Product data sheet METSEPM5110 Characteristics PM5110 powermeter w modbus - upto 15th H - 1DO 33alarms - flush mount v Product or component. ‘ype Deviee short name puso Power meter ‘Sub feeder hn balldings Targa balding for ling (En- Market segment ergy cost management) ‘Main incomer in buildings / small building (Energy network management) Main incomer in buldings / medium building (Energ: y network managemen) ‘Sub feeder in bullaings/ large bulding (Energy net- work management) ‘Sub feeder in buildings /mult-ske (Energy network. management) ‘Sub feader in datacenter (Energy network manage- ment) ‘Sub feeder in heathcare (Energy network manage- ent ‘Sub feader in industry (Energy network manage ment) Main incomer in buildings! small uiling for- biling (Energy cost management) Sub feeder in buildings / small building for- biling (Energy cost management) Main Incomer in bulaings/ medium building for- biling (Energy cost management) ‘Sub feeder in bullings / medium building for biling (Energy cost management) Main incomer in buldings large bulding for biling (Energy cost management) Main Incomer in buildings ! muli-site for biting (En- ergy cost management) ‘Sub feeder in buildings / mult-ste for biling (Ener- gy cost management), ‘Main incomer in datacenter for bling (Energy cost- management) ‘Sub feader in datacenter fr bling (Energy cast- management) Main incomer in healthcare for biling (Energy cost management) ‘Sub feeder In heathcare for billing (Energy cost- management) Main incomer in industry for iling (Energy cost management) ‘Sub feeder in industry for iling (Energy cost man- agement) Main incomer in buldings/ small building for costal. location (Energy cost management) ‘Sub feeder in buildings / small building for cost alo- cation (Energy cost management) Main incomer in bulings/ medium bulding fr- cost allocation (Energy cost managernen!) Sib feeder in buildings / mecium bulding fr cost a location (Energy cost management) Main incomer in buldings large bulding fo cost a- location (Energy cost management) ‘Sub feader in buildings / large bulcing for cost allo cation (Energy cost management) Main incomer in buldings ! mu-site for cost alloca tion (Energy cost management) ‘Sub feoder in buildings /mult-site for cost aloca- tion (Energy cost managersent) Main incomer in datacenter for cost allocation (Ener- gy cost management) ‘Sub feader In datacenter for cost allocation (Energy cost management) Main incomer in healthcare for cost allcation (Ener gy cost management) ‘Sub foador in healthcare for cost allocation (Energy- cost management) Main incomer in industry for cost allocation (Energy: cost management) ‘Sub feeder in industry for cost allocation (Energy- cost management) ‘Sub feader in buildings / small building (Energy not- management ‘Sui feeder in ullings / medium bulding (Enerqy- network management) Complementary Power quality analyas Up othe Toh harmonic Devies aplication ‘Type of measurement Power montorng Energy ‘Active and reactive power Voltage Current Frequency Power factor Ts] rated supply voliage 700.,4T5 V AG (45..65 Ha) 125..250V DC Neiwark requensy 30 He 6oHe Taj rated caren TA 5A Poles descrnton TPN 3° SP +N Power consumpiion mn VA TOVA at 4150 Display ype Backit LOD Display resokion ‘Sampling rate 728 x 128 pals 64 samplesieyclo ‘Measurement curent 70.9000 mA ‘Analogue input ype Measurement voltage ‘Current (impedance 03 mOnm) Voltage (impedance 5 MOhm) 36,690 V AC 45,..65 Hz between phases 20.400 V AC 45.65 Hz between phase and neutral Frequency measurement range 4..05He Number of nous ° ‘Measurement accuracy 405 % acive energy 41-2 4 reactive energy 41.0.5 % active power +1-0.5 % apparent power $10.08 % frequency + 0.005 % power factor 4-05 % current 405 % vollage ‘Aesuracy dase Glass O55 (acve energy according to IFC 62055-22) Number af extpate T aigial “Communication por protacol Modbus RTU and ASCH 2 wives, 18.6, 182 and 384 Koauds, eventods- ‘or none, insulation: 2500 V seus ‘Communication por support RSa85 Data recording Mounting mode ‘MiniMax of instantaneous valves “Time stamping Flush-mounted ‘Mounting support Framework ‘Standards TEC 60528 Tec 61557-12 lec 6203-22 EN 50470-1 EN 60470-3, UL 1010-1 Tec 62083-24 Product carificatons CE conforming to IEC 6101041 (CULUS conforming to UL 1010-1 Wath 6m Depth Tamm Height 6mm Product weight 3808 Seprider

You might also like