Professional Documents
Culture Documents
Footing
Footing
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 2.029
Job Number 17128 Pw 13600 kN special member a 0 vr b 3.182
Footing Label F1 13666.32 Pf 17900 kN special member b 0 vr c 1.353
Allowable Bearing 5000 kPa footing d 1425 mm Beta 0.210 minimum 1.353
fc 30 Mpa dv 1282.5 mm Sigma 42 Vr1 1.353 Mpa
col a 600 mm qsr 591.736 kPa vc 0.75 kPa
col b 600 mm qa 449.587 kPa Vc 5,273.67 kN Vr two way 15615.556 KN
footing a 5500 mm Footing Vf a 3799.682 reduction 2426.486 KN
footing b 5500 mm a>b O/H a 2.45 percentage a 1.388 percentage 1.008
footing thickness 1500 mm O/H b 2.45 Vr one way b 5273.675
DEAD 10000 kN max O/H 2.45 Vf b 3799.682
LIVE 3600 kN min O/H 2.45 percentage b 1.388
bw 13800 aw min percent 1.388
CHECKS bo 8100 ao
AREA BETA 1 DEEP BEAM CALCULATIONS
Areq 2.720 m2 OK β 1 OH a/2d= 0.8596491 OH b/2d= 0.85964912
Aprovided 30.25 m2 2/(β+1) 1 Mfa(long way) 9,767,705 Mfb(short way) 9,767,705
FOOTING TYPE za 2.94 zb 2.94
SQUARE FOOTING As= 9771.6132 As= 9771.61319
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 1.7192982456 Not Deep Beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.7192982456 Not Deep Beam
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.870
Job Number 17128 Pw 1154 kN special member a 0 vr b 2.238
Footing Label F1 13666.32 Pf 1488 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.870
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.870 Mpa
col a 1400 mm qsr 375.758 kPa vc 0.75 kPa
col b 200 mm qa 291.414 kPa Vc 756.99 kN Vr two way 3098.325 KN
footing a 2200 mm Footing Vf a 1.000 reduction 627.750 KN
footing b 1800 mm a>b O/H a 0.4 percentage a 756.987 percentage 2.504
footing thickness 700 mm O/H b 0.8 Vr one way b 925.206
DEAD 972 kN max O/H 0.8 Vf b 196.333
LIVE 182 kN min O/H 0.4 percentage b 4.712
bw 8200 aw min percent 4.712
CHECKS bo 5700 ao
AREA BETA 7 DEEP BEAM CALCULATIONS
Areq 2.308 m2 OK β 1.2222222222 OH a/2d= 0.32 OH b/2d= 0.64
Aprovided 3.96 m2 2/(β+1) 0.9 Mfa(long way) 54,109 Mfb(short way) 264,533
FOOTING TYPE za 0.48 zb 0.96
TWO WAY RECTANGULAR FOOTING As= 331.5508 As= 810.457516
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 0.64 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.28 Not Deep Beam
Footings F1 01/29/2019
2811 Dufferin 12010 Jablonsky, Ast and Partners
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.870
Job Number 17128 Pw 2170 kN special member a 0 vr b 2.238
Footing Label F2 13666.32 Pf 2803.75 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.870
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.870 Mpa
col a 1400 mm qsr 599.092 kPa vc 0.75 kPa
col b 200 mm qa 463.675 kPa Vc 756.99 kN Vr two way 3098.325 KN
footing a 2600 mm Footing Vf a 40.439 reduction 1000.858 KN
footing b 1800 mm a>b O/H a 0.6 percentage a 18.719 percentage 1.462
footing thickness 700 mm O/H b 0.8 Vr one way b 1093.425
DEAD 1805 kN max O/H 0.8 Vf b 369.939
LIVE 365 kN min O/H 0.6 percentage b 2.956
bw 8200 aw min percent 2.956
CHECKS bo 5700 ao
AREA BETA 7 DEEP BEAM CALCULATIONS
Areq 4.340 m2 OK β 1.4444444444 OH a/2d= 0.48 OH b/2d= 0.64
