KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
Disclaimer
This document has been prepared on behalf of and for the exclusive use of OIL AND NATURAL
GAS CORPORATION LTD (ONGC), and is subject to and issued in accordance with the agreement
between ONGC and INTECSEA.
INTECSEA accepts no liability or responsibility whatsoever for it in respect of any use of or reliance
upon this report by any third party.
Copying this document without the permission of ONGC and INTECSEA is not permitted.
DOCUMENT TITLE: TECHNICAL BID ADDENDUM 002 FOR ONSHORE MEG & GAS
PIPELINE (OMF) TERMINAL UNDER KG DWN 98/2
DEVELOPMENT PROJECT
Page 2 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
Table of Contents
1 INTRODUCTION ................................................................................................................... 5
6 MALLAVARAM .................................................................................................................... 41
7 IOPS......................................................................................................................................... 50
Appendix List
Appendix 1 U Field Process Flow Diagrams (PFDs) .......................................................................................... 51
Appendix 2 Vashishta+U Field Heat & Mass Balance 10.5 & 7 MMSCMD Cases ............................... 52
Appendix 7 Full Flow Relief (10.05 MMSCMD) Flarenet Calculation Note .............................................. 59
Page 3 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
Appendix 21 Basic Engineering Design Basis Part A for Flare System ...................................................... 74
Page 4 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
1 INTRODUCTION
1.1 COMPANY informs Bidders that the earlier proposal to take the entire gas of
KG-DW-98/2 to Odalarevu through export pipeline from CPP stands revised
and it is now planned to export the gas from A-field, R-field and associated
gas from oil fields to Company’s Onshore Gas Terminal (OGT) at Mallavaram.
1.2 Company also intends to monetise the U-field gas through S1-VA existing
facilities and process at Odalarevu.
1.3 The related changes in the scope given in TBP of tender no K07DC16051
stands revised to the extent that facilities provided shall be optimised
between the two terminals as brought out below. With this re-routing of
export gas line, processed export gas from CPP will be received by OGT at
Mallavaram and the OMF will not receive any gas from CPP. Therefore
facilities planned at OMF to receive gas from CPP are now shifted from OMF
at Odalarevu to OGT at Mallavaram and are part of Bidder’s Scope. Note the
export gas flowrates to OGT at Mallavaram now exclude U Field gas.
1.4 S1-VA existing facilities are required to receive and process gas from U Field
and the remaining scope as per the tender remains unchanged. The scope of
work related to early monetisation of the U-field gas through S1-VA existing
facilities at Odalarevu is already given in Technical Bid Addendum 001 Rev 0E.
The details related to change in export pipeline route from CPP to OGT at
Mallavaram.
Page 5 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
ii. Revised operating philosophy for U Field production via Vashishta plant
(including a new OMF/Vashishta HP flare stack and new fuel gas supply).
iii. Revised operating philosophy for gas export from CPP to Mallavaram OGT
with revised gas export rate from CPP of 11.5 MMSCMD (9.5 MMSCMD from
Cluster 2 and 2 MMSCMD from Cluster 1).
COMPANY anticipates that all other aspects of the design will remain unaffected and thus
not impacted.
Page 6 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
3.1 Bidder shall refer to the Document Index included with this Bid Addendum
under item 3.2. These documents form a part of this Bid Addendum.
3.2 Bidder shall refer to the following documents when reading this Bid
Addendum 002:
Page 7 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
Page 8 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
4.3 The firewater at OMF shall be supplied with 2 x 50% electric motor driven
centrifugal pumps and 2 x 50% (standby) diesel engine driven centrifugal
pumps.
4.4 Instrumentation can be Field Bus based since S1-VA existing facilities at
Odalarevu and OGT at Mallavaram are already Field Bus based.
4.5 CPP gas export pressure is planned for 90 kscg and the tie-in pressure to
onshore transportation infrastructure is to be in the range of 59-61 kscg.
Parameter
75% Minimum
Methane
0
HC Dew Point * ( oC), max
0
Water Dew Point * ( oC), max
5
H2S PPM by weight , max
10
Total Sulphur PPM by weight , max
6
Carbon Dioxide (mole %), max
0.2
Oxygen (mole %), max
8
Total Inerts (mole %)
55
Temperature ( oC), max
Page 9 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
4.7 Bidder shall complete all safety studies (HAZOP, HAZID etc.) defined in
Section 4.27 of the Onshore MEG and Gas Pipeline Terminal Scope of Work,
402020-01391-08-PM-SOW-0001, for the Work associated with the Gas
receiving and custody transfer of gas at OGT, Mallavaram and OMF
Odalarevu. This shall include assessment of the impact on the existing facilities
and carrying out any remedial work, if required. The integrated facility should
have QRA certificate. Company will provide successful Bidder with current
QRA documentation for both Mallavaram OGT and OMF Odalarevu.
4.9 Scope associated with fire and gas detection, fire suppression and fire water
systems will be in the bidder’s scope along with all associated design
documents (e.g. fire water demand calculations, layouts, P&Ds, pump
datasheets, etc.).
Page 10 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
4.11 Bidders are advised of new HP Flare in OMF Odalarevu as part of existing
scope to handle total envisaged production of 98/2 project shall now be
designed to handle full flow relief capacity of 10.05 MMSCMD with 5.75
MMSCMD gas from U Field and 4.3 MMSCMD gas from Vashishta S1-VA
production rate . The OMF LP and LLP flare as required in original scope are to
be provided.
4.12 Bidder has to assess the impact of shifting of export pipeline on the functional
requirement of OMF and incorporate the changes as brought out but not
limited to the scope as below:
Bidder to revise the OMF fuel gas tie-in location from separator of 20” gas
export pipeline to U Field GDU gas outlet in S1 & VA terminal (alternate to be
agreed with Company during detailed engineering). The change in fuel gas &
GTG gas supply to OMF facilities is due to rerouting of 20” Export gas pipeline
from OMF Odalarevu to OGT Mallavaram.
Page 11 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
No. K07DC16051
Revision 0E
4.13 Bidder to assess and execute the scope related to impact on utilities system
and firewater system on OMF facilities.
4.14 Company is presently discharging the effluent from G1 & GS-15 terminal ETP
into existing onshore injection wells. This is now required to be tied into the
discharge line (downstream of OMF ETP), for discharge into the sea along with
discharge of 98/2 effluent from its ETP. Additional tie-in points of suitable size
with isolation valve are to be provided as part of the scope.
4.15 Bidder’s scope includes additional list of Laboratory equipment / items for
OMF in addition to the list of equipment to be provided as per original scope
already presented in Appendix-H of OMF Scope of Work (Doc No. 402020-
01391-08-PM-SOW-001). The additional list is attached as Appendix 11 in this
Addendum-002.
4.16 Onshore MEG associated Piping, Valves, Pumps and Strainers shall be of
stainless steel metallurgy. Onshore MEG tanks can be carbon steel with
internal epoxy lining.
4.17 If MEG licensor has indicated to ONGC that its standard scheme does not
include filtration of Lean MEG to subsea control quality requirements, then
2x100% filtration units shall be required and included in Bidders’ scope.
4.18 The following para of section 14.1 Training categories (page 130) of
Functional Specification for Integrated Operations Systems 402020-01391-08-
IS-FSP-0001 Revision 0D, to be modified as:
Page 12 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
5.3 Bidders are advised of a change in project schedule in that S1-VA wells are to
be in production by end February 2018. The U-Field wells first gas date is 17
months from NOA. However the OMF MEG plant is expected to be ready by
22 months from NOA, a gap of 5 months approximately from U-field first gas
date.
5.4 Emergency Response Plan (ERP) and Disaster Management Plan (DMP) For
Mallavaram Onshore Terminal and Odalarevu shall be updated with new
facilities and get it certified by statutory authorities. Existing plan will be
provided to Bidders by Company with clarity on what statutory authorities are
applicable.
5.5 Updated Operating Philosophy for U-Field and S1-VA Field wells
S1-VA wells are to be online by end February 2018. The U-Field wells expected
first gas date is December 2019. However, as soon as the first well of U Field is
drilled samples will be collected and analyzed for suitability of processing of
Rich MEG from U Field through S1VA MEG plant. Currently there is no
produced water from U-field wells for analysis.
Page 13 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
The OMF MEG plant is expected to be ready by June 2020, a gap of 6 months from
first gas from U-field.
For Rich MEG handling from U Field, the S1VA MEG regeneration package (ON-Z-
1801) will initially be used to process and regenerate the rich MEG. This will be for
up to 6 months before the MEG Plant at OMF becomes available. During this
period Company does not anticipate any formation water from U Field.
Once the OMF plant available, the total Rich MEG from U Field separators and
S1VA production (from the S1VA slug catcher) will be routed to OMF MEG facility
and S1VA MEG regeneration package shall be mothballed (to be performed by
others). This will marginally increase total rich MEG flowrates at OMF which are
now to include Vashishta rich MEG flowrates.
Lean MEG injection requirement to U-field wells for first 6 months initially at 80
wt % Lean MEG from S1VA plant will be injected to U Field wells using new U Field
Lean MEG injection pump and 2 x 1.25” ID Cores in the S1VA Umbilical. For the
rest of the field life 90 Wt% Lean MEG from OMF will be injected through 6” MEG
injection line for U Field wells.
A new Rich MEG transfer line will be required to transfer rich MEG from upstream
of the Vashishta MEG package ON-Z-1801 to the OMF MEG degasser (V-N79100).
A new Lean MEG transfer line will be required to transfer 90 wt % lean MEG from
the OMF Lean MEG Product Tanks (T-N79002 A/B) to the Vashishta Lean MEG
storage tank (ON-TK-1901). This will allow 90 wt% Lean MEG to be injected to
S1VA wells via their umbilical.
Page 14 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Chemical injection of scale inhibitor (SI) and corrosion inhibitor (CI) and methanol
to the U Field wells will continue to be injected via the S1VA umbilical throughout
the field life of S1VA and U Field wells. This will be facilitated by using the new U
Field SI and new CI injection pump packages (pumps+storage tank) and new U
Field methanol injection pump. Bidders should note that S1VA wells do not have
subsea methanol injection. However the methanol injection to U Field wells will be
via an existing 1.25” MEG core in the S1VA umbilical.
The U Field GDU will be operational for U Field first gas, operating under
segregated flow of 3.5 MMSCMD and at high pressure (63 barg) for approximately
3 years until 2022 i.e. U Field production via one 14” pipeline and S1VA production
via the other 14” production pipeline at low pressure. Note that total U Field
segregated flow is 5.75 MMSCMD and the excess U Field gas of 2.25 MMSCMD is
to be tied-in to the existing 24” future connection on the compressor discharge
header. When total flow reduces from 10.05 MMSCMD to 7 MMSCMD by 2022 the
U Field GDU and U Field separators will become redundant and S1VA facility will
continue to process at 7 MMSCMD which is its gas compression system capacity
limit.
Supplying the heating duty (0.4 to 0.5 MW) for the new U Field GDU reboiler from
the existing S1VA hot oil system should be possible since the S1VA hot oil system
will not be operating at full load initially. Because of the low initial Rich MEG
flowrates from U Field and S1VA wells (up to 2020) result in significantly reduced
MEG reclaimer duty requirements for the existing MEG Package in S1VA facility.
This heating arrangement for the U Field GDU should be adequate even after 2020
when the S1VA MEG package is mothballed (to be performed by others) and all its
heating duty becomes available to other users.
A new power generating unit for OMF is to be integrated into the existing S1VA
power generating system 6 months before OMF is fully operational. There is no
need for a new WHRU to be initially integrated with the new power generating
unit for OMF and the Vashishta hot oil system. Bidders to make provisions for the
WHRU to be installed with the rest of the OMF equipment and integrated with the
OMF hot oil heating system in order to optimise heating loads for the OMF.
Page 15 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
5.6 Initial Lean and Rich MEG rates for U-Field and S1-VA wells.
Based on the above operating philosophy initial Lean MEG injection rates and
Rich MEG production rates are presented in Table 1 for S1VA facility. Rich
MEG flowrate is conservatively calculated to be 4.37 m3/hr for processing at
Vashishta plant before OMF plant is available.
The combined Rich MEG rates at OMF are presented in Table 2. Peak rate is
calculated to be 48.6 m3/hr. Peak Rich MEG flowrate from Vashishta is
23.3m3/hr.
Once OMF is available 6 months after U Field first gas and the S1VA MEG unit
(ON-Z-1801) has been mothballed, the OMF will supply all the Lean MEG
requirements for Vashishta, U Field and R & A Fields (sum of Table 1 & 2
rates). However, only a peak rate 1.5m3/hr Lean MEG is required to be
injected to S1VA well.
5.8 Lean and Rich MEG transfer lines between OMF and Vashishta.
Bidder’s scope shall include piping connections with isolation valves for Rich
MEG transfer line from U Field separators and Vashishta Slugcatcher to OMF
MEG Degasser are to be provided for transfer of RICH MEG (23.3 m3/hr) from
Vashishta plant to OMF MEG Plant.
Bidder’s scope shall include inter connection between Lean MEG Storage
tanks of S1VA and OMF along with suitable transfer pumps to allow two way
transfer. The lean MEG transfer flowrate from OMF Lean MEG storage tank to
Vashishta Lean MEG storage tank to be 1.5 m3/hr based on the peak lean MEG
flowrate for S1 & Vashishta wells only. The Lean MEG Transfer Pumps (P-
N79009 A/B/C/D) at OMF will need to accommodate this additional flowrate
requirement.
Page 16 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline (OMF) Terminal
under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Table 1 - S1VA - Lean MEG injection rates and Rich MEG production rates
Page 17 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline (OMF) Terminal
under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Table 2 - OMF - Lean MEG injection rates and Rich MEG production rates
OMF Bidder shall make all necessary Tie-ins and piping connections.
Page 18 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Based on the latest operating philosophy for OMF/Vashishta as outlined in section 5.5
preliminary process data based on heat and mass balance is presented in the
following sections. Bidders shall verify all data presented in next phase of engineering
/ detailed design.
Relief and blowdown studies and flare sizing study are available and only referenced
in this document. The results of these studies are however summarised in this
addendum.
5.10 HIPPS
Common sparing of the HIPPS systems shall be provided once the U Field HP
Separators are mothballed. Bidder shall verify the required line/valve size for U field
production using the design requirements of Clause 3.7 of the Onshore MEG & Gas
Pipeline Terminal Design Basis, 402020-01391-08-PR-BOD-0001 Rev 0E to determine
the feasibility of this approach.
Page 19 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Notes:
a. Valve closure time to be confirmed by Bidders in detailed design with dynamic
simulations.
b. HIPPS valve to have metal seating
c. End connections of the HIPPS valve shall be welded.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
Notes:
a. 20 m3 slug volume is considered per separator based on initial flow assurance
studies with 25% margin. This slug volume should be confirmed by Flow
Assurance studies in Detailed Design since it governs the U Field separator sizing.
Page 20 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
c. Gas metering on the separators gas outlets is required to monitor U Field gas
production.
e. Skid design of separators may be considered for future re-use since currently
operational requirements are only for four years 2020 to 2023 when total
production (U Field + S1VA) production is 10.05 MMSCMD and segregated flow
between U Field and SV1A production applies.
f. Two phase separator considered (gas & aqueous phases) since no hydrocarbon
liquids expected from U Field production based on 100% U Field gas composition
components.
g. Feed Inlet Nozzle / Gas Outlet Nozzle are calculated to be 16” and 12”
respectively. Bidders to confirm.
i. U-field Separator outlet to have provision for connecting to inlet manifold of gas
Compressor. This is required for individual well testing in future.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering. Existing Fresh Glycol storage tank (ON-TK-1401) and Fresh
Glycol Transfer Pumps (ON-P-1403 A/B) will be used by COMPANY for filling-up and
make-up of the new GDU and no new tank and pump for this purpose is envisaged.
