You are on page 1of 8
ICs EEEALanorarories ‘Test Report TS813-01-1 Issue | ANSUISEA 287. 1-20 10 TF12 Spectacles 11 Cetaber 2010 en “Approved by’ Prepared by: Lezed Z ‘athe Watery Keith E Whitten Cathy Woloszyn: Laboratery Manager Laboratory Assistant 8) Reports are Issueel pursward tothe ICS standard Terms and Conditions agreement 14) The enatonte of tis test report are confukemual. Reproduction of the report ix prahibitet except in fall, unless approved in writing by ICS laboratories, Inc. +) Uniless otherwive indicated, the test results contained in this report apply only to the samples testedand not 10 Jon or baches srom which they were taken ICS Laboruories, Inc #1072 Industrial Packway North # Brunswick, Ohio 4212 USA. Phone: 30.220,0518 Fas: 330,220.0816 ABS 11a Ot nw-08) 1° aan LABORATORIES dee IPO Dae: 11 Oviober 2010 Repo 15813-0141 rae Lal Objectives Contract testing to ANSHISE,A 287 1-2010 “American National Standard for Occupational and Educational Personal Bye and Face Protection Device: Clause(s): $. General Requirements 6. Impact Protector Requirements 7. Optical Radiation Protector Requirements Clear ‘Samples: ‘TFL2Speotacles Lens Color Frame Color Quanity Sumpk Clear € 20 3A Date submitted: 27 September 201 0 Procedures: Testing protocols inaccord with good laboratory practice were emplayed for all ests Al tests were conducted in a standard laboratory atmosphere unless otherwise specified. Samples were randomly selected froma the quantity provided and tested in the as-received condition unless otherwise statod ‘Testing proveshures as specified within Soction 9 of ANSUISEA 287-2010 were followed unless noted in resus. ‘When applicable, samples were assessed on medium headform (64mm PD) Assessment Summary: Dates ested: 0 through 06 October 2010 Samples as assessed meet the requirements of ANSI/ISEA 287 1-2010 for impact rated spectacles Daw: 11 October 2010 Repom: 15413-0141 Iasi! 1 Page: 2of'6 Assessment Summury-Continued: ANSTISEA 2971-2010 Requiem Compliant | No Complian 3 General Requirements 5.1 Optical Requirem S11 Opical = I S12 Lumines Transmssion Semis S13 Ham x S14) Refractive Power, Astigmatism, Resolving Power, Pris x ‘and Prism Imbulange for Hano Prowetors TT Retiaetive Power, Astigmatism, Prism and Prism Imbalance for Prescription Prowctors plicable 3 Piysical Requirements x 52.1 Diop Ball Impact Resisance x 22 Protecor Acceptance Cnieria 523 Ignition x I 52.4 Conosien Resiaance of Maal Components Ratagplicabe 52.5 Minimum Coverage Area mum Lens Thickness Not applicable king Re Nok assessed ‘Other Requirements Not applicab i Replaceable Lenses Not applisable 7 Aflennarket Components Not applicable: Trnpael Proketor Requirements 6.1 General 13 Lateral ide) COVERS G2 Impact Reg 62.1 Protector Acceptance Crier 62.2 High Mass Impact G23 High Velocity Impact 62.4 Penetration Test (Lens Only) | vel G25 Preseription Lens Matenal Qualification Rot applicable 62.6 Prescription Lens Mounting Qualification Rot applicable E_Aditional Impact Requirements for Speciiic Protector Types Not appligab ie ‘Opiical Radiation Prowctor Requirements TA Transmittanoe of Lenses TL Optional Transmittance Amributes Notapplicabe TL Clearansd Filia Lenses TLS Aulomatie Darkening Welding Fiker Lenses Rotapplicable TAA Wisible Light Filters ot ela TLS Wariation in Luminous Transinitiance See 712 72 Transmittange of Housings Nt applicable Droplet and Splash, Dust. and Fine Dust Prowctor Rex plicable LABORATORIES Dawe Report Issue Passe 11 Octobe SRIOL It 