝑇2 = 45.81°𝐶

°𝑃𝐴𝑅𝐴 𝑉𝐴𝑃𝑂𝑅 𝑆𝑂𝐵𝑅𝐸𝐶𝐴𝐿𝐸𝑁𝑇𝐴𝐷𝑂


𝑃1 = 10𝐾𝑃𝑎
𝑇1 = 45.81°𝐶

° 𝑄̇𝑐𝑜𝑛𝑑𝑒𝑛𝑠𝑎𝑑𝑜𝑟 = 𝑉 × 𝐴 × 𝐹. ∆𝑇𝑚𝐿𝐶𝐹 … (1)

𝑊̇𝑠𝑎𝑙𝑖𝑑𝑎
° 𝑛𝑡𝑒𝑟𝑚𝑖𝑐𝑎 =
𝑄̇𝑒𝑛𝑡𝑟𝑎𝑑𝑎
̇ 𝑊̇
𝑠𝑎𝑙𝑖𝑑𝑎
𝑄𝑒𝑛𝑡𝑟𝑎𝑑𝑎 =
𝑛𝑡𝑒𝑟𝑚𝑖𝑐𝑎
10𝑚𝑤
𝑄̇𝑒𝑛𝑡𝑟𝑎𝑑𝑎 = → 𝑄̇𝑒𝑛𝑡𝑟𝑎𝑑𝑎 = 25𝑚
0.4
𝑊̇ = 𝑄̇𝑒𝑛𝑡𝑟𝑎𝑑𝑎 − 𝑄̇𝑠𝑎𝑙𝑖𝑑𝑎

𝑄̇𝑠𝑎𝑙𝑖𝑑𝑎 = 𝑄̇𝑒𝑛𝑡𝑟𝑎𝑑𝑎 − 𝑊̇

𝑄̇𝑠𝑎𝑙𝑖𝑑𝑎 = 25𝑚𝑤 − 10𝑚𝑤

𝑄̇𝑠𝑎𝑙𝑖𝑑𝑎 = 15𝑚𝑤

∆𝑇1 − ∆𝑇2
∙ ∆𝑇𝑚𝐿 ,𝐶𝐹 =
ln(∆𝑇1 /∆𝑇2)

∆𝑇1 = 𝑇ℎ 𝑒𝑛𝑡 − 𝑇𝑐 𝑠𝑎𝑙


∆𝑇2 𝑠𝑎𝑙 − 𝑇𝑐 𝑒𝑛𝑡
∆𝑡 = 8°𝐶
∆𝑡 = 𝑡2 − 𝑡1
→ 𝑡1 = 16°𝐶
𝑡2 = ∆𝑡 + 𝑡1 = 8°𝐶 + 16°𝐶
→ 𝑡2 = 24°𝐶
→ ∆𝑡1 = 45.81°𝐶 − 24°𝐶
∆𝑡1 = 21.81°𝑐
→ ∆𝑡2 = 45.81°𝐶 − 22°𝐶
∆𝑡2 = 23.81°𝐶
21.81°𝐶 − 23.81°𝐶
∆𝑇𝑀𝐿 ,𝐶𝐹 =
ln(21.81°/23.81°)
∆𝑇𝑀𝐿 ,𝐶𝐹 = 22.795°𝐶
HALLANDO “F”

𝑡2 − 𝑡1 24 − 22
𝑃= = = 0.0839
𝑡1 − 𝑡1 45.81 − 22
𝑇1 − 𝑇2
𝑅= = 0
𝑇2 − 𝑇1
𝐹=1
𝑉 = 𝐶𝑂𝐸𝐹𝐼𝐶𝐼𝐸𝑁𝑇𝐸 𝐷𝐸 𝑇𝑅𝐴𝑁𝑆𝐹𝐸𝑅𝐸𝑁𝐶𝐼𝐴 𝐷𝐸 𝐶𝐴𝐿𝑂𝑅
1200 𝑤/𝑚2 1200 𝑤/𝑚2 𝑤
𝑉= = = 1500 2
8°𝐶 8°𝐶 𝑚 ×𝑐

EN (1)

𝑘𝑤
1500𝐾𝑤 = 1.5 × 𝐴 × 1 × 22.795°𝐶
𝑚2 × 𝑐
𝐴 = 438.69 𝑚2