Page 21 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
U Field GDU can be located adjacent to existing GDU package (ON-Z-1401) or located
at the designated area for future GDU.
Total loss of glycol shall not exceed standard values of 13 litres / MMSCM (Glycol
absorber, Rich Glycol Flash drum, and Glycol Still Column – (HOLD).
Page 22 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Page 23 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Available Utilities at S1VA facility at normal operating conditions are listed below.
Vendor shall state all utility requirements and consumptions including additional
utilities if any.
24
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Vendor shall state expected sound pressure levels generated by the system. Maximum
noise level at working places shall be in accordance with OSHA or local regulatory
guidelines whichever is the more stringent.
Note 1: Bidders to note hot oil for TEG reboiler duty for the new U Field Gas
Dehydration Unit (GDU) is to be supplied by the Vashishta plant hot oil system (500
kW estimated)
Vendor shall supply a complete gas dehydration package suitable for continuous
operation in outdoor environment. In general the vendor shall be responsible but not
limited to the following:
Skid design of GDU package may be considered for future re-use since currently
operational requirements are only for four years 2020 to 2023 when total
production (U Field + S1VA) production is 10.05 MMSCMD and segregated flow
between U Field and SV1A production applies. Provision to connect GDU outlet to
inlet of existing DPDU with an isolation valve shall be in bidders scope.
25
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Line List
Utility Summary
Chemicals consumption summary and initial fill
Flare load summary
Process simulations, Design calculations for GDU equipment sizing
Blowdown calculations
Operating manuals covering normal, start-up/shutdown, emergency procedures
Equipment layout
Inclusion / Exclusions as part of package supply.
Deviations list if any.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
No. of Pumps 2x100% Pumps (one operating with one standby A/B)
Fluid 80 wt. % Lean MEG
Capacity 2 m3/hr (Yr. 2019 – 2020)
Discharge Pressure 225 Bara (Flow Assurance to confirm in Detailed Design)
Storage Requirements < 250 m3 (Flow Assurance to confirm in Detailed Design)
Notes:
a) Storage requirements to take into account starvation period during U Field
turndown and restarts. Current MEG storage tank capacity for ON-TK-1901 with
229m3 working capacity and 307m3 design capacity. Flow assurance report
indicates a volume of 250 m3 would be required based on a higher WGR of 2
bbl/MMscf for U Field gas production. Flow Assurance to confirm storage volume
required at S1VA (before OMF becomes available) during detailed design.
b) U Field Lean MEG injection pump to inject into 2x1.25” MEG cores in the S1VA
chemical TUTU.
c) U Field Lean MEG injection pump requirements at Vashishta plant are potentially
for the period of first gas from U Field to when the OMF becomes available. It
could be six months before these requirements are transferred to the OMF and U
26
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Field Lean MEG injection pump becomes redundant. Re-use of these pumps
should therefore be considered as part of their selection.
d) U Field Lean MEG injection pump capacity of 2 m3/hr is significantly higher than
current capacity of 0.7m3/hr and injection pressure of 233 Bara thus a similar
pump (common sparing, maintenance etc.) cannot be used for this duty.
e) Lean MEG transfer line will be required to transfer Lean MEG (90 wt.%) from OMF
Lean MEG storage tanks (T-N79002 A/B) to S1VA Lean MEG storage tank (ON-TK-
1901) once OMF plant becomes available and S1VA MEG unit is mothballed.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
No. of Pumps 2x100% Pumps (one operating with one standby A/B)
Fluid Methanol
Capacity 2 m3/hr (well start-up in 1 hour)
Discharge Pressure 277 Bara (Flow Assurance to confirm in Detailed Design)
Storage Requirements 22m3 (Flow Assurance to confirm in Detailed Design)
Notes:
a) Storage requirement based on two full field start-ups following a long term
shutdown is 50 m3. Current Methanol storage tank capacity for ON-TK-1904 is 50
m3 working capacity and 87m3 design capacity. Full field start-ups refer to starting
up all four U Field wells sequentially.
b) New U Field Methanol injection pump to inject into 1x1.25” MEG (current
designation) core in the S1VA chemical TUTU since methanol is not currently
injected subsea to the S1VA wells via the umbilical.
c) New pump capacity is significantly higher than current pump (ON-P-1904 A/B)
capacity of 0.3m3/ hr with discharge pressure of 67 barg, thus a similar pump
(common sparing, maintenance etc.) cannot be used for this duty.
27
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
No. of Pumps 2x100% Pumps (one operating with one standby A/B)
Fluid Corrosion Inhibitor
Capacity 55 litres/hr (200 ppmv x 20 of base concentration)
Discharge Pressure 155 bara (Flow Assurance to confirm in Detailed Design)
Storage Requirements 9.2m3 for 7 days or 39.3m3 based on 30 days.
(Flow Assurance to confirm in Detailed Design)
Notes:
a) CI storage tank capacity for ON-TK-1902 is 200 litres based on 7 days storage of
1m3 or for a period of 30days whichever is higher.
b) New U Field CI injection pumps to inject into 2x0.5” CI cores in the S1VA chemical
TUTU.
c) New pump capacity is significantly higher than current capacity of 0.8 litres/hr at
38 Bara.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
No. of Pumps 2x100% Pumps (one operating with one standby A/B)
Fluid Scale Inhibitor
Capacity 9.6 litres/hr (35 ppmv x 20 of base concentration)
Discharge Pressure 88 Bara (Flow Assurance to confirm in Detailed Design)
Storage Requirements 1.6 m3 for 7 days or 6.9 m3 based on 30 days.
Notes:
a) SI storage tank capacity for ON-TK-1903 is 100 litres based on 7 days storage of
1m3 or for a period of 30days whichever is higher.
28
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
b) New U Field SI injection pumps to inject into 1x0.5” SI cores in the S1VA chemical
TUTU.
a) New pump capacity is significantly higher than current capacity of 0.32 litres/hr at
137 Bara.
The new gas turbine generator (GTG) for OMF (GT-N11001) is to be installed at the
S1VA facilities and integrated into the S1VA power generating system. This additional
GTG will make-up an N+1 GTG configuration to meet all total power demand for OMF
and S1VA Terminal.
The initial site rated load of 4 MW for the GTG should be further reviewed due to
additional loads associated with U Field production via Vashishta terminal such as
Lean MEG / chemical injection pumps / transfer pumps and a potential power shortfall
of 0.3 MW at the Vashishta terminal itself. GTG set similar to the two existing at
Vashishta (ON-Z-2601 A/B) is preferable from a maintenance and spare parts
perspective.
Installation and integration of new GTG set at Vashishta terminal shall be in readiness
for first gas from U Field (i.e. 6 months before OMF is fully operational).
Waste Heat Recovery Unit (WHRU) shall be provided for the new GTG at Odalarevu for
heat transfer to the OMF Hot Oil system as a means of potentially reducing the
number of fired heaters required meeting the total heat load in line with Ministry of
Environment, Forest & Climate change circular no. : F. No. J-11011/316/2014-IA II(I)
Dated : 22/01/2016, para 4 (this circular is part of 402020-01391-01-SY-BOD-0001-0G
Overall Design Basis page no. 174)
29
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Based on preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
Bidders to note the OMF fuel gas source is changed from gas separators V-N78152
A/B (now relocated to Mallavaram OGT) which handled export gas from CPP which
had been dehydrated offshore on CPP. The new source for OMF fuel gas is from the
dry gas outlet from the new U Field gas dehydration unit (GDU). The fuel gas supply
for OMF is to be metered to measure OMF fuel gas consumption.
OMF fuel gas package to be designed for 10 MMSCFD. Bidders to verify. The main
consumers of fuel gas being the new OMF gas turbine generator and the hot oil fired
heaters which require 60 MW (TBC by Vendor) heating.
The fuel gas operating pressure for the new GTG is to be confirmed by GTG Vendor
(estimated to be approximately 20 barg).
Vendor for the OMF fuel gas package A-N76001 is to confirm knockout pot (SP-XX1)
requirements, and filter coalescer requirements.
Fuel Gas compositions are provided in the Table 4 below:
30
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Bidders are advised of new HP Flare in OMF Odalarevu as part of existing scope to
handle total envisaged production of 98/2 project shall now be designed to handle
full flow relief capacity of 10.05 MMSCMD with 5.75 MMSCMD gas from U Field and
4.3 MMSCMD gas from Vashishta S1-VA production rate . The OMF LP and LLP flare
as required in original scope are to be provided.
31
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
OMF HP flare lines (from Lean MEG launcher, Rich MEG receiver and OMF Fuel Gas
system) are to be tied into the new 36” HP flare header to the new HP Flare KO Drum
which is to be designed to cater for both S1-VA, U Field and OMF HP flaring
requirements. Note HP flare lines from Lean MEG launcher & Rich MEG receiver are
for manual blowdown or thermal relief.
Vashishta and U Field facilities are to be fully integrated in terms of PCS, ESD, fire
zoning, etc.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
The new flare should be located adjacent to the existing flare in the allocated flare
area in the OMF plant. A 200m length extension to the current 36” HP Flare header is
considered. A 90 m radius for the sterile zone limit can be considered based on
preliminary plot plan for OMF.
New HP Flare system will minimise downtime compared with a replacement flare
which could increase significantly plant downtime / planned shutdown period (in
terms of construction/installation).
Flare package shall be designed for the complete combustion of flare gases. The
package unit shall consist of as a minimum:
Flare Stack
Flare Tip (burner tip)
Seal system for flashback protection
Flame Front Generator (FFG)
32
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Vendor shall provide the following process data with the flare package:
Process description
Control philosophy
Radiation maps / dispersion study results
Pressure drop/flow profile in the flare
Equipment list
Utility requirements
Noise profile
Length and height of flame without wind and design wind velocity
Material of construction
Availability
Number of pilot burners
Process Guarantees:
33
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
New Flare:
Notes:
1. Flare Vendor to note system pressure drop to be limited to 0.25 bar (for Flare
Stack Riser + Molecular Seal + Flare Tip).
2. Flare height calculated based on max wind velocity of 27.5 m/s with 90m sterile
zone radius and 36” Flare tip assumed. Maximum allowable radiation shall be limited
as per requirements of API RP 521.
3. The minimum stack height shall be such that the total radiation (flare radiation +
solar radiation) is within the API RP 521 permissible limit of 6.31 kW/m2 (includes
solar radiation of 1.04 kW/m2) at sterile radius from stack base.
4. Existing Vashishta flare height is 49.5m and has 36” Flare Riser with 32” Flare Tip
and 32”Molecular Seal with 90m sterile zone.
5. Flare header shall be purged by all units maintaining a minimum Purge velocity of
0.1 fps in respective unit headers with fuel gas. In addition all dead ends of flare
headers shall be purged with fuel gas.
6. An ultrasonic flow meter shall be provided for flare gas flow measurement
downstream of main KOD in hydrocarbon flare header.
New Flare KO Drum is not part of New Flare package and effectively replaces the OMF
HP Flare KO Drum V-N75152.
Based on preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
34
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
Process Data:
Diameter 4.2 m
Length 17 m
Design pressure 3.5 barg
Operating pressure 0.7 barg to 1.5 barg.
Design temperature 220 oC (max) / -46 oC
MOC LTCS (3mm CA)
Inlet Nozzle 36” (2 off)
Gas Outlet Nozzle 44”
Liquid outlet 2”
Utility Data:
Instrument Air Operating Temp & Pressure 50oC and 7.5 to 4.5 barg
LP Fuel Gas Operating Temp & Pressure 24oC and 5 to 4 barg
Bidders should note that the new Flare KO Drum dimensions are the same as existing
Vashishta Flare KO Drum (ON-V-2701). However outlet nozzle is increased from 42” to
44”.
New Flare KO Drum Pumps are not part of new Flare package and effectively replace
the OMF HP Flare KO Drum Pumps P-N75552 A/B.
The new Flare KO Drum Pumps shall have a capacity of 5m3/hr with differential
pressure of 6.84 bar. This specification is the same as the existing Flare KO Drum
Pumps ON-P-2701 A/B (2x100%).
Blowdown calculations and fire relief calculations have been performed for the new U
Field separators, U Field GDU, U Field fuel gas package.
Results for U Field separators, located in Vashishta slugcatcher area indicate the
current flare capacity of 7 MMSCMD is adequate for blowdown scenarios. Refer to
Figure 1 Summary of Blowdown Calculations for U Field separators and U Field GDU
and fuel gas system.
35
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
The blowdown rates for the U Field Gas Dehydration Unit (GDU) have been estimated
from previous Vashishta studies performed on a very similar sized unit (3.5 MMSCMD
operating at 62 barg with 80 barg design pressure). The GDU blowdown rate was
considered to be 4000 kg/hr per unit.
The blowdown rates for the U Field / OMF fuel gas system have been estimated from
previous Vashishta studies performed on a very similar sized unit (7 MMSCFD
operating at 20 barg). The fuel gas system blowdown rate was considered to be 3000
kg/hr unit.
Receival area is physically well separated from the main process area. Therefore a fire
can be considered confined to one of the two areas. The U Field separators are to be
located in the receival area where the slugcatcher and the pig launcher / receiver are
located. The U Field GDU is assumed to be located in the main process area. A 15
minute time delay is considered for simultaneous blowdown of the two areas. This
staggered area wise blowdown keeps the total blowdown rate for the two areas to
within flare capacity of 7 MMSCMD (213,000kg/hr).
From Figure 1 it can be concluded that the current flare capacity of 7 MMSCMD is
adequate for staggered plant blowdown with U Field production at Vashishta.
Peak blowdown load of 31600 kg/hr per separator is calculated requiring a 630mm2
orifice. Bidders to verify blowdown orifice sizing. Minimum blowdown temperature of
-8oC is calculated for the U Field separator vessels. Bidders to verify orifice sizing in
detailed design.
Peak full flow relief load (2.875 MMSCMD) for each U Field separator is calculated to
be 87620 kg/hr requiring a 4L6 relief valve with a 10” inlet line. Bidders to verify PSV
sizing in detailed design.
36
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
@ 161,119 kg/h
100,000
50,000
0
0 200 400 600 800 1000 1200 1400 1600 1800
Time (seconds)
Flare study has been performed for the new HP flare at ONGC KG-DWN-98/2 MEG
Facility. The following conclusions are made:
The new HP flare stack height will need to be 55.6 m if a tip of 914.4 mm (36’’)
diameter is used. This is to maintain the sterile area boundary radius of 90 m and
satisfy the thermal radiation acceptance criterion at all receptor points.
A minimum of flare stack height 50.1 m is required for the new HP flare if a smaller tip
37
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
812.8 mm (32’’) diameter can be used. This is to ensure the thermal radiation criterion
is met and to maintain the sterile area boundary radius of 90 m.
Based on a minimum height of 49.5 m flare stack with a 32’’ flare tip diameter (as per
existing HP flare at Vashishta) the thermal radiation criterion of 6.31 kW/m2 is
marginally exceeded with a calculated value of 6.38 kW/m2.
The maximum allowable noise limit during emergency condition of 115 dB(A) is not
exceeded for all study cases analysed.
Gas dispersion study cases show that the extent of 50% LFL and 100% LFL flammable
gas clouds do not descend downwards encroaching the receptor points at ground
level regardless of the wind conditions.
Flare Vendor to verify results and confirm flare tip size and hence flare height.
38
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
n-Octane 0.000000
n-Nonane 0.000000
n-Decane 0.000000
EGlycol 0.000000
TEGlycol 0.000000
H2O 0.000283
Oxygen 0.000923
The OMF Hot Oil Heating system is required to provide heating for the OMF MEG
reclamation and regeneration plant. Vendor to confirm total estimated hot oil heating
requirement of 60 MW for MEG reclamation and regeneration.