3 0f6 2010 Results: S11 Optieal Quality: Result: Pass Lenses are five of striaz, bubbles, waves and other visible defects which would impair their optical quality S13 Haze (Char Lens Onl) Sample ID) Tate Rig Fass_[ Taal 3A2 020) 17 x Regus ment Zs TThuminaie C used instead oF Mamas A SLA Refractive Power, Astigmatism, Resolving Power, Prism and Prism Imbalance for Plano Protectors Refractive Power & Astigmatism Lala Eni - Sanple 1D [“Retrastive Power | Astigmatism | Refractive Power | —Astigmatim | Ps | Fail Tal 00 [001 O02 Go} [002 oT x Requirement 7006 = 0.06 706 5006 Note: Tested ina Simulated as wom position using a Tom Reobing Power Sample ID Tai Right Ts 3A 220 220 x Requirement 2 Patiem 20 Note: Tesied ina Simulaed as wom position wing a [9mm apertine Prism and Prism Imbalance Prismatic Power enim) Vertical Horizontal Sample ID Pass | Fadl ae Tait Immbalancetem/m) | _Imbalaoetem/m) bi Tal O19 ‘Oat (0.23 Base Out ¥ me Za5s Base Outs 0.50 faerone # = Base In $0.25 Note: Vested ina simulated as wom positon wai 219mm apenas 523 ye aa LABORATORIES tine 201 Dat: M1 Cetober 2010 Report: TS8 13-0141 Issue! Page: 40f6 Physical Requirements; Results: Pass Protectors are free from projections, sharpedges or other defects which are Likely to cause discomfort or injury during Drvp Ball Impact Resistance ‘Sample 1D TLosiion 3A3__[Tett Tad | Right BAS [Lei 3A6 [Right Protector Acceptance Criteria When each ty pe test is conducted as indicated above, a complete device shal fail if any of the Following occurs + piece fully detachod from the inner surface © fnetue ‘penetration of the rear surface + ens not retain Ignition; Resultc Pass ‘Samples did not ignite or continue to glow afler removal of the steel md Minimam Coverage Area; Result: Pass ‘The eye wire and lenscover in plane view an area of not less than 40:mum 1.57 in) in witthand 33 mm (1 30/n.tin height (elliptical) in front of each eye, centered on the geometrical center of the lens 64mm (2.52 in }PD. ye LABORATORIES Issued to: Day Sun Industrial Corp. Date: 11 Oetober 2010 No. 6, Lane 110, Sec. 4, Shiemen Rd Report: TS813-0l-1 Taina City, 704 Issue: 1 Taiwan Page: 5 of GIS — Lateral (Side) Coverage; Results Pass 622 623 624 m2 Protectors provide oontinoous lateral coverage (ie. ne openings greater than 1.$mm (0.6 in.) in diameter} from the vertical plane of the lenses tangential to a point not less thaw 10 mm (0.394 in.) posterior to the corneal plane and not fess than 10 mm (0.394 in) in height above ans not less than 10 mm (0.394in )n height below the horizontal plane centered on the eyes of the headform. The probe does not comtact the headform within the defined coverage area Prviector Acceptance Criteria ‘When eachty pe test is conducted as indicated in Sections 62.2, 62 3and 6 24 and, as applicable Section 62.6, a complete device shall fail if any of the following eocurs: * piioce Fully detachod trom the inner surface fracture penetration of the rear surface Jens not retained for the high-velocity test, the unaided eye observes any plece adhering to the eamtact paste, or observes contact paste ‘on the projectile or complete device Inthe case of plano protectors with a prescription lens carrist, contact of the prescription lens carrier with the headtom sdoss not constitute a failure igh Mass Impact Sample 1D. 3A BAB 3A9) TAL High Velocity Im; Sample 1D) act eH EE TAT FAIS AIS Penetration Test Sample 1D) BAIT BALI 3A19 Exe ‘Transmittance of Toxation Right Telt Right Teli ct Tosation Riga” Rig Ts Richt 