Introduction PUMP DESCRIPTION
The Grundfos HS horizontal splitcase pump is an unstop- • The pumps are non-self-priming, centrifugal volute • Grundfos HS pumps are available in three different
pable workhorse. The HS delivers high efficiency perform- pumps with radial suction and radial discharge ports variants:
ance and low life-cycle costs. The highly reliable hydraulic and horizontal shaft. 1. Pump with motor and base frame.
design combined with the service-friendly layout of the 2. Bare shaft pump with base frame.
splitcase housing assures maximum benefits for the user. • Suction and discharge flanges are PN 16 according to 3. Bare shaft pump; ie pump without motor and without
EN 1092-2 (DIN2501). base frame.
All HS pumps are tested to ensure the performance require-
ments are achieved prior to delivery. The HS is a well-built, • The pump is long-coupled with a totally enclosed fan- • The split-case construction enables removal and
reliable splitcase pump proudly offered by Grundfos – the Applications cooled standard motor with main dimensions to IEC dismantling of the internal pump parts, e.g. bearings,
splitcase pump market leaders! The Grundfos HS pumps are used in these main fields of and DIN standards and mounting designation B3 wear rings, impeller and shaft seal, without disturbing
application: (IM 1001). the motor and pipework.
Technical Data
Flow, Q: 10 to 2500m3/hr Commercial systems • The mechanical shaft seal has dimensions according • Replaceable case wear rings protect the pump casing
Head, H: 5 to 148m • Air-conditioning and chilled water system to EN 12756. while reducing maintenance costs and maintaining
Motor, range: 1.5 – 600kW • Water condensing systems and cooling towers high operating efficiencies.
Motor, cycles: 50 Hz • District heating plants and heating systems • The rotating assembly is dynamically balanced
Operating Pressure: 16 bar, max. according to ISO 1940 class G6.3. • Pump and motor are mounted on a common base
Liquid temperature: Up to 100°C Industrial systems frame in the form of a welded, steel C-channel profile.
Discharge Sizes: 50 – 350mm • Process cooling and chilled water systems • Impellers are double suction providing long operating,
Impeller Sizes: 242 – 630mm • Industrial heating systems corrosion free life. Impellers are constructed in • Bronze shaft sleeves protect the shaft and help with
• Washdown and cleaning systems ASTM B584 bronze and are hydraulically balanced. fixation of the impeller.

Water distribution
• Public waterworks
• Non-potable water systems

Irrigation and agriculture


• Field irrigation (flooding)
• Sprinkler irrigation
SELLING FEATURES
Pump casing Bearing Housing
• Compensated double volute design virtually eliminates • Grundfos superior design combines seal and bearing
radial forces caused by a hydraulic imbalance inherent chambers to allow inspection without removing the top
in pump volutes half of the pump casing – saving time, reducing the use Coupling guard - stainless steel

• Double volute design extends seal and bearing life, of lifting equipment, and decreasing the safety risk
minimizing noise and vibration, and improving • Compact, robust housing construction has a 360-degree
operating efficiency – meaning less wear and lower machined fit and limits shaft deflection and optimizes Motor
maintenance costs alignment

Impeller
• Extended vanes and enlarged eye contribute to a Coupling - Grid
reduction in vibration and noise

Coupling
• Grundfos specified grid coupling designed to meet the
pump torque requirements provides long service life
and reduced maintenance costs

Shaft

Impeller
Shaft sleeve

Base plate

Wear ring

Shaft seal

Bearing

Pump housing

Bearing housing
HS range over view 2/4/6 pole motors Documentation
H Data Booklet Service Instructions
[m] HS
140 Vers ion 5 • Technical product descriptions • Description of service procedures
2-pole, 50 Hz
120 125- 100-305

• Product applications • Intended for service technicians


100

80
• Performance curves • Available in WebCAPS
65-50-242 100-80-242 125- 100-280 • Accessories
60
• Available in WebCAPS WebCAPS/WinCAPS
50

40
• Pump selection program
I&O • PDF literature files available
30
• Installation and operation • Service videos

20
• Warnings and safety requirements • Replacement pump information
• Targeted for installers, servicers, and end-users • Pump CAD drawings
14 • Shipped with the pump

10
20 25 30 40 50 60 80 100 150 200 250 300 400 500
Q [m�/h]

H
HS
important service & installation information
[m]
200 Vers ion 5
4-pole, 50 Hz
150

350-250-630
100
80
200-150-483 200-150-508
35
0-2
5 0-4
60 98
300-200-489
50

10 Ways to Kill Your HS Pump


1 50-1
2 5-38
1
40 30
0-
25
0-3
100-80-356 125-100-381 200-150-381 8 1
30 250-200-381
65-50-331 200-150-305A
25

1. Overwork it 7. Break its limbs


20
20 125-100-305 0-
15
0-
3 05

Work the pump continuously at higher capacities, flows, heads, Impose heavy piping loads on the suction and
C
15
65-50-242 100-80-242 300-250-305

400-350-397 or speeds than originally specified. discharge nozzle, either through initial
10

8
misalignment or through thermal expansion.
2. Starve it
150-125-305 250-200-305

6
5 Never grease or oil the pump. 8. Shake it
125-100-280
4 Don’t align at installation or install on a flimsy
20 30 40 50 60 80 100 150 200 300 400 500 600 800 1000 1500 2000 3000
Q [m�/h] 3. Choke it foundation.
• Lower the water level in the sump.
H
[m] HS • Let the suction strainer clog and never clean it. 9. Drown it
70 Vers ion 5 • Let the temperature of fluid rise without raising For a packed pump with a drain for the gland leakage:
60 6-pole, 50 Hz
the suction pressure. • Plug the drain with a cigarette butt, gum or paper.
50
350-250-630
• Remove the water shield.
40 200-150-508
4. Fry it • Line up the splits on the packing rings.
30 Operate at shutoff for a long time with the bypass line closed
200-150-483 300-200-489 350-250-498
tight will convert your power to heat. 10. Neglect check-ups
20
• Ignore the manufacturer’s recommendations for
350-300-508 5. Poison it “check-ups”
15 Change the pumped fluid without checking with the manufac- • Don’t check packing, gaskets, o-rings, or
250-200-381 300-250-381 400-350-397
turer (for example adding chemicals). other small parts.
10 • Don’t ever repaint it, or lubricate the coupling,
8 6. Stab it if required.
7
300-250-305
Remove the suction strainers which will introduce grit, sand, and • Don’t check vibration.
6
scale into the fluid.
5

4
60 80 100 150 200 300 400 500 600 800 1000 1500 2000 2500
Q [m�/h]
Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

PN 97718637

For product requests, please contact:


GMH2-CSU@Grundfos.com

Grundfos A/S
Poul Due Jensens Vej 7
DK-8850 Bjerringbro
Tel: +45 87 50 14 00
www.grundfos.com/industry
The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks
owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

You might also like