The MEG reclaimer configuration is for 3 x 33% trains with each train having a 22
m3/hr Rich MEG processing capacity. Two trains to be installed initially with the third
train being a future train. However, Bidder may propose a better option during
detailed engineering for Company’s consideration.
Hot Oil Configuration in OMF is 1 x 66% installed and 1 x 33% future or 2 x 33%
installed and 1 x 33% future. However, Bidder may propose a better option during
detailed engineering for Company’s consideration.
Waste Heat Recovery Unit (WHRU) shall be provided for the new GTG at Odalarevu for
heat transfer to the OMF Hot Oil system as a means of potentially reducing the fired
heaters duty needed to meet the total heat load.
Bidders to note the existing Vashishta Hot oil system is to supply the new U Field GDU
reboiler which will be operational 6 months before OMF comes online. The MEG
regeneration package (ON-Z-1801) at Vashishta which is the main user for hot oil
heating (4.7 MW) will not be operating at capacity when U Field production first
comes online. Therefore Vashishta hot oil system will have enough heating capacity to
supply the U Field GDU reboiler (0.4 to 0.5 MW estimated) initially. The MEG
regeneration package (ON-Z-1801) at Vashishta will be mothballed once OMF comes
39
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas
Pipeline (OMF) Terminal under KG DWN 98/2
Development Project
Tender No. K07DC16051
Revision 0E
into operation some 6 months after U Field first gas. This means all of its heating duty
will become available for other users such as new U Field GDU reboiler.
40
Rev.0D – 27/03/18
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
6 MALLAVARAM
6.1 Introduction
Custody metering skid 2x100% metering runs (refer sec 4.2.3 of 402020-
01391-08-PR-BOD-0001, Rev 0E),
The 20” gas receiver dimensions remain unchanged based on a 20” pipeline.
However the two separators (2x100%) and the metering package (2x100%
metering runs) are re-sized based on the new design flowrate of 11.5 MMSCMD.
Bidders to note, OMF P&IDs (PID for export gas receiver, export gas separators
and export gas custody meter have been updated to reflect the change in
flowrate and re-location to Mallavaram OGT from OMF. The modified P&IDs that
are included in this Addendum document for OMF to carry suffix ‘(M)’. Equipment
numbering has been retained for identification purposes only.
6.2 General
It is anticipated that all the existing utilities of OGT will be used for new facilities
with the required modifications, if any and integration of the new facilities to OGT
Mallavaram. Main utilities identified as HP Flare, Closed Drains, Fuel Gas and
Instrument Air systems.
Page 41 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Bidder shall assess and identify the optimum tie-in points to the above utility
headers and any other utilities. Bidder shall submit the proposed tie-in points for
Company’s approval.
Bidders’ Scope of Work for modification at OGT at Mallavaram for receiving 11.5
MMSCMD export gas from CPP shall include Survey, engineering, procurement,
transportation, fabrication, installation, hook-up, testing, pre-commissioning and
commissioning of all systems required, which shall include, but not be limited to
the following:
i. Geotechnical & Site Surveys
ii. Site Preparation & Earthworks
iii. Foundations including Piles (Concrete or Steel Piles), Footings & Slabs
iv. 20” future tie-in to be provided with isolation valve downstream of gas
separators.
v. The provision for fuel gas supply line from outlet gas header of Gas Export
Separators to the existing fuel gas conditioning skid for GTGs of OGT,
Mallavaram. Provision for ultrasonic fuel gas flow meter along with
necessary isolation valves and piping connections.
xii. The tie-in of the 20” export gas pipeline at Mallavaram, beyond OGT
boundary wall is planned with the existing East West Pipeline (EWPL) of
Reliance Gas Transportation Infrastructure Limited (RGTIL). This tie-in from
OGT boundary wall to RGTILs’ EWPL is to be performed by others.
Page 42 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
xiii. Fire & Gas detection system and fire suppression system installation and
integration with the existing systems.
xiv. Fire water/ firefighting systems hook up and integration with existing
system
xv. Process Control System hook up and integration with existing system
xvi. Emergency Shutdown System (modifications to existing / new )
xvii. Instruments, Instrumentation, Interconnect Cabling & Instrument Loops
xviii. Primary, Secondary and Tertiary Structural Steelwork
xix. Other Steelwork incl. Access Platforms, Ladders, Stairways, Handrails and
Grating
xxiii. Security Systems including Emergency Lighting, CCTV, Fencing & Gates
(modifications to existing, if any)
xxxi. Warranty
Page 43 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Bidder is advised to re-confirm the design details as part of site visit prior to
submission of bids and / or proceeding with execution of the work after award. As
built drawing of OGT will be provided to successful bidder for identified hook up
points.
Bidder shall complete all safety studies (HAZOP, HAZID etc.) defined in Section
4.27 of the Onshore MEG and Gas Pipeline Terminal Scope of Work, 402020-
01391-08-PM-SOW-0001, for the Work associated with the Gas receiving and
custody transfer of gas at OGT, Mallavaram. This shall include assessment of the
impact on the existing facilities and carrying out any remedial work, if required.
The integrated facility should have QRA certificate. Company will provide Bidders
with current QRA documentation for Mallavaram OGT.
The 20” gas receiver dimensions remains unchanged based on a 20” pipeline.
Vendor is to confirm gas receiver dimensions and consider intelligent pigging
requirements.
From preliminary engineering the following data applies. Bidders to verify during
detailed engineering.
Page 44 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Notes:
a) Two phase separator considered (gas and liquid phases). No liquids expected from
CPP dry export gas composition under normal operations.
b) Feed Inlet Nozzle / Gas Outlet Nozzle are calculated to be 34” and 24”
respectively. Bidders to confirm.
c) 20” Inlet and 20” Gas Outlet line size and 20” inlet/outlet header size.
e) The two gas separator vessels to have provisions to operate in parallel and in
series.
f) The provision for fuel gas supply to existing GTGs of OGT, Mallavaram, is to be
made by providing T joint and Ultrasonic gas flow meter along with necessary
isolation valve and piping connection to the existing fuel gas conditioning skid.
Fuel gas take off point is to be from outlet gas header of Gas Export Separators
A/B.
Gas export specifications at Mallavaram are given in section 2.5 and pressure
requirements in section 2.6. All the regulatory guidelines of PNGRB and other
statutory authorities are to be followed. H2S Sensor, Moisture Sensor, CO2, HCDP
Sensor and Gas Chromatograph to be provided along with Custody meter.
The KG DWN 98/2 export gas from CPP will be metered (through a custody
metering to be provided as part of present scope) at Mallavaram. However
Contractor has to provide sales gas pipeline (20”) beyond the custody metering
with NRV along with necessary isolations, pressure controls, insulation joint and
cathodic protection up to the OGT boundary (battery limit for the scope). The tie-
Page 45 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
in of the export gas pipeline with the existing EWPL of RGTIL outside OGT
boundary is to be performed by others.
The HP flare at Mallavaram OGT has a governing load capacity of 125,000 kg/hr
based on a control valve failure and blocked discharge with relief from PSV 1102
A/B/C of GSU. This is based on a feed gas rate of 100 MMSCFD of slugcatcher gas
per train.
The gas export receiver, separators and custody metering package were
depressurised to determine their blowdown rate. A check was made to see if gas
flowrate to HP flare remains within the design capacity of the existing HP flare
system at Mallavaram OGT if a fire in the plant occurred with a blowdown of the
new gas export equipment.
Page 46 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
In the event of an external fire a maximum fire relief load from the GDU train area
of 32500 kg/hr is stated in Basis Engineering Design Basis Part-A for Flare System.
The blowdown load for each of the separators V-N78152 A/B is calculated to be
32.9 Te/hr. Assuming the export gas from the 20” gas export pipeline is received
by the gas separators V-N78152 A/B in the GDU area and they are automatically
depressured in the event of an external fire, then a total flare load of 65.4 Te/hr
(32.5 Te/hr + 32.9 Te/hr) is calculated. Even if both separators are operating as
2x50% vessels in parallel a total flare load of 98.3 Te/hr (32.5 Te/hr + 2 x 32.9
Te/hr) is calculated. In both cases total flare load is within the HP flare governing
capacity of 125 Te / hr. In both cases total flare load is within the HP flare
governing capacity of 125 Te / hr.
A maximum fire relief load from the slugcatcher area of 23670 kg/hr is stated in
Basis Engineering Design Basis Part-A for Flare System. If the separators V-N78152
A/B are located and depressured in the slugcatcher area, the peak HP flare load
would be reduced from 98.3 Te/hr to 89.5 Te/hr.
The fire relief for each of the separators V-N78152 A/B is calculated to be 15.7
Te/hr. If automatic blowdown is not considered and fire relief is considered only
then total HP flare load of 48.2 Te/hr (32.5 Te/hr + 15.7 Te/hr) is calculated. Even if
both separators are operating as 2x50% vessels in parallel a total flare load of 63.9
Te/hr (32.5 Te/hr + 2 x 15.7 Te/hr) is calculated. In both cases total flare load is
within the HP flare governing capacity of 125 Te / hr.
The new gas export receiver, gas separators and custody metering package are all
fully rated to the design pressure of the 20” gas export pipeline of 120 barg. In the
event of a blocked discharge there is no requirement to relieve any pressure
accumulation to HP flare in terms of pressure protection since all equipment is
fully rated.
Page 47 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
There are no PCVs to flare from the new gas export equipment and therefore no
risk of high flowrates to HP flare in the event of a control valve failure or blocked
discharge.
The results for the fire case and depressurising case for gas separators V-N78152
A/B are summarised in Table 6.
The selected PSV size is 1½G3, with an inlet line size of 6” and outlet line size of
10”.
A blowdown orifice size of 642 mm2 is required with an inlet line size of 6” and
outlet line size of 10”.
Table 6 – Gas Separators V-N78152 A/B Fire Relief & Blowdown Summary
Configuration 2x100%
1½G3
Page 48 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
Page 49 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
7 IOPS
7.1 COMPANY advises Bidder to note revised IOPS requirements as a result of the
above changes.
i. The scope shall include supply of OPC enabled server (including complete
hardware, software and requisite licenses etc.) for SCADA connectivity. PCS /
PLCs / Flow computer installed at OGT shall in general be OPC enabled and
server shall be equipped with ‘Firewall’ against communication / access
from outside.
ii. The equipment so provided shall be sufficient for supporting all the data
points as envisaged at this facility through this contract and capacity
sufficient for providing an additional 100 data points to meet future
requirement. The selected OGT data shall be included in the workflows
described in the IOPS functional specification 402020-01391-08-IS-FSP-
0001. Estimated number and type of points, to be gathered at OGT, and
transferred to Kakinada will be provided by Company.
iii. The data acquired shall be transferred to IDC at Kakinada through the
existing communication network (Leased lines / Microwave). No separate
communication needs to be provided for this purpose. However bidder to
note that equipment / hardware as required shall be provided for
connectivity to the existing LAN and for receiving the data at IDC, Kakinada
by employing suitable encryption / decryption in order to protect the
integrity and security of the data.
iv. Section 14.1 Training categories (page 130) of Functional Specification for
Integrated Operations Systems 402020-01391-08-IS-FSP-0001 Revision 0D,
to be modified as:
“One training session covering System configuration, system maintenance,
work-flow design and development, and application development shall be
fifteen (15) working days for a batch of ten (10) people minimum. Each data
analytics application may have more than one module if required”.
Page 50 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 51 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 52 of 74
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during summer - 10.05 MMSCMD
Stream Name U-1 Sat U-3 Sat U_MEG Injection U_Produced Water U_100A U_100 U_101 U_102 U_103 U_132 U_140 U_141 U_203 U_400 U_401
Note:
1. Gas rate of 3 MMSCMD is considered for vessel sizing purpose based on the design capacity of each separator. Total capacity for both operating vessels shall be 5.75 MMSCMD.
