1
2
What is a transducer ?
(a fairly good definition)
prepared by g.bancale
5
…more
• Geiger counter: detects radiation levels by using a transducer called a
Geiger-Muller tube
electrical signal
prepared by g.bancale
8
Transducer
Input Output
sensor
I/F I/F
prepared by g.bancale
9
Conditioning +
Transducer
filtering
Sampling A/D P
Control logic
prepared by g.bancale
10
Precision Accuracy
prepared by g.bancale
12
TRANSDUCERS
• Temperature transducers
▫ Thermocouples
▫ Resistance - Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
13
TRANSDUCERS
• Temperature transducers
▫ Thermocouples
▫ Resistance - Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
14
What is a Thermocouple
It’s a temperature sensitive device which works
thanks to the Seebeck effect:
“a voltage is generated in a circuit containing
two different metals by keeping the junctions
between them at different temperatures”
prepared by g.bancale
15
please note the two wires (of two different metals) joined in the
junction.
prepared by g.bancale
17
prepared by g.bancale
19
More features:
• Type K ‘General Purpose' and low cost thermocouple, very popular
• Type J Limited range (-40 to +750°C), less popular than type
K.
• Type E High output (68 mV/°C) well suited to low
temperature (cryogenic) use
• Type N High stability and resistance to high temperature
oxidation, designed as an 'improved' type K, it’s
becoming more popular.
• Type T They are used for moist or sub-zero temperature
monitoring applications because of superior corrosion
resistance
21
Alloys used:
• Constantan: 55% Copper and 45% Nickel
• Cromel: 90% Ni + 10% Cr
• Alumel: 95% Ni + 2% Mn + 2% Al + 1% Silicon
• Nicrosil: 14.4%Cr +1.4 Silicon + 0.1% Mn + Ni
• Nisil: same as Nicrosil but different %
How much are thermocouples ?
• Type K Thermocouple (Exposed wire, fiberglass insulated) Tip
Diameter: 1.5 mm Tip Temperature: -60 to +350 °C Price $9.90
2 2
E c(T1 T2 ) k (T T )1 2
where
c and k = constants of the thermocouple materials
T1 = the temperature of the ‘hot’ junction
T2 = the temperature of the ‘cold’ or ‘reference’ junction
prepared by g.bancale
26
27
prepared by g.bancale
28
prepared by g.bancale
29
The circuit will provide accurate readings, but it is desirable to eliminate the ice bath
prepared by g.bancale
30
One way to do this is to replace the ice bath with another isothermal block
Cu Fe C Cu C
Thermocouple - applications
• Thermocouples are most suitable for measuring
over a large temperature range, up to 1800 K.
• They are less suitable for applications where
smaller temperature differences need to be
measured with high accuracy, for example the
range 0–100 °C with 0.1 °C accuracy. For such
applications, Thermistors and RTD’s are more
suitable.
prepared by g.bancale
33
TRANSDUCERS
• Temperature transducers
▫ Thermocouples
▫ Resistance - Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
34
prepared by g.bancale
Principle of operation
RTDs are manufactured from metals whose
resistance increases with temperature.
Within a limited temperature range, this
resistivity increases linearly with temperature:
where:
Rt = resistance at temperature t
R0= resistance at a standard temperature t0
= temperature coefficient of resistance (°C-1)
PRTs ( platinum RTDs )
• They are the most popular RTD type
• Nearly linear over a wide range of temperatures
• Small enough to have response times of a
fraction of a second
• They are among the most precise temperature
sensors available with resolution and
measurement uncertainties of ±0.1 °C or better
Why Platinum
• Chemical stability
• Availability in a pure form
• Highly reproducible electrical properties
• Platinum probes will read 100Ω at 0°C and at 100°C the
DIN grade (i.e. pure platinum intentionally contaminated with other platinum group
metals) platinum RTD will read 138.5Ω
• Only platinum RTDs have an international standard ( =
0.00385 Ω/Ω/°C )
How does an RTD look like ?
Nickel
Tungsten
Copper
Platinum
prepared by g.bancale
43
Construction of a PRTs
• The coiled element sensor, made by inserting the helical sensing wires into a
packed powder-filled insulating mandrel, provides a strain-free sensing element.
• All work is done manually under a microscope.
• Strain-free elements required for industrial measurements below –200°C.
•They also insure superior interchangeability and stability to the highest temp.
prepared by g.bancale
…more
•The thin film sensing element is made by depositing a thin layer of platinum
in a resistance pattern on a ceramic substrate.
•A glassy layer is applied for seal and protection.
Specifications
• Wiring configuration (2, 3, or 4-wire)
• Self-heating
• Stability
• Repeatability
• Response time
A. Wiring Configuration
Serious lead-wire resistance errors for
2/wire RTD especially in a 100Ω sensor.
