You are on page 1of 2

1. ALL DIMENSIONS ARE IN MM.

AND LEVELS ARE IN METERS UNLESS SPECIFIED


OTHERWISE.
2. SEISMIC ZONE: ZONE-V
3. REFERENCE CODE:-
 BRIDGE RULES (RAILWAY BOARD)
 IRS CONCRETE BRIDGE CODE.
 IRS BRIDGE SUBSTRUCTURE & FOUNDATION CODE.
 RDSO-GUIDELINES ON SEISMIC DESIGN OF RAILWAY BRIDGE.
 IRC-78
 IS-456
 IS-SP-16
4. CONCRETE GRADE:-

 ABUTMENT & PIER : M-35 (DESIGN MIX)


 PILES, PILE CAP, ABUTMENT CAPS: M-35 (DESIGN MIX)
 RETURN WALL : M-35 (DESIGN MIX)
 LEVELING COURSE- 1:3:6

5. REINFORCEMENT BARS SHALL BE H.Y.S.D OF GRADE Fe-500 CONFORMING TO


IS:1786-2008
6. ANGLE OF REPOSE OF BACKFILL SHALL NOT BE LESS THAN 30°
7. WEEP HOLES SHALL BE OF 75/100 DIA PVC PIPES STAGGERED @ 1000 C/C BOTH
HORIZONTALLY & VERTICALLY THROUGH RETURN WALL & ABUTMENT
8. LAPPING OF BARS SHALL BE IN STAGGERED POSITION AND NEAR THE POINT
OF MIN STRESS AS FAR AS PRACTICABLE. THE LAP LENGTH SHOULD NOT BE
LESS THAN 65D FOR M35 GRADE OF CONCRETE DEVELOPMENT LENGTH FOR
M35 IS 46D WHERE “D” IS DIA OF BAR
9. SUPERSTRUCTURE OF PSC SLAB IS AS PER RDSO STANDARD
DRAWING NO: RDSO/B-10274
10. BEHIND ABUTMENT BOULDER FILLINGS & BACK FILL MATERIALS SHALL BE
PROVIDED AS SPECIFIED. THE BOULDER FILLING SHALL CONSIST OF WELL
HAND PACKED BOULDERS & COBBLES. THICKNESS NOT LESS THAN 600MM