Preamble British Board of Agrément (BBA) Certificate
This document has been compiled to give Kingspan Product summary and guidance on
Steel Building Solutions customers guidance on the specification, installation, maintenance and
correct application of design and engineering durability
principles of the Kingframe Steel Framing System.
Kingframe SFS Design Guide
This document should be read alongside our other Detailed and Basic Design Services - an
publications which can be found at: overview of the services offered by Kingspan
www.kingspanpanels.co.uk/sbs Steel Building Solutions
Contents
1 SYSTEM OVERVIEW ........................................................................................................................... 1
1.1 Overview .................................................................................................................................. 1
1.2 Design Considerations ............................................................................................................. 1
1.3 Design Guidance...................................................................................................................... 2
1.4 Construction Design Management........................................................................................... 2
2 SFS STANDARD COMPONENTS ....................................................................................................... 3
2.1 Basic Components ................................................................................................................... 3
2.2 Kingspan Section Range ......................................................................................................... 4
2.3 Secondary Products ................................................................................................................. 4
2.4 ‘C’ Section Range .................................................................................................................... 5
2.4.1 To BS 5950-5:1998 ..................................................................................................... 5
2.4.2 To BS EN 1993-1-3:2006 ............................................................................................ 6
2.5 ‘U’ Section Range .................................................................................................................... 7
2.5.1 To BS 5950-5:1998 ..................................................................................................... 7
2.5.2 To BS EN 1993-1-3:2006 ............................................................................................ 8
2.6 Ancillary Products .................................................................................................................... 9
2.7 Span Tables ............................................................................................................................. 9
3 SFS STANDARD FIXINGS ................................................................................................................ 16
3.1 Recommended Fixings .......................................................................................................... 16
4 INFILL SFS ......................................................................................................................................... 20
4.1 Design Principles ................................................................................................................... 20
4.1.1 General Stud Design & Construction ........................................................................ 20
4.1.2 Structural Openings ................................................................................................... 20
4.1.3 Splicing of Sections ................................................................................................... 20
4.1.4 Deflection Head Details ............................................................................................. 20
4.1.5 Mid Span Restraint (Detail B.01) ............................................................................... 21
4.1.6 Cladding Treatments & Boarding .............................................................................. 21
rd
4.1.7 2/3 Minimum Bearing............................................................................................... 21
4.1.8 Service Holes............................................................................................................. 22
4.1.9 Curved Walling .......................................................................................................... 22
4.1.10 Braced Bays .............................................................................................................. 23
4.1.11 Parapets and Downstands ........................................................................................ 23
4.1.12 Ribbon Windows ........................................................................................................ 23
4.1.13 Brise Soleil ................................................................................................................. 23
4.1.14 Kingposts ................................................................................................................... 24
4.1.15 Oversail Cleats .......................................................................................................... 24
5 OVERSAIL SFS .................................................................................................................................. 25
i
5.1 Design Principles ................................................................................................................... 25
5.1.1 General Stud Design & Construction ........................................................................ 25
5.1.2 Deflection Conditions ................................................................................................. 25
5.1.3 Splicing of Sections ................................................................................................... 26
5.1.4 Structural Openings ................................................................................................... 26
5.1.5 Mid Span Restraint (Detail B.01) ............................................................................... 26
5.1.6 Cladding Treatments & Boarding (Detail E.01 & E.02) ............................................. 26
5.1.7 Service Holes............................................................................................................. 26
5.1.8 Curved Walling .......................................................................................................... 26
5.1.9 Braced Bays .............................................................................................................. 26
5.1.10 Parapets and Downstands ........................................................................................ 26
5.1.11 Ribbon Windows ........................................................................................................ 26
5.1.12 Brise Soleil ................................................................................................................. 26
5.1.13 Fixings ....................................................................................................................... 26
6 STANDARD DETAILS........................................................................................................................ 27
6.1 ‘A’ Series – Basic Connections .............................................................................................. 27
6.2 ‘B’ Series – Construction Details............................................................................................ 53
6.3 ‘C’ Series – Opening Construction ......................................................................................... 64
6.4 ‘D’ Series – Oversail Details .................................................................................................. 87
6.5 ‘E’ Series – Boarding Details ............................................................................................... 101
6.6 ‘F’ Series – Finishes Details................................................................................................. 104
6.7 ‘G’ Series – Building Details................................................................................................. 106
7 CLADDING TREATMENTS ............................................................................................................. 115
7.1 Introduction .......................................................................................................................... 115
7.2 Masonry ............................................................................................................................... 115
7.3 Insulated Render .................................................................................................................. 115
7.4 Terracotta Rainscreen ......................................................................................................... 116
7.5 Timber Rainscreen ............................................................................................................... 116
7.6 Metal Rainscreen ................................................................................................................. 116
7.7 Stone Panels ........................................................................................................................ 116
8 COSHH & TECHNICAL DATASHEETS .......................................................................................... 117
8.1 General Specification Notes ................................................................................................ 117
8.2 COSHH Datasheet ............................................................................................................... 118
9 SUPPORT SERVICES...................................................................................................................... 120
9.1 Material Ordering & Production Enquiries ........................................................................... 120
9.2 Technical Enquiries .............................................................................................................. 120
9.3 Sales & Commercial Enquiries ............................................................................................ 120
9.4 Site Support Enquiries ......................................................................................................... 120
ii
External References
Publications
BS 5950 Structural Use of Steelwork in Building - Part 5; Code of Practice for Design of Cold Formed Thin
Gauge Sections
BS 6399 Series; Actions Buildings
BS EN 1990 Series; Basis for structural design
BS EN 1991 Series; Actions on structures
BS EN 1993 Series; Design of steel structures
National Structural Steelwork Specification (NSSS) Fifth Edition, The British Constructional Steelwork
Association (BCSA)
SCI Guide P125; Building design using cold formed steel sections: Worked examples to BS 5950: Part 5:
1987
SCI Guide P301; Building design using cold formed steel sections: Light steel framing in residential
construction
SCI Guide P262; Building design using cold formed steel sections: Durability of Light Steel Framing in
Residential Building
BS 7364:1990 Specification for galvanized steel studs and channels for stud and sheet partitions and linings
using screw fixed gypsum wallboards
BS 8000 Series; Workmanship on building site; Codes of practice
BS EN 10346; Continuously hot-dip coated steel flat products. Technical delivery conditions.
Building Regulations; Approved Documents
Industry/Regulatory Bodies
Liabilities
This document does not serve as a specification without prior written consultation with a Kingspan Steel
Building Solutions engineer. Details and information provided do not constitute an extension of any warranty or
acceptance of liability by Kingspan Steel Building Solutions unless used under the specific terms of the
Kingspan Steel Building Solutions Detailed Design Service. Kingspan Steel Building Solutions will not be held
liable for any consequential losses incurred by any party through the use of this document. Customers of
Kingspan Steel Building Solutions accept that the information provided in this document is supplied for general
guidance purposes only.
Unauthorised Distribution
This document is provided in good faith to Kingspan customers to assist in the design of the SFS product. It
should not be distributed to third parties without the prior written consent of Kingspan Steel Building Solutions.
iii
for low rise buildings. This is beyond the scope of
1 SYSTEM OVERVIEW this manual but information is available on request
from Kingspan.
1.1 Overview
1.2 Design Considerations
The Kingframe Steel Framing System (SFS) is a
component supply structural stud façade system Design considerations affect the performance of the
commonly used in two main methods: Infill and SFS systems. Some of these are described below;
Oversail. The system consists of C shaped studs
and U shaped tracks designed on a project specific Design Life
basis to form the inner leaf of an external façade. SFS sections are hot dip galvanised with a 20μm
zinc coating and are intended for warm frame
Both systems are constructed on-site and must be construction. This is to say that the SFS is always
designed and installed to relevant codes and fully enclosed within the warm envelope of the
standards. Liability for the quality and accuracy of facade by insulation applied to the external face of
the installation rests with the installation contractor the SFS.
and not Kingspan Steel Building Solutions.
Where parapets, upstands, downstands, etc. are
SFS has been extensively used in construction formed in SFS, they should be insulated to all
projects covering residential flats, apartments, exposed faces in order to satisfy this requirement.
healthcare and educational developments,
commercial developments, public buildings and Assuming that the SFS is maintained within a warm
1
industrial properties. frame environment, current industry guidance is
that a design life of 250 years can be expected.
Sections are supplied to site as individual Where the SFS is installed in a cold frame
components and fully assembled in-situ. This is an environment (low risk of water ingress, some risk of
advantage where site access/craneage is restricted. condensation), this reduces to 50-60 years.
Components can be supplied in final required
lengths or standard lengths cut to suit on site. By SFS may be used in potentially corrosive
cutting to length on site, construction tolerances in environments, such as swimming pool buildings,
structures can be fully accommodated. providing that the internal finishes are designed to
protect the frame. There are a number of boards
Infill Systems are typically supported at the specifically designed for swimming pools, such as
2
slab edge between hot-rolled steel or concrete. Promat Masterboard which is a moisture resistant
This allows insulation and external finishes to lining system for swimming pool applications.
be installed outside the main structural frame if
the correct tolerance scheme is adopted. The Live Load Deflection
system is suitable for both low and high-rise Every structure, whether concrete or steel, will
construction. A deflection allowance is required move when placed under load during normal use.
at each floor level. This is anticipated within the design of the building
Oversail Systems are fitted outside the line of by the engineers and must be accommodated
the structural frame using support cleats at within the SFS system. This movement is in the
each floor level with connections designed to vertical plane and is normally at its maximum
allow slab deflection. It is particularly suited to displacement at mid-span between vertical supports
situations where cladding materials are e.g. columns. The expected total movement can be
3
sensitive to differing movement of the main calculated by using the formula below ;
frame. Adequate base support must be Maximum deflection = Span between supporting
provided to accommodate vertical loading. columns ÷ 360
Both systems achieve early weather protection of The Kingspan Steel Building Solutions standard
the building allowing other internal fitting trades to SFS System can achieve a maximum deflection
work inside the structure and removing external tolerance at the head of an infill frame of 25mm.
cladding from the critical path. Furthermore, these Conditions that have a greater live load deflection
systems also provide lateral support to most value must be referred to Kingspan Steel Building
cladding materials including masonry, profiled metal
sheets, proprietary panels, insulated render 1
P262 Durability of Light Steel Framing in Residential Building.
systems, terracotta and timber rain screen systems. Second Edition. The Steel Construction Institute, 2009
2
It should be noted that SFS is not intended to This is provided as an example of available boarding only and
does not form a specification or recommendation from Kingspan.
provide vertical support for masonry facades. Frame linings are beyond the scope of Kingspan’s design and
supply.