Aprovided 4.68 m2 2/(β+1) 0.8181818182 Mfa(long way) 194,106 Mfb(short way) 498,444
FOOTING TYPE za 0.72 zb 0.96
TWO WAY RECTANGULAR FOOTING As= 792.91572 As= 1527.09695
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 0.96 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.28 Not Deep Beam
Footings F2 01/29/2019
2811 Dufferin 12010 Jablonsky, Ast and Partners
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.902
Job Number 17128 Pw 2350 kN special member a 0 vr b 2.356
Footing Label F3 13666.32 Pf 3032 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.902
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.902 Mpa
col a 1200 mm qsr 623.868 kPa vc 0.75 kPa
col b 200 mm qa 483.539 kPa Vc 756.99 kN Vr two way 2987.598 KN
footing a 2700 mm Footing Vf a 210.556 reduction 939.312 KN
footing b 1800 mm a>b O/H a 0.75 percentage a 3.595 percentage 1.295
footing thickness 700 mm O/H b 0.8 Vr one way b 1135.480
DEAD 1972 kN max O/H 0.8 Vf b 400.056
LIVE 378 kN min O/H 0.75 percentage b 2.838
bw 7800 aw min percent 2.838
CHECKS bo 5300 ao
AREA BETA 6 DEEP BEAM CALCULATIONS
Areq 4.700 m2 OK β 1.5 OH a/2d= 0.6 OH b/2d= 0.64
Aprovided 4.86 m2 2/(β+1) 0.8 Mfa(long way) 315,833 Mfb(short way) 539,022
FOOTING TYPE za 0.9 zb 0.96
TWO WAY RECTANGULAR FOOTING As= 1032.1351 As= 1651.41612
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 1.2 Not Deep Beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.28 Not Deep Beam
Footings F3 01/29/2019
2811 Dufferin 12010 Jablonsky, Ast and Partners
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.902
Job Number 17128 Pw 1236 kN special member a 0 vr b 2.356
Footing Label F4 13666.32 Pf 1593 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.902
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.902 Mpa
col a 1200 mm qsr 402.273 kPa vc 0.75 kPa
col b 200 mm qa 312.121 kPa Vc 756.99 kN Vr two way 2987.598 KN
footing a 2200 mm Footing Vf a 1.000 reduction 605.672 KN
footing b 1800 mm a>b O/H a 0.5 percentage a 756.987 percentage 2.256
footing thickness 700 mm O/H b 0.8 Vr one way b 925.206
DEAD 1044 kN max O/H 0.8 Vf b 210.188
LIVE 192 kN min O/H 0.5 percentage b 4.402
bw 7800 aw min percent 4.402
CHECKS bo 5300 ao
AREA BETA 6 DEEP BEAM CALCULATIONS
Areq 2.472 m2 OK β 1.2222222222 OH a/2d= 0.4 OH b/2d= 0.64
Aprovided 3.96 m2 2/(β+1) 0.9 Mfa(long way) 90,511 Mfb(short way) 283,200
FOOTING TYPE za 0.6 zb 0.96
TWO WAY RECTANGULAR FOOTING As= 443.68316 As= 867.647059
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 0.8 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.28 Not Deep Beam
Footings F4 01/29/2019
2811 Dufferin 12010 Jablonsky, Ast and Partners
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 2.029
Job Number 17128 Pw 890 kN special member a 0 vr b 2.493
Footing Label F4 13666.32 Pf 1148 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 1.353
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 1.353 Mpa
col a 600 mm qsr 585.714 kPa vc 0.75 kPa
col b 600 mm qa 454.082 kPa Vc 588.77 kN Vr two way 4143.179 KN
footing a 1400 mm Footing Vf a 1.000 reduction 878.938 KN
footing b 1400 mm a>b O/H a 0.4 percentage a 588.768 percentage 4.375
