You are on page 1of 15
z ART ROT Govt. of India ‘Saba ote Prater feat Central Public Works Department ‘Prater wert ag feet Nirman Bhawan, New Delhi ‘StH Hoos /07 Reale 05-11-2014 [Prater sa, ag Peco SUB: Revision of plinth area rates- 2012. ‘A meeting was held in the chamber of ADG (TD) to review the format of Plinth Area Rates-2012 and to finalize the standards/specifications. Please find enclosed the specifications of the buildings as per the proposed groupings for your comments. You are requested to furnish comments at the earliest please. Enels: As above (14 pages) No. 62/SE(TASYPAR/2014/ 2,5 3 - = Dt. 05/11/2014 To:- All the SDGs/ADGs/CEs of CPWD & PWD, Delhi (GNCT) through CPWD website. o SUPERINTENI ENGINEER(TAS) Specifications for Hospitals & MI Room (Group 1) [SNO- [SPACE] FLOORS WALLS CELING DOORS WINDOW T Entrance? | Granite/Witriied wes | Walls to be weated | 600x600mm | Frames: Frames: Lobby Hall with 6 mm thick POP | calcium 2nd class teak wood / | 2nd class teak punning (one time | sijcate/eypsum | UPVC exiruded frame | wood’ UPVC onl) and pied vi) SMe | setons with wall | exe fame low VOC Plastic f Leiba pass, ceiling with | thickness minimum | seetions with wall slide & ult 2.0mm / powder coated | thickness minimum arrangement | or anodized aluminum | 2.0mm powder extruded / tubular | coated or anodized section / Engineered | aluminum extruded ‘wood section tubular section! Shutter: Engineered wood 35mm thick factory | seetion alongwith made hardwood framed | the provision of sub paneled shutter with frame of suitable decorative pre-laminated | material. particle board paneling on bth sides. OR Shutters: Double 35mm th, pre. | shutter one with laminated with 2%lass teakwood decorative veneer on | framed glazed hoth sides flush door | panel and other shutter with melamine | with — wire-mesh polish OR shutter Glazed paneled shutter Or with $.$ mm thick float | UPVC extruded lass panes and | section of wall finished in melamine | thickness minimam polish. 2.0mm framed slazed / pancled shutters 2 | Comidors | Granite/Vititied les [ 12 mt Tiles with erash | -Do- Frames in Aluminium Darsiers & Flat oll paint shutters t be in glass oF above. Prelaminated boards as/ consultant choice. 3 "Tomaich corridor | -simeas corridor 7 Viwified ‘Acrylic paint “GOX600 mam = De calcium silicate/eypsum Metallic ceiling 3 ‘OPD Vitrified tiles Toiniiess Ceramic Tiles | 600x600 mm | Doors in Aluminium upto 12 mt. above 6001200 mm | Shuters to be in lass of Acrilye/ OBD with Crash | antibacterial | Pre- laminated boards as / Barriers. Tite ceiling | consultants choice wherever false ceiling provided over grid ceiling © | Diagnostic | Vitrified ‘Ani bacterial paint 00x60 ms calcium silicate/gypsum tiles, 7 | Tab vitfied | Granite’ Counter of | Glaved tiles upto 2-1mt & | 600x600 mm or | ATuminium frame shutters Corean anti haeteral paint in glass or Prelam boards {600% 1200 mam ‘anil bacterial [as per consultants choice tiles, efor Seif Levelling Fpoxy | with anti bacterial paint, | Seamless Tiermetcally sealed doors Flooring / anti or modular OT {600x6600 mm oF ‘bacterial viny floors {6001200 mm. ‘anti bacterial tiles 7 [aD Koia counters Green| do- ‘soN6OO TAM | ~do= Marble / Granite calcium silieate/eypsum ies Metalic ceiling TO | Ware Graniie7 Virified | Tointless CeramicT ‘SOONG mam | Frames ia Aluminiam [Non slippery tiles not | vitrified Tile upto Bed | calcium siicate | shutters to be in glass or less than 600x600 | head Panel. tilesfgypsum | pre- laminated boards as / ties. consultant design TT [ICUTCCU | Anti bacterial vinyl | Granite upto bed head | Seamiess7 “Aluminium Frame shutters flooring panel above Antbacterial | 600x600 mm or | in glass or Pre-lam boards sealing joint Epoxy / Paint. 60051200 mm | as /consultants choice antibacterial tiles 2 | Sore Kota] Terraza “ORD” “OBD- don 13 | Toile “Granite Vieifed | Tiles upto 2.Tet or Falss | 600x600 mam | PVC Doors Rajshri make \Non slippery ceiling where applicable | caleium ‘or Equivalent as per DSR silicatelgypsum | of CPWD. tiles 14 | Kitchen | ~do- “OBD- Frames in Aluminium shutters to bein glass oF pre: laminated boards as / ‘consultant design 13 | Laundry [do =o “OBD- ie 16 | Cafeteria | Viwitied double Board pancling/ Vitrified | 600x600 mm — | ~do- charged tiles. tiles upto eill ht caleium silicae/gypsum tiles Metallic ceiling 17 | Mortuary | Kou Tiles upto calling -OBD- Frames in Aluminium shutters 0 bein pre laminated boards as / ‘consultant design. Te] Sonics | Service Bldgs Extracted Conerste ‘OBD Bldgs 19 | Internal partion wall AAC Masonary partitions Cellular Conereie Bloek(CLC)’ Brick work! Fiy-ash brick 20 | Extemal finish of approved shade / premium Acrylic smooth water proof exterior finish/ stone work GRCT Designer Cement Concrete tile cladding in combination with structural glazing BI | Staircase railing shall be of stainless steel with glass /or any other material as per the design approved by the Architect may be provided.

You might also like