3
It is also possible to design Kingspan SFS sections Assumes a design deflection limit under imposed load of
to form the primary load bearing structural framing span/360 for the primary frame. This should be confirmed with
the primary frame engineer
1
Solutions technical department. In oversail framing, Building Solutions will identify potential CDM risks
the deflection tolerance is generally accommodated to the named individual within the project team. It is
within the supporting bracketry and is therefore not the responsibility of the Installer to provide the
limited by the SFS. contact details of this individual to Kingspan Steel
Building Solutions.
Building Regulation Requirements
The installer should refer to the main contractor and When Kingspan Steel Building Solutions recognises
the architect to ensure that the requirements under a hazard to health and safety that cannot be
Building Regulations for areas such as air tightness, avoided through design, the hazard and proposed
fire resistance, thermal bridging and acoustic mitigation is identified on the drawings using the
protection are met before construction begins. following symbol:
When clad in suitable materials and linings, SFS
constructions can achieve performances in excess
to those required by the current regulations. As the
performance is governed by the cladding and
linings designed and supplied by others, Kingspan Figure 1 - CDM Hazard Identification
Steel Building Solutions cannot provide specific
guidance in these areas. If you require further A description of the hazard is then written into the
guidance, please consider use of our “full through legend of the drawings. The most frequently
wall system” - KingBuild System (KBS). identified specific risks are:
Multiple different stud systems / gauges
1.3 Design Guidance specified on drawing – installer to implement
sufficient QA checks to ensure compliance with
Kingspan Steel Building Solutions offer guidance on scheme. Consider requesting Kingspan site
specific issues that affect the design, specification inspection.
and installation of the SFS system. Detailed Long span studs – installer to prepare
guidance on issues can be found at: adequate method statement for handling of
http://www.kingspanpanels.co.uk/sbs. high span studs. Consider mechanical lifting
equipment.
Guidance notes published by Kingspan Steel Heavy lifting – installer to prepare adequate
Building Solutions are recommendations and cover method statement for handling heavy materials.
the following main areas; SFS & Setting Out; SFS &
Consider mechanical lifting equipment.
Sustainability; SFS & Thermal Performance, SFS & Large structural openings – lintels, cills and
Deflection; SFS & Wind Loadings.
jambs must be formed with continuous (NOT
spliced) members. Installer to ensure specific
section lengths ordered as required.
Edge protection required – SFS cill too low to
1.4 Construction Design Management offer edge protection to BS EN 13374:2004.
The Construction Design Management (CDM) Main contractor to provide additional edge
regulations 2007 redefined the responsibilities and protection system.
guidance for system suppliers and designers on all
construction projects in the UK. Wherever possible, For further information, please refer to the SFS
Kingspan Steel Building Solutions will take Designer’s Risk Assessment and the SFS
measures to design out any risk to the installer Installation Manual.
during construction of the SFS. Kingspan Steel
2
2 SFS STANDARD COMPONENTS
2.1 Basic Components
‘C’ section and ‘U’ section components are formed from pre-hot dipped galvanised steel to BS EN 10346:2009,
2 2
Grade S390 + zinc coating Z275 g/m . Guaranteed minimum yield strength = 390N/mm .
Ancillary components including Angles, Cleats, Brackets and ‘Z’ Bars are formed from pre-hot dipped
2
galvanised steel to BS EN 10346:2009, Grade S275 + zinc coating Z275 g/m . Guaranteed minimum yield
2
strength = 275N/mm .
Flat Straps
N.B. All thicknesses given in this manual are the overall nominal thickness, including galvanised coating.
3
2.2 Kingspan Section Range
All sections and ancillaries provided by Kingspan have a unique reference. The table below gives a guide to
what these references mean;
FS 100 ~ 120
Flat Strap 100mm width (A) ~ 1.2mm thickness (T)
B 135 105 60
Bracket 135mm leg (A) 105mm leg (B) 6.0mm thickness (T)
L 70 50 20
Angle Section 70mm leg (A) 50mm leg (B) 2.0mm thickness (T)
L 70 50 20 L
Angle Section 70mm leg (A) 50mm leg (B) 2.0mm thickness (T) Stock Lengths 3.0m
The table below gives the sections and products other than standard ‘C’ and ‘U’ sections manufactured by
Kingspan:
T
Section Ref. Weight (kg/m) A (mm) B (mm) C (mm)
(mm)
Angles & Cleats
L70502 ~ 50 50 70 2.0
L100502 ~ 50 50 100 2.0
L150502 ~ 50 50 150 2.0
L200502 ~ 50 50 200 2.0
L250502 ~ 50 50 250 2.0
L300502 ~ 50 50 300 2.0
L50502L ~ 50 50 3000 2.0
L100502L ~ 100 50 3000 2.0
L1501002L ~ 150 100 3000 2.0
Brackets
B13510560* ~ 135 105 95 6.0
B808030* ~ 80 80 80 3.0
KHC9524A* ~ 60 80 95 2.4
KHC9528B* ~ 135 80 95 2.8
Strap Products
FS10012 ~ 100 ~ ~ 1.2
FS3809 ~ 38 ~ ~ 0.9
‘Z’ Bar Products
Z40404016 ~ 40 40 40 1.6
4
2.4 ‘C’ Section Range4
2.4.1 To BS5950-5:1998
Dimensions Gross Section Major Axis Bending Minor Axis Bending Compression
Internal Galv Ixx Zxx Mcy Web Mcy Web
Section Mass W F Li T Area Ixx Iyy rx ry Zxx Zyy P0 es
radius coating 2 4 4 3 3 Effective Effective 2 Comp Tension Q
Reference (kg/m) (mm) (mm) (mm) (mm) (mm ) (cm ) (cm ) (cm) (cm) (cm ) (cm ) (N/mm ) (mm)
ri (mm) (mm) (cm4) (cm3) (kNm) (kNm)
C070050150 2.09 70.00 50.00 10.00 1.50 3.00 0.04 266.34 22.91 9.08 2.92 1.84 6.69 2.94 22.49 6.48 390.00 1.53 1.15 1.18 0.89
C070070200 3.48 70.00 70.00 14.00 2.00 4.00 0.04 442.83 39.88 29.83 2.97 2.57 11.73 7.42 38.95 11.25 390.00 3.70 2.89 0.41 0.93
C100050120 1.98 100.00 50.00 10.00 1.20 2.40 0.04 252.06 41.32 8.31 4.07 1.82 8.36 2.48 38.95 7.59 366.21 1.13 0.97 4.36 0.67
C100060120 2.21 100.00 60.00 12.00 1.20 2.40 0.04 280.86 47.69 13.70 4.15 2.22 9.65 3.53 42.61 8.02 366.21 1.51 1.34 4.65 0.61
C100070120 2.43 100.00 70.00 14.00 1.20 2.40 0.04 309.66 53.99 20.83 4.21 2.61 10.93 4.75 45.62 8.30 366.21 1.93 1.72 4.77 0.56
C100070160 3.20 100.00 70.00 14.00 1.60 3.20 0.04 407.57 71.57 27.47 4.19 2.59 14.55 6.30 66.30 12.79 385.54 2.92 2.45 3.39 0.73
C100070200 3.95 100.00 70.00 14.00 2.00 4.00 0.04 502.83 88.65 33.84 4.17 2.58 18.09 7.79 86.50 17.35 390.00 3.98 3.04 2.04 0.87
C125050120 2.22 125.00 50.00 10.00 1.20 2.40 0.04 282.06 68.86 8.92 4.97 1.79 11.12 2.54 65.28 10.20 347.37 1.14 0.98 5.83 0.60
C125060120 2.44 125.00 60.00 12.00 1.20 2.40 0.04 310.86 78.98 14.75 5.08 2.19 12.76 3.63 71.25 10.80 347.37 1.52 1.36 6.35 0.56
C125070120 2.67 125.00 70.00 14.00 1.20 2.40 0.04 339.66 89.01 22.48 5.16 2.59 14.38 4.89 76.30 11.21 347.37 1.94 1.76 6.62 0.52
C125070160 3.52 125.00 70.00 14.00 1.60 3.20 0.04 447.57 118.22 29.65 5.14 2.58 19.16 6.48 110.10 17.03 371.52 2.93 2.51 5.31 0.68
C125070200 4.35 125.00 70.00 14.00 2.00 4.00 0.04 552.83 146.69 36.54 5.12 2.56 23.85 8.02 143.12 22.89 385.82 4.01 3.13 3.88 0.80
C150050120 2.45 150.00 50.00 10.00 1.20 2.40 0.04 312.06 105.11 9.42 5.85 1.75 14.13 2.59 100.53 13.16 328.52 1.14 1.00 7.00 0.55
C150060120 2.67 150.00 60.00 12.00 1.20 3.00 0.04 339.62 119.85 15.63 5.98 2.16 16.11 3.70 109.13 13.87 328.52 1.53 1.38 7.75 0.52
C150070120 2.91 150.00 70.00 14.00 1.20 2.40 0.04 369.66 134.48 23.87 6.08 2.56 18.08 4.99 116.71 14.41 328.52 1.95 1.78 8.21 0.48
C150070160 3.83 150.00 70.00 14.00 1.60 3.20 0.04 487.57 178.84 31.49 6.07 2.55 24.10 6.62 167.29 21.61 357.51 2.94 2.55 6.97 0.63
C150070200 4.74 150.00 70.00 14.00 2.00 4.00 0.04 602.83 222.19 38.81 6.05 2.53 30.03 8.19 216.98 28.87 374.66 4.02 3.19 5.56 0.74
C200050120 2.92 200.00 50.00 10.00 1.20 2.40 0.04 372.06 207.35 10.17 7.53 1.67 20.86 2.65 201.24 19.91 290.82 1.16 1.01 8.73 0.47
C200060120 3.15 200.00 60.00 12.00 1.20 2.40 0.04 400.86 233.95 16.99 7.71 2.08 23.54 3.80 218.12 21.08 290.82 1.55 1.40 9.89 0.45
C200070120 3.38 200.00 70.00 14.00 1.20 2.40 0.04 429.66 260.38 26.07 7.86 2.49 26.20 5.14 232.06 21.86 290.82 1.98 1.81 10.72 0.42
C200070160 4.46 200.00 70.00 14.00 1.60 3.20 0.04 567.57 346.86 34.40 7.84 2.47 34.97 6.82 328.47 32.05 329.48 2.97 2.61 9.57 0.54
C200070200 5.52 200.00 70.00 14.00 2.00 4.00 0.04 702.83 431.67 42.40 7.82 2.45 43.60 8.44 423.38 42.26 352.36 4.04 3.29 8.24 0.64
C250070120 3.85 250.00 70.00 14.00 1.20 2.40 0.04 489.66 438.95 27.75 9.57 2.41 35.29 5.25 401.63 30.74 253.13 2.01 1.83 12.58 0.38
C250070160 5.09 250.00 70.00 14.00 1.60 3.20 0.04 647.57 585.39 36.61 9.55 2.39 47.13 6.95 561.54 44.15 301.45 3.00 2.64 11.49 0.48
C250070200 6.31 250.00 70.00 14.00 2.00 4.00 0.04 802.83 729.34 45.11 9.53 2.37 58.82 8.61 718.82 57.48 330.05 4.07 3.36 10.21 0.57
C300070200 7.10 300.00 70.00 14.00 2.00 4.00 0.04 902.83 1127.44 47.24 11.18 2.29 75.67 8.73 1115.50 74.42 307.74 4.11 3.40 11.71 0.51
4
Please refer to web site to ensure you are using an up to date copy of the section properties. Further sections are available upon request. Please contact your Area Sales Manager for further details.
