P17‐31‐01

ARIETTA 70/70a/60  version5.1
Product explanation

September 12, 2017
Innovating Healthcare,  Products marketing department
Embracing the Future
© Hitachi, Ltd. 2017. All rights reserved.
Contents

1. Probe
2. Function
3. Options / version up

© Hitachi, Ltd. 2017. All rights reserved. 1


1. Probe

© Hitachi, Ltd. 2017. All rights reserved. 2


Probe

Probe Feature ARIETTA 70 ARIETTA  60 Remark


Intraoperative, 13mm,  
L51K
15‐3MHz (new) (new)
Not available for USA.
• ARIETTA 60 Sales with ARIETTA 
Endoscopic Ultrasound,   • V5.1 and later 60 is possible after 
EG‐3270UK 
6R, 10‐5MHz (new) • SOP‐ARIETTA60‐65 self‐declaration of EC 
• JB‐293 by HOYA (expected at 
November 2017)
• ARIETTA 60
Endoscopic Ultrasound,   • V5.1 and later
EG‐3670URK  Ditto.
6R, 10‐5MHz (new) • SOP‐ARIETTA60‐66
• JB‐293
• ARIETTA 60
Endoscopic Ultrasound,   • V5.1 and later
EG‐3870UTK  Ditto.
10R, 10‐5MHz (new) • SOP‐ARIETTA60‐67
• JB‐293
• ARIETTA 60
Trachea and Bronchial   • V5.1 and later
EB‐1970UK N/A Ditto.
Tree, 6R, 10‐5MHz (new) • SOP‐ARIETTA60‐68
• JB‐293
• ARIETTA 60
Trachea and Bronchial  
EB19‐J10U  • V4.0 and later Not available for USA.
Tree, 6R, 10‐5MHz (new) • SOP‐ARIETTA60‐89

© Hitachi, Ltd. 2017. All rights reserved. 3


L51K

• Downsized from L43K and able to approach narrow target.

L51K L43K
Frequency [MHz] 15‐3 12‐2
L43K FOV [mm] 13 25
Probe size[mm] 10×25 12×51
Applicable trocar[mm] φ10 φ12
L51K

• Trapezoidal scanning of 30 degrees compensates 
field of view decline by down sizing.

• With THI (WbT, HdT) may reduce grating lobe 
artifact.

Fundamental WbT
© Hitachi, Ltd. 2017. All rights reserved. 4
New modes (VC34, C35)

• Following modes are newly applicable.

Probe Function
VC34 TDI
C35 Strain Elastography

© Hitachi, Ltd. 2017. All rights reserved. 5


2. Function

© Hitachi, Ltd. 2017. All rights reserved. 6


SWM kPa display (ARIETTA 70 only)

• E (kPa)  is newly added to result of SWM

• Following items are added to measurement report
• E (kPa) : Elastic modulus
• IQR/Median of Vs
As written in below article, concept that if IQR/Median is less 
than 30% is reliable is getting polular, and there is a possibility to 
be a guideline.
Statement of SRU consensus meeting is published as paper at
Radiology (published on September 2015) .

SWM
Less than 30 % of IQR/Median 30% is judged as reliable © Hitachi, Ltd. 2017. All rights reserved. 7
Strain Elastography – Assist Strain Ratio & Auto Frame Selection

• When freeze Elasto mode, frame selection and FLR measurement can be performed 
seamlessly by just pressing update button and pointing the position of lesion.

Press Update SW Adjust ROI at lesion  by trackball and press Enter switch
→ Auto frame select & auto  → Auto measurement at lesion and fat
FLR measurement start

• Preset
System Preset > Application > Elasto > Press Guide > Interlocking FLR Measurement

ASR : Asist Strain Ratio
AFS : Auto Frame Selection

© Hitachi, Ltd. 2017. All rights reserved. 8


Display of radial probe

• U/L inversion
• Flip vertical (Invert U/L) while real time is applicable.

• When ‘Invert U/L’ is pressed,
• Orientation mark display is inverted upside down.
• Indication is changed from DISTAL to PROX..

Invert U/L

© Hitachi, Ltd. 2017. All rights reserved. 9


T/L selection of Biplane probe
• Initial plane of Biplane
• Initial plane after probe change is selectable
• Preset : System Preset > Region
• Setting
• T : Display T plane
• L : Display L plane
• Previous exam : 
C41L47RP, CL4416R : Inherit plane of current plane when preset is changed
CC41R, CC41R1 : Display T plane when preset is changed
* Initial plane setting of the machine which updated from V5.0 or before is ‘Previous exam’.