TRANSDUCERS
• Temperature transducers
▫ Thermocouples
▫ Resistance - Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
53
Milestones of Thermistors
THERMal resISTORS
• 1833: negative temperature coefficient of silver
sulphide was first observed by M. Faraday
• Before 2003 only ceramic materials (a mix of
different metal oxides) were used for production
of Thermistors
• After 2003 AdSem started manufacturing of Si
and Ge high temperature NTC Thermistors with
better performance than any ceramic NTC
Thermistors
prepared by g.bancale
Types
• NTC - Negative Temperature Coefficient, used
mostly in temperature sensing
Temperature semiconductor resistance
• PTC - Positive Temperature Coefficient, used
mostly in electric current control
• Symbol
Key features
• the change in electrical resistance when subjected to a
corresponding change in body temperature is
▫ Predictable
▫ Precise
▫ Stable
• extremely high temperature coefficient of resistance
• typical temperature range of -100° to over +600° F
• Thermistors are generally accepted to be the most advantageous
sensor for many applications including temperature measurement
and control.
THERMISTOR APPLICATIONS
And…
And…
And…
And
How they look like
How they look like
63
Thermistor
prepared by g.bancale
Semiconductor Temp. Sensors
• The ordinary semiconductor diode may be used as a
temperature sensor
• The forward biased voltage across a diode has a
temperature coefficient of about 2.3mV/°C and is
reasonably linear
• The bias current should be held as constant as possible
using constant current source, or a resistor from a stable
voltage source
…more
• If two identical transistors are operated at different but
constant collector current densities, then the difference
in their base-emitter voltages is proportional to the
absolute temperature of the transistors
• The transistor sensor is used in diode mode by
connecting the base and collector together.
• VBE changes by approx. -2.2 mV/C°
• The result is a sensor
very low power
sensitive
linear
but electrically and mechanically delicate
IC temperature sensors
• The AD590 and the LM35 have traditionally
been the most popular devices, but over the last
few years better alternatives have become
available.
• They provide a current or voltage output signal
with relatively low output impedance
• Require an excitation power source and are
essentially linear
AD590:Product Description
•The AD590 is a two-terminal integrated circuit temperature transducer
• produces an output current proportional to absolute temperature(1µA/K
which means 298.2 µA 298.2K (25°C)
•The AD590 should be used in any temperature sensing application below
150°C
• low cost
• Linearization circuitry, precision voltage amplifiers, resistance measuring
circuitry and cold junction compensation are not needed in applying the
AD590
•The AD590 is particularly useful in remote sensing applications. The
device is insensitive to voltage drops over long lines due to its high
impedance current output.
LM 35:Product Description
• Calibrated directly in ° Celsius +10.0 mV/°C
• Rated for full -55° to +150°C range
• Suitable for remote applications
• Low cost due to wafer-level trimming
• Operates from 4 to 30 volts
• Low self-heating, 0.08°C in still air
• Nonlinearity only ±¼°C typical
• Low impedance output, 0.1 Ohm for 1 mA load
Price: Qty 1K+ $0.73
71
TRANSDUCER
• Temperature transducers
▫ Thermocouples
▫ Resistance-Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
72
Electrical signal
prepared by g.bancale
Principle of operation of an RPT
• The principle of the resistive position transducer is that
the measured quantity (i.e. the position of an object, or
the distance it has moved) causes a resistance change
in the sensing element.
• One type of displacement transducer uses a resistance
element with a sliding contact linked to the object being
monitored.
• Thus the resistance between the slider and one end of
the resistance element depends on the position of the
object.
74
prepared by g.bancale
Eout R2
E R1 R2
…more
• The output voltage depends on the wiper
position and therefore is a function of the shaft
position.
• The output voltage Eout is a fraction of E,
depending on the position of the wiper.
• The element is considered perfectly linear if
the resistance of the transducer is distributed
uniformly along the length of travel of wiper.
77
TRANSDUCER
• Temperature transducers
▫ Thermocouples
▫ Resistance-Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
78
Displacement transducers
• Capacitive transducer
• Inductive transducer
• Variable inductance transducer
prepared by g.bancale
79
Capacitive transducers
• The capacitance of a parallel-plate capacitor is
given by
o A
C
• ε = dielectric constant d
εo = 8.854 x 1o-12, in farad per meter
A = the area of the plate, in square meter
d = the plate spacing in meters
• Since C is inversely proportional to d, any
change in d will cause a change in C.
prepared by g.bancale
80
prepared by g.bancale
81
prepared by g.bancale
Self-Generating IT
• Self-Generating IT utilises the basic electrical
generator principle that: when there is relative
motion between conductor and magnetic field, a
voltage is induced in the conductor.
