When analyzing a 2G network, engineers tend to focus on voice call related issues, such as call
quality, call failures and RF conditions. Engineers emphasize the importance of enhancing
voice call performance mainly by optimizing coverage or attempting to identify the root cause
of voice call failures due to adjacency definition, power control or handover parameter. With
the deployment of 3G networks, engineers must also take notice of network performance
data including maintaining balance between throughput, capacity and radio quality, and also
IRAT (Inter Radio Access Technology Handover), in order to ensure a seamless transition
between 2G and 3G networks.

Following are the key attributes followed by Top


Telecom Vendors like Ericsson, Huawei & NSN for
2G & 3G KPI Improvement by parameter
optimization.

TCH Blocking

If the utilization of a cell is low and its still


having blocking check for hardware issue
For high utilized cell, try changing FRL FRU
Parameters in the cell
Enable Direct Retry in the cell
Enable Traffic based handovers
If still there is blocking add TRXs if configuration is less than 4 in case of ultra/flexi and 6
in case of MR

SD blocking

Increase SDCCH timeslots by monitoring trend of SDCCH blocks vs SDCCH attempts—SD


dimensioning
Increase the Value of HYS at LAC boundary cells
Implement Dynamic SDCCH feature
Implement increased SDCCH capacity feature
Perform physical optimization at LAC boundary cells

TCH drop

Check for frequency hit


Change RLT to 28, ARLT to 44
Try reducing the value of RXP
Change QMRG parameter to 3—check for degradation in DL quality as well
Check for hardware issue
http://www.reckontalk.com/2g-and-3g-kpi-improvement-by-parameter-optimization-nsn-ericsson-huawei/ 1/2
17/6/2014 2G and 3G KPI Improvement by Parameter optimization (NSN, Ericsson, Huawei) | Reckon Talk

Check for MO, MS,HSN


Physically optimize if its a cell specific issue
Check for end to end SYNC BTS,BSC & MSS,MGW

HOSR

Check for the neighbours which are causing degradation in HFR


Delete the neighbour if its unwanted
Check for hardware issue in the target cell
Change the value of SL to -90 and QMRG to 3(check for degradation in DL quality as well)

TASR

Check for the 7745 channel failure alarm. Lock the faulty TRXs/timeslots
Change TRP parameter to 1 and BFG to 2
Follow steps mentioned in TCH blocking KPI if TASR is degraded due to TCH blocking

SD drop

Lock the timeslot which is having high SD drop(in case of channel failure alarm starting
with 02)
Change T200S(BCF level) to 1000
Change RXP to -102

Paging Success Rate

In case of high paging load, perform LAC splitting


Change AT (Repaging attempts)=2, INT(Repaging interval)=500 ms