You are on page 1of 8

IMPELLER TRIM CALCULATOR

1) Enter the pump test curve impeller diameter in cell B17


2) Enter the reduced or increased impeller diameter in cell B21
3) Enter up to eight flow values in cells C17 - J17
If there are fewer than eight points enter the last flow multiple times
4) Enter the corresponding heads in cells K17 - R17
If there are fewer than eight points enter the last head multiple times
5) Enter the flow efficiencies (%) in cells C18 - J18
If there are fewer than eight points enter the last efficiency multiple times
6) Calculated flows, heads & BHP will appear in the blue cells
7) Click on the tabs to view the curves

Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8
13.5 250 500 750 1000 1250 1500 1750 2000
Pump Ef 50 60 73 80 84 86 86 83
BHP 25.9 42.3 50.6 59.3 66.9 72.7 75.5 76.1

12.5 231 463 694 926 1157 1389 1620 1852


BHP
0.926
0.857 20.5 33.6 40.2 47.1 53.1 57.7 60.0 60.4

Trims greater than 10% can reduce hydraulic efficiency.


H1 H2 H3 H4 H5 H6 H7 H8
205 201 195 188 178 165 147 125

176 172 167 161 153 141 126 107


250

200

150

100

50

0
0 500 1000 1500 2000
13.5

500 2000 2500


200

180

160

140

120

100

80

60

40

20

0
0 200 400 600 800 1000 1200 1400 1600 1800
12.5

0 1400 1600 1800 2000


250

200

150

100

50

0
0 500 1000 1500 2000
13.5
12.5

500 2000 2500