5
2.4.2 To BS-EN-1993-1-3:2006
Dimensional Gross Section Major axis bending Minor Axis Bending Compression
Mc,z
Internal Galv Gross Iyy in Wel,yy in Mcz Web
Section Mass W F Li T δ Iyy Izz iy iz Wel,yy Wel,zz Web eNy
radius coating 3 Area 4 4 3 3 Bending Bending Tension Q
Reference (Kg/m) (mm) (mm) (mm) (mm) (x10 ) 2 (cm ) (cm ) (cm) (cm) (cm ) (cm ) 4 3 Comp (mm)
ri (mm) (mm) (mm ) (cm ) (cm ) (kNm)
(kNm)
C070050150 2.09 70.00 50.00 10.00 1.50 3.00 0.04 28.04 266.34 22.91 9.08 2.96 1.86 6.31 2.78 20.91 5.73 1.46 0.91 -2.07 0.76
C070070200 3.48 70.00 70.00 14.00 2.00 4.00 0.04 29.91 442.83 39.88 29.83 3.02 2.61 11.03 6.98 36.25 9.94 3.62 2.38 -4.63 0.82
C100050120 1.98 100.00 50.00 10.00 1.20 2.40 0.04 19.18 252.06 41.33 8.31 4.11 1.84 8.04 2.39 35.30 6.49 1.11 0.65 -2.07 0.54
C100060120 2.21 100.00 60.00 12.00 1.20 2.40 0.04 17.26 280.86 47.69 13.70 4.18 2.24 9.32 3.41 38.52 6.85 1.49 0.88 -3.97 0.51
C100070120 2.43 100.00 70.00 14.00 1.20 2.40 0.04 15.68 309.66 53.99 20.83 4.24 2.63 10.59 4.61 41.61 7.19 1.91 1.13 -6.06 0.48
C100070160 3.20 100.00 70.00 14.00 1.60 3.20 0.04 21.04 407.57 71.58 27.48 4.23 2.62 13.94 6.03 60.64 11.07 2.83 1.75 -4.81 0.61
C100070200 3.95 100.00 70.00 14.00 2.00 4.00 0.04 26.46 502.83 88.65 33.85 4.23 2.61 17.13 7.38 80.02 15.23 3.80 2.38 -3.10 0.73
C125050120 2.22 125.00 50.00 10.00 1.20 2.40 0.04 17.19 282.06 68.87 8.93 5.02 1.81 10.74 2.46 56.57 8.08 1.12 0.62 -0.82 0.49
C125060120 2.44 125.00 60.00 12.00 1.20 2.40 0.04 15.62 310.86 78.99 14.76 5.12 2.21 12.36 3.52 61.69 8.56 1.51 0.85 -2.63 0.46
C125070120 2.67 125.00 70.00 14.00 1.20 2.40 0.04 14.32 339.66 89.02 22.49 5.20 2.61 13.97 4.75 66.57 9.01 1.93 1.12 -4.54 0.44
C125070160 3.52 125.00 70.00 14.00 1.60 3.20 0.04 19.20 447.57 118.23 29.66 5.19 2.60 18.43 6.23 99.92 14.59 2.87 1.71 -3.83 0.55
C125070200 4.35 125.00 70.00 14.00 2.00 4.00 0.04 24.14 552.83 146.70 36.55 5.19 2.59 22.70 7.63 131.88 20.01 3.88 2.34 -1.91 0.67
C150050120 2.45 150.00 50.00 10.00 1.20 2.40 0.04 15.57 312.06 105.13 9.42 5.89 1.76 13.69 2.51 83.20 9.66 1.13 0.60 0.16 0.44
C150060120 2.67 150.00 60.00 12.00 1.20 3.00 0.04 17.84 339.62 119.87 15.63 6.03 2.18 15.54 3.57 90.80 10.30 1.52 0.84 -1.48 0.42
C150070120 2.91 150.00 70.00 14.00 1.20 2.40 0.04 13.18 369.66 134.50 23.88 6.12 2.58 17.60 4.86 97.74 10.84 1.94 1.11 -3.23 0.40
C150070160 3.83 150.00 70.00 14.00 1.60 3.20 0.04 17.66 487.57 178.86 31.50 6.12 2.57 23.25 6.39 148.38 17.82 2.90 1.66 -2.48 0.51
C150070200 4.74 150.00 70.00 14.00 2.00 4.00 0.04 22.19 602.83 222.21 38.82 6.12 2.56 28.70 7.83 199.20 25.15 3.93 2.30 -0.89 0.61
C200050120 2.92 200.00 50.00 10.00 1.20 2.40 0.04 13.10 372.06 207.38 10.18 7.58 1.68 20.32 2.58 154.16 12.96 1.14 0.58 1.65 0.37
C200060120 3.15 200.00 60.00 12.00 1.20 2.40 0.04 12.17 400.86 233.98 16.99 7.76 2.09 22.97 3.71 167.27 13.78 1.53 0.82 0.32 0.36
C200070120 3.38 200.00 70.00 14.00 1.20 2.40 0.04 11.37 429.66 260.42 26.08 7.91 2.50 25.60 5.03 179.29 14.50 1.96 1.08 -1.09 0.34
C200070160 4.46 200.00 70.00 14.00 1.60 3.20 0.04 15.22 567.57 346.91 34.41 7.90 2.49 33.91 6.61 272.49 23.64 2.94 1.57 -0.33 0.44
C200070200 5.52 200.00 70.00 14.00 2.00 4.00 0.04 19.11 702.83 431.72 42.40 7.90 2.48 41.94 8.12 376.30 34.85 3.99 2.20 0.71 0.52
C250070120 3.85 250.00 70.00 14.00 1.20 2.40 0.04 9.99 489.66 439.00 27.75 9.62 2.42 34.58 5.14 287.20 18.18 1.97 1.05 0.53 0.30
C250070160 5.09 250.00 70.00 14.00 1.60 3.20 0.04 13.37 647.57 585.46 36.61 9.61 2.40 45.88 6.77 439.10 29.66 2.96 1.54 1.33 0.38
C250070200 6.31 250.00 70.00 14.00 2.00 4.00 0.04 16.78 802.83 729.42 45.12 9.61 2.39 56.85 8.32 605.92 43.37 4.03 2.10 2.23 0.45
C300070200 7.10 300.00 70.00 14.00 2.00 4.00 0.04 14.96 902.83 1127.58 47.24 11.27 2.31 73.41 8.47 894.19 51.85 4.05 2.00 3.48 0.40
6
2.5 ‘U’ Section Range5
2.5.1 To BS5950-5:1998
Dimensions Gross Section Major Axis Bending Minor Axis Bending Compression
Internal Galv Ixx Zxx Mcy Web Mcy Web
Section Mass W F Li T Area Ixx Iyy rx ry Zxx Zyy P0 es
radius coating Effective Effective Comp Tension Q
Reference (kg/m) (mm) (mm) (mm) (mm) (mm2) (cm4) (cm4) (cm) (cm) (cm3) (cm3) 4 3 (N/mm2) (mm)
ri (mm) (mm) (cm ) (cm ) (kNm) (kNm)
U074055150 2.10 74.00 55.00 ~ 1.50 3.00 0.04 266.67 25.45 8.55 3.10 1.80 7.02 2.25 19.49 4.59 390.00 1.43 0.32 -4.27 0.49
U074069180 2.89 74.00 69.00 ~ 1.80 3.60 0.04 368.17 36.76 18.88 3.17 2.27 10.18 4.12 27.52 6.39 390.00 2.61 0.56 -3.42 0.56
U074069200 3.20 74.00 69.00 ~ 2.00 4.00 0.04 407.42 40.64 20.93 3.16 2.27 11.29 4.57 31.51 7.46 390.00 2.95 0.74 -2.14 0.60
U104055120 1.97 104.00 55.00 ~ 1.20 2.40 0.04 250.83 43.83 7.64 4.23 1.76 8.53 1.89 32.69 5.43 363.20 1.05 0.18 -7.12 0.31
U104067180 3.26 104.00 67.00 ~ 1.80 3.60 0.04 414.97 76.40 19.54 4.30 2.18 14.95 4.12 58.75 9.88 389.92 2.57 0.57 -6.42 0.44
U104067200 3.63 104.00 67.00 ~ 2.00 4.00 0.04 461.42 84.61 21.66 4.30 2.17 16.59 4.57 67.06 11.46 390.00 2.96 0.75 -5.35 0.48
U129055120 2.21 129.00 55.00 ~ 1.20 2.40 0.04 280.83 71.69 8.15 5.11 1.72 11.22 1.95 54.76 7.44 344.35 1.06 0.19 -7.04 0.26
U129068180 3.64 129.00 68.00 ~ 1.80 3.60 0.04 463.57 125.70 21.79 5.23 2.18 19.76 4.37 97.81 13.37 377.50 2.64 0.58 -7.55 0.37
U129068200 4.04 129.00 68.00 ~ 2.00 4.00 0.04 513.42 139.34 24.16 5.22 2.17 21.94 4.85 111.17 15.40 384.03 3.05 0.76 -6.77 0.41
U154055120 2.44 154.00 55.00 ~ 1.20 2.40 0.04 310.83 108.13 8.56 5.97 1.68 14.15 1.99 84.30 9.73 325.50 1.06 0.19 -6.74 0.23
U154067180 3.97 154.00 67.00 ~ 1.80 3.60 0.04 504.97 186.42 22.06 6.10 2.10 24.50 4.35 147.85 17.15 365.07 2.58 0.58 -7.64 0.32
