PANEL DATA
AVAILABLE LENGTHS
Standard lengths 1.8 to 12metres. 12 to 16.0
metres can be supplied but are subject to
additional transport surcharge.
Internal Face
Page 1 of 5
Product Data Sheet
Page 2 of 5
Product Data Sheet
QUALITY
Benchmark Panels are manufactured from the
highest quality materials, using state of the art
production equipment to rigorous quality control
standards, approved to ISO 9001:2000 standard.
Kingspan manufacturing plants are ISO 14001
(Environmentally) and ISO 18001 (Health &
Safety) accredited.
PACKING
Standard Packing
The Wall Liner panels are stacked horizontally
with facing sheets upward. The top and bottom,
sides and ends are protected with polystyrene
and timber packing and the entire pack is
wrapped in polythene. The number of panels in
each pack depends on panel length, weight and
thickness. Typical pack height is 1100mm.
Maximum pack weight is 1500kg.
DELIVERY
All deliveries (unless indicated otherwise) are by
road transport to project site. Off- loading is the
responsibility of the client.
Page 3 of 5
Product Data Sheet
STRUCTURAL
Unfactored load/span table (use calculated design wind load values unfactored).
Page 4 of 5
Product Data Sheet
Structural Notes:
1. Values have been calculated using the limit state 5. For intermediate values linear interpolation may be
method described in the “European used.
Recommendations for the Design of Sandwich Panels”
(ECCS document No.115 2001), taking imposed loads, 6. The actual wind suction load resisted by the panel is
temperature and creep into account. dependent on the number of fasteners used and the
material of the purlin. The fastener calculation should
2. For each value individual and combined load cases be carried out in accordance with the appropriate
with appropriate load factors and temperatures have standard. For further advice please contact
been considered. Benchmark Technical Services.
3. The load tables are for dark coloured panels. 7. The allowable steelwork tolerance between bearing
planes of adjacent purlins is L/600. Where L is distance
4. The following deflection limits have been used: between supports.
Pressure loading L/200
Suction loading L/150
Page 5 of 5