American Welding Society®

OVERVIEW OF MAJOR CHANGES


AWS D1.1/D1.1M:2015 STRUCTURAL
WELDING CODE – STEEL
For full details of all changes, please refer to the foreword of AWS D1.1/D1.1M:2015
See full PDF or preview file (https://pubs.aws.org/Download_PDFS/D1.1-2015-PV.pdf)
OVERVIEW OF MAJOR CHANGES
AWS D1.1/D1.1M:2015 STRUCTURAL
American Welding Society® WELDING CODE – STEEL

GENERAL

• All tubular provisions, tables, and figures moved to a new Clause 9,


“Tubular Structures” with a corresponding new section of commentary,
divided as follows:

 Part A – Design
 Part B – Prequalification
 Part C – WPS Qualification
 Part D – Performance (Welder) Qualification
 Part E – Fabrication
 Part F – Inspection

• Incorporation of AWS A5.36/A5.36M, Specification for Carbon and Low-


Alloy Steel Flux Cored Electrodes for Flux Cored Arc Welding and Metal
Cored Electrodes for Gas Metal Arc Welding, fixed and open
classification requirements

• ASTM A709 Grades 100 and 100W deleted and Grade HPS 100W
[HPS 690W] added
OVERVIEW OF MAJOR CHANGES
AWS D1.1/D1.1M:2015 STRUCTURAL
American Welding Society® WELDING CODE – STEEL

CLAUSE 2 - DESIGN

• Clarification regarding calculation of effective throat of a combination


PJP flare bevel groove weld and fillet weld

• Additional provisions for wrapping welds on opposite sides of a common


plane to permit seal welding

• Fatigue curve cases and figures revised to align with the American
Institute of Steel Construction, AISC 360
OVERVIEW OF MAJOR CHANGES
AWS D1.1/D1.1M:2015 STRUCTURAL
American Welding Society® WELDING CODE – STEEL

CLAUSES 3 AND 4 -
PREQUALIFICATION AND QUALIFICATION:

• Clarification of conditions for backing other than steel in prequalified


WPSs

• Reorganization and update of Prequalified Base Metal and Filler Metal


Combinations for Matching Strength and Alignment with Prequalified
Minimum Preheat and Interpass Temperature

• New table for prequalified filler metals (including AWS A5.36)

• New figure for prequalified fillet weld joint details

• New figure for prequalified CJP groove, T-, and corner joints

• Clarification of CVN Test requirements for sub-sized specimens


OVERVIEW OF MAJOR CHANGES
AWS D1.1/D1.1M:2015 STRUCTURAL
American Welding Society® WELDING CODE – STEEL

CLAUSE 5 - FABRICATION:

• Reorganization of AWS Filler metal specifications for GMAW and FCAW


including AWS A5.36

• Clarification of baking requirements for low-hydrogen electrodes for


ASTM A514 and A517 steels

• Clarification of preheat and interpass temperature requirements

• Updated requirements for backing thickness

• Updated requirements for substrate cleanliness

• Clarification of provisions for oxygen gouging

• Clarification when locations of the depth of the web from tension


flanges of beams or girders are considered outside the tension zone for
tack welds and construction aid welds

• Revisions to the location and sequence of member and element splices

• Clarification when minimum size fillet welds are exempt from


reinforcement and convexity limitations
OVERVIEW OF MAJOR CHANGES
AWS D1.1/D1.1M:2015 STRUCTURAL
American Welding Society® WELDING CODE – STEEL

CLAUSE 6 - INSPECTION:

• Clarification regarding retesting based on quality of work

• New table for qualification and calibrations requirements of U/T


equipment

• Clarification regarding calibration for sensitivity and horizontal sweep of


U/T equipment

ANNEXES:

• New Figures to clarify effective throat for various joint types and
combinations

• Sample welding forms extensively revised –


see http://go.aws.org/D1forms
American Welding Society®

ORDER YOUR COPY FROM


THE AWS BOOKSTORE TODAY

www.aws.org
8669 NW 36 Street, #130
Miami, FL 33166

You might also like