U154067200 4.40 154.00 67.00 ~ 2.00 4.00 0.04 559.42 206.76 24.46 6.10 2.10 27.21 4.83 167.70 19.68 372.88 2.98 0.76 -7.08 0.35
U204055120 2.91 204.00 55.00 ~ 1.20 2.40 0.04 370.83 210.35 9.18 7.63 1.59 20.74 2.05 169.67 15.08 287.81 1.08 0.19 -5.43 0.20
U204067180 4.68 204.00 67.00 ~ 1.80 3.60 0.04 594.97 359.00 23.83 7.81 2.01 35.51 4.49 291.95 25.98 340.23 2.60 0.58 -7.40 0.26
U204067200 5.18 204.00 67.00 ~ 2.00 4.00 0.04 659.42 398.47 26.42 7.80 2.01 39.45 4.99 330.05 29.64 350.57 3.00 0.77 -7.05 0.28
U254055120 3.39 254.00 55.00 ~ 1.20 2.40 0.04 430.83 357.74 9.63 9.24 1.52 28.30 2.09 296.55 21.50 250.11 1.09 0.19 -4.22 0.18
U254067180 5.38 254.00 67.00 ~ 1.80 3.60 0.04 684.97 605.14 25.14 9.46 1.93 47.99 4.59 502.46 36.37 315.38 2.62 0.58 -5.89 0.23
U254067200 5.97 254.00 67.00 ~ 2.00 4.00 0.04 759.42 672.01 27.87 9.45 1.92 53.33 5.10 566.58 41.32 328.26 3.02 0.77 -5.55 0.26
U304067200 6.76 304.00 67.00 ~ 2.00 4.00 0.04 859.42 1039.62 28.99 11.06 1.85 68.85 5.18 889.85 54.71 305.95 3.04 0.77 -4.35 0.23
5
Please refer to web site to ensure you are using an up to date copy of the section properties. Further sections are available upon request. Please contact your Area Sales Manager for further details.
7
2.5.2 To BS-EN-1993-1-3:2006
Dimensional Gross Section Major axis bending Minor Axis Bending Compression
Internal Galv Gross Iyy in Wel,yy in Mc,z Web Mcz Web
Section Mass W F Li T δ Iyy Izz iy iz Wel,yy Wel,zz eNy
radius coating Area Bending Bending Comp Tension Q
Reference (Kg/m) (mm) (mm) (mm) (mm) (x103) 2 (cm4) (cm4) (cm) (cm) (cm3) (cm3) 4 3 (mm)
ri (mm) (mm) (mm ) (cm ) (cm ) (kNm) (kNm)
U074055150 2.10 74.00 55.00 ~ 1.50 3.00 0.04 0.00 266.67 25.45 8.55 3.10 1.80 7.02 2.25 17.22 3.84 1.37 0.35 -12.05 0.50
U074069180 2.89 74.00 69.00 ~ 1.80 3.60 0.04 0.00 368.17 36.76 18.89 3.17 2.27 10.18 4.12 23.81 5.19 2.51 0.66 -17.00 0.51
U074069200 3.20 74.00 69.00 ~ 2.00 4.00 0.04 0.00 407.42 40.64 20.94 3.16 2.27 11.29 4.57 27.33 6.06 2.87 0.80 -16.34 0.56
U104055120 1.97 104.00 55.00 ~ 1.20 2.40 0.04 0.00 250.83 43.85 7.65 4.23 1.77 8.53 1.89 27.91 4.31 1.04 0.21 -10.75 0.36
U104067180 3.26 104.00 67.00 ~ 1.80 3.60 0.04 0.00 414.97 76.41 19.55 4.30 2.18 14.95 4.12 52.56 8.42 2.48 0.61 -13.66 0.48
U104067200 3.63 104.00 67.50 ~ 2.00 4.00 0.04 0.00 461.42 85.14 22.12 4.30 2.19 16.69 4.64 60.24 9.78 2.88 0.75 -13.27 0.52
U129055120 2.21 129.00 55.00 ~ 1.20 2.40 0.04 0.00 280.83 71.71 8.16 5.11 1.72 11.22 1.95 44.63 5.48 1.05 0.20 -9.32 0.33
U129068180 3.64 129.00 68.00 ~ 1.80 3.60 0.04 0.00 463.57 125.72 21.80 5.23 2.18 19.77 4.37 88.61 11.62 2.58 0.60 -12.35 0.44
U129068200 4.04 129.00 68.00 ~ 2.00 4.00 0.04 0.00 513.42 139.36 24.17 5.22 2.17 21.95 4.85 101.01 13.41 2.96 0.74 -11.79 0.48
U154055120 2.44 154.00 55.00 ~ 1.20 2.40 0.04 0.00 310.83 108.15 8.57 5.97 1.68 14.16 1.99 65.69 6.68 1.05 0.19 -8.15 0.30
U154067180 3.97 154.00 67.00 ~ 1.80 3.60 0.04 0.00 504.97 186.46 22.07 6.10 2.10 24.50 4.35 131.52 14.41 2.54 0.57 -10.56 0.41
U154067200 4.40 154.00 67.00 ~ 2.00 4.00 0.04 0.00 559.42 206.80 24.47 6.10 2.10 27.21 4.83 154.17 17.43 2.92 0.71 -10.03 0.45
U204055120 2.91 204.00 55.00 ~ 1.20 2.40 0.04 0.00 370.83 210.39 9.19 7.63 1.59 20.75 2.05 121.50 9.15 1.06 0.18 -6.37 0.26
U204067180 4.68 204.00 67.00 ~ 1.80 3.60 0.04 0.00 594.97 359.07 23.84 7.81 2.01 35.52 4.50 243.99 19.72 2.57 0.54 -8.36 0.35
U204067200 5.18 204.00 67.00 ~ 2.00 4.00 0.04 0.00 659.42 398.55 26.43 7.80 2.01 39.46 4.99 287.27 23.93 2.96 0.67 -7.84 0.39
U254055120 3.39 254.00 55.00 ~ 1.20 2.40 0.04 0.00 430.83 357.82 9.64 9.24 1.52 28.31 2.09 196.47 11.70 1.07 0.17 -5.08 0.22
U254067180 5.38 254.00 67.00 ~ 1.80 3.60 0.04 0.00 684.97 605.25 25.15 9.46 1.93 48.00 4.59 395.69 25.19 2.59 0.51 -6.71 0.31
U254067200 5.97 254.00 67.00 ~ 2.00 4.00 0.04 0.00 759.42 672.13 27.88 9.45 1.92 53.34 5.10 466.77 30.56 2.98 0.65 -6.20 0.34
U304067200 6.76 304.00 67.00 ~ 2.00 4.00 0.04 0.00 859.42 1039.79 29.00 11.06 1.85 68.86 5.18 695.56 37.37 3.00 0.62 -4.94 0.31
8
2.6 Ancillary Products
The following products are supplied by Kingspan Steel Building Solutions and its agents. These components
are not manufactured by Kingspan Steel Building Solutions;
The following span tables show the maximum span for each stud section under different applied windloads,
effective lengths and span deflection ratios. When using the tables please take into consideration the following
notes:
The values shown in each table are the maximum spans in metres of each stud section.
The section properties used to form the tables are in accordance with BS5950: Part 5:1998. Design is
based on SCI assessed methodology (SCI Assessed Report RT1439 April 2012).
The span tables apply to SFS Infill sections only. They do not apply for oversail or load bearing sections.
Spans are not limited by the end conditions and therefore these must be checked separately. Spans in bold
and italic highlight spans to which the standard stud/track end condition must be checked.
Wind loads are assumed to be uniformly distributed loads only.
No allowance has been made for barrier loading or any other additional imposed load.
Span tables do not consider the axial capacity of the stud sections.
Allowable deflection ratios depend on the type of finishes being applied to the SFS. For further advice seek
specialist manufacturer’s guidance.
If in doubt on how to apply these tables, please seek advice from Kingspan Steel Building Solutions.