2. Total flowrate is based on aqueous phase of stream U_100A at U field full production capacity of 5.75 MMSCMD.
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during summer - 10.05 MMSCMD
VA_Produced
Stream Name U_402 U_403 U_404 S-2 Sat VA-1A Sat VA-2 Sat VA_MEG injection 100A 100 101 103 108 109 110
Water
Fuel Gas (U Field) Fuel Gas (U Field) Fuel Gas (U Field) Produced Water Total Vashishta Vashishta Field Gas from Gas/Gas
Production Fluid Production Fluid Production Fluid MEG Injection for Gas from Slug Rich MEG from Gas from Inlet Gas to Existing
Description from New FG Hot to New Generator to distribution for from Vashishta Field Production Production Fluid Exchanger Pass
from S-2 Field from VA-1A Field from VA-2 Field Vashishta Field Catcher Slug Catcher Scrubber Compressors
Oil Heater Gas Turbine new facilities Field Fluid to Slug Catcher 'A'
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.9934 0.9934 1.0000 0.0000 1.0000 1.0000 1.0000
o
Temperature C 54.83 53.07 46.87 30.00 70.90 30.00 30.00 30.00 30.00 30.00 29.86 29.86 29.21 35.00 35.00
Pressure bar g 24.50 20.00 5.00 9.00 254.00 9.00 9.00 9.00 9.00 9.00 8.80 8.80 7.50 7.00 7.00
Molar Flow kgmol/h 499.01 99.80 399.20 1321.66 1409.77 4846.10 11.88 37.64 7627.06 7627.06 7576.87 50.19 7576.87 7576.87 2121.78
Mass Flow kg/h 8099.97 1619.99 6479.98 22294.97 24080.06 81691.16 494.97 678.16 129239.31 129239.31 128055.55 1183.76 128055.55 128055.55 35859.90
Molecular Weight kg/kmol 16.23 16.23 16.23 16.87 17.08 16.86 41.68 18.02 16.94 16.94 16.90 23.59 16.90 16.90 16.90
3
Mass Density kg/m 15.79 13.00 3.71 6.85 168.77 6.85 1094.37 1003.84 6.93 6.93 6.73 1045.44 5.83 5.38 5.38
Heat Flow MW -10.31 -2.06 -8.25 -27.92 -30.28 -102.27 -1.24 -2.99 -164.27 -164.27 -159.99 -4.27 -159.99 -159.51 -44.67
Mass Enthalpy kJ/kg -4581.7 -4581.7 -4581.7 -4508.0 -4526.3 -4507.0 -8990.8 -15865.4 -4575.7 -4575.7 -4497.9 -12996.0 -4497.9 -4484.4 -4484.4
GAS PHASE
Molar flow kgmol/h 499.01 99.80 399.20 1321.66 1409.77 4846.10 --- --- 7576.57 7576.57 7576.87 --- 7576.87 7576.87 2121.78
Mass Flow kg/h 8099.97 1619.99 6479.98 22294.97 24080.06 81691.16 --- --- 128049.99 128049.99 128055.55 --- 128055.55 128055.55 35859.90
3
Act Volume Flow Am /h 513.02 124.64 1748.24 3253.53 142.68 11930.11 --- --- 18649.60 18649.60 19029.23 --- 21948.91 23818.34 6669.94
Std Gas Flow MMSCMD 0.28 0.06 0.23 0.75 0.80 2.75 --- --- 4.30 4.30 4.30 --- 4.30 4.30 1.20
Std Gas Flow MMSCFD 10.00 2.00 8.00 26.49 28.25 97.12 --- --- 151.83 151.83 151.84 --- 151.84 151.84 42.52
Molecular Weight kg/kmol 16.23 16.23 16.23 16.87 17.08 16.86 --- --- 16.90 16.90 16.90 --- 16.90 16.90 16.90
o
Mass Heat Capacity kJ/kg C 2.42 2.39 2.30 2.25 3.19 2.25 --- --- 2.25 2.25 2.25 --- 2.24 2.25 2.25
3
Mass Density kg/m 15.79 13.00 3.71 6.85 168.77 6.85 --- --- 6.87 6.87 6.73 --- 5.83 5.38 5.38
o
Thermal Conductivity W/m K 0.0399 0.0393 0.0372 0.0345 0.0697 0.0345 --- --- 0.0345 0.0345 0.0344 --- 0.0342 0.0350 0.0350
Viscosity cP 0.0127 0.0126 0.0121 0.0116 0.0221 0.0116 --- --- 0.0116 0.0116 0.0116 --- 0.0116 0.0118 0.0118
Z Factor 0.9619 0.9676 0.9897 0.9780 0.9023 0.9780 --- --- 0.9779 0.9779 0.9783 --- 0.9810 0.9832 0.9832
Cp / Cv 1.349 1.340 1.306 1.321 1.645 1.321 --- --- 1.320 1.320 1.319 --- 1.316 1.311 1.311
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- --- 11.88 --- --- --- --- --- --- --- ---
Mass Flow kg/h --- --- --- --- --- --- 494.97 --- --- --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- --- 0.45 --- --- --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- --- 67.59 --- --- --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- --- 2.82 --- --- --- --- --- --- --- ---
3
Mass Density kg/m --- --- --- --- --- --- 1094.37 --- --- --- --- --- --- --- ---
o
Thermal Conductivity W/m. K --- --- --- --- --- --- 0.302 --- --- --- --- --- --- --- ---
Viscosity cP --- --- --- --- --- --- 5.72 --- --- --- --- --- --- --- ---
Surface Tension dynes/cm --- --- --- --- --- --- 51.71 --- --- --- --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- --- --- --- 37.64 50.49 50.49 --- 50.19 --- --- ---
Mass Flow kg/h --- --- --- --- --- --- --- 678.16 1189.32 1189.32 --- 1183.76 --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- --- --- 0.68 1.14 1.14 --- 1.13 --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- --- --- 100.9 169.9 169.9 --- 169.1 --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- --- --- --- 4.312 3.715 3.715 --- 3.712 --- --- ---
3
Mass Density kg/m --- --- --- --- --- --- --- 1003.84 1045.15 1045.15 --- 1045.44 --- --- ---
o
Thermal Conductivity W/m K --- --- --- --- --- --- --- 0.6182 0.4777 0.4777 --- 0.4769 --- --- ---
Viscosity cP --- --- --- --- --- --- --- 0.797 1.538 1.538 --- 1.548 --- --- ---
Surface Tension dynes/cm --- --- --- --- --- --- --- 71.23 62.58 62.58 --- 62.56 --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0061 0.0061 0.0061 0.0119 0.0106 0.0122 0.0000 0.0000 0.0118 0.0118 0.0119 0.0000 0.0119 0.0119 0.0119
Oxygen 0.0016 0.0016 0.0016 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
CO2 0.0023 0.0023 0.0023 0.0021 0.0023 0.0020 0.0000 0.0000 0.0021 0.0021 0.0021 0.0000 0.0021 0.0021 0.0021
Methane 0.9882 0.9882 0.9882 0.9568 0.9555 0.9570 0.0000 0.0000 0.9505 0.9505 0.9568 0.0000 0.9568 0.9568 0.9568
Ethane 0.0016 0.0016 0.0016 0.0124 0.0120 0.0123 0.0000 0.0000 0.0122 0.0122 0.0123 0.0000 0.0123 0.0123 0.0123
Propane 0.0001 0.0001 0.0001 0.0075 0.0072 0.0074 0.0000 0.0000 0.0073 0.0073 0.0074 0.0000 0.0074 0.0074 0.0074
i-Butane 0.0000 0.0000 0.0000 0.0014 0.0027 0.0013 0.0000 0.0000 0.0016 0.0016 0.0016 0.0000 0.0016 0.0016 0.0016
n-Butane 0.0000 0.0000 0.0000 0.0020 0.0046 0.0019 0.0000 0.0000 0.0024 0.0024 0.0024 0.0000 0.0024 0.0024 0.0024
i-Pentane 0.0000 0.0000 0.0000 0.0006 0.0011 0.0006 0.0000 0.0000 0.0007 0.0007 0.0007 0.0000 0.0007 0.0007 0.0007
n-Pentane 0.0000 0.0000 0.0000 0.0005 0.0008 0.0005 0.0000 0.0000 0.0006 0.0006 0.0006 0.0000 0.0006 0.0006 0.0006
n-Hexane 0.0000 0.0000 0.0000 0.0004 0.0005 0.0004 0.0000 0.0000 0.0004 0.0004 0.0004 0.0000 0.0004 0.0004 0.0004
n-Heptane 0.0000 0.0000 0.0000 0.0000 0.0003 0.0000 0.0000 0.0000 0.0001 0.0001 0.0001 0.0000 0.0001 0.0001 0.0001
n-Octane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Nonane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.5372 0.0000 0.0008 0.0008 0.0000 0.1265 0.0000 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0000 0.0000 0.0000 0.0043 0.0025 0.0043 0.4628 1.0000 0.0096 0.0096 0.0039 0.8735 0.0039 0.0039 0.0039
Total 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during summer - 10.05 MMSCMD
Stream Name 111 112 127 128 130 132 136 137 138 139 139A 140 141 157 158
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 0.9998 0.9991 1.0000 1.0000 0.9999 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000
o
Temperature C 35.00 34.42 57.20 50.00 45.94 38.00 41.60 5.00 -1.50 -1.65 31.36 41.07 39.33 38.00 -1.65
Pressure bar g 7.00 5.80 67.50 67.50 62.70 66.10 64.00 63.30 62.60 62.30 61.98 61.38 60.08 66.10 62.30
Molar Flow kgmol/h 5455.09 2121.78 5450.98 3877.45 13293.42 13293.42 13265.84 13265.84 13265.84 13264.11 13264.11 13264.11 18570.19 12.04 1.72
Mass Flow kg/h 92195.66 35859.90 92120.65 68871.46 225357.17 225357.17 224859.71 224859.71 224859.71 224729.43 224729.43 224729.43 310603.95 217.30 130.29
Molecular Weight kg/kmol 16.90 16.90 16.90 17.76 16.95 16.95 16.95 16.95 16.95 16.94 16.94 16.94 16.73 18.05 75.59
3
Mass Density kg/m 5.38 4.57 46.59 51.30 45.45 49.98 47.38 57.10 58.83 58.52 48.05 45.37 43.98 999.94 661.38
Heat Flow MW -114.84 -44.67 -114.72 -84.11 -282.68 -284.31 -281.58 -287.69 -288.77 -288.68 -283.06 -281.42 -392.90 -0.95 -0.09
Mass Enthalpy kJ/kg -4484.4 -4484.4 -4483.2 -4396.3 -4515.7 -4541.8 -4508.1 -4605.8 -4623.2 -4624.4 -4534.4 -4508.2 -4553.9 -15800.9 -2464.4
GAS PHASE
Molar flow kgmol/h 5455.09 2121.78 5450.98 3877.45 13290.70 13281.39 13265.84 13265.84 13264.23 13264.11 13264.11 13264.11 18570.19 --- ---
Mass Flow kg/h 92195.66 35859.90 92120.65 68871.46 225307.78 225139.86 224859.71 224859.71 224738.61 224729.43 224729.43 224729.43 310603.95 --- ---
3
Act Volume Flow Am /h 17148.40 7849.10 1977.37 1342.49 4958.49 4508.70 4745.81 3937.78 3822.19 3839.99 4676.85 4952.90 7062.84 --- ---
Std Gas Flow MMSCMD 3.10 1.20 3.09 2.20 7.54 7.54 7.53 7.53 7.53 7.53 7.53 7.53 10.54 --- ---
Std Gas Flow MMSCFD 109.32 42.52 109.24 77.70 266.34 266.16 265.85 265.85 265.81 265.81 265.81 265.81 372.14 --- ---
Molecular Weight kg/kmol 16.90 16.90 16.90 17.76 16.95 16.95 16.95 16.95 16.94 16.94 16.94 16.94 16.73 --- ---
o
Mass Heat Capacity kJ/kg C 2.25 2.24 2.64 2.64 2.62 2.66 2.64 2.78 2.83 2.82 2.64 2.62 2.62 --- ---
3
Mass Density kg/m 5.38 4.57 46.59 51.30 45.44 49.93 47.38 57.10 58.80 58.52 48.05 45.37 43.98 --- ---
o
Thermal Conductivity W/m K 0.0350 0.0348 0.0435 0.0422 0.0417 0.0411 0.0413 0.0373 0.0367 0.0366 0.0399 0.0410 0.0408 --- ---
Viscosity cP 0.0118 0.0117 0.0139 0.0138 0.0135 0.0134 0.0134 0.0125 0.0124 0.0124 0.0131 0.0133 0.0132 --- ---
Z Factor 0.9832 0.9856 0.9049 0.8829 0.8960 0.8807 0.8888 0.8255 0.8116 0.8120 0.8773 0.8918 0.8943 --- ---
Cp / Cv 1.311 1.307 1.456 1.477 1.470 1.506 1.487 1.638 1.675 1.674 1.512 1.479 1.479 --- ---
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- --- --- --- 1.60 --- --- --- --- --- 1.72
Mass Flow kg/h --- --- --- --- --- --- --- --- 121.11 --- --- --- --- --- 130.29
3
Act Volume Flow Am /h --- --- --- --- --- --- --- --- 0.18 --- --- --- --- --- 0.20
Std Liquid Flow barrel/day --- --- --- --- --- --- --- --- 28.42 --- --- --- --- --- 30.57
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- --- --- --- 2.11 --- --- --- --- --- 2.11
3
Mass Density kg/m --- --- --- --- --- --- --- --- 661.26 --- --- --- --- --- 661.38
o
Thermal Conductivity W/m. K --- --- --- --- --- --- --- --- 0.106 --- --- --- --- --- 0.106
Viscosity cP --- --- --- --- --- --- --- --- 0.40 --- --- --- --- --- 0.40
Surface Tension dynes/cm --- --- --- --- --- --- --- --- 14.57 --- --- --- --- --- 14.59
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- 2.72 12.04 --- --- --- --- --- --- --- 12.04 ---
Mass Flow kg/h --- --- --- --- 49.39 217.30 --- --- --- --- --- --- --- 217.30 ---
3
Act Volume Flow Am /h --- --- --- --- 0.05 0.22 --- --- --- --- --- --- --- 0.22 ---
Std Liquid Flow barrel/day --- --- --- --- 7.3 32.3 --- --- --- --- --- --- --- 32.3 ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- 4.293 4.302 --- --- --- --- --- --- --- 4.302 ---
3
Mass Density kg/m --- --- --- --- 994.75 999.94 --- --- --- --- --- --- --- 999.94 ---
o
Thermal Conductivity W/m K --- --- --- --- 0.6341 0.6290 --- --- --- --- --- --- --- 0.6290 ---
Viscosity cP --- --- --- --- 0.636 0.677 --- --- --- --- --- --- --- 0.677 ---
Surface Tension dynes/cm --- --- --- --- 68.18 69.77 --- --- --- --- --- --- --- 69.77 ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0119 0.0119 0.0119 0.0067 0.0087 0.0087 0.0087 0.0087 0.0087 0.0087 0.0087 0.0087 0.0079 0.0000 0.0010
Oxygen 0.0000 0.0000 0.0000 0.0000 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0008 0.0000 0.0001
CO2 0.0021 0.0021 0.0021 0.0041 0.0027 0.0027 0.0027 0.0027 0.0027 0.0027 0.0027 0.0027 0.0026 0.0000 0.0024
Methane 0.9568 0.9568 0.9575 0.9363 0.9603 0.9603 0.9623 0.9623 0.9623 0.9624 0.9624 0.9624 0.9702 0.0000 0.3125
Ethane 0.0123 0.0123 0.0123 0.0187 0.0110 0.0110 0.0110 0.0110 0.0110 0.0110 0.0110 0.0110 0.0081 0.0000 0.0172
Propane 0.0074 0.0074 0.0074 0.0171 0.0080 0.0080 0.0081 0.0081 0.0081 0.0081 0.0081 0.0081 0.0056 0.0000 0.0395
i-Butane 0.0016 0.0016 0.0016 0.0038 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018 0.0012 0.0000 0.0194
n-Butane 0.0024 0.0024 0.0024 0.0051 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0017 0.0000 0.0378
i-Pentane 0.0007 0.0007 0.0007 0.0018 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0006 0.0000 0.0277
n-Pentane 0.0006 0.0006 0.0006 0.0015 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0005 0.0000 0.0298
n-Hexane 0.0004 0.0004 0.0004 0.0012 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0004 0.0000 0.0652
n-Heptane 0.0001 0.0001 0.0001 0.0005 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0001 0.0000 0.0593
n-Octane 0.0000 0.0000 0.0000 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0447
