Professional Documents
Culture Documents
06/06/2018
Page 1
General
Number Of Pipes= 12
Number Of Junctions= 15
Pipes
Pipe Name Pipe Length Length Hydraulic Hydraulic Friction Roughness Roughness
Defined Units Diameter Diam. Units Data Set Units
Pipe Losses (K) Initial Flow Initial Flow Junctions Geometry Material Size Type Special
Units (Up,Down) Condition
Pressure Pressure Balance Balance (Pipe #1) (Pipe #2) (Pipe #3)
Assigned Pressure Pressure
Units Type Energy Concentration K In, K Out K In, K Out K In, K Out
3 0 psig Stagnation No No (P2) 0, 0
6 0 psig Stagnation No No (P4) 0, 0
9 0 psig Stagnation No No (P6) 0, 0
12 0 psig Stagnation No No (P8) 0, 0
(Pipe #4) (Pipe #5) (Pipe #6) (Pipe #7) (Pipe #8) (Pipe #9) (Pipe #10) (Pipe #11)
Assigned Pressure
K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out
3
6
9
12
(Pipe #12) (Pipe #13) (Pipe #14) (Pipe #15) (Pipe #16) (Pipe #17) (Pipe #18) (Pipe #19)
Assigned Pressure
K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out
3
6
9
12
(Pipe #20) (Pipe #21) (Pipe #22) (Pipe #23) (Pipe #24) (Pipe #25)
Assigned Pressure
K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out
3
6
9
12
Pump Table
AFT Fathom 9 (Model) AFT Fathom Model
06/06/2018
Page 3
Design Flow Design Flow Current Independent Ind. Variable Dependent Dep. Variable Pump Curve
Pump
Rate Rate Units Configuration Variable Units Variable Units Constant a
2 Vol. Flow Rate m3/hr Head Rise meters XY-Data
Design Flow Design Flow Current Independent Ind. Variable Dependent Dep. Variable Pump Curve
Pump
Rate Rate Units Configuration Variable Units Variable Units Constant a
5 13 m3/hr N/A
8 Vol. Flow Rate m3/hr Head Rise meters XY-Data
11 Vol. Flow Rate m3/hr Head Rise meters XY-Data
13 Vol. Flow Rate m3/hr Head Rise meters XY-Data
Pump Curve Pump Curve Pump Curve Pump Curve Runout Flow Runout Flow Control When
Pump Speed
Constant b Constant c Constant d Constant e Rate Rate Units Exceeded Only
2 XY-Data XY-Data XY-Data XY-Data
Pump Curve Pump Curve Pump Curve Pump Curve Runout Flow Runout Flow Control When
Pump Speed
Constant b Constant c Constant d Constant e Rate Rate Units Exceeded Only
5
8 XY-Data XY-Data XY-Data XY-Data 100
11 XY-Data XY-Data XY-Data XY-Data 100
13 XY-Data XY-Data XY-Data XY-Data 100
Reservoir Table
(Pipe #4) (Pipe #5) (Pipe #6) (Pipe #7) (Pipe #8) (Pipe #9) (Pipe #10) (Pipe #11) (Pipe #12)
Reservoir K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out
1
4
7
10
(Pipe #13) (Pipe #14) (Pipe #15) (Pipe #16) (Pipe #17) (Pipe #18) (Pipe #19) (Pipe #20) (Pipe #21)
Reservoir K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out K In, K Out
1
4
7
10
(Pipe #22) (Pipe #23) (Pipe #24) (Pipe #25) (Pipe #1) (Pipe #2) (Pipe #3) (Pipe #4) (Pipe #5)
Reservoir K In, K Out K In, K Out K In, K Out K In, K Out Depth Depth Depth Depth Depth
1 (P1) 0,5
4 (P3) 0,5
7 (P5) 0,5
10 (P7) 0,5
(Pipe #6) (Pipe #7) (Pipe #8) (Pipe #9) (Pipe #10) (Pipe #11) (Pipe #12) (Pipe #13) (Pipe #14)
Reservoir Depth Depth Depth Depth Depth Depth Depth Depth Depth
1
4
7
10
(Pipe #15) (Pipe #16) (Pipe #17) (Pipe #18) (Pipe #19) (Pipe #20) (Pipe #21) (Pipe #22) (Pipe #23)
Reservoir Depth Depth Depth Depth Depth Depth Depth Depth Depth
1
4
7
10
(Pipe #24) (Pipe #25) Pipe Depth
Reservoir Depth Depth Units
1 meters
4 meters
7 meters
10 meters
Tee or Wye Name Object Inlet Elevation Initial Pressure Initial Pressure Database Tee/Wye
Defined Elevation Units Units Source Type
14 Detailed 90 7, 9, 10
15 Detailed 90 8, 11, 12