90° T 1mm 153 Tel Ts Left 30 1s Left 90" 1 Om 15 153 (Lenses Only) Location Right Left Right Tet Lenses- Clear and Filter Lenses Velocity (iibee) Sample 1D) Left ) Riga LetiRight Pass Fal 3A2 197 196 TOOL Requirement Clear loz THL)2 45 NIA Tinted: 85> TIL) 28 L102LR 2090 Extra Dark 8» TU.) 202 1202 LR 20.80 =e LABORATORIES —a Dat: 11 October 2010 Report: TS#13-01-1 Ise! 1 Page) 8 of Sample Photog ph: LABORATORIES: 1. Client acknowledges that ICS Laboratories (CS) performs ‘esting services only as specified by Client. [CS does not design, ‘wauTant, supervise oF monitor compliance of products orservices ‘except ae specifically agresd fo in writing. By their wery nature, ‘esting, analysis, and other ICS services are limited in scope and ‘abject to expected mexsurenent vaiability. 2. Clisnt or Clients authorized representitive shall be afforded the ‘portunity to clari} tt requests and reasonable access to monitor test work, provisional to protecting the confidentiality of oherclisnts 3. ICS shall keep documents and information related to Client ‘confidential and will not disclose any such information to third [patics without clisat permission. ICS will, however, disslose any such informatien in response to legal process after providing ‘Client with a copy of such process. 4. ICS Reports apply only tothe standards ot procedures identified therein and to the sample (5) tested and or inspection (s) made Teast and/or inspastion results ate not indicative oF representative ‘ofthe qualities of the lot from which thesample was taken or of apparcutly identical or similar products 5. ICS Reports ae for he exclusive use of the Client, They and the mame [CS Laboratories, Ine, or its seals or insignia, are not to be ‘used by oron beha of Clisnts under any circumstances for any ‘Pirpose whatsoever, incluaing but not limited to use in advertising, publiciy material er inany other manner without ICS's prior writenapproval 5. Any-use by Client of ICS's Reports or the information ¢ontinad ‘herein i conditional upon timely payment of all fees 7. The name (s)listedas the “Issued to” party on test reports may not reflect theactusl entity submitting andor contracting the assessment 8. ICS shall sciain copies of Reports and applicable evidentiay test samples fora perigdat five yeas, at whieh time they will be disposed. If Clientrequests addiional copies of Reports during, ‘is period, an addi:ional charge will apply forthe preparation and delivery of suck reports. 9, Test reports are vald for certification purposes for one year from date of issue, inchudve of rete or variant additions which mest be performed withisone yearof dale of issue 1o=NoiM full retest 10. Samples and portioas thereof not destroyed in testing remain the [property of the Client are mined a maximum of 30 days, and ‘heteatler may be d sposod of or retumed toClientat ICS's ‘option 11 Client is responsible for procuring, at its cost, insurance protecting the value of 18 property ais samples. 12 For the safety of our personnel, Client must advise if samples ‘mown or suspectec 19 contain hazardous substances. Material ‘Safety Dat Sheet mast be provided upon request if avaiable 15. ICS represents that Services shall be performed within the limits ‘agreed with Client, and in a manner consistent with good Inboritory practice. NO OTHER REPRESENTATIONS TO- (CLIENT, EXPRESS OR IMPLIED, AND NO WARRANTY OR GUARANTEE 15 INCLUDED OR INTENDED IN THIS "AGREEMENT, ORIN ANY OTHER REPORT. OPINION OR DOCUMENT RELATED TO THE