n-Nonane 0.0000 0.0000 0.0000 0.0006 0.0002 0.0002 0.0002 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0000 0.3434
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0008 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0039 0.0039 0.0032 0.0023 0.0022 0.0022 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.9991 0.0001
Total 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during summer - 10.05 MMSCMD
Stream Name 159 160 161 162 203 208 210 211 212 400 401 402 403 404
TOTAL
Vapour Fraction 0.0982 0.3523 0.0000 0.0355 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 1.0000 1.0000
o
Temperature C 40.00 32.21 58.25 41.53 30.02 40.00 40.00 41.18 40.00 41.07 48.59 58.87 57.07 50.76
Pressure bar g 61.30 5.50 18.00 5.50 2.60 0.00 0.00 125.00 1.50 61.38 60.88 24.50 20.00 5.00
Molar Flow kgmol/h 1.72 1.72 4.11 17.87 50.19 127.77 127.77 127.77 49.73 358.79 358.79 358.79 87.16 271.62
Mass Flow kg/h 130.29 130.29 75.00 422.59 1183.76 2301.73 2301.73 2301.73 2357.35 6078.78 6078.78 6078.78 1476.76 4602.01
Molecular Weight kg/kmol 75.59 75.59 18.24 23.64 23.59 18.02 18.02 18.02 47.41 16.94 16.94 16.94 16.94 16.94
3
Mass Density kg/m 496.19 52.45 984.46 142.84 1045.06 995.96 995.96 998.99 1091.45 45.37 43.47 16.31 13.42 3.82
Heat Flow MW -0.09 -0.09 -0.32 -1.36 -4.27 -10.12 -10.12 -10.11 -5.46 -7.61 -7.58 -7.48 -1.82 -5.66
Mass Enthalpy kJ/kg -2368.4 -2368.4 -15594.6 -11623.0 -12996.0 -15823.1 -15823.1 -15806.4 -8336.0 -4508.2 -4488.1 -4427.7 -4427.7 -4427.7
GAS PHASE
Molar flow kgmol/h 0.17 0.61 --- 0.64 --- --- --- --- --- 358.79 358.79 358.79 87.16 271.62
Mass Flow kg/h 3.04 12.99 --- 14.24 --- --- --- --- --- 6078.78 6078.78 6078.78 1476.76 4602.01
3
Act Volume Flow Am /h 0.06 2.31 --- 2.49 --- --- --- --- --- 133.97 139.83 372.72 110.03 1203.41
Std Gas Flow MMSCMD 0.00 0.00 --- 0.00 --- --- --- --- --- 0.20 0.20 0.20 0.05 0.15
Std Gas Flow MMSCFD 0.00 0.01 --- 0.01 --- --- --- --- --- 7.19 7.19 7.19 1.75 5.44
Molecular Weight kg/kmol 17.97 21.39 --- 22.42 --- --- --- --- --- 16.94 16.94 16.94 16.94 16.94
o
Mass Heat Capacity kJ/kg C 2.62 2.09 --- 2.09 --- --- --- --- --- 2.62 2.61 2.40 2.37 2.27
3
Mass Density kg/m 49.18 5.61 --- 5.71 --- --- --- --- --- 45.37 43.47 16.31 13.42 3.82
o
Thermal Conductivity W/m K 0.0403 0.0316 --- 0.0321 --- --- --- --- --- 0.0410 0.0418 0.0399 0.0393 0.0372
Viscosity cP 0.0134 0.0115 --- 0.0117 --- --- --- --- --- 0.0133 0.0135 0.0129 0.0127 0.0122
Z Factor 0.8744 0.9771 --- 0.9771 --- --- --- --- --- 0.8918 0.9017 0.9601 0.9661 0.9893
Cp / Cv 1.486 1.257 --- 1.243 --- --- --- --- --- 1.479 1.457 1.337 1.328 1.295
OIL PHASE
Molar Flow kgmol/h 1.55 1.12 --- 1.10 --- --- --- --- 49.73 --- --- --- --- ---
Mass Flow kg/h 127.24 117.30 --- 116.23 --- --- --- --- 2357.35 --- --- --- --- ---
3
Act Volume Flow Am /h 0.20 0.17 --- 0.17 --- --- --- --- 2.16 --- --- --- --- ---
Std Liquid Flow barrel/day 29.11 25.33 --- 25.06 --- --- --- --- 320.40 --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C 2.29 2.17 --- 2.21 --- --- --- --- 2.71 --- --- --- --- ---
3
Mass Density kg/m 633.93 684.01 --- 677.07 --- --- --- --- 1091.45 --- --- --- --- ---
o
Thermal Conductivity W/m. K 0.102 0.117 --- 0.115 --- --- --- --- 0.284 --- --- --- --- ---
Viscosity cP 0.29 0.43 --- 0.40 --- --- --- --- 5.55 --- --- --- --- ---
Surface Tension dynes/cm 12.99 18.32 --- 17.66 --- --- --- --- 49.14 --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- 4.11 16.14 50.19 127.77 127.77 127.77 --- --- --- --- --- ---
Mass Flow kg/h --- --- 75.00 292.12 1183.76 2301.73 2301.73 2301.73 --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- 0.08 0.29 1.13 2.31 2.31 2.30 --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- 11.1 43.4 169.1 342.4 342.4 342.4 --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- 4.297 4.305 3.713 4.316 4.316 4.301 --- --- --- --- --- ---
3
Mass Density kg/m --- --- 984.56 995.77 1045.06 995.96 995.96 998.99 --- --- --- --- --- ---
o
Thermal Conductivity W/m K --- --- 0.6444 0.6306 0.4771 0.6315 0.6315 0.6330 --- --- --- --- --- ---
Viscosity cP --- --- 0.525 0.681 1.542 0.651 0.651 0.637 --- --- --- --- --- ---
Surface Tension dynes/cm --- --- 65.85 69.06 62.54 69.49 69.49 69.29 --- --- --- --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0010 0.0010 0.0000 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0087 0.0087 0.0087 0.0087 0.0087
Oxygen 0.0001 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0005 0.0005 0.0005 0.0005 0.0005
CO2 0.0024 0.0024 0.0000 0.0003 0.0000 0.0000 0.0000 0.0000 0.0005 0.0027 0.0027 0.0027 0.0027 0.0027
Methane 0.3125 0.3125 0.0000 0.0301 0.0000 0.0000 0.0000 0.0000 0.0001 0.9624 0.9624 0.9624 0.9624 0.9624
Ethane 0.0172 0.0172 0.0000 0.0017 0.0000 0.0000 0.0000 0.0000 0.0000 0.0110 0.0110 0.0110 0.0110 0.0110
Propane 0.0395 0.0395 0.0000 0.0038 0.0000 0.0000 0.0000 0.0000 0.0000 0.0081 0.0081 0.0081 0.0081 0.0081
i-Butane 0.0194 0.0194 0.0000 0.0019 0.0000 0.0000 0.0000 0.0000 0.0000 0.0018 0.0018 0.0018 0.0018 0.0018
n-Butane 0.0378 0.0378 0.0000 0.0036 0.0000 0.0000 0.0000 0.0000 0.0000 0.0025 0.0025 0.0025 0.0025 0.0025
i-Pentane 0.0277 0.0277 0.0000 0.0027 0.0000 0.0000 0.0000 0.0000 0.0000 0.0008 0.0008 0.0008 0.0008 0.0008
n-Pentane 0.0298 0.0298 0.0000 0.0029 0.0000 0.0000 0.0000 0.0000 0.0000 0.0007 0.0007 0.0007 0.0007 0.0007
n-Hexane 0.0652 0.0652 0.0000 0.0063 0.0000 0.0000 0.0000 0.0000 0.0000 0.0005 0.0005 0.0005 0.0005 0.0005
n-Heptane 0.0593 0.0593 0.0000 0.0057 0.0000 0.0000 0.0000 0.0000 0.0000 0.0002 0.0002 0.0002 0.0002 0.0002
n-Octane 0.0447 0.0447 0.0000 0.0043 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Nonane 0.3434 0.3434 0.0000 0.0331 0.0000 0.0000 0.0000 0.0000 0.0000 0.0001 0.0001 0.0001 0.0001 0.0001
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0050 0.0017 0.1265 0.0000 0.0000 0.0000 0.6668 0.0000 0.0000 0.0000 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0001 0.0001 0.9949 0.9018 0.8735 1.0000 1.0000 1.0000 0.3325 0.0001 0.0001 0.0001 0.0001 0.0001
Total 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during winter - 10.05 MMSCMD
Stream Name U-1 Sat U-3 Sat U_MEG Injection U_Produced Water U_100A U_100 U_101 U_102 U_103 U_132 U_140 U_141 U_203 U_400 U_401
Note:
1. Gas rate of 3 MMSCMD is considered for vessel sizing purpose based on the design capacity of each separator. Total capacity for both operating vessels shall be 5.75 MMSCMD.
2. Total flowrate is based on aqueous phase of stream U_100A at U field full production capacity of 5.75 MMSCMD.
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during winter - 10.05 MMSCMD
VA_Produced
Stream Name U_402 U_403 U_404 S-2 Sat VA-1A Sat VA-2 Sat VA_MEG injection 100A 100 101 103 108 109 110
Water
Fuel Gas (U Field) Fuel Gas (U Field) Fuel Gas (U Field) Produced Water Total Vashishta Vashishta Field Gas from Gas/Gas
Production Fluid Production Fluid Production Fluid MEG Injection for Gas from Slug Rich MEG from Gas from Inlet Gas to Existing
Description from New FG Hot to New Generator to distribution for from Vashishta Field Production Production Fluid Exchanger Pass
from S-2 Field from VA-1A Field from VA-2 Field Vashishta Field Catcher Slug Catcher Scrubber Compressors
Oil Heater Gas Turbine new facilities Field Fluid to Slug Catcher 'A'
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.9932 0.9932 1.0000 0.0000 1.0000 1.0000 1.0000
o
Temperature C 33.75 31.73 24.59 11.00 70.90 11.00 11.00 11.00 11.00 11.00 10.87 10.87 10.14 35.00 35.00
Pressure bar g 24.50 20.00 5.00 9.00 254.00 9.00 9.00 9.00 9.00 9.00 8.80 8.80 7.50 7.00 7.00
Molar Flow kgmol/h 499.01 99.80 399.20 1321.66 1409.77 4846.10 11.87 37.64 7627.05 7627.05 7574.94 52.10 7574.94 7574.94 2121.78
Mass Flow kg/h 8099.89 1619.98 6479.91 22290.40 24080.06 81674.21 494.86 678.01 129217.53 129217.53 127998.13 1219.40 127998.13 127998.13 35852.95
Molecular Weight kg/kmol 16.23 16.23 16.23 16.87 17.08 16.85 41.68 18.02 16.94 16.94 16.90 23.40 16.90 16.90 16.90
3
Mass Density kg/m 17.06 14.04 4.00 7.35 168.77 7.34 1109.15 1018.03 7.43 7.43 7.22 1059.25 6.25 5.38 5.38
Heat Flow MW -10.42 -2.08 -8.34 -28.00 -30.28 -102.56 -1.24 -3.00 -164.96 -164.96 -160.51 -4.45 -160.51 -158.52 -44.40
Mass Enthalpy kJ/kg -4632.0 -4632.0 -4632.0 -4521.6 -4526.3 -4520.6 -9043.6 -15947.4 -4595.8 -4595.8 -4514.4 -13139.3 -4514.4 -4458.6 -4458.6
GAS PHASE
Molar flow kgmol/h 499.01 99.80 399.20 1321.66 1409.77 4846.10 --- --- 7574.85 7574.85 7574.94 --- 7574.94 7574.94 2121.78
Mass Flow kg/h 8099.89 1619.98 6479.91 22290.40 24080.06 81674.21 --- --- 127996.37 127996.37 127998.13 --- 127998.13 127998.13 35852.95
3
Act Volume Flow Am /h 474.85 115.42 1621.81 3033.33 142.68 11122.80 --- --- 17383.10 17383.10 17738.93 --- 20464.84 23812.82 6670.10
Std Gas Flow MMSCMD 0.28 0.06 0.23 0.75 0.80 2.75 --- --- 4.30 4.30 4.30 --- 4.30 4.30 1.20
Std Gas Flow MMSCFD 10.00 2.00 8.00 26.49 28.25 97.12 --- --- 151.80 151.80 151.80 --- 151.80 151.80 42.52
Molecular Weight kg/kmol 16.23 16.23 16.23 16.87 17.08 16.85 --- --- 16.90 16.90 16.90 --- 16.90 16.90 16.90
o
Mass Heat Capacity kJ/kg C 2.39 2.36 2.25 2.22 3.19 2.22 --- --- 2.21 2.21 2.21 --- 2.20 2.25 2.25
3
Mass Density kg/m 17.06 14.04 4.00 7.35 168.77 7.34 --- --- 7.36 7.36 7.22 --- 6.25 5.38 5.38
o
Thermal Conductivity W/m K 0.0369 0.0362 0.0339 0.0318 0.0697 0.0318 --- --- 0.0318 0.0318 0.0318 --- 0.0316 0.0351 0.0351
Viscosity cP 0.0121 0.0119 0.0114 0.0110 0.0221 0.0110 --- --- 0.0110 0.0110 0.0110 --- 0.0110 0.0118 0.0118
Z Factor 0.9515 0.9587 0.9868 0.9727 0.9023 0.9728 --- --- 0.9726 0.9726 0.9731 --- 0.9765 0.9832 0.9832
Cp / Cv 1.372 1.360 1.319 1.334 1.645 1.335 --- --- 1.334 1.334 1.333 --- 1.329 1.310 1.310
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- --- 11.87 --- --- --- --- --- --- --- ---
Mass Flow kg/h --- --- --- --- --- --- 494.86 --- --- --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- --- 0.45 --- --- --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- --- 67.57 --- --- --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- --- 2.74 --- --- --- --- --- --- --- ---
3
Mass Density kg/m --- --- --- --- --- --- 1109.15 --- --- --- --- --- --- --- ---
o
Thermal Conductivity W/m. K --- --- --- --- --- --- 0.295 --- --- --- --- --- --- --- ---
Viscosity cP --- --- --- --- --- --- 10.49 --- --- --- --- --- --- --- ---
Surface Tension dynes/cm --- --- --- --- --- --- 53.67 --- --- --- --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- --- --- --- 37.64 52.20 52.20 --- 52.10 --- --- ---
Mass Flow kg/h --- --- --- --- --- --- --- 678.01 1221.16 1221.16 --- 1219.40 --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- --- --- 0.67 1.15 1.15 --- 1.15 --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- --- --- 100.9 174.6 174.6 --- 174.4 --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- --- --- --- 4.317 3.701 3.701 --- 3.700 --- --- ---
3
Mass Density kg/m --- --- --- --- --- --- --- 1018.03 1059.11 1059.11 --- 1059.25 --- --- ---
o
Thermal Conductivity W/m K --- --- --- --- --- --- --- 0.5886 0.4611 0.4611 --- 0.4607 --- --- ---
Viscosity cP --- --- --- --- --- --- --- 1.264 2.349 2.349 --- 2.359 --- --- ---
Surface Tension dynes/cm --- --- --- --- --- --- --- 74.51 65.45 65.45 --- 65.46 --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0061 0.0061 0.0061 0.0120 0.0106 0.0123 0.0000 0.0000 0.0118 0.0118 0.0119 0.0000 0.0119 0.0119 0.0119
Oxygen 0.0016 0.0016 0.0016 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
CO2 0.0023 0.0023 0.0023 0.0021 0.0023 0.0020 0.0000 0.0000 0.0021 0.0021 0.0021 0.0000 0.0021 0.0021 0.0021
Methane 0.9882 0.9882 0.9882 0.9597 0.9555 0.9599 0.0000 0.0000 0.9528 0.9528 0.9594 0.0000 0.9594 0.9594 0.9594
Ethane 0.0016 0.0016 0.0016 0.0125 0.0120 0.0124 0.0000 0.0000 0.0122 0.0122 0.0123 0.0000 0.0123 0.0123 0.0123
Propane 0.0001 0.0001 0.0001 0.0075 0.0072 0.0074 0.0000 0.0000 0.0073 0.0073 0.0074 0.0000 0.0074 0.0074 0.0074
i-Butane 0.0000 0.0000 0.0000 0.0014 0.0027 0.0013 0.0000 0.0000 0.0016 0.0016 0.0016 0.0000 0.0016 0.0016 0.0016
n-Butane 0.0000 0.0000 0.0000 0.0020 0.0046 0.0019 0.0000 0.0000 0.0024 0.0024 0.0024 0.0000 0.0024 0.0024 0.0024
i-Pentane 0.0000 0.0000 0.0000 0.0006 0.0011 0.0006 0.0000 0.0000 0.0007 0.0007 0.0007 0.0000 0.0007 0.0007 0.0007
