3rd Stage

Original 100 WNGL


Input Design Relief Case required
Mw 59.01 42.74 42.74
Displace (ft³/min) 804.50 804.50 804.50
Clearance vol/Piston Vol 19.80 19.80 19.80
Valve Losses % 4.00 4.00 4.00
k,cp/cv 1.082 1.123 1.123
Zsuction 0.973 0.978 0.978
Psuction 19.50 30.00 25.80
Tsuction,°F 138.00 143.00 143.00
Pdischarge, psia 66.40 75.00 75.00
Tdisch,°F (estimated) 200.00 200.00 200.00
Zdischarge 0.938 0.960 0.960
Iso,eff 0.750 0.750 0.750
Area Piston , in² 153.94 153.94 153.94
Area Rod, in² 3.14 3.14 3.14
Output
Density, suction lb/ft³ 0.184 0.203 0.174
Ts,°R 597.70 602.70 602.70
W,Lb/min 72.19 110.32 85.10
W, Lb/Hr 4331.18 6619.15 5105.97
r (Pd/Ps) 3.405 2.500 2.907
VE 48.66 67.66 60.68
ACFM 391.47 544.28 488.21
MMSCFD 0.67 1.41 1.09
Head 19198.76 20345.25 23893.61
Gas Horsepower 56.00 90.69 82.15
Tdisch, Pred °F 215.55 227.58 242.33
Load in Compression 7281.05 7021.55 7654.90
Load in Tension 7011.18 6691.68 7338.23