OPC shall conform to ASTM C 150 Type I or BS EN 197
Heat of Hydration < 325 kj/kg (ASTM C 186) C3A – 8%< C3A <13% (ASTM C 186) Acid Soluble Alkali Content < 0.6% Fineness: Air Permeability Apparatus (ASTM C 204) Soundness: Autoclave Expansion (ASTM C 151)
ASTM C 150 – 2007 requirements
Chemical Composition
Magnesium Oxide (MgO) < 6% (ASTM C114)
Sulfur trioxide (SO3) (ASTM C114) If C3A < 8% : < 3% If C3A > 8% : < 3.5% Loss on Ignition < 3% (ASTM C114) Insoluble Residue < 0.075% (ASTM C114) Equivalent alkalies < 0.6% (required only when aggregates are found reactive) (ASTM C114)
Physical Requirements
Air Content of Motor by volume < 12% (ASTM C 185)
Fineness Turbidimeter test Average value > 160 and individual value > 150 (If test fails in air permeability test only this test is needed) (ASTM C 115) Air permeability test Average value > 160 and individual value > 150 (ASTM C 204) Autoclave Expansion < 0.8% (ASTM C 151) Strength (Compressive Strength) (ASTM C 109/109M) 3 days : 12.0 MPa 7 days : 19.0 MPa 28 days : 28.0 MPa (optional) Time of Setting, Vicat Test (ASTM C 191) Initial Setting : > 45 minutes Final Setting : < 375 minutes False Set, final penetration : < 50% Gillmore test, Initial Set : > 60 Minutes (ASTM C 266) o Final Set : <600 Minutes