n-Pentane 0.0000 0.0000 0.0000 0.0005 0.0008 0.0005 0.0000 0.0000 0.0006 0.0006 0.0006 0.0000 0.0006 0.0006 0.0006
n-Hexane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Heptane 0.0000 0.0000 0.0000 0.0000 0.0003 0.0000 0.0000 0.0000 0.0001 0.0001 0.0001 0.0000 0.0001 0.0001 0.0001
n-Octane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Nonane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.5372 0.0000 0.0008 0.0008 0.0000 0.1265 0.0000 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0000 0.0000 0.0000 0.0043 0.0025 0.0043 0.4628 1.0000 0.0096 0.0096 0.0039 0.8735 0.0039 0.0039 0.0039
Total 1.0000 1.0000 1.0000 1.0026 0.9995 1.0026 1.0000 1.0000 1.0020 1.0020 1.0023 1.0000 1.0023 1.0023 1.0023
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during winter - 10.05 MMSCMD
Stream Name 111 112 127 128 130 132 136 137 138 139 139A 140 141 157 158
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 1.0000 0.9998 1.0000 1.0000 0.9999 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000
o
Temperature C 35.00 34.42 57.20 50.00 40.15 34.50 41.60 5.00 -1.50 -1.65 22.31 29.19 25.28 34.50 -1.65
Pressure bar g 7.00 5.80 67.50 67.50 62.70 66.10 64.00 63.30 62.60 62.30 61.98 61.38 60.08 66.10 62.30
Molar Flow kgmol/h 5453.16 2121.78 5453.16 3883.19 13301.35 13301.35 13286.01 13286.01 13286.01 13284.30 13284.30 13284.30 18593.02 2.43 1.71
Mass Flow kg/h 92145.19 35852.95 92145.19 68968.27 225474.87 225474.87 225198.27 225198.27 225198.27 225068.85 225068.85 225068.85 310985.37 43.97 129.42
Molecular Weight kg/kmol 16.90 16.90 16.90 17.76 16.95 16.95 16.95 16.95 16.95 16.94 16.94 16.94 16.73 18.12 75.60
3
Mass Density kg/m 5.38 4.57 46.57 51.30 46.66 50.81 47.38 57.10 58.83 58.52 50.36 48.06 47.09 1003.24 661.41
Heat Flow MW -114.12 -44.40 -114.27 -84.23 -283.19 -284.37 -281.99 -288.11 -289.19 -289.11 -284.98 -283.79 -396.56 -0.19 -0.09
Mass Enthalpy kJ/kg -4458.6 -4458.6 -4464.5 -4396.5 -4521.4 -4540.4 -4507.9 -4605.7 -4623.0 -4624.3 -4558.3 -4539.3 -4590.6 -15771.2 -2464.3
GAS PHASE
Molar flow kgmol/h 5453.16 2121.78 5453.16 3883.19 13301.35 13298.92 13286.01 13286.01 13284.42 13284.30 13284.30 13284.30 18593.02 --- ---
Mass Flow kg/h 92145.19 35852.95 92145.19 68968.27 225474.87 225430.90 225198.27 225198.27 225078.04 225068.85 225068.85 225068.85 310985.37 --- ---
3
Act Volume Flow Am /h 17142.72 7849.26 1978.49 1344.51 4831.96 4437.58 4753.05 3943.81 3828.05 3845.87 4469.46 4682.95 6603.85 --- ---
Std Gas Flow MMSCMD 3.09 1.20 3.09 2.20 7.55 7.55 7.54 7.54 7.54 7.54 7.54 7.54 10.55 --- ---
Std Gas Flow MMSCFD 109.28 42.52 109.28 77.82 266.56 266.51 266.25 266.25 266.22 266.22 266.22 266.22 372.60 --- ---
Molecular Weight kg/kmol 16.90 16.90 16.90 17.76 16.95 16.95 16.95 16.95 16.94 16.94 16.94 16.94 16.73 --- ---
o
Mass Heat Capacity kJ/kg C 2.25 2.24 2.64 2.64 2.63 2.67 2.64 2.78 2.83 2.82 2.67 2.65 2.65 --- ---
3
Mass Density kg/m 5.38 4.57 46.57 51.30 46.66 50.80 47.38 57.10 58.80 58.52 50.36 48.06 47.09 --- ---
o
Thermal Conductivity W/m K 0.0351 0.0349 0.0435 0.0422 0.0410 0.0407 0.0413 0.0373 0.0367 0.0366 0.0389 0.0396 0.0391 --- ---
Viscosity cP 0.0118 0.0117 0.0139 0.0138 0.0133 0.0133 0.0134 0.0125 0.0124 0.0124 0.0129 0.0130 0.0128 --- ---
Z Factor 0.9832 0.9856 0.9050 0.8829 0.8885 0.8755 0.8888 0.8255 0.8116 0.8120 0.8627 0.8750 0.8745 --- ---
Cp / Cv 1.310 1.307 1.455 1.477 1.487 1.517 1.487 1.638 1.675 1.674 1.545 1.517 1.523 --- ---
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- --- --- --- 1.59 --- --- --- --- --- 1.71
Mass Flow kg/h --- --- --- --- --- --- --- --- 120.23 --- --- --- --- --- 129.42
3
Act Volume Flow Am /h --- --- --- --- --- --- --- --- 0.18 --- --- --- --- --- 0.20
Std Liquid Flow barrel/day --- --- --- --- --- --- --- --- 28.21 --- --- --- --- --- 30.37
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- --- --- --- 2.11 --- --- --- --- --- 2.11
3
Mass Density kg/m --- --- --- --- --- --- --- --- 661.28 --- --- --- --- --- 661.41
o
Thermal Conductivity W/m. K --- --- --- --- --- --- --- --- 0.106 --- --- --- --- --- 0.106
Viscosity cP --- --- --- --- --- --- --- --- 0.40 --- --- --- --- --- 0.40
Surface Tension dynes/cm --- --- --- --- --- --- --- --- 14.57 --- --- --- --- --- 14.59
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- --- 2.43 --- --- --- --- --- --- --- 2.43 ---
Mass Flow kg/h --- --- --- --- --- 43.97 --- --- --- --- --- --- --- 43.97 ---
3
Act Volume Flow Am /h --- --- --- --- --- 0.04 --- --- --- --- --- --- --- 0.04 ---
Std Liquid Flow barrel/day --- --- --- --- --- 6.5 --- --- --- --- --- --- --- 6.5 ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- --- 4.292 --- --- --- --- --- --- --- 4.292 ---
3
Mass Density kg/m --- --- --- --- --- 1003.24 --- --- --- --- --- --- --- 1003.24 ---
o
Thermal Conductivity W/m K --- --- --- --- --- 0.6211 --- --- --- --- --- --- --- 0.6211 ---
Viscosity cP --- --- --- --- --- 0.774 --- --- --- --- --- --- --- 0.774 ---
Surface Tension dynes/cm --- --- --- --- --- 70.23 --- --- --- --- --- --- --- 70.23 ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0119 0.0119 0.0119 0.0067 0.0087 0.0087 0.0087 0.0087 0.0087 0.0087 0.0087 0.0087 0.0079 0.0000 0.0010
Oxygen 0.0000 0.0000 0.0000 0.0000 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0005 0.0008 0.0000 0.0001
CO2 0.0021 0.0021 0.0021 0.0041 0.0027 0.0027 0.0027 0.0027 0.0027 0.0027 0.0027 0.0027 0.0026 0.0001 0.0024
Methane 0.9594 0.9594 0.9594 0.9364 0.9612 0.9612 0.9623 0.9623 0.9623 0.9624 0.9624 0.9624 0.9703 0.0000 0.3125
Ethane 0.0123 0.0123 0.0123 0.0187 0.0110 0.0110 0.0110 0.0110 0.0110 0.0110 0.0110 0.0110 0.0082 0.0000 0.0172
Propane 0.0074 0.0074 0.0074 0.0171 0.0080 0.0080 0.0081 0.0081 0.0081 0.0081 0.0081 0.0081 0.0056 0.0000 0.0395
i-Butane 0.0016 0.0016 0.0016 0.0038 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018 0.0018 0.0012 0.0000 0.0194
n-Butane 0.0024 0.0024 0.0024 0.0050 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0025 0.0017 0.0000 0.0378
i-Pentane 0.0007 0.0007 0.0007 0.0018 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0008 0.0006 0.0000 0.0277
n-Pentane 0.0006 0.0006 0.0006 0.0015 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0007 0.0005 0.0000 0.0298
n-Hexane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Heptane 0.0001 0.0001 0.0001 0.0005 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0001 0.0000 0.0593
n-Octane 0.0000 0.0000 0.0000 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0447
n-Nonane 0.0000 0.0000 0.0000 0.0006 0.0002 0.0002 0.0002 0.0002 0.0002 0.0001 0.0001 0.0001 0.0001 0.0000 0.3434
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0003 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0039 0.0039 0.0032 0.0023 0.0020 0.0020 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.9996 0.0001
Total 1.0023 1.0023 1.0015 0.9988 1.0003 1.0003 0.9995 0.9995 0.9995 0.9995 0.9995 0.9995 0.9996 1.0000 0.9347
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 1: Early Production Year 2019-2020 during winter - 10.05 MMSCMD
Stream Name 159 160 161 162 203 208 210 211 212 400 401 402 403 404
TOTAL
Vapour Fraction 0.0982 0.3523 0.0000 0.1474 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 1.0000 1.0000
o
Temperature C 40.00 32.21 58.25 33.09 11.04 40.00 40.00 41.18 40.00 29.19 36.63 45.76 43.81 36.92
Pressure bar g 61.30 5.50 18.00 5.50 2.60 0.00 0.00 125.00 1.50 61.38 60.88 24.50 20.00 5.00
Molar Flow kgmol/h 1.71 1.71 0.00 4.14 52.10 128.49 128.49 128.49 49.87 358.79 358.79 358.79 87.16 271.62
Mass Flow kg/h 129.42 129.42 0.00 173.39 1219.40 2314.77 2314.77 2314.77 2361.95 6078.71 6078.71 6078.71 1476.75 4601.96
Molecular Weight kg/kmol 75.60 75.60 18.24 41.90 23.40 18.02 18.02 18.02 47.36 16.94 16.94 16.94 16.94 16.94
3
Mass Density kg/m 496.23 52.46 984.46 68.13 1058.89 995.96 995.96 998.99 1091.42 48.06 45.92 17.09 14.06 4.00
Heat Flow MW -0.09 -0.09 0.00 -0.28 -4.45 -10.17 -10.17 -10.16 -5.47 -7.66 -7.63 -7.53 -1.83 -5.70
Mass Enthalpy kJ/kg -2368.3 -2368.3 -15594.6 -5767.1 -13139.3 -15823.1 -15823.1 -15806.4 -8340.4 -4539.3 -4519.2 -4458.7 -4458.7 -4458.7
GAS PHASE
Molar flow kgmol/h 0.17 0.60 --- 0.61 --- --- --- --- --- 358.79 358.79 358.79 87.16 271.62
Mass Flow kg/h 3.02 12.90 --- 13.11 --- --- --- --- --- 6078.71 6078.71 6078.71 1476.75 4601.96
3
Act Volume Flow Am /h 0.06 2.30 --- 2.33 --- --- --- --- --- 126.48 132.37 355.66 105.02 1149.96
Std Gas Flow MMSCMD 0.00 0.00 --- 0.00 --- --- --- --- --- 0.20 0.20 0.20 0.05 0.15
Std Gas Flow MMSCFD 0.00 0.01 --- 0.01 --- --- --- --- --- 7.19 7.19 7.19 1.75 5.44
Molecular Weight kg/kmol 17.97 21.38 --- 21.48 --- --- --- --- --- 16.94 16.94 16.94 16.94 16.94
o
Mass Heat Capacity kJ/kg C 2.62 2.09 --- 2.09 --- --- --- --- --- 2.65 2.62 2.37 2.34 2.24
3
Mass Density kg/m 49.18 5.61 --- 5.62 --- --- --- --- --- 48.06 45.92 17.09 14.06 4.00
o
Thermal Conductivity W/m K 0.0403 0.0316 --- 0.0316 --- --- --- --- --- 0.0396 0.0404 0.0381 0.0374 0.0352
Viscosity cP 0.0134 0.0115 --- 0.0115 --- --- --- --- --- 0.0130 0.0132 0.0125 0.0123 0.0118
Z Factor 0.8744 0.9771 --- 0.9771 --- --- --- --- --- 0.8750 0.8866 0.9538 0.9607 0.9875
Cp / Cv 1.486 1.257 --- 1.256 --- --- --- --- --- 1.517 1.490 1.351 1.340 1.302
OIL PHASE
Molar Flow kgmol/h 1.54 1.11 --- 1.11 --- --- --- --- 49.87 --- --- --- --- ---
Mass Flow kg/h 126.40 116.52 --- 116.41 --- --- --- --- 2361.95 --- --- --- --- ---
3
Act Volume Flow Am /h 0.20 0.17 --- 0.17 --- --- --- --- 2.16 --- --- --- --- ---
Std Liquid Flow barrel/day 28.91 25.16 --- 25.13 --- --- --- --- 321.04 --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C 2.29 2.17 --- 2.17 --- --- --- --- 2.71 --- --- --- --- ---
3
Mass Density kg/m 633.95 684.02 --- 683.45 --- --- --- --- 1091.42 --- --- --- --- ---
o
Thermal Conductivity W/m. K 0.102 0.117 --- 0.117 --- --- --- --- 0.284 --- --- --- --- ---
Viscosity cP 0.29 0.43 --- 0.43 --- --- --- --- 5.53 --- --- --- --- ---
Surface Tension dynes/cm 12.99 18.32 --- 18.30 --- --- --- --- 49.14 --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- 0.00 2.42 52.10 128.49 128.49 128.49 --- --- --- --- --- ---
Mass Flow kg/h --- --- 0.00 43.87 1219.40 2314.77 2314.77 2314.77 --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- 0.00 0.04 1.15 2.32 2.32 2.32 --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- 0.0 6.5 174.4 344.3 344.3 344.3 --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- 4.297 4.299 3.701 4.316 4.316 4.301 --- --- --- --- --- ---
3
Mass Density kg/m --- --- 984.56 1002.40 1058.89 995.96 995.96 998.99 --- --- --- --- --- ---
o
Thermal Conductivity W/m K --- --- 0.6444 0.6193 0.4609 0.6315 0.6315 0.6330 --- --- --- --- --- ---
Viscosity cP --- --- 0.525 0.793 2.349 0.651 0.651 0.637 --- --- --- --- --- ---
Surface Tension dynes/cm --- --- 65.85 70.48 65.43 69.49 69.49 69.29 --- --- --- --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0010 0.0010 0.0000 0.0004 0.0000 0.0000 0.0000 0.0000 0.0000 0.0087 0.0087 0.0087 0.0087 0.0087
Oxygen 0.0001 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0005 0.0005 0.0005 0.0005 0.0005
CO2 0.0024 0.0024 0.0000 0.0010 0.0000 0.0000 0.0000 0.0000 0.0008 0.0027 0.0027 0.0027 0.0027 0.0027
Methane 0.3125 0.3125 0.0000 0.1292 0.0000 0.0000 0.0000 0.0000 0.0000 0.9624 0.9624 0.9624 0.9624 0.9624
Ethane 0.0172 0.0172 0.0000 0.0071 0.0000 0.0000 0.0000 0.0000 0.0000 0.0110 0.0110 0.0110 0.0110 0.0110
Propane 0.0395 0.0395 0.0000 0.0163 0.0000 0.0000 0.0000 0.0000 0.0000 0.0081 0.0081 0.0081 0.0081 0.0081
i-Butane 0.0194 0.0194 0.0000 0.0080 0.0000 0.0000 0.0000 0.0000 0.0000 0.0018 0.0018 0.0018 0.0018 0.0018
n-Butane 0.0378 0.0378 0.0000 0.0156 0.0000 0.0000 0.0000 0.0000 0.0000 0.0025 0.0025 0.0025 0.0025 0.0025
i-Pentane 0.0277 0.0277 0.0000 0.0115 0.0000 0.0000 0.0000 0.0000 0.0000 0.0008 0.0008 0.0008 0.0008 0.0008
n-Pentane 0.0298 0.0298 0.0000 0.0123 0.0000 0.0000 0.0000 0.0000 0.0000 0.0007 0.0007 0.0007 0.0007 0.0007
n-Hexane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Heptane 0.0593 0.0593 0.0000 0.0054 0.0000 0.0000 0.0000 0.0000 0.0000 0.0002 0.0002 0.0002 0.0002 0.0002
n-Octane 0.0447 0.0447 0.0000 0.0041 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Nonane 0.3434 0.3434 0.0000 0.0313 0.0000 0.0000 0.0000 0.0000 0.0000 0.0001 0.0001 0.0001 0.0001 0.0001
