OPTIONAL COOLING PACKAGE

Data Sheet

The values on this data sheet represent optional cooling package alternatives to the standard cooling packages
on our units. For data describing our standard products, please refer to individual spec sheets. Optional cooling
packages are only available for the units shown on this data sheet.

Model Power Ambient Total Fan Air Flow Maxi- Level Dimen- Dimen- Dimen-
Node Capacity: Coolant Power: Required mum 0: Open sions sions sions
°C (°F) Capacity: kW (hp) for Rad. Cooling Power Height: Length: Width:
L (gal) Cooled Air Flow Unit mm (in.) mm (in.) mm (in.)
Unit: Static Sound
m3/min* Restric- Level:
(SCFM) tion: kPa dB(A)
(in. H20)
Series 2000 Prime
MTU 12V2000 DS750 680 kW 50 294.7 38 1,132 0.125 C/F 2,222 4,395 1,759
(122) (77.8) (50.9) (39,976) (0.50) (87.5) (173) (69.25)
Series 2000 Standby
MTU 12V2000 DS750 750 kW 50 294.7 38 1,132 0.125 89.9 2,222 4,395 1,759
(122) (77.8) (50.9) (39,976) (0.50) (87.5) (173) (69.25)
Series 4000 Prime
MTU 12V4000 DS1500 1,400 kW 50 578.5 82.4 C/F 0.125 C/F 2,902 6,172 2,632
(122) (152.8) (110.5) (0.50) (114.25) (243) (103.63)
MTU 12V4000 DS1750 1,600 kW 50 578.5 76.2 2,027 0.125 C/F 2,902 6,172 2,632
(122) (152.8) (102.2) (71,579) (0.50) (114.25) (243) (103.63)
MTU 16V4000 DS2000 1,800 kW 50 717 105 3,089 0.125 94.7 3,353 6,655 2,921
(122) (189.4) (141) (109,079) (0.50) (132) (262) (115)
MTU 16V4000 DS2250 2,045 kW 50 717 105 3,089 0.125 94.7 3,353 6,751 2,921
(122) (189.4) (141) (109,079) (0.50) (132) (265) (115)
Series 4000 Standby
MTU 12V4000 DS1500 1,500 kW 50 578.5 82.4 C/F 0.125 C/F 2,902 6,172 2,632
(122) (152.8) (110.5) (0.50) (114.25) (243) (103.63)
MTU 12V4000 DS1750 1,750 kW 50 578.5 76.2 2,027 0.125 C/F 2,902 6,172 2,632
(122) (152.8) (102.2) (71,579) (0.50) (114.25) (243) (103.63)
MTU 16V4000 DS2000 2,000 kW 50 717 105 3,089 0.125 94.7 3,353 6,655 2,921
(122) (189.4) (141) (109,079) (0.50) (132) (262) (115)
MTU 16V4000 DS2250 2,250 kW 50 717 105 3,089 0.125 94.7 3,353 6,751 2,921
(122) (189.4) (141) (109,079) (0.50) (132) (265) (115)
MTU 16V4000 DS2500 2,500 kW 50 780 99.2 3,231 0.125 C/F 3,454 7,315 3,023
(122) (206) (133) (114,120) (0.50) (136) (288) (119)
MTU 20V4000 DS2800 2,800 kW 50 822.8 112.3 3,621 0.125 C/F 3,810 8,128 3,353
(122) (217.4) (150.6) (127,874) (0.50) (150) (320) (132)
MTU 20V4000 DS3000 3,000 kW 50 1,012.1 115 3,833 0.125 94.6 3,810 8,128 3,353
(122) (267.4) (154.2) (135,361) (0.50) (150) (320) (132)
MTU 20V4000 DS3250 3,250 kW 50 1,012.1 115 3,833 0.125 C/F 3,810 8,128 3,353
(122) (267.4) (154.2) (135,361) (0.50) (150) (320) (132)
*Air density = 1.184 kg/ m3 (0.0739 lbm/ft3)
C/F = Consult Factory / MTU Onsite Energy Distributor

// Page 1 of 2
OPTIONAL COOLING PACKAGE
Data Sheet

NOTES:
• Data is the result of laboratory tests with engines representing these ratings.
• Site installation variables such as temperature and altitude may impact cooling performance. For site speciÀc
data, refer to PS-SPEC at www.mtuonsiteenergy.com.
• All information is based on 25 °C at 100 m operating conditions.
• Consult your MTU Onsite Energy distributor for speciÀc generator set dimensions.

© MTU Onsite Energy. Subject to alteration due to technological advances. 2017-05