footing thickness 700 mm O/H b 0.4 Vr one way b 588.768
DEAD 748 kN max O/H 0.4 Vf b 1.000
LIVE 142 kN min O/H 0.4 percentage b 588.768
bw 7400 aw min percent 588.768
CHECKS bo 4900 ao
AREA BETA 1 DEEP BEAM CALCULATIONS
Areq 1.780 m2 OK β 1 OH a/2d= 0.32 OH b/2d= 0.32
Aprovided 1.96 m2 2/(β+1) 1 Mfa(long way) 65,600 Mfb(short way) 65,600
FOOTING TYPE za 0.48 zb 0.48
SQUARE FOOTING As= 401.96078 As= 401.960784
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 0.64 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 0.64 Deep beam
Footings F5 01/29/2019
2811 Dufferin 12010 Jablonsky, Ast and Partners
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.847
Job Number 17128 Pw 2624 kN special member a 0 vr b 2.140
Footing Label F4 13666.32 Pf 3383.25 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.847
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.847 Mpa
col a 1590 mm qsr 626.528 kPa vc 0.75 kPa
col b 200 mm qa 485.926 kPa Vc 756.99 kN Vr two way 3217.119 KN
footing a 3000 mm Footing Vf a 160.704 reduction 1144.901 KN
footing b 1800 mm a>b O/H a 0.705 percentage a 4.710 percentage 1.289
footing thickness 700 mm O/H b 0.8 Vr one way b 1261.645
DEAD 2211 kN max O/H 0.8 Vf b 446.401
LIVE 413 kN min O/H 0.705 percentage b 2.826
bw 8580 aw min percent 2.826
CHECKS bo 6080 ao
AREA BETA 7.95 DEEP BEAM CALCULATIONS
Areq 5.248 m2 OK β 1.6666666667 OH a/2d= 0.564 OH b/2d= 0.64
Aprovided 5.4 m2 2/(β+1) 0.75 Mfa(long way) 280,260 Mfb(short way) 601,467
FOOTING TYPE za 0.846 zb 0.96
TWO WAY RECTANGULAR FOOTING As= 974.34283 As= 1842.72876
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 1.128 Not Deep Beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.28 Not Deep Beam
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.751
Job Number 17128 Pw 2366 kN special member a 0 vr b 1.553
Footing Label F4 13666.32 Pf 3048 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.751
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.751 Mpa
col a 3625 mm qsr 586.154 kPa vc 0.75 kPa
col b 200 mm qa 455.000 kPa Vc 546.71 kN Vr two way 4764.656 KN
footing a 4000 mm Footing Vf a 1.000 reduction 2055.202 KN
footing b 1300 mm a>b O/H a 0.1875 percentage a 546.713 percentage 2.237
footing thickness 700 mm O/H b 0.55 Vr one way b 1682.193
DEAD 2004 kN max O/H 0.55 Vf b 1.000
LIVE 362 kN min O/H 0.1875 percentage b 1682.193
bw 12650 aw min percent 546.713
CHECKS bo 10150 ao
AREA BETA 18.125 DEEP BEAM CALCULATIONS
Areq 4.732 m2 OK β 3.0769230769 OH a/2d= 0.15 OH b/2d= 0.44
Aprovided 5.2 m2 2/(β+1) 0.4905660377 Mfa(long way) 13,395 Mfb(short way) 354,623
FOOTING TYPE za 0.225 zb 0.66
ONE WAY FOOTING As= 175.09191 As= 1580.31674
ONE WAY SHEAR OK
TWO WAY SHEAR NOT APPLICABLE DEEP BEAM IN FOOTING LONG DIRECTION? 0.3 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 0.88 Deep beam
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 1.691
Job Number 17128 Pw 1966 kN special member a 0 vr b 2.356
Footing Label F4 13666.32 Pf 2528 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 1.353
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 1.353 Mpa