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0050 0.0013 0.1265 0.0000 0.0000 0.0000 0.6685 0.0000 0.0000 0.0000 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0001 0.0001 0.9949 0.9074 0.8735 1.0000 1.0000 1.0000 0.3307 0.0001 0.0001 0.0001 0.0001 0.0001
Total 0.9347 0.9347 1.0000 1.1511 1.0000 1.0000 1.0000 1.0000 1.0000 0.9995 0.9995 0.9995 0.9995 0.9995
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 2: Production Year 2022-2023 - 7 MMSCMD
Stream Name U-1 Sat U-3 Sat U_MEG Injection U_Produced Water U_100A U_100 U_101 U_102 U_103 U_132 U_140 U_141 U_203 U_400 U_401
TOTAL
Vapour Fraction 1.0000 1.0000 0.0000 0.0000 0.9502 --- --- --- --- --- --- --- --- 1.0000 1.0000
o
Temperature C 19.00 19.00 19.00 19.00 19.00 --- --- --- --- --- --- --- --- 40.34 45.75
Pressure bar g 25.00 25.00 25.00 25.00 25.00 --- --- --- --- --- --- --- --- 61.38 60.88
Molar Flow kgmol/h 4775.6 4846.1 142.4 359.7 10123.8 --- --- --- --- --- --- --- --- 499.0 499.0
Mass Flow kg/h 77293.5 78928.1 7102.3 6480.0 169803.9 --- --- --- --- --- --- --- --- 8327.8 8327.8
Molecular Weight kg/kmol 16.19 16.29 49.87 18.02 16.77 --- --- --- --- --- --- --- --- 16.69 16.69
3
Mass Density kg/m 18.42 18.53 1111.09 1012.56 20.05 --- --- --- --- --- --- --- --- 44.68 43.21
Heat Flow MW -100.61 -102.31 -16.11 -28.64 -247.64 --- --- --- --- --- --- --- --- -10.57 -10.54
Mass Enthalpy kJ/kg -4686.1 -4666.5 -8163.3 -15911.3 -5250.2 --- --- --- --- --- --- --- --- -4570.1 -4555.4
GAS PHASE
Molar flow kgmol/h 4775.61 4846.10 --- --- 9620.07 --- --- --- --- --- --- --- --- 499.02 499.02
Mass Flow kg/h 77293.49 78928.06 --- --- 156190.88 --- --- --- --- --- --- --- --- 8327.83 8327.83
3
Act Volume Flow Am /h 4196.84 4259.83 --- --- 8455.28 --- --- --- --- --- --- --- --- 186.40 192.71
Std Gas Flow MMSCMD 2.71 2.75 --- --- 5.46 --- --- --- --- --- --- --- --- 0.28 0.28
Std Gas Flow MMSCFD 95.70 97.12 --- --- 192.79 --- --- --- --- --- --- --- --- 10.00 10.00
Molecular Weight kg/kmol 16.19 16.29 --- --- 16.24 --- --- --- --- --- --- --- --- 16.69 16.69
o
Mass Heat Capacity kJ/kg C 2.39 2.37 --- --- 2.38 --- --- --- --- --- --- --- --- 2.63 2.62
3
Mass Density kg/m 18.42 18.53 --- --- 18.47 --- --- --- --- --- --- --- --- 44.68 43.21
o
Thermal Conductivity W/m K 0.0350 0.0349 --- --- 0.0349 --- --- --- --- --- --- --- --- 0.0411 0.0417
Viscosity cP 0.0116 0.0116 --- --- 0.0116 --- --- --- --- --- --- --- --- 0.0133 0.0134
Z Factor 0.9411 0.9414 --- --- 0.9413 --- --- --- --- --- --- --- --- 0.8942 0.9015
Cp / Cv 1.393 1.393 --- --- 1.393 --- --- --- --- --- --- --- --- 1.481 1.465
OIL PHASE
Molar Flow kgmol/h --- --- 142.41 --- --- --- --- --- --- --- --- --- --- --- ---
Mass Flow kg/h --- --- 7102.34 --- --- --- --- --- --- --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- 6.39 --- --- --- --- --- --- --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- 963.92 --- --- --- --- --- --- --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C --- --- 2.57 --- --- --- --- --- --- --- --- --- --- --- ---
3
Mass Density kg/m --- --- 1111.09 --- --- --- --- --- --- --- --- --- --- --- ---
o
Thermal Conductivity W/m. K --- --- 0.2728 --- --- --- --- --- --- --- --- --- --- --- ---
Viscosity cP --- --- 11.65 --- --- --- --- --- --- --- --- --- --- --- ---
Surface Tension dynes/cm --- --- 50.65 --- --- --- --- --- --- --- --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- 359.70 503.75 --- --- --- --- --- --- --- --- --- ---
Mass Flow kg/h --- --- --- 6480.05 13613.05 --- --- --- --- --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- --- 6.40 12.71 --- --- --- --- --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- --- 963.92 1915.08 --- --- --- --- --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- --- 4.31 3.43 --- --- --- --- --- --- --- --- --- ---
3
Mass Density kg/m --- --- --- 1012.56 1070.99 --- --- --- --- --- --- --- --- --- ---
o
Thermal Conductivity W/m K --- --- --- 0.6018 0.4112 --- --- --- --- --- --- --- --- --- ---
Viscosity cP --- --- --- 1.027 2.752 --- --- --- --- --- --- --- --- --- ---
Surface Tension dynes/cm --- --- --- 73.13 60.62 --- --- --- --- --- --- --- --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0043 0.0081 0.0000 0.0000 0.0059 --- --- --- --- --- --- --- --- 0.0066 0.0066
Oxygen 0.0012 0.0021 0.0000 0.0000 0.0015 --- --- --- --- --- --- --- --- 0.0011 0.0011
CO2 0.0015 0.0031 0.0000 0.0000 0.0022 --- --- --- --- --- --- --- --- 0.0028 0.0028
Methane 0.9901 0.9843 0.0000 0.0000 0.9382 --- --- --- --- --- --- --- --- 0.9731 0.9731
Ethane 0.0020 0.0012 0.0000 0.0000 0.0015 --- --- --- --- --- --- --- --- 0.0068 0.0068
Propane 0.0000 0.0003 0.0000 0.0000 0.0001 --- --- --- --- --- --- --- --- 0.0051 0.0051
i-Butane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0012 0.0012
n-Butane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0016 0.0016
i-Pentane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0006 0.0006
n-Pentane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0004 0.0004
n-Hexane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0003 0.0003
n-Heptane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0002 0.0002
n-Octane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0000 0.0000
n-Nonane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0002 0.0002
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0000 0.0000
EGlycol 0.0000 0.0000 0.7232 0.0000 0.0102 --- --- --- --- --- --- --- --- 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 --- --- --- --- --- --- --- --- 0.0000 0.0000
H2O 0.0009 0.0009 0.2768 1.0000 0.0403 --- --- --- --- --- --- --- --- 0.0001 0.0001
Total 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 2: Production Year 2022-2023 - 7 MMSCMD
VA_Produced
Stream Name U_402 U_403 U_404 S-2 Sat VA-1A Sat VA-2 Sat VA_MEG injection 100A 100 101 103 108 109 110
Water
Fuel Gas (U Field) Fuel Gas (U Field) Fuel Gas (U Field) Produced Water Total Vashishta Vashishta Field Gas from Gas/Gas
Production Fluid Production Fluid Production Fluid MEG Injection for Gas from Slug Rich MEG from Gas from Inlet Gas to Existing
Description from New FG Hot to New Generator to distribution for from Vashishta Field Production Production Fluid Exchanger Pass
from S-2 Field from VA-1A Field from VA-2 Field Vashishta Field Catcher Slug Catcher Scrubber Compressors
Oil Heater Gas Turbine new facilities Field Fluid to Slug Catcher 'A'
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000 0.9461 0.9494 1.0000 0.0000 1.0000 1.0000 1.0000
o
Temperature C 49.10 47.22 40.58 30.00 30.00 30.00 30.00 30.00 30.00 15.82 15.71 15.71 15.02 35.00 35.00
Pressure bar g 24.50 20.00 5.00 9.00 9.00 9.00 9.00 9.00 9.00 9.00 8.80 8.80 7.50 7.00 7.00
Molar Flow kgmol/h 499.0 99.8 399.2 881.1 969.2 881.1 28.4 125.9 2885.7 13009.6 12351.6 658.0 12351.6 12351.6 2121.8
Mass Flow kg/h 8327.8 1665.6 6662.3 14863.3 16556.7 14852.9 1416.9 2267.9 49957.8 219761.7 202466.5 17295.2 202466.5 202466.5 34780.1
Molecular Weight kg/kmol 16.69 16.69 16.69 16.87 17.08 16.86 49.87 18.02 17.31 16.89 16.39 26.29 16.39 16.39 16.39
3
Mass Density kg/m 16.61 13.67 3.89 6.85 6.94 6.85 1101.54 1003.84 7.43 7.60 6.86 1069.78 5.95 5.21 5.21
Heat Flow MW -10.44 -2.09 -8.35 -18.61 -20.60 -18.60 -3.20 -9.99 -71.01 -318.65 -260.54 -58.11 -260.54 -257.97 -44.31
Mass Enthalpy kJ/kg -4511.3 -4511.3 -4511.3 -4508.0 -4479.2 -4507.0 -8136.5 -15865.4 -5117.0 -5219.9 -4632.6 -12096.1 -4632.6 -4586.9 -4586.9
GAS PHASE
Molar flow kgmol/h 499.02 99.80 399.21 881.11 969.22 881.11 --- --- 2730.08 12351.36 12351.59 --- 12351.59 12351.59 2121.78
Mass Flow kg/h 8327.83 1665.57 6662.27 14863.32 16556.71 14852.94 --- --- 46248.90 202462.31 202466.50 --- 202466.50 202466.50 34780.11
3
Act Volume Flow Am /h 501.42 121.87 1711.55 2169.02 2384.43 2169.11 --- --- 6719.26 28909.21 29501.17 --- 34029.30 38865.05 6676.32
Std Gas Flow MMSCMD 0.28 0.06 0.23 0.50 0.55 0.50 --- --- 1.55 7.01 7.01 --- 7.01 7.01 1.20
Std Gas Flow MMSCFD 10.00 2.00 8.00 17.66 19.42 17.66 --- --- 54.71 247.52 247.52 --- 247.52 247.52 42.52
Molecular Weight kg/kmol 16.69 16.69 16.69 16.87 17.08 16.86 --- --- 16.94 16.39 16.39 --- 16.39 16.39 16.39
o
Mass Heat Capacity kJ/kg C 2.39 2.36 2.26 2.25 2.24 2.25 --- --- 2.25 2.25 2.25 --- 2.24 2.27 2.27
3
Mass Density kg/m 16.61 13.67 3.89 6.85 6.94 6.85 --- --- 6.88 7.00 6.86 --- 5.95 5.21 5.21
o
Thermal Conductivity W/m K 0.0387 0.0381 0.0359 0.0345 0.0344 0.0345 --- --- 0.0344 0.0329 0.0328 --- 0.0326 0.0355 0.0355
Viscosity cP 0.0126 0.0124 0.0119 0.0116 0.0116 0.0116 --- --- 0.0116 0.0112 0.0112 --- 0.0111 0.0118 0.0118
Z Factor 0.9568 0.9633 0.9883 0.9780 0.9774 0.9780 --- --- 0.9778 0.9755 0.9759 --- 0.9789 0.9841 0.9841
Cp / Cv 1.350 1.340 1.303 1.321 1.317 1.321 --- --- 1.319 1.336 1.335 --- 1.331 1.317 1.317
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- --- 28.41 --- --- --- --- --- --- --- ---
Mass Flow kg/h --- --- --- --- --- --- 1416.86 --- --- --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- --- 1.29 --- --- --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- --- 192.30 --- --- --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- --- 2.62 --- --- --- --- --- --- --- ---
3
Mass Density kg/m --- --- --- --- --- --- 1101.54 --- --- --- --- --- --- --- ---
o
Thermal Conductivity W/m. K --- --- --- --- --- --- 0.2756 --- --- --- --- --- --- --- ---
Viscosity cP --- --- --- --- --- --- 8.84 --- --- --- --- --- --- --- ---
Surface Tension dynes/cm --- --- --- --- --- --- 49.59 --- --- --- --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- --- --- --- 125.89 155.66 658.20 --- 657.97 --- --- ---
Mass Flow kg/h --- --- --- --- --- --- --- 2267.93 3708.85 17299.38 --- 17295.19 --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- --- --- 2.26 3.54 16.17 --- 16.17 --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- --- --- 337.36 529.14 2440.70 --- 2440.08 --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- --- --- --- 4.31 3.69 3.48 --- 3.48 --- --- ---
3
Mass Density kg/m --- --- --- --- --- --- --- 1003.84 1046.64 1069.69 --- 1069.78 --- --- ---
o
Thermal Conductivity W/m K --- --- --- --- --- --- --- 0.6182 0.4725 0.4188 --- 0.4186 --- --- ---
Viscosity cP --- --- --- --- --- --- --- 0.797 1.579 2.789 --- 2.798 --- --- ---
Surface Tension dynes/cm --- --- --- --- --- --- --- 71.23 62.27 61.70 --- 61.71 --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0066 0.0066 0.0066 0.0119 0.0106 0.0122 0.0000 0.0000 0.0109 0.0070 0.0074 0.0000 0.0074 0.0074 0.0074
Oxygen 0.0011 0.0011 0.0011 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0012 0.0013 0.0000 0.0013 0.0013 0.0013
CO2 0.0028 0.0028 0.0028 0.0021 0.0023 0.0020 0.0000 0.0000 0.0020 0.0022 0.0023 0.0000 0.0023 0.0023 0.0023
Methane 0.9731 0.9731 0.9731 0.9568 0.9537 0.9570 0.0000 0.0000 0.9047 0.9308 0.9804 0.0000 0.9804 0.9804 0.9804
Ethane 0.0068 0.0068 0.0068 0.0124 0.0119 0.0123 0.0000 0.0000 0.0116 0.0037 0.0039 0.0000 0.0039 0.0039 0.0039
Propane 0.0051 0.0051 0.0051 0.0075 0.0072 0.0074 0.0000 0.0000 0.0069 0.0017 0.0017 0.0000 0.0017 0.0017 0.0017
i-Butane 0.0012 0.0012 0.0012 0.0014 0.0027 0.0013 0.0000 0.0000 0.0017 0.0004 0.0004 0.0000 0.0004 0.0004 0.0004
n-Butane 0.0016 0.0016 0.0016 0.0020 0.0046 0.0019 0.0000 0.0000 0.0027 0.0006 0.0006 0.0000 0.0006 0.0006 0.0006
i-Pentane 0.0006 0.0006 0.0006 0.0006 0.0011 0.0006 0.0000 0.0000 0.0007 0.0002 0.0002 0.0000 0.0002 0.0002 0.0002
n-Pentane 0.0004 0.0004 0.0004 0.0005 0.0008 0.0005 0.0000 0.0000 0.0006 0.0001 0.0001 0.0000 0.0001 0.0001 0.0001
n-Hexane 0.0003 0.0003 0.0003 0.0004 0.0005 0.0004 0.0000 0.0000 0.0004 0.0001 0.0001 0.0000 0.0001 0.0001 0.0001
n-Heptane 0.0002 0.0002 0.0002 0.0000 0.0003 0.0000 0.0000 0.0000 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Octane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Nonane 0.0002 0.0002 0.0002 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.7232 0.0000 0.0071 0.0095 0.0000 0.1877 0.0000 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0001 0.0001 0.0001 0.0043 0.0043 0.0043 0.2768 1.0000 0.0505 0.0426 0.0016 0.8122 0.0016 0.0016 0.0016
Total 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 2: Production Year 2022-2023 - 7 MMSCMD
Stream Name 111 112 127 128 130 132 136 137 138 139 139A 140 141 157 158
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 1.0000 0.9993 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 0.0000 0.0000
