You are on page 1of 8
Universal Cc 3 + fort HYDROMETRIE © For efficiency tests of power station © Universal application on different fixing turbines (Cross brace). devices for use on rod or as cable-sus- pended meter equipment. © For calibration and cyclical control of stream-, flow- and discharge measuring © Thereliableinstrumentapprovedby many devices (Venturi, MID, ...) years practical experience under hard conditions - world-wide. © For measuring flow velocities from 0,025 misec. to 10 m/sec. C 31 — THE ORIGINAL - Best quality money can buy - © Application ‘The 31 Universal Curront Moter is 2 measuring Instrument to determine the flow velocity of water in ‘open canals, rivulets, rivers, and the sea, as weil asin pressure pipes. Of rugged design and made of high-quality materials, the current meter can be used even under extreme conditions. ‘The reliable instrument approved by many years’ practical experience under hard conditions - world wide. For measuring flow velocities from 0,025 msec. to 10m sec. Universal application on different fixing devices for use on rod or as cable-suspended meter equipment. © Function ‘The meter propeller gets tuned by the flow. A magnet turning with the propelisr actuates, once per revoluton, the buit-in Reed contact which is watertight under pressure. “The pulse sequence is nearly proportional to water velocity jn the measuring point ‘The exact relation between the number of propeller revolutions per second and the water velocty is determined by the equation = propeller ravolution per second. k= hydraulic pitch (rm), determined by test runs in the modern rating tank A= meter constant (rmisec.), determined by test runs in the modem rating tank Since among current motors there are mechanical differen- es in the propellers as well as in the bearings, constants k ‘and A are found by specific tests in our own rating tank (Cerificate of calibration BARGO) WW desired, tho cali equation (relation between a and ¥) can also be supplied with uly calculated value and compiled in a table (Velocity table BAREL) For more particulars regarding the calibration of current meters, s2e folder HLE 120/14 If the requirements of accuracy are not so high it is also possible to supply an average equation for the plastic propellers, which is established on the base of several Individual caliration equations. 2 O Measuring Range Depending on the pitch of the propeller chosen, the current meter can be used for different velocity meacuting ranges. In case of oblique water currents It Is possible to measure the component of the flow within an angular range which depends on the type of propeller (600 table). 125mm dia; 0,25 m pitch 125mm dia; 0,25 m pitch 125 mm dia.; 0,50 m pitch 125mm da.; 0,50 m pitch 125mm dia.; 1,00 mpitch 80 mm dia; 0,125 m pitch 4100 mm dia.; 0,125 m pitch 100mm dia; 0,25 mitch ew ea 5,0 50 60 6.0 100 30 25 5.0 0,025 0.035 0,040 0,060 0.085 0,040 0,090 0,035 Py = e = e e as 16 Brass Plastic Brase Plastic Brass Brass Brass Aluminium “Tris max. velosty can only be measured by means ofthe Z 216 counter set which has a counting rate of up o 20 revolutions per s8cond OPossibilities of Application Current meter on Rod For measurements in smaf rivulets and low-level waters urith slow flowing speed the C 31 current meter io used in combination with a rod, The two standard methods of fixing the current meter to the rod are the folowing: Direct fixing on the rod 20 mm dia. Fig. 1: © 31 current meter on rod 20 mm dia Fixing on rod, using the relocating device HERES ‘Tho use of the relocating device offers the advantage that the current meter can be positioned along the vertical in the measuring point without taking the equipment out of the water, Fig. 2: Instrument case for a current meter used on rod Fig. 3: © 31 current meter on rod 20 mm dia. with relo- caiing device HERES. © Possibilities of Equipment Combinations with Current Meter on Rod 1042 404 102 qs cis cis a d te 3 4 105_— 10.10 iy Ba ester oS i) 5 ii u ioe a oc cs Propeller No. 4, 80 mm dia.; 0,125 m pitch Rod 20 mm dia. with base plate and point Propeller No. 1, 125 mm da. 0,25 m pitch om-graduation Propeller No. 2, 125 mm daa; 0,50 m pitch Rod 3m, 3 sections Propeller No. 3, 125 mm daa. 1,00 m pitch Rod 4m, 4 sections Rod 5m. § sections Component propeller A 100 mm dia. Rod 6m. 6 sactions 0,125 m pitch Component propeller R 100 mm dia.; Connecting cable from C31 to counter 0,25 m pitch Z 216 counter Plastic propalier No. 1; 125 mm dia: Z.30 counter 0,25 m pitch 221 counter Plastic propeller No, 2; 125 mm dia Stop watch 0,50 m pitch Case for stop waich ©31 Meter body Cerificate of Calibration BARGO Ground pin short (fer propellor 80 mm dia.) Valocty table BAREL (if wanted) Ground pin tong (lor propeller 125 mm dia.) Instrument caso 17.601 Direction pointer (f wanted) Too's Canvas bag (for rods and HERES) Rod 20 mm cia, with base plate and point ‘dm-graduation Ralocating device HERES Flod 3 m, 