Professional Documents
Culture Documents
Loading
Loading
Schedule 40 1.5” x 10 ft
Mechanical Properties
Grade A
Yield: 205 MPa
Tensile: 330 MPa
Grade B
Yield: 240 MPa
Tensile: 415 MPa
Stress Computation
Assuming Grade A,
𝜋 N
Force = 4
[ (48.3 𝑥10−3 𝑚)2 − (40.9 𝑥10−3 𝑚)2 ] x 205x106 m2
Force = 106. 28 kN
Therefore, the load should be less than or equal to 106.28 kN to prevent the pole
from yielding.
Pole Loading:
For this, the pole can withstand the load coming from the devices. However, this
computation does not yet consider wind loading and tensile loading.
60m Pole Calculations
Schedule 40 3” x 10 ft
Quantity: 20
Outside Diameter: 88.9 mm
Inside Diameter: 77.9 mm
Wall Thickness: 5.49 mm
Mechanical Properties
Grade A
Yield: 205 MPa
Tensile: 330 MPa
Grade B
Yield: 240 MPa
Tensile: 415 MPa
Stress Computation
Assuming Grade A,
𝜋 N
Force = 4
[ (88.9 𝑥10−3 𝑚)2 − (77.9 𝑥10−3 𝑚)2 ] x 205x106 m2
Force = 295.41 kN
Therefore, the load should be less than or equal to 295.41 kN to prevent the pole
from yielding.
Pole Loading:
Assuming 60 m,
Mass(kg) Weight(N)
Adding the load from the pole and the devices, the total will be 14 213.6 N.
For this, the pole can withstand the load coming from the devices and from the other
poles. However, this computation does not yet consider wind loading and tensile
loading.