Fuse-Load Break Switch Combination Unit up to 24 kV Introduction QM, QMC & PM are parts of SM6 product range. This SME range is, made up of modular units and used for the MV section of MV/LV ‘substation in secondary distribution system up to 24kV. Application : I I I (QM Is a fuse load break switch combination unit with striker fuses mechanism (a blown fuse causes the switch to open).Itcan be used if oH oH {or transformer protection, cable protection, etc. > o b ‘QMC is similar to OM but equipped with three CT's for metering or protection purposes. PM isa fuse load break switch unit without strker fuses mechanism. 4 TA “ ' This QM, QMC, OR PM is normaly together in the system with other oI ot 4 | parts of SM6 product range such as IM, IMC, CM, DM, DM2, etc. in accordance with the design of a distribution system. Characteristic : Rated maximum Voltage (kV) 2 24 Rated voltage (kVrms) 72 12 175 24 Rated insulation level = 5OH2 for 1 min (kVims) 20 28 38 50. = impulse 1.2/50 wS (kVrms) 60 7 95 125 Rated current = load break switch (A) 400/630 400/630 = busbar (A) 630 630 ‘Short time withstand current = Tor rated current 400 A (kA/is) 125/145 125145 ~ Tor rated current 630 A (KA/is) 125/145 125/145 16 16 20 20 ** See fuse selection table Scynelder Load break switch or disconnector and earthing switch : ‘Bago staaton of an SME24 stb inal Inte moo aoam cowards exhaust 16445, iG AAPA. 4 ste intemal are prtecton Internal are withstand : (in accordance with IEC 8271-200} = v6.24 1D 126A 15, IACAFLR BIAC AFL. 1D IBkA Is, IAG:A-FLR A IAC:A-FL (Standard) 1D 20kA Is, IAG:A-FLR &IAC:A-FL Protection index : Classes Pl (nsuiating partition 1 Loss of service continuity classes: LUSC2A (LSCt for metering functions) Units in switchboard PX '=Botwoon compartments: IP2X for M24 "© Cubicle: KOS for S624 Electro-magnetic compatibility : 1 relays: 4 KV withstand capacity, as per recommendation IEC 60801 .4 = compartments: 10 electrical fold = 40 dB attenuation at 100 Miz - 20 B attenuation at 200 MHZ 1B. magnetic field: 20 GB attenuation below 30 Mhz. ‘Temperatures : “The cubicle must be stored and installed in a dry area froe from dust and wath limited temperature variations '© for stocking: from -40°C to +70°C, for working! from -5°C to +40°C, © other temperature, consult us, = 40 dB attenuation at 100 Miz ~ 20 dB attenuation at 200 MHZ 5 magnetic field: 20 GB attenuation below 30 Mrz. Basie Equipment : 'SF6 functional load break switch and earthing switch, Three phase busbar 650 A. Cltoperating mechanism (OM & aMc), CIT operating mechanism (PM) Three fuses PM) Three stiker fuses (QM & OMC}. ‘Mechanical indication for blown fuses (QM amc). Voltage incicators, Downstream earthing switch, Heater 50 W, 220¥, Three currant transformer (AMC). Standard Recommendation : IEC standards : 6271-200, 5271-1, 62971 -103, 62271-105, 60255, 6271-100, 6271-102, 61859: 61889-3, 60044-8, 2271-206, 6271-304 UTE standard for 24k NEC 13,100, NEC13.200, NFC84.190, NFC 64.160 EDF spesification for 24KV HN64-S-41, HNB4-5-43 Optional Accessories : Motor operating mechanism, Auliary contacts Large LV compartment on top ofthe cubicle, = 450mm. key type interlocks, Incication contact for blown fuses. Shunt tip or undenotage release, Ring CT's + Ampere meter (QM) “other requirements please consul us. ‘Overall dimension’ ‘om.Pw|_aMc Width 00 men | 625 mr Depth 7080 me | 7030 mn Height 1600 men | 7800 men LV Compartment (hy [450mm | 450mm, ‘Approximate weight 140g] 190Kg) ‘Cable connec. height | 00mm | a0Oren Cable entry or exit : "= Through left or right side. "= Rear or front with conduit "© Top entry and bottom entry type (or top entry the depth of cubicle is acced by 600 ‘mm and the height is added by 400 