col a 800 mm qsr 632.000 kPa vc 0.75 kPa
col b 600 mm qa 491.500 kPa Vc 841.10 kN Vr two way 4481.398 KN
footing a 2000 mm Footing Vf a 47.400 reduction 1103.235 KN
footing b 2000 mm a>b O/H a 0.6 percentage a 17.745 percentage 2.209
footing thickness 700 mm O/H b 0.7 Vr one way b 841.096
DEAD 1684 kN max O/H 0.7 Vf b 173.800
LIVE 282 kN min O/H 0.6 percentage b 4.839
bw 7800 aw min percent 4.839
CHECKS bo 5300 ao
AREA BETA 1.3333333333 DEEP BEAM CALCULATIONS
Areq 3.932 m2 OK β 1 OH a/2d= 0.48 OH b/2d= 0.56
Aprovided 4 m2 2/(β+1) 1 Mfa(long way) 227,520 Mfb(short way) 309,680
FOOTING TYPE za 0.72 zb 0.84
SQUARE FOOTING As= 929.41176 As= 1084.31373
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 0.96 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 1.12 Not Deep Beam
Footings F6 01/29/2019
2811 Dufferin 12010 Jablonsky, Ast and Partners
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.758
Job Number 17128 Pw 1966 kN special member a 0 vr b 1.613
Footing Label F4 13666.32 Pf 2528 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.758
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.758 Mpa
col a 3300 mm qsr 638.384 kPa vc 0.75 kPa
col b 200 mm qa 496.465 kPa Vc 504.66 kN Vr two way 4503.177 KN
footing a 3300 mm Footing Vf a 1.000 reduction 2067.167 KN
footing b 1200 mm a>b O/H a 0 percentage a 504.658 percentage 2.599
footing thickness 700 mm O/H b 0.5 Vr one way b 1387.809
DEAD 1684 kN max O/H 0.5 Vf b 1.000
LIVE 282 kN min O/H 0 percentage b 1387.809
bw 12000 aw min percent 504.658
CHECKS bo 9500 ao
AREA BETA 16.5 DEEP BEAM CALCULATIONS
Areq 3.932 m2 OK β 2.75 OH a/2d= 0 OH b/2d= 0.4
Aprovided 3.96 m2 2/(β+1) 0.5333333333 Mfa(long way) 0 Mfb(short way) 263,333
FOOTING TYPE za 0 zb 0.6
ONE WAY FOOTING As= #DIV/0! As= 1290.84967
ONE WAY SHEAR OK
TWO WAY SHEAR NOT APPLICABLE DEEP BEAM IN FOOTING LONG DIRECTION? 0 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 0.8 Deep beam
INPUTS INTERNAL CALCULATIONS ONE WAY SHEAR CALCULATIONS TWO WAY SHEAR CALCULATIONS
Job Name 258 Sunview Bld. 1 one way shear vr a 0.902
Job Number 17128 Pw 1236 kN special member a 0 vr b 2.356
Footing Label F4 13666.32 Pf 1593 kN special member b 0 vr c 1.353
Allowable Bearing 500 kPa footing d 625 mm Beta 0.210 minimum 0.902
fc 30 Mpa dv 562.5 mm Sigma 42 Vr1 0.902 Mpa
col a 1200 mm qsr 603.409 kPa vc 0.75 kPa
col b 200 mm qa 468.182 kPa Vc 504.66 kN Vr two way 2987.598 KN
footing a 2200 mm Footing Vf a 1.000 reduction 908.508 KN
footing b 1200 mm a>b O/H a 0.5 percentage a 504.658 percentage 2.446
footing thickness 700 mm O/H b 0.5 Vr one way b 925.206
DEAD 1044 kN max O/H 0.5 Vf b 1.000
LIVE 192 kN min O/H 0.5 percentage b 925.206
bw 7800 aw min percent 504.658
CHECKS bo 5300 ao
AREA BETA 6 DEEP BEAM CALCULATIONS
Areq 2.472 m2 OK β 1.8333333333 OH a/2d= 0.4 OH b/2d= 0.4
Aprovided 2.64 m2 2/(β+1) 0.7058823529 Mfa(long way) 90,511 Mfb(short way) 165,938
FOOTING TYPE za 0.6 zb 0.6
TWO WAY RECTANGULAR FOOTING As= 443.68316 As= 813.419118
ONE WAY SHEAR OK
TWO WAY SHEAR OK DEEP BEAM IN FOOTING LONG DIRECTION? 0.8 Deep beam
DEEP BEAM IN FOOTING SHORT DIRECTION? 0.8 Deep beam