DISTANCE (mm) 700 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 700

CABLE 2 Y2 0 0 0 0 0 0 0 0 0 0 26 50 70 85 100 110 100 85 70 50 26 0 0 0 0 0 0 0 0 0 0

CABLE 1 Y1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
CABLE 3 Y3 0 0 0 0 0 0 0 0 0 0 -26 -50 -70 -85 -100 -110 -100 -85 -70 -50 -26 0 0 0 0 0 0 0 0 0 0

C
L

DISTANCE (mm) 700 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 700

CABLE 1 1060 1050 995 895 775 655 550 455 370 300 240 190 150 125 110 100 110 125 150 190 240 300 370 455 550 655 775 895 995 1050 1060

CABLE 2 760 750 715 650 560 485 410 345 290 240 195 160 135 115 105 100 105 115 135 160 195 240 290 345 410 485 560 650 715 750 760
CABLE 3 460 450 435 400 350 310 270 235 200 175 150 135 120 100 100 100 100 100 120 135 150 175 200 235 270 310 350 400 435 450 460

A PLAN AND TENDON PROFILE


SCALE 1:80

CABLE 1 CABLE 1
(1/1213L) (1/1213D)

CABLE 2 CABLE 2
(1/1213D) (1/1213L)

CABLE 3 CABLE 3
(1/1213L) (1/1213D)

C2 C1 C3

1C SECTION AT LEFT 1D ELEVATION AT LEFT 1E SECTION AT MIDSPAN 1F ELEVATION AT RIGHT 1G SECTION AT RIGHT
SCALE 1:35 SCALE 1:35 SCALE 1:35 SCALE 1:35 SCALE 1:35

MAX NO. OF STRANDS 12's


ANCHORAGE TYPE 1213 SEQ. CABLE NO. (75% UTS)
PLATE SIZE (A) 215
ANCHOR HEAD DIAMETER (B) 150
1 1 50%
ANCHOR HEAD THICKNESS (C) 52
BEARING PLATE DEPTH (D) 85
TRUMPET LENGTH (E) 270
2 2 100%
DUCT SIZE - INT. Ø (F) 70
TYPE I
RECESS SIZE (G) 280 3 1 100%
RECESS SIZE (H) 230
RECESS THICKNESS (I) 100 4 3 100%
MIN STRAIGHT LENGTH (J) 900

1J PRIMARY BURSTING STEEL 1J SPX STRESSING ANCHORAGE


TYPE II
SCALE NTS SCALE NTS

CABLE JACKING ELONGATION


TENDON
NO. FORCE (kN) (mm)

1 12's 1652.40 195.80


TYPE III
2 12's 1652.40 198.20
3 12's 1652.40 201.00
1K BURSTING STEEL DEAD-END ANCHORAGE (1213)
SCALE NTS

THIS REVIEW DOES NOT RELIEVE THE CONTRACTOR OF


FULL RESPONSIBILITY AND ACCOUNTABILITY FOR THE
1L LIFTING HOOK FAILURE OF THE FACILITIES AND STRUCTURE(S) DUE TO
FAULTY DESIGN AS DESIGNER AND FABRICATOR
SCALE NTS 1M CAMBER DIAGRAM
SCALE NTS

SUBMITTED BY: PREPARED BY: PROJECT & LOCATION: CHECKED & REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY: SHEET CONTENT: SHEET NO

REPLACEMENT OF PUNONG REPUBLIC OF THE PHILIPINES


BRIDGE AND APPROACHES DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS
FROM TEMPORARY TO
REGION IV-B MIMAROPA SHOP DRAWING OF AASTO GIRDER 2
OFFICE OF THE REGIONAL DIRECTOR TYPE IV L=29.40m
MICHAEL D. BARAWED PERMANENT ALONG SIBUYAN RENATO L. ESCUADRO ARMANDO G. ESTRELLA, CESO IV WILFREDO S. MALLARI EDSA DILIMAN, QUEZON CITY REINFORCEMENT DETAIL 2
ENGINEERING HEAD CHIEF PLANNING and DESIGN DIVISION ASSISTANT REGIONAL DIRECTOR REGIONAL DIRECTOR