mr). ‘GMC must be installed with a 100mm deep pan, ‘QM with ring CT's mustibe installed with en. Colour: additional 150 mm deep pan and trench, RAL 9003 ‘Auxiliary power supply : Cabling ‘or electrical operating mechanism ‘Through trenches {when applicable) ‘Type of cable: single core DG:110V or AC: 220V S0He 2av tov 50H 48y Lee) yf te l Ll = — oo — = => om > Sie View FrontView 16 kAV1S as IAC :A - FLR (bottom exhaust gas) ‘Transformers Protection Fuse rating for SM6 protection units such as the PM, QM and QMC depend among others of the following criteria © sence voltage transformer rating "fuse technology (manufacturer) Different types of fuses with medium loaded striker may be instaled © Solefuse fuses as per standard UTE NOF 64.210 = Fusarc OF fuses as per IEC recommendation 282.1 and DIN dimensions 43.625 Example: For the protection of a 400 KVA transformer at 10 ky, select either Solefuse fuses rated 43 A or Fusarc fuses rated 50 A Rated Rating = L_ Weight voltage (A) (emmy (mm) (kg) Oo) 72105 m2 88S. 12 691020 eS 2eto40 2027 soto 100 292785 125 428646 wm 651020 28051 2tow 2 BT 50t0 442785 AA wototo 4S Please consult us on installation of ‘uses from other manufacturer Fuse dimensions ‘Solefuse (UTE standarc) y poss belle |___ Rated ating = Leight, oe 3 (erm) (rm) kg) 728810125 460 852 2 100 175 60 2 631068 Fusare CF (DIN standarc) Fuse Selection Table Selection table (rating in A, no overload, -5°C < 8 < 40°C) Please consult us for overloads and operation over 40°C. Type ot Service Transformer rating (kVA) Rated fuse (ayyo” 25 $0 100 125 160 200 250 315 400 500 690 800 1000 1250 1600 2000 2500 ayy Solefuse _(UTENFC standards 13.100.64210) 3 55. 6316 315 15 8 8 63 68 6 72 10 63 63 16 16 15 S15 315 68 63 68 OB 15 63 63 6 6 6 6 6 8 4 8 4 48 08 2 63 63 63 63 6 6 6 6 8 8 8 4 8 68 24 Solefuse (General case, UTE NFC standards 13.200) 33 16 16 315 315 815 63 63 100 100 72 35 63 6 6 5 35 6 63 68 8 80 100 15 66 63 16 16 16 315 S15 —MONMON 63 80 100 125 125 10 63 63 1 16 16 315 o15 15 4 4 68 80 80 100 2 138 63 63 63 16 16 16 16 315 315 315 4 68 63 80 175 15 63 63 6 16 16 16 16 315 315 15 49 49 63 80 2 63 63 63 63 16 16 16 16 315 915 315 4 SOS 2 2 63 63 63 63 16 16 16 16 16 315 315 315 8 68 6B Fusare GF and SIBA® (General case fo QM, NB and ONC cubile according to IEC 6227-108) 33 2 80088 100«125 «125 «160" 200" 72 5 0 16 315 40 40 80 63 80 80 125 125 t60" 55 10 16 318 315 40 60 60 68 80 100 125 12 100" 100" 6 0 16 5 315 40 50 60 68 80 80 125 125 160% 160" 66 10 16 25 315 40 60 60 68 80 80 100 125 125 160" 10 63 10 16 2 % 315 40 90 90 63 60 80 100 100 125" 200" 2 i 63 10 16 20 25 25 315 40 50 50 63 80 100 100 125” 160" 138 63 10 +16 16 20 2 16 315 4 60 60 68 80 80 100" 125" 125° 175 15 63 10 10 16 16 20 2% 315 40 50 50 69 80 80 100" 125" 125° 2 63 63 10 10 16 16 2 % 315 40 40 50 50 63 80 100" 1257 24 2 63 63 10 10 10 6 0 % 2 a5 4 40 50 60 80 8 100" (1) = SIBA fuses Fuse rating for SM6-24 protection units such as PM, QM, QMB and QMC depend, among other things, on the folowing criteria: service voltage transformer rating it fuse technology (manufacturer) Different types of fuses with medium loaded striker may be installed: 1g Solefuse fuses as per standard UTE NCF 64.210 10 Fusarc CF Fuses as per IEC recommendation 60.282.1 and DIN dimensions 43.625 For tuse-switch combination unit type QM,QMB, GM, refer only to the selection table and reference lst of fuses, For all other type fuses, consult us. Example: for the protection of a 400 kVA transformer at 10 KV, select either Soletuse fuses rated 43 A or Fusarc CF fuses rated 50 A. PTSchneider Indonesia Sales ofc Sale Representative Bri clnan eens Sek rie Snnd ssterare abecider-sletriceom ‘MICLEAFS920026N

You might also like