CALCUL DES STRUCTURES BOIS

---------------------------------------------------------------------------------------------------------------------------------
-------
NORME: CB71
TYPE D'ANALYSE: Vérification des pièces
---------------------------------------------------------------------------------------------------------------------------------
-------
FAMILLE:
PIECE: 10 BANANE POINT: 2 COORDONNEE: x = 0.06 L = 0.56
m
---------------------------------------------------------------------------------------------------------------------------------
-------
CHARGEMENTS:
Cas de charge décisif: 2 ULS /1/ 1*1.00
---------------------------------------------------------------------------------------------------------------------------------
-------
MATERIAU:
KSh1800 Humidité du bois: 12.00 %
Variation de l'humidité: 9.00 %
---------------------------------------------------------------------------------------------------------------------------------
-------
PARAMETRES DE LA SECTION: Poutre KS 30 x 250 (1800)

ht=42.2 cm
bf=3.0 cm Ay=84.44 cm2 Az=84.44 cm2 Ax=126.67 cm2
ea=1.5 cm Iy=18817.56 cm4 Iz=95.00 cm4 Ix=905.49 cm4
es=1.5 cm Wely=891.36 cm3 Welz=63.33 cm3
---------------------------------------------------------------------------------------------------------------------------------
-------
CONTRAINTES DE CALCUL: CONTRAINTES ADMISSIBLES:
Sig' = 1.11/126.67 = 0.09 MPa Sig'_b = 20.00 MPa
SigF_b = 15.50 MPa
SigFy = My/Wely coef.humcom = 1.12
= 4.25/891.36 = 4.77 MPa coef.humflex = 1.06
coef.angle = 1.00
coef.haut = 1.00
coef.larg = 1.80
---------------------------------------------------------------------------------------------------------------------------------
-------

PARAMETRES DE DEVERSEMENT:

ld = 3.04 m Sig_cr = 1.20 MPa kinst = 0.08


ld mod = 0.9*lD+2.0*h =4.78 m Lambda = 3.60
---------------------------------------------------------------------------------------------------------------------------------
-------
PARAMETRES DE FLAMBEMENT:

en y: en z:
Ly = 10.12 m Lambda y = 75.34 Lz = 1.50 m Lambda z = 173.21
LFy = 10.12 m Ky = 1.83 LFz = 1.50 m Kz = 14.27

---------------------------------------------------------------------------------------------------------------------------------
-------
FORMULES DE VERIFICATION:
Sig_adm = SigF_b*coef.humflex*coef.haut = 15.50*1.06*1.00 = 16.43 MPa
|(SigF_b/Sig'_b)*K*Sig'| + |SigFy/kinst| = ((15.50*1.06)/(20.00*1.12))*14.27*0.09 + 4.77/0.08 = 62.54
> 16.43 MPa

---------------------------------------------------------------------------------------------------------------------------------
-------
DEPLACEMENTS LIMITES
P_inf = 0.00 % Partie des charges d'exploitation considérée de longue durée

Flèches
Prise en compte de la contreflèche ucz = 0.0 cm
uz = uz_ld*Theta_z + uz_i - ucz = 0.6*1.00 + 0.0 - 0.0 = 0.6 cm < uz max = L/300.00 = 3.4 cm Vérifié
Cas de charge décisif: 1*1

Déplacements Non analysé


---------------------------------------------------------------------------------------------------------------------------------
-------
Profil incorrect !!!