Calculated the Transfer Function for the Sallen-Key Low-pass filter, displayed on graphs, showing Bode
diagram, Nyquist diagram, Impulse response and Step response
Vin(s)→ →Vout(s)
Transfer Function:
11513309.38565
G(s)=
s2+4816.0173160173s+11513309.38565
fc= 550 Hz
R1 = 56kΩ Q factor | Damping ratio ζ
R2 = 33kΩ
C1 = 0.01uF Quality factor Q = 0.707
C2 = 0.0047uF
Damping ratio ζ = 1
Cut-off frequency
fc = 540.03290052424[Hz] C1 = F C2 = F
C1, C2 is optional. But when setting these
capacitances, C1 and C2 of both are needed to give
Quality factor following the equation
Q = 0.70455037083908 (C2/C1) ≤ ζ 2
(C1/C2) ≥ 4Q2
Calculate
Final value of the step response (on the
condition that the system converged when t
goes to infinity)
g(∞) = 1