• Plane button is activated when below Convex‐Linear Bi‐plane probe is active.
• Applicable probes : C41L47RP, CL4416R

This was inactive when V5.0 and before

Plane
CV LN CV LN
Active Freeze Plane+ Active Freeze Freeze Active

© Hitachi, Ltd. 2017. All rights reserved. 10


Scan area change during PAN Zoom

• Scan Area can change while PAN Zooming
• Scan Area size which modified during PAN Zoom is kept after PAN Zoom is turned off.

• Operation
• Press Scan Area switch during PAN Zooming.

• When Scan Area is pressed, Track ball priority is changed to Scan Area modification.

• Use trackball and change Scan Area

© Hitachi, Ltd. 2017. All rights reserved. 11


HI Zoom + CF ROI operability

• Color ROI size and HI ZOOM ROI size can be kept individually.
Preset : System Preset > Application > B > Common > Keeping HI Zoom Size when Color On

’Keeping HI Zoom Size when Color ON’ setting : OFF (conventional)

Zooming Color ROI area

‘Keeping HI Zoom Size when Color ON’ : ON

Zooming HI Zoom ROI area 
independent from Color ROI size

© Hitachi, Ltd. 2017. All rights reserved. 12


Minimum CF ROI width (C35)

• Minimum Color Flow ROI width becomes 10% instead of 25%
• Applicable probe : C35

up to Ver5.0 Ver5.1

© Hitachi, Ltd. 2017. All rights reserved. 13


B mode U/L dual display

• U/L format of B mode by linear probes is applicable
Superficial examination with wide FOV is useful for example in orthopaedic surgery.

Dual Display
Format

Dual display (L/R) Dual display (U/D)

Remark : While following mode is active, U/L display is not possible to use.
• DSD • Image Compare
• CHI • Physiological signal (ECG, PCG, Resp, Pulse)
• Stress Echo • Elasto Strain Hist.
• RVS • Combined 2B
• 3D

© Hitachi, Ltd. 2017. All rights reserved. 14


B mode U/L dual display

• Preset
• Dual Display Format
• Preset Setup > Application > General > Common
• Settings
• L/R or U/D

• Position of Information display when U/D format
• Preset Setup > System Preset > General > Common 1
• Settings
• Lower : Display at same position to L/R display (Same as HI VISION)
• Upper : Display at beside of both upper and lower images

* Red frame : information of upper image / Blue frame : information of lower image

Information display

Lower setting Upper setting

© Hitachi, Ltd. 2017. All rights reserved. 15


Improvement of continuity of Video Clip loop

• Video Clip loop play discontinuity of last frame and first frame is improved.
• Gap which was easy to notice especially single heart beat loop play during 
stress echo examination will be fixed.

Before After

© Hitachi, Ltd. 2017. All rights reserved. 16


Raw data to Video clip auto conversion & transfer

• Multi RAW data which selected at tile screen can be transferred to server after auto 
conversion to Video Clip
By pressing Network button, multi 
RAW data automatically played in full 
screen and converted and saved as 
Video Clip, and transferred to server.

© Hitachi, Ltd. 2017. All rights reserved. 17


Annotation dictionary addition

User dictionary numbers are increased from 8 to 28.
User dictionary 1– 28 can be created and edited at user dictionary registration screen.
Preset Setup > Dictionary > Registration 

© Hitachi, Ltd. 2017. All rights reserved. 18


Annotation operability
• Replace button
• Replace OFF: insert input
• Replace ON: overwrite/replace input

• R.E.[Move Cursor] addition (change name from [Tab/Del. Word])


• Able to select word faster than track ball operation
• Able to move cursor to between words faster 
than track ball operation
Reduce complicated operation of word replacement, delete insertion 
by trackball
Replace ON Replace OFF

• Add Delete Last button
• Delete last input/edit word
* Font size adjustment button which located here until V4 is substituted by Anno.+KB tab or Preset
© Hitachi, Ltd. 2017. All rights reserved. 19
Annotation functions

1. Expand class numbers from 5 to 10
– To compete competitor’s specification, class numbers are increased from 5 to 10 
for each dictionary. (EPIQ has 10)

© Hitachi, Ltd. 2017. All rights reserved. 20


Annotation functions

2. Class identification by colors
– With attaching colors on annotation button, identification of class of word is 
possible.
– Legend of class and color correspondence is shown at user dictionary registration 
screen.