Span tables are to be used for guidance only.
Kingspan accepts no liability for the use of its published span tables on live schemes.
Schemes should be referred to Kingspan for design and engineering calculations (at agreed costs) prior to
material purchase in all instances.
9
SFS Span Tables – Studs at 600 centres
Deflection Ratio: L/360 Deflection Ratio: L/360
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
Unfactored Wind load (kN/m2) Unfactored Wind load (kN/m2)
Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2 Stud Section 0.6 0.8 1 1.2 1.4 1.6 1.8 2
C070050150 3.03 2.75 2.56 2.40 2.28 2.18 2.10 2.03 C070050150 3.03 2.75 2.56 2.40 2.28 2.18 2.10 2.03
C070070200 3.64 3.31 3.07 2.89 2.75 2.63 2.53 2.44 C070070200 3.64 3.31 3.07 2.89 2.75 2.63 2.53 2.44
C100050120 3.68 3.35 3.11 2.93 2.78 2.66 2.56 2.47 C100050120 3.69 3.35 3.11 2.93 2.78 2.66 2.56 2.47
C100060120 3.87 3.51 3.26 3.07 2.92 2.79 2.68 2.59 C100060120 3.87 3.51 3.26 3.07 2.92 2.79 2.68 2.59
C100070120 4.03 3.66 3.40 3.20 3.04 2.91 2.80 2.70 C100070120 4.03 3.66 3.40 3.20 3.04 2.91 2.80 2.70
C100070160 4.43 4.02 3.74 3.52 3.34 3.19 3.07 2.96 C100070160 4.43 4.02 3.74 3.52 3.34 3.19 3.07 2.96
C100070200 4.76 4.32 4.01 3.78 3.59 3.43 3.30 3.18 C100070200 4.76 4.32 4.01 3.78 3.59 3.43 3.30 3.18
C125050120 3.95 3.66 3.45 3.28 3.15 3.04 2.95 2.87 C125050120 4.37 3.97 3.69 3.47 3.30 3.15 3.03 2.93
C125060120 4.46 4.13 3.86 3.63 3.45 3.30 3.17 3.06 C125060120 4.58 4.16 3.86 3.63 3.45 3.30 3.17 3.06
C125070120 4.76 4.33 4.02 3.78 3.59 3.43 3.30 3.19 C125070120 4.76 4.33 4.02 3.78 3.59 3.43 3.30 3.19
C125070160 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.50 C125070160 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.50
C125070200 5.63 5.11 4.74 4.47 4.24 4.06 3.90 3.77 C125070200 5.63 5.11 4.75 4.47 4.24 4.06 3.90 3.77
C150050120 4.18 3.88 3.65 3.48 3.34 3.23 3.13 3.04 C150050120 5.03 4.57 4.25 4.00 3.80 3.63 3.49 3.37
C150060120 4.73 4.39 4.14 3.94 3.78 3.65 3.54 3.44 C150060120 5.26 4.78 4.44 4.17 3.97 3.79 3.65 3.52
C150070120 5.25 4.86 4.59 4.34 4.12 3.94 3.79 3.66 C150070120 5.47 4.97 4.61 4.34 4.12 3.94 3.79 3.66
C150070160 5.69 5.27 4.97 4.73 4.53 4.33 4.17 4.02 C150070160 6.01 5.46 5.07 4.77 4.53 4.33 4.17 4.02
C150070200 6.10 5.64 5.31 5.05 4.84 4.66 4.48 4.32 C150070200 6.46 5.87 5.45 5.13 4.87 4.66 4.48 4.32
C200050120 4.57 4.24 4.00 3.82 3.66 3.54 3.43 3.34 C200050120 5.89 5.46 5.15 4.91 4.71 4.54 4.38 4.23
C200060120 5.18 4.81 4.54 4.33 4.16 4.01 3.89 3.78 C200060120 6.57 5.97 5.54 5.22 4.96 4.74 4.56 4.40
C200070120 5.76 5.34 5.04 4.81 4.62 4.46 4.32 4.20 C200070120 6.81 6.19 5.75 5.40 5.14 4.91 4.72 4.56
C200070160 6.23 5.78 5.45 5.19 4.98 4.81 4.66 4.54 C200070160 7.49 6.81 6.32 5.95 5.65 5.40 5.20 5.02
C200070200 6.65 6.15 5.80 5.52 5.30 5.12 4.96 4.82 C200070200 8.06 7.32 6.80 6.40 6.08 5.81 5.59 5.40
C250070120 6.18 5.74 5.42 5.16 4.96 4.79 4.65 4.52 C250070120 7.98 7.37 6.84 6.43 6.11 5.85 5.62 5.43
C250070160 6.68 6.19 5.84 5.57 5.35 5.17 5.01 4.87 C250070160 8.60 7.98 7.52 7.08 6.73 6.43 6.19 5.97
C250070200 7.11 6.59 6.21 5.92 5.68 5.48 5.32 5.17 C250070200 9.13 8.46 7.98 7.60 7.24 6.92 6.66 6.43
C300070200 7.51 6.96 6.56 6.26 6.01 5.80 5.63 5.47 C300070200 9.66 8.96 8.45 8.05 7.73 7.46 7.24 7.03
When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions – please check separately.
10
SFS Span Tables – Studs at 400 centres
Deflection Ratio: L/360 Deflection Ratio: L/360
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
C070050150 3.47 3.15 2.92 2.75 2.61 2.50 2.40 2.32 C070050150 3.47 3.15 2.92 2.75 2.61 2.50 2.40 2.32
C070070200 4.17 3.79 3.52 3.31 3.14 3.01 2.89 2.79 C070070200 4.17 3.79 3.52 3.31 3.14 3.01 2.89 2.79
C100050120 4.10 3.80 3.56 3.35 3.18 3.04 2.93 2.83 C100050120 4.22 3.83 3.56 3.35 3.18 3.04 2.93 2.83
C100060120 4.43 4.02 3.73 3.51 3.34 3.19 3.07 2.96 C100060120 4.43 4.02 3.73 3.51 3.34 3.19 3.07 2.96
C100070120 4.61 4.19 3.89 3.66 3.48 3.33 3.20 3.09 C100070120 4.61 4.19 3.89 3.66 3.48 3.33 3.20 3.09
C100070160 5.07 4.61 4.28 4.02 3.82 3.66 3.51 3.39 C100070160 5.07 4.61 4.28 4.02 3.82 3.66 3.51 3.39
C100070200 5.44 4.95 4.59 4.32 4.10 3.93 3.77 3.64 C100070200 5.44 4.95 4.59 4.32 4.10 3.93 3.77 3.64
C125050120 4.40 4.07 3.84 3.66 3.51 3.39 3.28 3.19 C125050120 5.00 4.55 4.22 3.97 3.77 3.61 3.47 3.35
C125060120 4.97 4.60 4.34 4.13 3.95 3.78 3.63 3.51 C125060120 5.24 4.76 4.42 4.16 3.95 3.78 3.63 3.51
C125070120 5.45 4.95 4.60 4.33 4.11 3.93 3.78 3.65 C125070120 5.45 4.95 4.60 4.33 4.11 3.93 3.78 3.65
C125070160 5.99 5.44 5.05 4.76 4.52 4.32 4.16 4.01 C125070160 5.99 5.44 5.05 4.76 4.52 4.32 4.16 4.01
C125070200 6.44 5.85 5.43 5.11 4.85 4.64 4.46 4.31 C125070200 6.44 5.85 5.43 5.11 4.85 4.64 4.46 4.31
C150050120 4.65 4.31 4.07 3.88 3.72 3.59 3.48 3.39 C150050120 5.76 5.23 4.86 4.57 4.34 4.15 3.99 3.86
C150060120 5.26 4.88 4.60 4.39 4.21 4.07 3.94 3.83 C150060120 6.02 5.47 5.08 4.78 4.54 4.34 4.17 4.03
C150070120 5.83 5.41 5.10 4.86 4.67 4.51 4.34 4.19 C150070120 6.25 5.68 5.28 4.96 4.72 4.51 4.34 4.19
C150070160 6.35 5.88 5.54 5.27 5.06 4.88 4.73 4.60 C150070160 6.88 6.25 5.80 5.46 5.19 4.96 4.77 4.61
C150070200 6.81 6.30 5.92 5.64 5.41 5.21 5.05 4.91 C150070200 7.39 6.72 6.24 5.87 5.58 5.33 5.13 4.95
C200050120 5.08 4.71 4.45 4.24 4.07 3.94 3.82 3.71 C200050120 6.55 6.08 5.73 5.46 5.24 5.06 4.91 4.77
C200060120 5.76 5.34 5.04 4.81 4.62 4.46 4.33 4.21 C200060120 7.43 6.83 6.34 5.97 5.67 5.42 5.22 5.04
C200070120 6.40 5.94 5.60 5.34 5.13 4.96 4.81 4.67 C200070120 7.80 7.08 6.58 6.19 5.88 5.62 5.40 5.22
C200070160 6.93 6.43 6.06 5.78 5.55 5.35 5.19 5.05 C200070160 8.58 7.79 7.23 6.81 6.47 6.19 5.95 5.74
C200070200 7.41 6.86 6.46 6.15 5.91 5.70 5.52 5.37 C200070200 9.23 8.38 7.78 7.32 6.96 6.65 6.40 6.18
C250070120 6.86 6.37 6.02 5.74 5.51 5.32 5.16 5.02 C250070120 8.87 8.23 7.76 7.37 6.99 6.69 6.43 6.21
C250070160 7.43 6.89 6.50 6.19 5.95 5.75 5.57 5.42 C250070160 9.57 8.87 8.37 7.98 7.66 7.36 7.08 6.84
C250070200 7.92 7.33 6.91 6.59 6.32 6.10 5.92 5.76 C250070200 10.16 9.42 8.88 8.46 8.12 7.84 7.60 7.36
C300070200 8.35 7.74 7.30 6.96 6.68 6.45 6.26 6.09 C300070200 10.74 9.96 9.40 8.96 8.60 8.31 8.05 7.83
When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions – please check separately.
