‘Symptom Test ‘You see unknown frequencies below — | High Resolution Analysis the running speed. Low Frequency Analysis “You see a peak (or peaks) that looks like | Synchronous Analysis aharmonic of the turning speed, but you are not completely sure. You are trying to confirm unbalance, misalignment, or Tooseness. High Resolution Analysis with 2xTS peak marked “You need to distinguish between unbalance versus resonance. Bump Test (equipment running) Bump Test (equipment off) High Resolution Analysis with IxTS peak marked ‘You need to confirm if vibration is bearing related (non-synchronous). High Frequency Analysis Synchronous Analysis ‘You suspect a resonance problem. Bump Test (equipment running) Bump Test (equipment off) Coastdown (peak hold)~no tach signal Coastdown (peak’phase)--tach signal is evailable "You suspect an electrical problem. __| High Resolution Analysis with 2xTS peak marked High Resolution Analysis with 1xTS peak marked Rotor Bar Test (motor current) "You suspect a rolling element bearing Bearing/Gear - PeakVue failure High Frequency Analysis ‘You notice that the equipment speed _| Order Tracking varies during data collection and is spearing the spectrum. “You are unstre of taming speed Turning Speed Detection ‘You suspect gear problems Bearing/Gear - PeakVue High Resolution Analysis