You are on page 1of 62
(Glasllg umall aS pb SS Bp le - 5 ale lay AL-HOUSSAIN & AL-AFALIG CO. Ready Mix Concrete - Blocks - Aggregate Ref No. HACO/QC/CMD-298 Rev.01 Larsen & Toubro ATCO Saudi L. Kingdom of Saudi Arabia Tel. No. Fax No. Mr. M.K. Sankar QW/0C Manager SUBJ: CONCRETE MIX DESIGN Project Title : Polyethylene LSPB Project-Jubail Contract No. Location Jubail Dear Sir, Reference to above subject, we are pleased to submit our proposed concrete mix design for your review and approval, as follows 14 Mpa Type I Cement We shall supply this concrete mix from our Jubal Batch Plant ‘Thank you for trusting us and hope you will find the documents acceptable. 9. -C.R, 2252000557 oT Ga ‘Capita 45,000,000 (966) 038977711 - S865006 (orn (966) 03 5850473, vewmchacaresdimni com ase et AL-HOUSSAIN & AL-AFALIQ CO. READY MIX CONCRETE, BLOCKS AND AGGREGATE ce TIRCOTOCIMD-258 Rev. 07 lass Project Polyethylene LSPS Project-Jubaiil Date : September 8, 2012 Contractor Larsen & Toubro Atco Saudi LLG. [Specified Sirengih a Mpa ment Brand Eastern Province Cement Co. [Feuling Time - imp Used YES [Max Temp Range °C 30 Tnitil Setting Tine (rir) 720 [Cement Type 7 Fossibly Sulphate Attack = [Structure Type - Design Requirements Sub [Stampin 725125 [Water Cement Ratio (Wax) 050 IW oF Cement (ka7ny 80 Maximum Size of Agaregate IW of Water (ka/m") 138, [Maximum Size (rm) 7% [Compressive Strenght © 28 Days (mpa) 14 [Nominal Max. Size (min) = [Eniropped Air (7) 7 7A Min. Bar Spacing (mA) = 175 Win. Bim. OF Members (rn) = Design Mix by Volume (per m? of concrete) [374 Min Cover) = 7 [Absolute Volume of Cement 0.088) [Absolute Volume of Microsilica Fume (W)| 0.000 Test on Water [Absolute Volume of Water 0.738, Rloride content (ZY WSOPE 7 [Absolute Volume of Admixtares OOF sulphate content (2) pom 3 [Volume oF Entrapped Air 0.020) [Absolute Volume of (Ie23-45) 0.250. Admixtures Saudi MET salute Volume of Fine Aggregate O250—| [Brand Name TO257RHSSI | B [Absolute Volume of Coarse Aggregate 0.750. [Dosage L/100K9 Cement ed EGE @ [Forel Absolute Volume 00 Specific Gravity 773071 276 Weight kg/m TTOTES, Uncorrected Weight (kgim* of concrete) Volume Term” —T 10035 (Cement 280 Mierosilica Fume 0 Stamp Cylinder Strength (pa) Water 138 ram 7 days 28 days: Admintures 42 745. 75.45 82 (Coorse Aggregate Te Fine Agoregate 737 Total Weight 2585 Corrected Weight (kg/m) [Remar (Cement Aggregate Source: ALOsals Crusher Abuhadryah erosive Fane Water [admixtures 1) Retarder (O25) 7.) Superplasticizer (RHBSTI) (Combined Coarse Aggregcte Prepared by 37a" Weight a 37a" Weight 356 (Combined Fine Aggregate 3/16" Weight o Noted By ‘Send Weight 731 Toral Weight 7385 LUmtas Lbiny Co, CR 2252000858, iad Copal 4,000,000, Tot No 035877-711/03-5005.008, Feo, 0-5050473, PO Bot 200 Holi ALA 21982 KSA Ea “inbo@hacoreadyix com Doe. Ret No RBICD, Rew, No/Dato" 0 (GUldellg (yuma aS pl (G2 SES - gle - 3a lS AL-HOUSSAIN & AL-AFALI CO. Ready Mix Concrete - Blocks - Aggregate Larsen & Toubro ATCO Saudi L.L.C. Kingdom of Saudi Arabia Tel. No. Fax No. ATTN: Mr. MLK. Sankar QA/OC Manager SUBJ: CONCRETE MIX DESIGN Project Title : Polyethylene LSPB Project-Jubail-I1 Contract No. Location Jubail Dear Sir, Reference to above subject, we are pleased to submit our proposed concrete mix design for your review and approval, as follows 20 Mpa Type I Screed Mix We shall supply this conerete mix from our Jubail Batch Plant ‘Thank you for trusting us and hope you will find the documents acceptable. nclvure {+366} 03 5877711 - 5868008 [96s) 03 5850473, ©.8ox:200 Al Ansa 21982. KSA Website : www hacoreadymi

You might also like