11
SFS Span Tables – Studs at 300 centres
Deflection Ratio: L/360 Deflection Ratio: L/360
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions – please check separately.
12
SFS Span Tables – Studs at 600 centres
Deflection Ratio: L/240 Deflection Ratio: L/240
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions – please check separately.
13
SFS Span Tables – Studs at 400 centres
Deflection Ratio: L/240 Deflection Ratio: L/240
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
C070050150 3.97 3.61 3.35 3.15 2.99 2.86 2.75 2.66 C070050150 3.97 3.61 3.35 3.15 2.99 2.86 2.75 2.66
C070070200 4.77 4.34 4.03 3.79 3.60 3.44 3.31 3.20 C070070200 4.77 4.34 4.03 3.79 3.60 3.44 3.31 3.20
C100050120 4.10 3.80 3.58 3.41 3.27 3.15 3.05 2.97 C100050120 4.83 4.39 4.08 3.83 3.64 3.48 3.35 3.23
C100060120 4.63 4.28 4.04 3.84 3.69 3.56 3.45 3.35 C100060120 5.07 4.60 4.27 4.02 3.82 3.65 3.51 3.39
C100070120 5.12 4.74 4.45 4.19 3.98 3.81 3.66 3.54 C100070120 5.28 4.80 4.45 4.19 3.98 3.81 3.66 3.54
C100070160 5.61 5.18 4.88 4.61 4.37 4.18 4.02 3.88 C100070160 5.80 5.27 4.89 4.61 4.37 4.18 4.02 3.88
C100070200 6.08 5.60 5.26 4.95 4.70 4.49 4.32 4.17 C100070200 6.23 5.66 5.26 4.95 4.70 4.49 4.32 4.17
C125050120 4.40 4.07 3.84 3.66 3.51 3.39 3.28 3.19 C125050120 5.64 5.20 4.83 4.55 4.32 4.13 3.97 3.83
C125060120 4.97 4.60 4.34 4.13 3.97 3.83 3.71 3.61 C125060120 6.00 5.45 5.06 4.76 4.52 4.32 4.16 4.01
C125070120 5.50 5.10 4.81 4.58 4.40 4.24 4.11 4.00 C125070120 6.24 5.67 5.26 4.95 4.70 4.50 4.33 4.18
C125070160 6.00 5.55 5.23 4.98 4.77 4.61 4.46 4.34 C125070160 6.86 6.23 5.79 5.44 5.17 4.95 4.76 4.59
C125070200 6.47 5.97 5.61 5.34 5.11 4.93 4.77 4.64 C125070200 7.37 6.70 6.22 5.85 5.56 5.32 5.11 4.93
C150050120 4.65 4.31 4.07 3.88 3.72 3.59 3.48 3.39 C150050120 5.98 5.54 5.22 4.98 4.77 4.61 4.46 4.33
C150060120 5.26 4.88 4.60 4.39 4.21 4.07 3.94 3.83 C150060120 6.77 6.26 5.81 5.47 5.20 4.97 4.78 4.61
C150070120 5.83 5.41 5.10 4.86 4.67 4.51 4.37 4.25 C150070120 7.16 6.51 6.04 5.68 5.40 5.16 4.96 4.79
C150070160 6.35 5.88 5.54 5.27 5.06 4.88 4.73 4.60 C150070160 7.87 7.15 6.64 6.25 5.94 5.68 5.46 5.27
C150070200 6.81 6.30 5.92 5.64 5.41 5.21 5.05 4.91 C150070200 8.46 7.69 7.14 6.72 6.38 6.10 5.87 5.67
C200050120 5.08 4.71 4.45 4.24 4.07 3.94 3.82 3.71 C200050120 6.55 6.08 5.73 5.46 5.24 5.06 4.91 4.77
C200060120 5.76 5.34 5.04 4.81 4.62 4.46 4.33 4.21 C200060120 7.43 6.89 6.50 6.19 5.94 5.73 5.56 5.40
C200070120 6.40 5.94 5.60 5.34 5.13 4.96 4.81 4.67 C200070120 8.25 7.65 7.21 6.87 6.60 6.36 6.16 5.97
C200070160 6.93 6.43 6.06 5.78 5.55 5.35 5.19 5.05 C200070160 8.91 8.26 7.79 7.42 7.12 6.87 6.66 6.47
C200070200 7.41 6.86 6.46 6.15 5.91 5.70 5.52 5.37 C200070200 9.48 8.78 8.28 7.88 7.57 7.30 7.07 6.87
C250070120 6.86 6.37 6.02 5.74 5.51 5.32 5.16 5.02 C250070120 8.87 8.23 7.76 7.40 7.10 6.86 6.64 6.46
C250070160 7.43 6.89 6.50 6.19 5.95 5.75 5.57 5.42 C250070160 9.57 8.87 8.37 7.98 7.66 7.39 7.17 6.97
C250070200 7.92 7.33 6.91 6.59 6.32 6.10 5.92 5.76 C250070200 10.16 9.42 8.88 8.46 8.12 7.84 7.60 7.39
C300070200 8.35 7.74 7.30 6.96 6.68 6.45 6.26 6.09 C300070200 10.74 9.96 9.40 8.96 8.60 8.31 8.05 7.83
When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions – please check separately.
14
SFS Span Tables – Studs at 300 centres
Deflection Ratio: L/240 Deflection Ratio: L/240
Effective Length: 0.85 x L Effective Length: 0.5 x L (Mid-Span Noggins)
When using these tables, please refer to notes in Section 2.7. Note: Spans highlighted in Bold and Italic may require non-standard stud/track end conditions – please check separately.
15
3 SFS STANDARD FIXINGS
3.1 Recommended Fixings
Kingspan Steel Building Solutions do not sell fixings associated with SFS. Set out below are standard SFS fixings from a variety of manufacturers. All
fixings stated are general recommendations only. All connections from the SFS to any interfacing structure or material must be checked for suitability and
design with Kingspan Steel Building Solutions and the third party supplier prior to construction. Installers may also wish to use other fixings – this should be
communicated to Kingspan at the start of the project (prior to design commencing) such that they can be checked for suitability and incorporated into the
design.
Note: Kingspan do not recommend the use of PH3 fixings for flush cold rolled to cold rolled connections
16
Application Supplier Product Code Description Tools Picture
Pancake head
CFL32 Ø5.5 x 32mm Low Profile SDS Gun
ITW-SPIT
(Eurocode 921260) TEK, Self Drilling, Fine Phillips No.2
threaded, Self tapping
17
Application Supplier Product Code Description Tools Picture
SDS Gun
Hex head anchor 8mm Hex
4H32
ITW-SPIT Ø6 x 32mm SDS Drill
(Eurocode 921502)
6mm masonry
bit
Impact Driver
HUS 6x45 Hex head anchor
Hilti Torx 40
2065502 Ø6 x 45mm
SDS Drill 6mm
SFS to Concrete
Connections SDS Gun
3.0mm steel to concrete 8mm Hex
Hex head anchor
Ejot 4H 6.3x32 SDS Drill
Ø6.3 x 32mm
CDR 4L (Ejot
ref)
SDS Gun
5/16" Hexagonal
Hex head anchor
Evolution MSHH6.3-32-516 SDS Drill
Ø6.3 x 32mm
5mm masonry
bit
Through bolt
SDS Gun
ITW-SPIT TRIGA Z V6 10/20 Torque controlled expanding
SDS Drill
anchor
Stud anchor
SDS Gun
ITW-SPIT TRIGA Z E6 10/20 Torque controlled expanding
SDS Drill
anchor
Bracket to Concrete
Steel brackets to Concrete
Tapcon LDT M10x60 SDS Gun
ITW-SPIT Large diameter screw anchor
(Typical) SDS Drill
18
Application Supplier Product Code Description Tools Picture
S-WD 13C 4.8 x 38
4.8 x 38mm wafer head wing SDS Gun
Hilti S-WD 13C 5.5 x 65
Sheathing Board / Timber to tip screw Phillips No.2
283636, 283638
SFS
(Max. 47mm board to max.
steel thickness 3.0mm) WDLS 4.8 x 38 4.8 x 38mm wafer head wing SDS Gun
Ejot
WDLS 5.5 x 50 to 127 tip screw Phillips No.2
Rigid phenolic insulation JT3-6-5.5 x L S16 with Varying insulation thickness SDS Gun
Ejot
board to SFS SBV 90 washer up to 100mm to 4.0mm steel 8mm Hex
19
4 INFILL SFS
20
Type 3 – Head Track Blocking (Detail A16)
An installer may choose a third method of creating an allowance for deflection, by placing blocking sections
of stud within the top track, tightly fitting between every stud. This will prevent the studs from racking or
twisting and allow the track to move freely over the studs.
Type 4 – Slotted Stud (Detail A21)
The Slotted Stud system works using a centrally positioned pre-punched slot in the flange of the ‘C’ profile.
The stud is secured using fixings installed through both flanges of the head track through the slots in the
stud. This allows for relative deflection of the head track whilst still providing restraint for the studs.
When using the slotted stud, the installer should be aware of the following:
When placing orders for slotted studs, the order must clearly state that slotted studs are required. This is the
responsibility of the installer.
Kingspan have a minimum rolling length of 600mm for each section. Therefore, cripple studs beneath this
length do not require slots and can be fixed to the lintel only as shown in Figure 3 below:
21
4.1.8 Service Holes
Holes may be required in SFS members to allow cabling or pipework to pass within the wall zone. SCI
Publication 301 – Light Steel Framing in Residential Construction (Section 9) gives an approximate guide to the
maximum sizes and spacing of service penetrations in light gauge steel sections without compromising the
structural integrity. The following rules should be followed when drilling holes within SFS sections.
A Depth of member - - -
No holes outside of these rules should be created in SFS members without the prior agreement of Kingspan
Steel Building Solutions technical team.