Image of word and class setting

© Hitachi, Ltd. 2017. All rights reserved. 21


Annotation functions

3. Word filtering function on/off is settable by preset
Preset Setup > Region > * > Annotation
– Annotation button layout is not changed when inputting words by 
keyboard

© Hitachi, Ltd. 2017. All rights reserved. 22


Annotation functions

4. Pointer position preset
– Pointer Home Position preset setting is changed.
– Review Area : Pointer is positioned an thumbnail area when Pointer is turned On.
– Comment Area : Pointer is positioned at comment area when Pointer is turned On.
– Previous Position : Pointer is positioned at previous position when Pointer is turned On.
– Preset Setup > Region > * > General > Display > Pointer Home Position

© Hitachi, Ltd. 2017. All rights reserved. 23


Response improvement of OBST 3D operation

• Response of 3D operation is improved. (Some are already improved on V2.1)

4Dshading  Operation Ver.2.1〜 Ver.5.1


4Dshading On Light source move  
Volume rotation  
Volume parallel shift  
4Dshading Off Volume rotation  
Volume parallel shift  

:response is improved
:response is not improved

© Hitachi, Ltd. 2017. All rights reserved. 24


Flow 3D noise reduction

• Excessive noise of Flow 3D  is reduced.

Ver5.0 Ver5.1

© Hitachi, Ltd. 2017. All rights reserved. 25


DV measurement accuracy

• Heart beat cycle, S point and a point recognition of DV(Ductus Venosus) 
measurement is improved.
1beat

Wave form of Ductus
Venosus and  heart beat 
cycle to be detected

Wrong detection 
of a wave

Wrong : 6  Wrong detection 
Beats Correct :4 Beats
of S wave

Before improvement After improvement
(Arrows are wrong detection points)
© Hitachi, Ltd. 2017. All rights reserved. 26
OB measurement table (CFEF)

• AC2, HC3 (for CFEF) are compatible to User‐defined FW Equation (green frame on 
below image)
• FW table of French CFEF is compatible (red frame on below image) 
* SR export is not available (ARIETTA 850 v1.2 is available)

© Hitachi, Ltd. 2017. All rights reserved. 27


OB graph visibility

• For better visualization of OB graphs, plot points and line thickness is changed

Report

OB Graph

Ver5.0 Ver5.1
Remark : Report and OB graph appearance is changed after version up to 5.1
© Hitachi, Ltd. 2017. All rights reserved. 28
Log of filing functions

• To analysis error source, error log function of Network operation, 2DTT operation is 
improved.
• Following log export is added  to ‘Log OutPut 2’
• DICOM conversion log (File operation like Network)
• 2DTT analysis log (Operation at 2DTT analysis screen)
• Message log (Operation to change screen, etc.)

[Log file name] [Type]
DSL_xxxxxxxx.log Network transfer operation log
APLC_xxxxxxxx.log Message log like screen change etc.
AD2T_MAIN_xxxxxxxx.log 2DTT analysis operation log(error log)
AD2T_SUB1_xxxxxxxx.log 2DTT analysis operation log(error log)

© Hitachi, Ltd. 2017. All rights reserved. 29


3. Options, version up

© Hitachi, Ltd. 2017. All rights reserved. 30


Options

• Software option
Model name Description
SOP‐ARIETTA60‐65 • EG‐3270UK connection software
• Sales is possible after self‐declaration of EC by HOYA (expected 
at September 2017)
• Not available in USA
SOP‐ARIETTA60‐66 • EG‐3670URK connection software
• Sales is possible after self‐declaration of EC by HOYA (expected 
at September 2017)
• Not available in USA
SOP‐ARIETTA60‐67 • EG‐3870UTK connection software
• Sales is possible after self‐declaration of EC by HOYA (expected 
at September 2017)
• Not available in USA
SOP‐ARIETTA60‐68 • EB‐1970UK connection software
• Sales is possible after self‐declaration of EC by HOYA (expected 
at September 2017)
• Not available in USA
SOP‐ARIETTA60‐89 • EB19‐J10U connection software
• Not available in USA

• Hardware option
N/A © Hitachi, Ltd. 2017. All rights reserved. 31
Version up

• Service pack
Model name Name Description

SP‐ARIETTA70‐S510 Service pack for ARIETTA 70 • Software version up (No 


additional probe connection)
SP‐ARIETTA60‐S510 Service pack for ARIETTA 60 • Free of charge

• Please read installation manual carefully.
• Update from Ver.4.* or before is required to update to version 5.0 in advance.

© Hitachi, Ltd. 2017. All rights reserved. 32


Version up

Version up kit (new probe connection)
Model name Name Description

PM‐AR70‐S510EXP Probe connection kit • Probe connection software


(For ARIETTA 70) (Not include Ver.4.1 software update)
PM‐AR70‐S510USA
• SOP method (same as F37)
PM‐AR60‐S510EXP Probe connection kit • Charged option
(For ARIETTA 60) • Components
PM‐AR60‐S510USA
• Installation manual
• Product Card
• CD manual (For Export, manual book is 
also included)

Please read installation manual carefully.

© Hitachi, Ltd. 2017. All rights reserved. 33


END

ARIETTA 70/70a/60  version 5.1 
Product explanation

Products marketing department
© Hitachi, Ltd. 2017. All rights reserved. 34