In country X, City Y, Customer complaint about Capacity issue and low HSUPA
throughput

during Special events. Complaint area is hot spot and mostly special event happened there.

Alarm

No Active alarm on surrounding sites.

2015-07-03 HUAWEI CONFIDENTIAL Page2,


Total13
High code and DL power congestion issue

Cause
1. Analysis
Congestion KPIs analysis:- From the KPI can see many code cong and DL Power cong.

2. Parameter setting verification Network


recommended
value

Current
setting

Network
recommended
value

Current
setting

2015-07-03 HUAWEI CONFIDENTIAL Page3,


Total13
High code and DL power congestion issue

Network
recommended
value

Current
setting

2. DT held at the complaint spot.

I-Site location

2015-07-03 HUAWEI CONFIDENTIAL Page4,


Total13
High code and DL power congestion issue

ii. Google Location

iii.Outdoor test RSCP

iv. Outdoor Test ECNO

2015-07-03 HUAWEI CONFIDENTIAL Page5,


Total13
High code and DL power congestion issue

From the above test result, RSCP and ECNO are quite good at the complaint location. We notice
that there is not any coverage problem. Only problem of high traffic during the special event that’s
why get customer complaint.

Handling
1. Handling
Parameter optimization
Process
Purpose to implement below action to reduce DL power congestion and code congestion:

1- Purpose to change PCPICH power and Maxtxpower setting on site NTB6709 as below:

PCPICH- PCPICH- Maxtxpower- Maxtxpower


CELL NAME CI
current recommend current -recommend

NTB6709U_8NB01_S03 722 300 310 400 430

NTB6709V_8NB01_S01 12547 330 310 430  

NTB6709V_8NB01_S03 12557 300 310 400 430

NTB6709W_8NB01_S01 22337 330 310 430  

NTB6709W_8NB01_S03 22347 300 310 400 430

2- Change HSPDSCH Code number from 5 to 2.

3- Downlink CAC parameter optimization as below standard:


2015-07-03 HUAWEI CONFIDENTIAL Page6,
Total13
High code and DL power congestion issue

DLCONVAMRTH DLCONVNONAMRTH DLOTHERTH DLHOTH


DLCELLTOTALTHD
D D D D

90 90 85 92 95

4- Down link LDR action changing as below standard

DLLDRFIRSTACTION DLLDRSECONDACTION DLLDRTHIRDACTION

CodeAdj BERateRed InterFreqLDHO

5- Common channel power changing

Current Recommend
Command Parameter
Value Value

MOD UCELL PSCHPower -5 -8

MOD UCELL SSCHPower -5 -8

MOD UCELL BCHPower -2 -5

MOD
AICHPowerOffset -6 -9
UAICHPWROFFSET

MOD
PICHPowerOffset -7 -10
UPICHPWROFFSET

MOD USCCPCH PCHPower -2 -5

6- LDM parameter changing to make UE entry LDR status quicker

  DLLDRTRIGTHD DLLDRRELTHD

current value 70 60

recommend value 60 50

7- 1B event threshold changing to make UE leave active set easier and reduce SHO
overhead.

  INTRARELTHDFOR1BCSVP INTRARELTHDFOR1BCSNVP INTRARELTHDFOR1BPS

current value -12 -12 -12

2015-07-03 HUAWEI CONFIDENTIAL Page7,


Total13
High code and DL power congestion issue

Result
recommend value -10 -10 -10

Parameter changing script:

Parameter
changing mml.txt

Application of Cell is recommended to satisfy high traffic requirement.

After Change parameter KPI Get normal.

RRC Setup Success Ratio (service)(%)

2015-07-03 HUAWEI CONFIDENTIAL Page8,


Total13
High code and DL power congestion issue

CS RAB Setup Success Ratio (Cell)(%)

RAB Establishment Success Rate - PS(%)

2015-07-03 HUAWEI CONFIDENTIAL Page9,


Total13
High code and DL power congestion issue

VS.CS.AMR.Call.Drop.Cell.Rate(%)

VS.PS.Call.Drop.Cell.Rate(%)

2015-07-03 HUAWEI CONFIDENTIAL Page10,


Total13
High code and DL power congestion issue

VS.RRC.Rej.Sum

VS.RAB.FailEstabCS.Cong

2015-07-03 HUAWEI CONFIDENTIAL Page11,


Total13
High code and DL power congestion issue

VS.RAB.FailEstabPS.Cong

ForSugges
such kind of issue, you can have try by changing the suggested
tion
parameter.

2015-07-03 HUAWEI CONFIDENTIAL Page12,


Total13
High code and DL power congestion issue

2015-07-03 HUAWEI CONFIDENTIAL Page13,


Total13

You might also like