22
4.1.10 Braced Bays
Where structural bracing fouls the zone of the SFS, alternative detailing must be provided. There are several
ways to accomplish this, each of which requires coordination with the design engineer and fabricator:
Use of SHS or RHS bracing instead of flats allows SFS to be fitted above and below.
Flat strap bracing can be detailed offset to the external or internal face, allowing SFS to span unimpeded in
the remaining zone. This must be confirmed with the engineer/fabricator as it will result in eccentric loads
applied to the columns.
If neither of the above are possible, twin 70mm systems may be able to span either side of the bracing and
be tied together at regular vertical centres if required by design.
Figure 5 - SHS Bracing Figure 6 - Off-set bracing Figure 7 - Twin system around bracing
23
4.1.14 Kingposts
The KingPOST is a wind moment post designed and supplied by Kingspan Steel Building Solutions.
The KingPOST is an alternative for bespoke hot rolled steel posts and is used to provide restraint to the SFS
system on applications such as large spanning windows or parapets. It offers a standard off the shelf solution
that can be used to form a range of cantilevers. The base is a standard assembly to which light gauge steel
studs can be fixed to form the final arrangement.
Further details on Kingposts can be found on Kingspan Technical Application Document: Kingpost Installation
(TAD 00057) and standard details C.18a and C.19a
Kingspan Steel Building Solutions have developed a range of standard oversail cleats as an alternative for
bespoke lateral or dead load cleats. The cleats can be used to fix the SFS studs back to the primary structure at
intermediate positions to provide lateral and dead restraint. It offers a standard off the shelf solution that can be
ordered in a range of depths and leg lengths to suit.
The SFS Oversail cleats will be designed and supplied by Kingspan Steel Building Solutions.
The SFS oversail cleats are suitable for general studs and jamb studs, but bespoke cleats may be required for
non-standard applications.
Cleat Ref; KWC9524 Cleat Ref; KWC14028 Cleat Ref; KWC14040 Cleat Ref;
Further details on Kingspan Oversail Cleats can be found on Kingspan Technical Application Document:
Kingpost Installation (TAD 00058) and standard details.
24
5 OVERSAIL SFS
25
5.1.3 Splicing of Sections
Studs should be spliced into manageable lengths to facilitate safe site installation and to guarantee adequate
structural performance. These splices are individually designed to ensure that they are strong enough for
each application but will generally be just above restraint points. No splices should be added where not
indicated by the design. If additional cuts are required in order to safely install the system, please contact
Kingspan Steel Building Solutions prior to ordering the steel.
Where openings do not align floor on floor, it may be impractical to use traditional oversail SFS. In these
instances, single storey ‘overfills’ may be formed outside the line of the building using bespoke bracketry as
shown in detail 0.
5.1.13 Fixings
The correct and adequate fixing of brackets to the primary structure must be specified by Kingspan Steel
Building Solutions engineers. Generally, bracket fixing to concrete take the form of either mechanical or resin
anchors and fixings to hot rolled steel will be grade 8.8 structural bolts.
26
6 STANDARD DETAILS
6.1 ‘A’ Series – Basic Connections
Rev.
A.01 Head Track to Concrete Connection – Straight SD04
A.02 Head Track to Steel Connection – Straight SD03
A.03 U Base Track to Concrete Connection – Straight SD03
A.04 U Base Track to Steel Connection – Straight SD03
A.05s Head Track to Concrete Connection – Curved Option 1 (Slotted Stud) SD05
A.06s Head Track to Concrete Using Slotted Stud Connection – Curved – Option 2 SD04
A.07s Head Track to Steel Using Slotted Stud Connection – Curved Option 1 SD04
A.08s Head Track to Steel Using Slotted Stud Connection – Curved Option 2 SD04
A.09 Base Track to Concrete Connection – Curved Option 1 SD03
A.10 Base Track to Concrete Connection – Curved Option 2 SD03
A.11 Base Track to Steel Connection – Curved Option 1 SD03
A.12 Base Track to Steel Connection – Curved Option 2 SD03
A.13 Stud to Base Track Connection SD03
A.14 Stud to Head Track Using DHB – Type 1 Head Clip SD03
A.15 Stud to Head Track – Type 2 Block & Brace SD03
A.16 Stud to Head Track – Type 3 Head Track Blocking Connection SD03
A.17 Stud – ‘Back-to-Back’ Construction SD03
A.18 Stud to Concrete Column SD03
A.19 Stud to Steel Column Connection SD03
A.20 Tracks Joint Fixing SD05
A.21 Slotted Stud to Head Track – Type 4 Slotted Stud SD03
A.22 Flat Strap Bracing Detail Connection SD05
A.23 Vertical Stud to Steel Column Connection with welded plates SD03
A.24 Vertical Stud to Steel Column Connection SD03
A.25 Head Track Fixings at PFC Parapets SD01
27
ref note
A
STANDARD DETAIL
B Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
A
STANDARD DETAIL
Steel Building
B Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
A Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
B Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
A
title: INFILL FRAMING
HEAD TRACK CONC. USING SLOTTED
STUD CONNECTION - STRAIGHT - OPTION 2
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.06S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
B
title: INFILL FRAMING
HEAD TRACK TO STEEL USING SLOTTED
STUD CONNECTION - CURVED OPTION 1
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.07S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
A.03 BASE TRACK TO CONCRETE CONNECTION - STRAIGHT MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
A.04 BASE TRACK TO STEEL CONNECTION - STRAIGHT MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
A.05s HEAD TRACK TO CONCRETE CONNECTION - CURVED MINIMUM 32 BEARING ON STRUCTURE AT ALL TIMES
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
NOTE - THIS IS NOT REQUIRED AT ALL Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
COLUMN LOCATIONS. PLEASE REFER TO
KINGSPAN ELEVATION DRAWINGS AND title: INFILL FRAMING
DETAILS FOR LOCATIONS. VERTICAL STUD TO CONC. COLUMN
CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.18 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
NOTE - THIS IS NOT REQUIRED AT ALL COLUMN Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
LOCATIONS. PLEASE REFER TO KINGSPAN
ELEVATION DRAWINGS AND DETAILS FOR title: INFILL FRAMING
LOCATIONS.
VERTICAL STUD TO STEEL COLUMN
CONNECTION
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.19 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
NOTE - THIS IS NOT REQUIRED AT ALL COLUMN Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
LOCATIONS. PLEASE REFER TO KINGSPAN
ELEVATION DRAWINGS AND DETAILS FOR title: INFILL FRAMING
LOCATIONS.
VERTICAL STUD TO STEEL CLOUMN
CONNECTION - WELDED PLATES
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.23 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
A.18 VERTICAL STUD TO CONCRETE COLUMN ref note
SECTION A-A
SD03 REVIEW/UPDATE 01.05.12 KPS
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
A.24 VERTICAL
NOTE - THIS ISSTUD TO STEEL
NOT REQUIRED AT ALL COLUMN WITH PACKING STUDS Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
COLUMN LOCATIONS. PLEASE REFER TO
KINGSPAN ELEVATION DRAWINGS AND title: INFILL FRAMING
DETAILS FOR LOCATIONS. VERTICAL STUD TO STEEL COLUMNS
CONNECTION - PACKING STUDS
date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref A.24 rev SD03
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
A.25a
A HEAD TRACK FIXED TO SFS TRACK/ANGLES
USING FIXINGS AS SPECIFIED ON KPS
DRAWINGS
B ANGLE TO BE SPECIFIED PROJECT BY
PROJECT.
IMPORTANT - FIXING EDGE DISTANCES MUST BE
FIXINGS REQUIRED AT 300mm crs. OBSERVED AT ALL TIMES - REFER TO SPECIFIC
DRAWING NOTES AND FIXING DATASHEETS
A.25b
A B
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
53
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
N.B. TRACKS MUST NOT BE CUT AT JAMB
STUD LOCATIONS. title: SCAFFOLD PENETRATION THROUGH
HEAD TRACK - ON STUD
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
N.B. TRACKS MUST NOT BE CUT AT JAMB
STUD LOCATIONS. title: SCAFFOLDING PENETRATION THROUGH
HEAD TRACK - BETWEEN STUDS
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
64
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
NOTES: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED date 16.12.09 drg by KPS
SLOTTED STUDS ARE NOT TO BE USED TO UNDERSIDE OF CILL. scale NTS sheet A4
detail ref C.01 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
NOTES: ALL CILL SECTIONS ARE TO BE FULL LENGTH AND MUST NOT BE SPLICED date 16.12.09 drg by KPS
SLOTTED STUDS ARE NOT TO BE USED TO UNDERSIDE OF CILL. scale NTS sheet A4
detail ref C.02 rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
15mm
MIN
20mm SD04 REVIEW/UPDATE 23.10.12 KPS
MIN SD03 REVIEW/UPDATE 01.05.12 KPS
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
B
title: LINTEL CONSTRUCTION - SLOTTED SINGLE
STUD OVER 600mm ON DOUBLE TRACK
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
C
Steel Building
C.07s LINTEL CONSTRUCTION - QUADRUPLE TRACK & SINGLE STUD Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
JAMB STUD
(DETAIL
HANDED AT
OPPOSITE
JAMB)
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
MB CONSTRUCTION - SINGLE STUD & SINGLE TRACK date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref C.10S rev SD04
KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
CLEAT TYPE:
B13510560 Steel Building
(AS REQUIRED BY DESIGN)
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
C.13 HIGH LOAD CONNECTION - HEAVY DUTY CLEAT - HEAD C.14 HIGH LOAD CONNECTION - HEAV
ref note
B15310560 USE:
CLEAT TYPE
KHC9524A
CLEAT TYPE:
STANDARD DETAIL
B13510560
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
CLEAT TYPE:
KHC9528B date 16.12.09 drg by KPS
scale NTS sheet A4
detail ref C.14 rev SD05
C.14 HIGH LOAD CONNECTION - HEAVY DUTY CLEAT - BASE C.15 HIGH LOAD CONNECTION - HEAVY KINGSPAN STEEL BUILDING SOLUTIONS
ref note
STANDARD DETAIL
Steel Building
Solutions
R
CLEAT TYPE CLEAT TYPE: Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
KHC9524A B13510560
title: HIGH LOAD CLEAT AT HEAD WITH
ZED BAR CONNECTION
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
FIXING
R65
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
R65
FIXING
LOCATIONS STEEL Solutions
FIXING
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
90
email: enquiries@kingspan.com
LOCATIONS
title: KINGPOST - CILL CONNECTION
87
ref note
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
101
ref note
300
BOARDING JOINT INDICATED IN THIS DRAWING.
