You are on page 1of 3
Technical Information DOW™ HDPE DMDA-8920 HEALTH+™ High Density Polyethylene Resin Over <> yw DOW HDPE DMDA.8920 HEALTH#™ Resin isa narrow molecular weight eitribution high density copolymer designed to offer an excellent balance of toughness, environmental stress cracking resistance, and processabilly. The ‘eain fs suitable for njection-moldes meal devioes such as IV kt components and respiratory care, Ths product can ‘also be used in pharmaceutical packaging including caps and closures. Main Characteristic: + Excellent toughness + Excollontstross crack resistance + Good processability + High gloss parts Comptes wit + US. FDA 21CFR 177.1520) + USP XxIll Class VI + EU,No 1072011 + Canadian HPFB -No Objection + Drug Master Filo Listing Consul the regulations for complete deta. Additive + Antbock: No + Slip: No + Processing Ais: No Nominal Value (English) Nominal Value (SI) Test Method 0.954 glen? 0.954 glen? ‘ASTM 0792 ase Densily™ 0.954 glen? 0.954 glen Dow Method Mal Index (100°G72.16 3) 209/10 min 20_g/i0 min _ASTMDI236 Environmental Svess-Crackng Reslsiance ‘ASTM D1699 122°F (60°C), 100% Igopal, P50 3.00 he 3.00 br Wochanical Nominal Value (English) Nominal Value (SI) Test Mothod Tensile Svength ‘ASTM D538 Yiols 4100 psi 283 MPa Break 2000 ps 138 MPa Tensile Elongation ‘ASTM Dae Yiela 70 % 70 % Break 250 % 250 % Flexural Noduhis -2% Secant 167000_psi 7150 MPa ASTM D700 impact Nominal Value (English) Nominal Value (SI) Test Method Tensile impact Svength? 200 fein’ 42.0 kim? ‘ASTM D1822 Hardness Nominal Value (English) Nominal Value (SI) Test Method ‘Durometer Hardness (Shore B) a7 57 ‘ASTM 02240 Thermal Nominal Value (English) Nominal Value (SI) Test Method Detoion Temperature Under Load ‘ASTM DAB 86 psi (0.45 MPa), Unannealod 163.‘ Rs °C Biitloness Temperature e058 °F e761 ‘ASTM DTS Vieat Sotening Temperature 25 ware ‘ASTM D1525 Mating Temporature (O50) 265 F 130°C Dow Mathod Peak Ciystalization Temperature (O50) 2 F ne Dow Method ‘Additional Information Plague molded and tesied in accordance with ASTW DATE. Page: tof {8° Trademark of The Dow Chemical Company (Dom ora af 1 company of Dow Foe No, 400-0012558700 Rew 2011.07.28 Notes ‘These are typical properties only and are not tobe construed as specications. Users should confirm results by thelr own tests ‘Base densi is estimated using the assumption thal every 1000 ppm af aniblock nthe finshed product raises the densly ofthe polymer ay 0.0006 glem’, Base densiy isthe estimated density of the polymer if cid not contain any anibiock, ype § Foe No, 400-0012558700 Page: 203 {8 Trademark o The Dow Chemical Company (Dow) oranaflted company of Dow, Rew 2011-07-28 Product Stewardship Customer Notice Medical Applications Policy Disclaimer Additional Information swwww-dowplasties.com Page: $03 ‘The Dow Chemical Company and is subsidiaries (‘Dow’) has a fundamental conceen fo all who make, distribu, and use its praducts, and fr the envionment in which we lve. This concern i the basis for our Product Stewardship philosophy by whien we assess the safety, heath, and environmental information on ‘Ur products and then take appropriate steps to protect employee and public health and our envronment ‘The success of our Product Slewardship program resis with each ard every individual involved with Dow products — fom the inal concept and research, io manufacture, use, sale, disposal, and recyete of each product Dow strongly encourages is customers to review both thelr manufacturing processes and ther ‘applications of Dow products from the standpoint of human health ané environmental quay to ensure that Dow products are nat used in ways for which they are not intended or lasted. Dow personnel are ‘avaliable fo answer your questions and to provide reasonable technical suppor. Dow product Itrature, including safety data sheets, should be consulted pir to use of Dow products. Current safety data sheets fare avaiale trom Dow, NOTICE REGARDING MEDICAL APPLICATION RESTRICTIONS: Dow willnot knowingly sellor sample ‘any product or service "Produc into any commercial or developmental appfestion that sinned fr 2. long-torm or pormanent contact with internal bodily uid or tissues. “Lorg-rm” fs contact which ‘excbads 72 continuous hours », sein cardiac prosthetic devices regardless of the length of time involved (‘cardiac prosthetic devices” include, but are not Imited to, pacemaker leads and devices, arial heats, hear valves inira-aortic balloons and contol systems, and venticular bypass-ass sod devices) «, use asa eriical component in mecical devices that suppor or sustain human We: or 4. Use speciicaly by pregnant women orin applications designed spacifialy to promote ar interfere with human reproduction. Dow requosts that customers considering use of Dow products in mecical applications not Dow so that ‘appropriate assessments may be conducted. Dow does not endorse or claim suitably offs products for pectic medical appications ki he responsibly of the modical device ox pharmaceutical manufacturer to determine thal the Dow product is safe. wu, and teehmeally suitable forthe Intended Use. DOW MAKES NO WARRANTIES, EXPRESS OR IMPLIED, CONCERNING THE SUITABILITY OF ANY DOW PRODUCT FOR USE IN MEDICAL APPLICATIONS. NOTICE. No freedom from infingement of any patent owned by Dow or thers i to be inferred. Because Use conditions and applicable laws may difer from ane location to another and may change wih Ue, the ‘Customer is responsible for determining whether products andthe information in this cacumnt are ‘appropriate fr the Customers use and for ensuring thal the Customer's workplace and alsposal practices ate in compliance with applicable laws and other governmental enactments. Dow assumes no obigation fr labliy forthe informalion in hs document, NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. NOTICE: patil are dsered a ‘penta ar ‘development: (1) prod! pectin may rat il dled (2) nays harard ndeason hang are are rogues (2) er frat potartal for Dono cxngespectnabons ferderascontnue poston a(t) ahah Dow ay Fo me's te oie serps sich rosucs, Dow sme cae £9 ™ Trademark of The Daw Chemical Company (Dom ran North America EuropelMiddle East +1800-3604-6357 US. & Canada: 1-800-441-4309 S31-11807-2526 1.989.832.1428 Italy +800-783.825 Morice: ++1-800-441-4969 Latin America South Africa +800-99.5078 ‘Argentina +454-11-4318-0100 raz +405-11-5188-0000 Colombia: *57-1-218-6000 Asia Pacific +800-7776-7776 Mexico: ++82-55.5201-4700 +603-7965-5292 ‘This document i intended for use within North America Published: 2009-00-25 © 2016 The Dow Chemical Company <> afte’ company of om, +m No, 400-00125587en Rew 2041.07.28

You might also like