Notes Sample Number Pump Setting S (%) Pump Speed N (RPM) Water Temperature T (°C) Inlet Pressure P0 (Kpa) Pump 1 Pressure P1 (Kpa)
Notes Sample Number Pump Setting S (%) Pump Speed N (RPM) Water Temperature T (°C) Inlet Pressure P0 (Kpa) Pump 1 Pressure P1 (Kpa)
1
2
3
4 90 1620 22.0 2.9 103.4
5 90 1620 22.1 3.1 103.4
6 90 1620 22.1 3.2 103.4
7 90 1620 22.2 3.3 103.4
8 90 1620 22.2 3.5 103.4
9 90 1620 22.2 3.6 103.4
10 90 1620 22.2 3.6 103.4
11 90 1620 22.4 3.7 103.4
12 90 1620 22.2 3.7 103.4
13 90 1620 22.3 3.8 103.4
14 90 1620 22.3 3.8 103.4
15 90 1620 22.7 2.2 103.4
16 90 1620 22.7 2.6 103.4
17 90 1620 22.9 3.0 103.4
18 90 1620 22.9 3.2 103.4
19 90 1620 22.9 3.2 30.6
20 90 1620 23.0 3.1 34.5
21 90 1620 23.1 3.4 37.9
22 90 1620 23.1 3.6 41.3
23 90 1620 23.1 3.6 43.0
24 90 1620 23.1 3.7 44.7
25 90 1620 23.1 3.7 46.7
26 90 1620 23.1 3.8 49.4
27 90 1620 23.2 3.6 49.0
28 90 1620 23.1 3.7 51.3
29 90 1620 23.3 1.3 103.4
30 90 1620 23.4 1.7 103.4
31 90 1620 23.5 2.4 103.4
Page 1
FM51 Series and Parallel Pumps - Run 1 Results
Page 2
FM51 Series and Parallel Pumps - Run 1 Results
Pump 2 Motor 1 Flow Operating Density Pump 1 Pump 1 Pump 2 Pump 2 Pump 1
Pressure Torque Rate Mode of water Inlet Outlet Inlet Outlet Total
P2 t Q rho Velocity Velocity Velocity Velocity Head
[kPa] [Nm] [l/s] [kg/m³] [m/s] [m/s] [m/s] [m/s] [m]
Page 3
FM51 Series and Parallel Pumps - Run 1 Results
43.6 0.44 1.207 Parallel 997 1.39 2.51 1.39 2.51 10.595
45.9 0.51 1.000 Parallel 997 1.15 2.08 1.15 2.08 10.483
48.5 0.49 0.793 Parallel 997 0.91 1.65 0.91 1.65 10.396
50.4 0.44 0.623 Parallel 997 0.72 1.30 0.72 1.30 10.349
52.1 0.45 0.490 Parallel 997 0.57 1.02 0.57 1.02 10.321
52.7 0.39 0.414 Parallel 997 0.48 0.86 0.48 0.86 10.295
55.7 0.45 0.207 Parallel 997 0.24 0.43 0.24 0.43 10.265
57.9 0.46 0.000 Parallel 997 0.00 0.00 0.00 0.00 10.238
Page 4
FM51 Series and Parallel Pumps - Run 1 Results
Pump 2 Combined Pump 1 Pump 2 Total Pump 1 Pump 1 Pump 2 Overall Walkthrough
Total Total Hydraulic Hydraulic Hydraulic Mechanical Efficiency Efficiency Efficiency Questions
Head Head Power Power Power Power E1 E2 Egr Score
[m] [m] [W] [W] [W] [W] [%] [%] [%] [%]
Page 5
FM51 Series and Parallel Pumps - Run 1 Results