600
VERTICAL STUDS ARE PROVIDED IN MODULES OF 200,
300, 400 OR 600mm TO SUIT 2400x1200mm BOARDS.
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
25mm
MAX LIVE LOAD DEFLECTION
10mm
BOARD TO FIXING EDGE DISTANCE
67mm
SD02 STANDARD DETAIL 01.04.11 KPS
STANDARD DETAIL
Steel Building
40mm MIN.
FROM TRACK LEG TO FIXING Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
65mm Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
BOARD TO FIXING EDGE DISTANCE
TO AVOID HEAD TRACK LEG
title: EXTERNAL BOARDING ACROSS
SLAB EDGE
104
ref note
150
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
106
ref note
= = SP01
ref
SPECIFICATION
revision
16.12.09
date
KPS
by
STANDARD DETAIL
DIM 'A'
Steel Building
Solutions
DRYLINING WALL CONSTRUCTION BY OTHERS PENETRATES EXTERNAL
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
R
email: enquiries@kingspan.com
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
*
*
*
AS PER PROJECT
REQUIREMENTS 225mm max.
SFS ZONE
BUILD UP OF EXTERNAL LEAF
BY OTHERS
STANDARD DETAIL
Steel Building
Solutions
R
Manor Works, Pleck Road, Walsall, WS2 9ES
Tel: 01944 712000 Design: 0121 7765460
email: enquiries@kingspan.com
Cavity Systems
Where a drainage/ventilation cavity is required,
the cavity is usually placed between the sheathing
board and the insulation by use of vertical top hat
spacers. Further guidance should be sought from
All masonry must be dead loaded to a suitable the render system manufacturer.
support (slab edge angle or ground slab) as
the SFS is designed to withstand horizontal
loads only in this case.
115
7.6 Metal Rainscreen
7.4 Terracotta Rainscreen
Lightweight metal rainscreen systems may be
Terracotta tile systems may be supported from an supported from an SFS system. There are
SFS system. The dead weight and loadings of the typically two main types of support to a tile based
chosen system must be communicated to system; horizontal support and vertical systems.
Kingspan Steel Building Solutions engineers to
check the adequacy of a given stud arrangement. Horizontal Systems
There are typically two main types of support to a Where the interfacing rails for the rainscreen are
tile based system; horizontal and vertical systems. fixed horizontally to the SFS, the load is evenly
distributed across the frame. This requires no
Horizontal Systems special constructions within the SFS.
Where the interfacing rails for the terracotta are
fixed horizontally to the SFS, the load is evenly Vertical Systems
distributed across the frame. This requires no Where the cladding rails span vertically, there is
special constructions within the SFS. may either be a sub-system of horizontally
spanning rails to distribute the loads in the SFS or
Vertical Systems the brackets may be directly fixed back to the
Where the cladding rails span vertically, there is SFS. In the latter case, there may be specific
may either be a sub-system of horizontally setting out requirements for the SFS in order to
spanning rails to distribute the loads in the SFS or guarantee studs in the desired locations. These
the brackets may be directly fixed back to the need to be specifically identified to Kingspan Steel
SFS. In the latter case, there may be specific Building Solutions prior to design.
setting out requirements for the SFS in order to
guarantee studs in the desired locations. These
need to be specifically identified to Kingspan Steel
Building Solutions prior to design.
116
8 COSHH & TECHNICAL DATASHEETS
8.1 General Specification Notes
PRODUCTS: Steel Framing System ‘U’ Track and ‘C’ Stud cold formed steel galvanised profiles
SUPPLIER:
Kingspan Steel Building Solutions, Pleck Road, Walsall, WS2 9ES
Tel; +44 (0) 1944 712 000
www.kingspanprofiles.com
Products
Cold rolled components are manufactured from Service slots can be provided in studs when
pre-hot dipped galvanised steel, Z275 coating, requested and if deemed acceptable by Kingspan
guaranteed yield strength 390 N/mm². All studs, Steel Building Solutions Design Department.
joists, tracks and accessories shall be of a type, Track members shall be securely anchored to the
size, gauge and spacing determined by structural supporting structure as shown on the drawings.
calculation and as shown on the drawings, and Complete, uniform and level bearing support shall
shall be supplied by Kingspan Steel Building be provided to upper and lower tracks. Abutting
Solutions. Unless stated otherwise in the lengths of track shall be securely anchored to a
calculations, all structural members are designed common structural element and spliced, all as
in accordance with UK codes of practice. determined by structural calculations. Studs shall
be plumbed, aligned and securely
Procurement attached/located within upper and lower tracks.
It is the installer’s responsibility to produce a Framing of wall openings shall include headers,
cutting list and order Kingspan Steel Building lintels and supporting studs as shown on the
Solutions materials. This should be co-ordinated drawings. Temporary bracing shall be provided
to suit the desired construction programme. where required until completion of erection. The
erection contractor is responsible for the
Drawing Approval temporary stability of the structure during
All drawings must be approved by the main construction.
contract Engineer and project Architect prior to
construction works. External Walls
Insulation should be provided over the external
Erection of Components face of the stud walling that is sufficiently robust to
All systems are constructed on-site and must be remain in place during and post construction, and
installed to British Standard BS5950, BS8000 and should have adequate thermal resistance to
NSSS (National Structural Steelwork prevent cold bridging and interstitial condensation.
Specification). Liability for the quality and Insulation should be fixed in accordance with
accuracy of the installation rests with the manufacturer’s instructions. Consideration should
Contractor and not Kingspan Steel Building be given to joints in insulation boards and the
Solutions. Care must be taken when site cutting repair of damage to prevent ingress e.g. taping of
components square where they are to be used in joints or provision of a breather membrane.
right angled connections and all cut edges should Internal linings should be fixed in accordance with
be protected. Fixing of components shall be with the manufacturer’s instructions and selected to
self-tapping screws or otherwise by design. Screw achieve the specified performance for fire,
type and size shall be as typical details or to a thermal, and acoustic requirements. Where
project specific design. All screw fixings must be masonry cladding forms the external envelope, it
installed perpendicular to the surface wherever should be tied back to the Kingspan Steel Building
possible. All bolt fixings are to be Grade 8.8. No Solutions studs using stainless steel wall ties and
holes are to be cut or formed in Kingspan Steel continuous channels fixed with standoff screws.
Building Solutions SFS without prior reference to Additional studs are to be fitted at all jambs to
Kingspan Steel Building Solutions. provide support for wall ties.
117
8.2 COSHH Datasheet
PRODUCTS:
Steel Framing System ‘U’ Track and ‘C’ Stud cold formed steel galvanised profiles
SUPPLIER:
Kingspan Steel Building Solutions, Pleck Road, Walsall, WS2 9ES
Tel; +44 (0) 1944 712 000
http://www.kingspanprofiles.com
118
HEALTH HAZARD – SKIN CONTACT: protect hands and exposed skin with a barrier cream or
Lacerations of the skin can occur from sharp corners and suitable gloves.
edges or when breaking open strapping. Foot injuries could First Aid:
also be sustained when walking over discarded steel debris on In the event of skin irritation or injury, immediate medical
site (e.g. re-cut edges of sections). Steel shavings and sparks attention must be sought by an appropriately qualified person.
are produced when using tools (particularly power tools).
Precautions: HEALTH HAZARD - INHALATION:
1. Hand and Power tools – should be used only by those Steel sections at atmospheric temperatures do not emit any
wearing suitable protection. fumes or gasses.
2. Lifting – recommended techniques must be adhered to
and manual lifting should be limited to acceptable PRECAUTIONS:
weights. Never lift any packs that are not within the (As stated above).
method limits. Health Hazard – Ingestion:
3. Loading and Unpacking – suitable gloves and protective (not applicable)
clothing should be worn. Health Hazard – Exposure limits:
4. General Handling – persons with skin problems, grazes (not applicable)
and those known to be sensitive to mineral oils should Health Hazard – Fire and Explosion hazards:
(not applicable)
FURTHER INFORMATION:
Please contact the Kingspan Steel Building Solutions Technical Team on +44 (0)1944 712000.
This information is provided in good faith on the assumption that the person carrying out the task of using the product is
experienced and/or has been fully trained in the handling and use of the particular product and application.
The reader must be satisfied that they (or the person carrying out the application) are suitably responsible and that these
recommendations have been thoroughly read and understood by that person.
Kingspan Steel Building Solutions does not accept responsibility for any claims of consequential loss or injury to the user or
third party if the recommendations of this safety sheet are not adhered to.
119
9 SUPPORT SERVICES
Kingspan Steel Building Solutions offers a range of design and supply services operating from a number of
sites in the UK. To serve our customers with the maximum efficiency, we would be grateful if you could direct
your question to the following contacts:
120
Kingspan Steel Building Solutions
2 & 3 Progress Works Heath Mill Lane (Access via Bromley Street) Birmingham B9 4AL
T: +44(0)121 753 7050 F: +44(0)121 753 5187 www.kingspanpanels.co.uk/sbs
Care has been taken to ensure that the contents of this publication are accurate, but Kingspan Limited and its subsidiary
companies do not accept responsibility for errors or for information that is found to be misleading. Suggestions for, or
description of, the end use or application of products or methods of working are for information only and Kingspan Limited
and its subsidiaries accept no liability in respect thereof.