• An example of this is Tachometer that directly
converts speeds or velocity into an electrical
signal.
Tachometers
• Examples of a Common Tachometer
84
prepared by g.bancale
85
prepared by g.bancale
Passive type IT (LVDT)
• Passive inductive transducers require an
external source of power.
• The Differential transformer is a passive
inductive transformer, well known as Linear
Variable Differential Transformer (LVDT).
• It consists basically of a primary winding and two
secondary windings, wound over a hollow tube
and positioned so that the primary is between
two of its secondaries.
Linear Variable Differential Transformer
(LVDT)
• Some examples of LVDTs.
Linear Variable Differential Transformer
• An example of LVDT electrical wiring.
Linear Variable Differential Transformer
• An iron core slides within the tube and therefore
affects the magnetic coupling between the
primary and two secondaries.
• When the core is in the centre , the voltage
induced in the two secondaries is equal.
• When the core is moved in one direction of
centre, the voltage induced in one winding is
increased and that in the other is decreased.
Movement in the opposite direction reverses this
effects.
Linear Variable Differential Transformer
• In next figure, the winding
is connected ‘series opposing’
-that is the polarities of V1
and V2 oppose each other
• Consequently, when the core
is in the center so that V1=V2,
there is no voltage output,
Vo = 0V.
91
prepared by g.bancale
92
prepared by g.bancale
93
prepared by g.bancale
94
prepared by g.bancale
95
TRANSDUCER
• Temperature transducers
▫ Thermocouples
▫ Resistance-Temperature Detectors (RTD)
▫ Thermistors
• Resistive position transducers
• Displacement transducers
• Strain gauge
prepared by g.bancale
Strain gauge
• The Strain Gauge is an example of a passive
transducer that uses electrical resistance
variation in wires to sense the strain produced
by a force on the wire.
• It is a very versatile detector and transducer for
measuring weight, pressure, mechanical force
or displacement.
Strain gauge: how they look like
The construction of a bonded strain gauge shows a
fine wire looped back and forth on a mounting plate,
which is usually cemented to the element that
undergoing stress.
100
Strain gauge
L
From the equation of resistance, R
A
R = resistance
ρ = specific resistance of the conductor material
L = the length of the conductor in meters
A = the area of the conductor in square meters
When a strain produced by a force is applied on
the wires, L increase and A decrease.
prepared by g.bancale
101
Strain gauge
L increase A decrease
L
From the equation of resistance, R
A
R increase
prepared by g.bancale
102
R / R
K
L / L
K = the gauge factor
R = the initial resistance in ohms (without strain)
ΔR = the change of initial resistance in ohms
L = the initial length in meters (without strain)
ΔL = the change of initial length in meters
prepared by g.bancale
103
prepared by g.bancale
104
R / R
K
G
prepared by g.bancale
105
Stress equation
For many common materials, there is a constant
ratio between stress and strain. Stress is defined
as the internal force per unit area.
F
S
A
S = the stress in kilograms per square meter
F = the force in kilograms
A = the area in square meters
prepared by g.bancale
106
Young’s modulus
The constant of proportionality between stress
and strain for the curve is known as the modulus
of elasticity of the materials
S
E
G
E = Young’s modulus in kilograms per square
meter
S = the stress in kilograms per square meter
G = the strain (no unit)
prepared by g.bancale
Measuring Circuits
Measuring Circuits
Application & Installation
• The output of a strain gage circuit is a very low-level voltage signal
requiring a sensitivity of 100 microvolts or better.
• The low level of the signal makes it particularly susceptible to
unwanted noise from other electrical devices.
• Capacitive coupling caused by the lead wires' running too close to
AC power cables or ground currents are potential error sources in
strain measurement.
• Other error sources may include magnetically induced voltages
when the lead wires pass through variable magnetic fields, parasitic
(unwanted) contact resistances of lead wires, insulation failure, and
thermocouple effects at the junction of dissimilar metals. The sum of
such interferences can result in significant signal degradation.
Evaluation test on Transducers
2. two important parameters of a transducer are Static and Dynamic response. Can you
5. why should you use an ice bath when measuring temperature with a thermocouple?
8. how can you minimize lead - wire resistance errors for RTD
9. an ordinary semiconductor diode may be used as a temperature sensor, can you explain
how?
10. LM35 is by far the most popular temperature sensor among students. Can you remember
why?
12. LVDT’s (Linear Variable Differential Transformer) are passive type inductive displacement
14. what is the equation that explains the operation of a strain gauge
15. the gauge factor is indicated as K in the following formula. Can you tell the meaning of the