state Mass Flow Rate TemperatuEnthalpy Enthropy Exergy (277.

15k) Energy
1 219.2083 3432 6.517 355237.7 752323
2 219.2083 3431 6.537 353799.1 752103.8
3 197.1444 3097 6.627 247406.8 610556.3
4 197.1444 3118 6.643 250669.5 614696.4
5 197.1444 3541 6.639 334280.9 698088.5
6 197.1444 3537 7.283 298178.1 697299.9
7 165.4389 3093.87 7.352 173737.8 511846.4
8 138.9222 2377.23 7.671 34007.24 330250.1
9 166.1028 159.7 0.5474 1443.88 26526.61
10 166.1028 169.7 0.5592 2559.73 28187.64
11 166.1028 266 0.859 4704.222 44183.34
12 166.1028 351.2 1.11 7259.605 58335.3
13 166.1028 472.4 1.441 12098.57 78466.95
14 166.1028 570.5 1.688 16981.48 94761.63
15 202.6667 701 1.993 29974.21 142069.3
16 202.6667 715.5 2.01 31954.55 145008
17 202.6667 860.4 2.324 43620.23 174374.4
18 202.6667 1054 2.705 61378.87 213610.7
19 6.813889 2621 7.824 3039.038 17859.2
20 27.18056 191.175 0.6444 358.4338 5196.243
21 5.444444 2653 7.53 3047.705 14444.11
22 20.36667 286.908 0.932 589.0895 5843.36
23 7.852778 2949 7.752 6235.366 23157.84
24 14.43333 371.427 1.17 681.8812 5360.93
25 6.580556 2942 7.426 5775.82 19359.99
26 6.580556 658.458 1.908 848.8904 4333.019
27 8.511111 3094 7.365 8908.386 26333.38
28 10.40556 3306 7.346 13152.23 34400.77
28 28.05278 731.713 2.06 4487.771 20526.58
30 17.64722 3102 6.655 22097.21 54741.68
31 17.64722 880.613 2.385 3855.517 15540.37
32 7.916667 102.8 0.3603 30.35689 813.8333
33 7.916667 144.5 0.4983 56.60302 1143.958
efisiensi
boiler skip dulu yaaaaaaaa

HPT
Energy Input =2 = 752103.7917
Output = 30+ 3 = 665298.0278
Exergy Input =2 = 353799.0605
Output = 30+ 3 = 269504.0169
Eloss Ein-Eout= 84295.04358
Wt 1 m(hin-hout) = m2(h2-h30)= 72119.54167
Wt 2 m(hin-hout) = m2(h2-h3)= 73215.58333
WHPT 145335.125
Efisiensi 1 =Wt1/Ein-Eout 85.5560880054
Efisiensi 2=Wt2/Ein-Eout 86.856332504
Edt = Σi,T E - Σe,T E - Wt1 12175.50191
Edt = Σi,T E - Σe,T E - Wt2 11079.4602433333

IPT
Energy Input=6= 697299.9
Output= 28+27+7= 572580.5596
Exergy Input=6= 298178.1235
Output= 28+27+7= 195798.4472
Eloss Ein-Eout= 102379.6763
Wt1 m(hin-hout)=m6(h6-h28)= 45540.36667
Wt2 m(hin-hout)=m6(h6-h27)= 87334.98889
Wt3 m(hin-hout)=m6(h6-h7)= 87360.61767
WIPT 220235.973222222
Efisiensi 1 = Wt1 /Ein-Eout 44.4818427954
Efisiensi 2= Wt2 / Ein-Eout 85.3050058803
Efisiensi 3= W3 / Ein-Eout 85.330038952
Edt = Σi,T E - Σe,T E - Wt1 56839.3096344445 Kj
Edt = Σi,T E - Σe,T E - Wt2 15044.6874122223
Edt = Σi,T E - Σe,T E - Wt3 15019.0586344445
LPT
Energy Input = 7 = 173737.833
Output = 25+23+21+19+8= 405071.2243
Exergy Input = 7 = 173737.833
Output = 25+23+21+19+8= 52105.16529
Eloss Ein-Eout= 121632.6677
Wt m(hin-hout)=m7(h7-h25)= 25125.20406
Wt m(hin-hout)=m7(h7-h23)= 23967.13183
Wt m(hin-hout)=m7(h7-21)= 72937.04294
Wt m(hin-hout)=m7(h7-h19)= 78231.08739
Wt m(hin-hout)=m7(h7-h8)= 118560.1253
WLPT 318820.591555555

Wturbintotal= WHPT+WIPT+WLPT= 684391.6898


Eintotal= 825715.01696375
Eouttotal= 517407.62941125
Eloss 308307.3875525
Efisiensi 1= Wt1/Ein-Eout 20.6566250136
Efisiensi 2=Wt2 / Ein-Eout 19.7045187708
Efisiensi 3=Wt3/Ein-Eout 59.9650113237
Efisiensi 4=Wt4/Ein-Eout 64.3174970051
Efisiensi 5=Wt5/Ein-Eout 97.4739168349
Edt = Σi,T E - Σe,T E - Wt1 96507.4636191667
Edt = Σi,T E - Σe,T E - Wt2 97665.5358413889
Edt = Σi,T E - Σe,T E - Wt3 48695.6247302778
Edt = Σi,T E - Σe,T E - Wt4 43401.5802858333
Edt = Σi,T E - Σe,T E - Wt5 3072.5423413889

Condenser
Energy Input = 8+32+20= 348923.1104
output = 9+ 33= 27670.57194
Exergy Input = 8+32+20= 34396.02685
output = 9+ 33= 1500.482974
Eloss Ein-Eout= 32895.54388
Edc = Σi,C E - Σe,C E 32895.54387825
Efisiensi = Ee,c/Ei,c 4.3623729582