Ultrasonic Anemometer 3D Technical Data:

The Ultrasonic Anemometer 3D s­ ignal processor (DSP) within Wind speed and wind direction
serves for the ­three-­dimensional the ­propagation time of the Measuring range: 0.01-65 m/s Azimuth 0°-360°,
measurement of the wind ­ultrasonic signals, based on an 0.01-65 m/s Elevation 0°-180°
direction and wind speed. accuracy of 32 bit. Accuracy: WG +/- 0.1 @  5 m/s or 2% rms
The anemometer is free from The RS485/RS422 interface WR +/- 2°
wear and maintenance, and allows a real-time-output of even Resolution: Wind speed = 0.01m/s
needs no further calibration. extensive telegrams without angle = 1°
For winter operation also under restricting the maximum rate of Acoustic virtual temperature
extreme weather conditions the measuring value acquisition. Measuring range: -40 °C up to +70 °C
instrument is equipped with a The instrument offers extensive Accuracy: ± 0.5 Kelvin in the range
­heating. In addition, the instru- statistic functions, such as gli- from -40 °C to +60 °C
ment calculates the acoustic ding averaging, standard deviati- Resolution: 0.1 Kelvin
virtual-temperature from the on, covariance etc., which can be
propagation times of the sound selected via the digital interface. Output of measuring data
of each measurement path. The gliding averaging can alter- Measuring rate: Typ. 3.5 ms at 20 °C
Due to its maximum measure- natively be set in vectorial or Output rate: 1 ms up to 60 seconds,
ment rate, limited only by the scalar form, and for each settable in 1-ms-increments
propagation time of the sound, ­parameter equally or differently. Data output digital: RS485/RS422, FD, HD, bus mode
the instrument is especially sui- The digital interface (RS485/422) Baud rates: 1200 up to 921600 Bps
ted for the inertia-free measure- allows the access to all data and Analogue output: 3 analogue channels for output
ment of gusts and peak values. status information of the instru- of X, Y, Z vector components or
All calculations are carried ment up to the writing of a user- Horizontal windspeed,
out by a high-capacity digital specific output telegram. wind direction and virtual
temperature
0(2) ... 10 V at min. 4 k
(0)4 ... 20 mA at max. 400  load
16 Bit
Analogue inputs: optional; 3 x voltage input
Ultrasonic 0-10 V, 16 Bit,
Anemometer 3D
meas. error  0.1%.
Output formats: ASCII Thies, NMEA 0183 Version 3,
user-definable, status
Features
Memory: for burst-measurement-mode
Power Supply Unit Statistic: turbulence intensity, longitudinal,
Terminal Box
transversal, vertical standard
deviation x, y, z and T (vT)
Co-variances: xy, xz, yz, yT, zT
RS 422 / RS 485 Firmware-update: Uploadable via serial
and/or
0/2-10V or interface (RS485)
0/4-20 mA General
Operating voltage: 12-24V AC/DC, power
consumption:
PC-Software Datalogger 2.5 VA, heated 150 VA
The heating can be switched off,
• Visualisation • Recording and is temperature-controlled
• Recording • Controlling Temperature range: -40 °C up to +70 °C
• Monitoring • Data Processing with heating: -75 ... +70 °C
Protection: IP 65
Mounting: on mast tube 1.5"
Housing: V4A stainless steel und sea-water-
proofed anodized aluminum