6 sections 2m,2 sections Rod 3m, 3 sections 2m,4 sections Rood 4 m, 4 sections 3m, 3 sections Rod 5 m5 sections ‘4m, 4 sections lod 6 m, 6 sections 5,5 sections © Cable-suspended Current meter For measurements in deep waters and at hicher flowing speeds the OTT C 31 current meter is used as cablo- ‘suspended equipment. Fig, 4: “Two types of sinker can be supplied: 5 kg and 10 kg. ‘The sinkers amit be equipped with a ground-eeler. In ‘special cases it is possible to carry out measurements without the aid of a winch. Gable-suspended current meter with sinker Fig. 5: Instrument case for cable-suspended meter ‘equipment vith sinker. Fig. 8: Instument case for C 31 cable-suspended meter ‘equipment with middle piece 25 kg, 50 kg or 100 kg. For more detalis on our winches, as wal as further faciitios for integration measurements, see folder 15.470.000.P.E Fig. 6: Cablo-suspanded meter with jb, 25 kg single-drum winch, Z 215 counter set and 25 kg middle piece. Fig. Cable-suspended current meter with jib, 100 kg, single-drum winoh, Z 215 counter set and 50 kg iddle piece . Thiee types of middle piece can be supplied: 25 kg, 50 kg and 100 kg, All the middle pieces are generally equipped ‘with an electrical orcund-feeler. For measurements with middle pieces always a winch or ‘cable-way installation corresponding to the weight of the coutit Is required, © Combinaton-possibilities of Cable-suspended C 31 Current meters 10.41 10.42 148 1038 1025 “88 sO (3 \ ' \_ ey | 10.44 ete teas 1s a paral nae baconan arc iren nee meee comes OE to 24 1028 t 0 { A 1058 on i iced La ‘zo—} |< or ross may I ; I 10858 | smait cable-suspencea meter equipment (with winch) Water velocity v= 0,03 to 4 mv | | 10.0 or 1054 10.53 10.52 al Mh 288 e eo —— = fa, om © 1050 ‘ost 1085 Large able-suspondod moter equipment (25kg middle piece) Water velocity v= 0.03 to 3 m/s a | =—4 = ! rose 10.64 dee es Pot wus Water velocity v = 0,08 to 9,5 m/s 1066 ae ee 1074 Af us S 072 ued 1055 +f 10.68 Large cablo-cuspended motor equipment (100 kg middle piece) Weter valocity v= 0,03 to 10 mis 10.26 10.28 1 1 an 075 10.57 1073 076 Water depth” pt 078 10.57 1073 0.76 Water deptht 1044 L tas 1075 10.71 10.73 E1070 Water deptht (a 1078 10.71 10.73 1070 Water depth’ a ey 1078 10.73 1070 Water depth’ 15 jis 16 SsFFHFFET2TESCSLSRLSRLSRBBNRBRVS a ee Propeler No. 4, 80 mm dia; 0,125 m pitch Propeter No. 1, 125 mm dia; 0,25 m pitch Propeter No. 2, 125 mm dia; 0,50 m pitch Propel No. 3, 125 mm dia; 1,00 m pitch Plastic propeller No. 1; 125 mm dl 0,25 m pith Plastic propetier No. 2; 125 mm dla 0,50 m pitch 31 meter booy 215 counter Z 30 counter Z 2tcounter Stop watch Case for stop watch Certificate of calibration BARGO (ea. propeller 1 x) Velocity table BAREL (if wanted) Sinker 5 kg Sinker 10 kg Connesting cable 111/113 - 031 to counter Stabilizer piece 0.8 m- for sinker Single drum winch 25 kg Jib for single drum winch 25 ko vib pulley Connecting cable 111/200 from winch to counter Carrying-case for 25 kg winch Instrument-case 17.602 Intermediate piece for middle piece comection Middle piece 25 ka, Connecting cable 111/456 - irom current meter to winch] Carrying case for middle piece 25 kg Stabilizer tal piece; 1,4 m long Connecting cable 111/454 - from C 31te winch Midele piece 50 kg, Carrying case for middle piece 50 ka Single drum winch 100 kg Carrying case for single drum winch 100 kg Carrying case for middle piece 100 kg, Connecting cable 111/410 - from C 31 to winch Instrument case 17.603 - f. cable suspended equipment} Middle piace 100 kg Toole Jib for single drum winch 100 kg * see overleat OExtra Equipment For other fields of application (e.g. installation in pressure pipes with cross brace or Dutor device as per VDVVDE rue 2640, part 2) aswellas for other types of fixing methods (2.9. ‘spacial-section rods, sliding meter-attachments), and inte- {gation moacurements a great number of special devices are available on request. ©Dimensional Drawing * The maximum water depth for gauging depends on the water volocity an the permissible error in depth. The dapih error can be corrected according to the following formua correction in length for the part of cable below water surface = correction in length for the part of cable above water surlace ‘@= incination of cables against the vertical f= water depth up to gauging point = height of pulley above water surface 216 ©.1 Cablo suepondod currant meter ‘on gas spring tensioned cable-way. meter. ‘Measuring-Van with OTT- 100 kg Double drum winch and C 31 current e C31 with 25 kg Singledrum winch and movable Troloy for the measure- ment e.g. from a bridge. ‘dotals may be changed without notice. ot ry program, e.g Water Level Recorders Winches, Cable ways Pressure Probes Shaft Encoders Data Loggers, Smart Sens, Data Romoio Transmission Please ask for price list —_f MessTecHNc OTTNESSTECHNIK GmoH8.Co.kG. Pestiacn 2140 ‘usonigstiabe 15 Tel.c@3i-3017-0 Faxd83t 817-200 100010017

You might also like