You are on page 1of 3

CEMENTING

SentinelCemTM Cement


SentinelCem cement is specifically designed to cure losses e slurry would become liquid again, for a few cycles, if the
and enable further drilling and help achieve zonal isolation by shear is re-applied. e features such as thixotropy, bonding
accomplishing intended top of the cement. e solution can be to the formation, and dynamic pumping time independent of
easily applied to losses varying from seepage to a complete loss temperature, increases the probability of curing the losses with this
of returns. However, this solution is most applicable for partial to cement system. e cements slurry develops both early gel strength
severe to total losses that can not be cured by particulate and compressive strength when the shear is reduced.
materials alone.
Benefits and Applications
Fractured, vugular, cavernous or highly-porous formations
• Lower rheology during pumping helps the SentinelCem cement
generally have high permeability and/or large openings that can
enter the thief zone readily, but the buildup of gel strength due to the
accept considerable volumes of drilling fluid. If fractures and voids
reduction of shear helps prevent the slurry system from flowing into the
are large, they will not be plugged by the particulate materials that
thief zone continually
are typically used. When this occurs, drilling further is impeded
and this may necessitate setting additional casing strings or • Early static gel strength coupled with early compressive strength helps
abandonment of the well. In addition, cementing operations are plug thief zones and mitigate further lost circulation
susceptible to the same severe losses to which the drilling fluid
• Decreases the need for remedial cementing operations
succumbed. For such situations, a special system is necessary for
successfully plugging the thief zone in order to continue drilling • Minimizes lost fluids and maintains drilling efficiency
and establish a reliable wellbore architecture. helping manage operational costs

Halliburton has developed a lightweight cement specifically • Acid solubility enables optimally oriented perforations and
for when lost circulation has occurred. is cement slurry stimulation treatments
contains selected components that impart the needed rheological
and mechanical properties to the cement to help cure losses.
SentinelCem cement can be made acid soluble and hence can be
used across producing zones.

SentinelCem cement is very easy to mix, has a low viscosity to aid


in full-coverage placement while pumping, and develops early gel
strength and compressive strength. ese properties help in curing
losses when the slurry enters the fractures and small or medium
vugs. As the slurry enters the loss circulation zones the slurry
velocity is reduced and the slurry begins to gel due to the reduction
in shear rate.
CEMENTING

SentinelCem™ Cement –ThickeningTime

HAL33264
SentinelCem cement did not pump-off during this test and had a viscosity of ~ 30 Bc even aer 24 hours at
190°F (87.8°C) indicating optimum viscosity for full-coverage placement.

SentinelCem™ Cement – Compressive Strength

HAL33265

SentinelCem cement achieved 10-second gel strength of 25 lbf/1002 and 10-minute gel strength of
140lbf/1002, reaching compressive strength of 50 psi in approximately 1 hour.
CEMENTING

SentinelCem™ Cement – ON/OFFTest in Thickening Time Device

HAL33266
is chart shows three on-off tests of SentinelCem cement in a consistometer. e slurry gelled when le
static in each of the three times and then regained circulation when shear was applied.

For more information on SentinelCem™ Cement,


please call your local Halliburton representative or email us at cementing@halliburton.com.
© 2012 Halliburton. All rights reserved. Sales of Halliburton products and services will be in accord solely with the terms and conditions contained in the contract
between Halliburton and the customer that is applicable to the sale. H08282 05/12

www.halliburton.com