SERVICES. ICS DOES NOT (GUARANTEE PRODUCT COMPLIANCE OR CERTIFICATION, 14. ICS hereby objects any eontlictng terms contained in any ‘oder or acceptance submitted by Client TERMS AND CONDITIONS: 18, Schedules confimed upon acceptance of quotation. All reasonable efforts wll be made tocomply with conferred schedule. Guarantees are neither implied nor promised 16, Cemain work may besubsontractedto ICS authorized afiiate laboratoricsas required or applicable 17. Client agrees to pay any and all adcitionad costs acsociated with ‘unexpected or above stand ard commmieations andor ‘consultations with client or third partis as designated by client 18. Client agrees to pay any and all additional cost for work ditional tothe original scope of work as agreed to by client 19. Clicnt understands and agroes that “CS, inentering into this (Contract and by pesfomning servioes hereunder, does not assume, abridge, abrogate or undertake to dscharge any duty oF responsibilty of Client toany other party or parties. No one other than Client shail have any right 10 rely on any Report or ‘ofher representation of conduct of CS and ICS disclaims any. obligations of any nature whatsocver with respect to such person, (CLIENT AGREES, IN CONSIDERATION OF ICS UNDERTAKING TO PERFORM THE TESS) HEREUNDER, ‘TO PROTECT, DEFEND, INDEMNIFY, SAVE HARMLESS AND. EXONERATE ICS FROM ANY AND ALL CLAIMS, DAMAGES, EXPENSES. EITHER DIRECT OR CONSEQUENTIAL FOR INJURIES TO PERSONS OR PROPERTY ARISING GUE OF OR 1 CONSEQUENCE OF THE PERFORMANCE OF THE ESTING. INSPECTIONS AND REPORTS HEREUNDER ANDOR THE PERFORMANCE OF THE PRODUCTS TESTED. (OR INSPECTED HEREUNDER, UNLESS. CAUSED BY THE NEGLIGENCE OF ICS 20, TTS AGREED THATIF ICS SHOULD BE FOUND LIABLE FOR, ANY LOSSES OR DAM AGES. ATTRIBUTABLE TO THE SERVICES HEREUNDER IN ANY RESPEC SHALL INNO EVENT EXCEED TAE AMOUNT OF THE PAID BY CLIDN POR SUCH SERVICES AND CLIENT'S SOLE REMEDY ATLAWOR INIQUITY SHALL BE THERIGHT TO. RECOVER UP TOSUCH AMOUNT 21 Quotations are vali for 30days from date of issue. Terme: 30% Lahoratory(Testing fees invoiced ana payable upon ace ptance of quotation Remaining Laboratory/Testing fees invoioed and payable uponcompletion of services, 15 days net, Cancelled {Jobs will ke invoiced for work parformd andlor set-up costs incuned. Cancelled Purchase Onlers are subject to 10% service charge. Shipping costs incuned by ICS will be invoiced at cost +10% handing fee. A minimum USD $25.00 handling fee wil be invoiced. Shipping costs incurred by the cient w i be invoiced a USD $2500 handling fee 2, Inthe event thal payment is not received within 15 days of invoice date, Client agrees 1 pay late payment charge on the Unpaid balance equal to 1-1/2%6per month or the maximum shargs allowed by law, whichever is less, ant all costs and ‘expenses, itcluding attomey's fees where recovery of the sameis ‘pot prohibited by law, inowted by ICS in collecting auch 23. Allosts associated with oomplianse with any subpoena (3) for documents, testimony in a cour af law of for any other purpose ‘lating to work psafonned by ICS-n connection with work performed for hat Client, shal be paid by Client, Client shall also pay IC's then existing standad fee for consulting, deposition and tial testimony an all expenses related thereto 24, Canoells‘discontinued onlers: Client responsible forall ‘administrative and testing charges ep ts point of cancellation ICS Laboratories, Ine.» 1072 Industrial Parkway North » Brunswiek * Ohio “44212 USA F149 OT Nov om

You might also like