o
Temperature C 35.00 34.44 57.20 50.00 55.00 34.30 41.60 5.00 -1.50 -1.65 19.51 40.34 39.84 34.30 -1.65
Pressure bar g 7.00 5.80 67.50 67.50 67.20 66.10 64.10 63.30 62.60 62.30 61.98 61.38 60.08 66.10 62.30
Molar Flow kgmol/h 10229.8 2121.8 10229.8 3882.4 14112.2 14112.2 14088.5 14088.5 14088.5 14088.1 14088.1 14088.1 13230.3 10.2 0.4
Mass Flow kg/h 167686.4 34780.1 167686.4 67881.7 235568.1 235568.1 235139.7 235139.7 235139.7 235109.5 235109.5 235109.5 220794.1 184.8 30.2
Molecular Weight kg/kmol 16.39 16.39 16.39 17.48 16.69 16.69 16.69 16.69 16.69 16.69 16.69 16.69 16.69 18.09 81.03
3
Mass Density kg/m 5.21 4.43 44.89 50.29 46.13 49.89 46.55 55.86 57.51 57.24 50.11 44.68 43.76 1003.14 675.59
Heat Flow MW -213.66 -44.31 -213.85 -84.06 -297.91 -301.56 -298.44 -304.83 -305.96 -305.94 -302.11 -298.46 -280.29 -0.81 -0.02
Mass Enthalpy kJ/kg -4586.9 -4586.9 -4591.1 -4458.1 -4552.7 -4608.6 -4569.1 -4667.0 -4684.2 -4684.5 -4626.0 -4570.1 -4570.1 -15788.5 -2422.3
GAS PHASE
Molar flow kgmol/h 10229.81 2121.78 10229.81 3882.44 14112.25 14102.04 14088.51 14088.51 14088.25 14088.14 14088.14 14088.14 13230.34 --- ---
Mass Flow kg/h 167686.39 34780.11 167686.39 67881.72 235568.11 235383.34 235139.72 235139.72 235118.05 235109.52 235109.52 235109.52 220794.12 --- ---
3
Act Volume Flow Am /h 32188.73 7855.95 3735.36 1349.91 5106.54 4722.00 5051.37 4209.37 4088.32 4107.34 4691.69 5262.28 5045.55 --- ---
Std Gas Flow MMSCMD 5.81 1.20 5.81 2.20 8.01 8.00 7.99 7.99 7.99 7.99 7.99 7.99 7.51 --- ---
Std Gas Flow MMSCFD 205.00 42.52 205.00 77.80 282.81 282.60 282.33 282.33 282.33 282.32 282.32 282.32 265.13 --- ---
Molecular Weight kg/kmol 16.39 16.39 16.39 17.48 16.69 16.69 16.69 16.69 16.69 16.69 16.69 16.69 16.69 --- ---
o
Mass Heat Capacity kJ/kg C 2.27 2.27 2.65 2.65 2.65 2.68 2.65 2.78 2.82 2.82 2.69 2.63 2.62 --- ---
3
Mass Density kg/m 5.21 4.43 44.89 50.29 46.13 49.85 46.55 55.86 57.51 57.24 50.11 44.68 43.76 --- ---
o
Thermal Conductivity W/m K 0.0355 0.0353 0.0439 0.0424 0.0434 0.0409 0.0415 0.0375 0.0368 0.0367 0.0387 0.0411 0.0409 --- ---
Viscosity cP 0.0118 0.0117 0.0138 0.0138 0.0138 0.0133 0.0134 0.0125 0.0123 0.0123 0.0128 0.0133 0.0132 --- ---
Z Factor 0.9841 0.9864 0.9108 0.8866 0.9047 0.8791 0.8921 0.8309 0.8173 0.8177 0.8621 0.8942 0.8953 --- ---
Cp / Cv 1.317 1.314 1.456 1.476 1.460 1.516 1.486 1.632 1.667 1.666 1.554 1.481 1.478 --- ---
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- --- --- --- 0.27 --- --- --- --- --- 0.37
Mass Flow kg/h --- --- --- --- --- --- --- --- 21.68 --- --- --- --- --- 30.20
3
Act Volume Flow Am /h --- --- --- --- --- --- --- --- 0.03 --- --- --- --- --- 0.04
Std Liquid Flow barrel/day --- --- --- --- --- --- --- --- 4.97 --- --- --- --- --- 6.93
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- --- --- --- 2.08 --- --- --- --- --- 2.08
3
Mass Density kg/m --- --- --- --- --- --- --- --- 675.40 --- --- --- --- --- 675.59
o
Thermal Conductivity W/m. K --- --- --- --- --- --- --- --- 0.1084 --- --- --- --- --- 0.1084
Viscosity cP --- --- --- --- --- --- --- --- 0.46 --- --- --- --- --- 0.46
Surface Tension dynes/cm --- --- --- --- --- --- --- --- 15.41 --- --- --- --- --- 15.43
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- --- 10.21 --- --- --- --- --- --- --- 10.21 ---
Mass Flow kg/h --- --- --- --- --- 184.78 --- --- --- --- --- --- --- 184.78 ---
3
Act Volume Flow Am /h --- --- --- --- --- 0.18 --- --- --- --- --- --- --- 0.18 ---
Std Liquid Flow barrel/day --- --- --- --- --- 27.46 --- --- --- --- --- --- --- 27.46 ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- --- 4.30 --- --- --- --- --- --- --- 4.30 ---
3
Mass Density kg/m --- --- --- --- --- 1003.14 --- --- --- --- --- --- --- 1003.14 ---
o
Thermal Conductivity W/m K --- --- --- --- --- 0.6216 --- --- --- --- --- --- --- 0.6216 ---
Viscosity cP --- --- --- --- --- 0.774 --- --- --- --- --- --- --- 0.774 ---
Surface Tension dynes/cm --- --- --- --- --- 70.32 --- --- --- --- --- --- --- 70.32 ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0074 0.0074 0.0074 0.0043 0.0065 0.0065 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0066 0.0000 0.0007
Oxygen 0.0013 0.0013 0.0013 0.0007 0.0011 0.0011 0.0011 0.0011 0.0011 0.0011 0.0011 0.0011 0.0011 0.0000 0.0003
CO2 0.0023 0.0023 0.0023 0.0042 0.0028 0.0028 0.0028 0.0028 0.0028 0.0028 0.0028 0.0028 0.0028 0.0001 0.0025
Methane 0.9804 0.9804 0.9804 0.9480 0.9714 0.9714 0.9731 0.9731 0.9731 0.9731 0.9731 0.9731 0.9731 0.0000 0.3097
Ethane 0.0039 0.0039 0.0039 0.0142 0.0068 0.0068 0.0068 0.0068 0.0068 0.0068 0.0068 0.0068 0.0068 0.0000 0.0104
Propane 0.0017 0.0017 0.0017 0.0140 0.0051 0.0051 0.0051 0.0051 0.0051 0.0051 0.0051 0.0051 0.0051 0.0000 0.0251
i-Butane 0.0004 0.0004 0.0004 0.0032 0.0012 0.0012 0.0012 0.0012 0.0012 0.0012 0.0012 0.0012 0.0012 0.0000 0.0129
n-Butane 0.0006 0.0006 0.0006 0.0041 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0016 0.0000 0.0245
i-Pentane 0.0002 0.0002 0.0002 0.0015 0.0005 0.0005 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0006 0.0000 0.0190
n-Pentane 0.0001 0.0001 0.0001 0.0013 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0004 0.0000 0.0204
n-Hexane 0.0001 0.0001 0.0001 0.0010 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0003 0.0000 0.0456
n-Heptane 0.0000 0.0000 0.0000 0.0005 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0000 0.0568
n-Octane 0.0000 0.0000 0.0000 0.0002 0.0001 0.0001 0.0001 0.0001 0.0001 0.0000 0.0000 0.0000 0.0000 0.0000 0.0484
n-Nonane 0.0000 0.0000 0.0000 0.0006 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0002 0.0000 0.4236
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0018 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0016 0.0016 0.0016 0.0023 0.0018 0.0018 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.0001 0.9982 0.0001
Total 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
Project: KG DWN 98/2 Project Development Onshore MEG & Gas Pipeline Terminal (OMF)
Case 2: Production Year 2022-2023 - 7 MMSCMD
Stream Name 159 160 161 162 203 208 210 211 212 400 401 402 403 404
TOTAL
Vapour Fraction 0.0918 0.3284 0.0000 0.0117 0.0000 0.0000 0.0000 0.0000 0.0000 1.0000 1.0000 1.0000 1.0000 1.0000
o
Temperature C 40.00 34.60 58.25 35.47 15.88 40.00 40.00 41.18 40.00 40.34 47.95 58.68 56.91 50.68
Pressure bar g 61.30 5.50 18.00 5.50 2.60 0.00 0.00 125.00 1.50 61.38 60.88 24.50 20.00 5.00
Molar Flow kgmol/h 0.4 0.4 0.0 10.6 658.0 473.2 473.2 473.2 184.8 358.8 358.8 358.8 87.2 271.6
Mass Flow kg/h 30.2 30.2 0.0 215.0 17295.2 8524.6 8524.6 8524.6 8770.6 5987.6 5987.6 5987.6 1454.6 4533.0
Molecular Weight kg/kmol 81.03 81.03 18.37 20.31 26.29 18.02 18.02 18.02 47.47 16.69 16.69 16.69 16.69 16.69
3
Mass Density kg/m 517.91 59.00 985.64 304.93 1069.07 995.96 995.96 998.99 1091.53 44.68 42.80 16.05 13.21 3.77
Heat Flow MW -0.02 -0.02 0.00 -0.83 -58.11 -37.47 -37.47 -37.43 -20.30 -7.60 -7.57 -7.46 -1.81 -5.65
Mass Enthalpy kJ/kg -2328.0 -2328.0 -15511.4 -13897.6 -12096.1 -15823.1 -15823.1 -15806.4 -8330.7 -4570.1 -4549.6 -4488.3 -4488.3 -4488.3
GAS PHASE
Molar flow kgmol/h 0.03 0.12 --- 0.12 --- --- --- --- --- 358.79 358.79 358.79 87.16 271.62
Mass Flow kg/h 0.60 2.44 --- 2.49 --- --- --- --- --- 5987.58 5987.58 5987.58 1454.61 4532.97
3
Act Volume Flow Am /h 0.01 0.47 --- 0.48 --- --- --- --- --- 134.02 139.91 372.94 110.08 1203.49
Std Gas Flow MMSCMD 0.00 0.00 --- 0.00 --- --- --- --- --- 0.20 0.20 0.20 0.05 0.15
Std Gas Flow MMSCFD 0.00 0.00 --- 0.00 --- --- --- --- --- 7.19 7.19 7.19 1.75 5.44
Molecular Weight kg/kmol 17.41 19.90 --- 20.04 --- --- --- --- --- 16.69 16.69 16.69 16.69 16.69
o
Mass Heat Capacity kJ/kg C 2.62 2.14 --- 2.13 --- --- --- --- --- 2.63 2.62 2.41 2.38 2.29
3
Mass Density kg/m 47.20 5.17 --- 5.19 --- --- --- --- --- 44.68 42.80 16.05 13.21 3.77
o
Thermal Conductivity W/m K 0.0406 0.0329 --- 0.0329 --- --- --- --- --- 0.0411 0.0419 0.0401 0.0395 0.0374
Viscosity cP 0.0133 0.0117 --- 0.0117 --- --- --- --- --- 0.0133 0.0134 0.0128 0.0127 0.0122
Z Factor 0.8829 0.9807 --- 0.9807 --- --- --- --- --- 0.8942 0.9040 0.9612 0.9671 0.9896
Cp / Cv 1.483 1.270 --- 1.269 --- --- --- --- --- 1.481 1.459 1.340 1.330 1.298
OIL PHASE
Molar Flow kgmol/h 0.34 0.25 --- 0.25 --- --- --- --- 184.78 --- --- --- --- ---
Mass Flow kg/h 29.60 27.76 --- 27.75 --- --- --- --- 8770.58 --- --- --- --- ---
3
Act Volume Flow Am /h 0.05 0.04 --- 0.04 --- --- --- --- 8.04 --- --- --- --- ---
Std Liquid Flow barrel/day 6.64 5.93 --- 5.93 --- --- --- --- 1192.01 --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C 2.26 2.17 --- 2.17 --- --- --- --- 2.71 --- --- --- --- ---
3
Mass Density kg/m 647.94 690.08 --- 689.53 --- --- --- --- 1091.53 --- --- --- --- ---
o
Thermal Conductivity W/m. K 0.1045 0.1192 --- 0.1192 --- --- --- --- 0.2845 --- --- --- --- ---
Viscosity cP 0.32 0.46 --- 0.46 --- --- --- --- 5.57 --- --- --- --- ---
Surface Tension dynes/cm 13.88 18.96 --- 18.93 --- --- --- --- 49.14 --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- 0.00 10.21 657.97 473.19 473.19 473.19 --- --- --- --- --- ---
Mass Flow kg/h --- --- 0.00 184.74 17295.18 8524.61 8524.61 8524.61 --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- 0.00 0.18 16.17 8.56 8.56 8.53 --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- 0.00 27.46 2440.08 1268.06 1268.06 1268.06 --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg C --- --- 4.28 4.30 3.48 4.32 4.32 4.30 --- --- --- --- --- ---
3
Mass Density kg/m --- --- 985.75 1000.35 1069.38 995.96 995.96 998.99 --- --- --- --- --- ---
o
Thermal Conductivity W/m K --- --- 0.6402 0.6232 0.4188 0.6315 0.6315 0.6330 --- --- --- --- --- ---
Viscosity cP --- --- 0.533 0.757 2.785 0.651 0.651 0.637 --- --- --- --- --- ---
Surface Tension dynes/cm --- --- 65.62 70.12 61.69 69.49 69.49 69.29 --- --- --- --- --- ---
COMPOSITION (Mole Fraction)
Nitrogen 0.0007 0.0007 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0066 0.0066 0.0066 0.0066 0.0066
Oxygen 0.0003 0.0003 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0011 0.0011 0.0011 0.0011 0.0011
CO2 0.0025 0.0025 0.0000 0.0001 0.0000 0.0000 0.0000 0.0000 0.0002 0.0028 0.0028 0.0028 0.0028 0.0028
Methane 0.3097 0.3097 0.0000 0.0109 0.0000 0.0000 0.0000 0.0000 0.0000 0.9731 0.9731 0.9731 0.9731 0.9731
Ethane 0.0104 0.0104 0.0000 0.0004 0.0000 0.0000 0.0000 0.0000 0.0000 0.0068 0.0068 0.0068 0.0068 0.0068
Propane 0.0251 0.0251 0.0000 0.0009 0.0000 0.0000 0.0000 0.0000 0.0000 0.0051 0.0051 0.0051 0.0051 0.0051
i-Butane 0.0129 0.0129 0.0000 0.0005 0.0000 0.0000 0.0000 0.0000 0.0000 0.0012 0.0012 0.0012 0.0012 0.0012
n-Butane 0.0245 0.0245 0.0000 0.0009 0.0000 0.0000 0.0000 0.0000 0.0000 0.0016 0.0016 0.0016 0.0016 0.0016
i-Pentane 0.0190 0.0190 0.0000 0.0007 0.0000 0.0000 0.0000 0.0000 0.0000 0.0006 0.0006 0.0006 0.0006 0.0006
n-Pentane 0.0204 0.0204 0.0000 0.0007 0.0000 0.0000 0.0000 0.0000 0.0000 0.0004 0.0004 0.0004 0.0004 0.0004
n-Hexane 0.0456 0.0456 0.0000 0.0016 0.0000 0.0000 0.0000 0.0000 0.0000 0.0003 0.0003 0.0003 0.0003 0.0003
n-Heptane 0.0568 0.0568 0.0000 0.0020 0.0000 0.0000 0.0000 0.0000 0.0000 0.0002 0.0002 0.0002 0.0002 0.0002
n-Octane 0.0484 0.0484 0.0000 0.0017 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
n-Nonane 0.4236 0.4236 0.0000 0.0149 0.0000 0.0000 0.0000 0.0000 0.0000 0.0002 0.0002 0.0002 0.0002 0.0002
n-Decane 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
EGlycol 0.0000 0.0000 0.0079 0.0017 0.1877 0.0000 0.0000 0.0000 0.6684 0.0000 0.0000 0.0000 0.0000 0.0000
TEGlycol 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
H2O 0.0001 0.0001 0.9920 0.9630 0.8122 1.0000 1.0000 1.0000 0.3314 0.0001 0.0001 0.0001 0.0001 0.0001
Total 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000 1.0000
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 53 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0A
Drawings List
Page 54 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0A
Page 55 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 56 of 74
Calculation Cover Sheet
Calculation Method
Vessel, nozzle and line sizing calculations were performed using inhouse sizing spreadsheets.
Assumptions
1. 10% design margin on production fluid of 10 MMSCMD
2. 20m3 slug volume on each vessel based on MEG draw out rate of 168 m3/day
3. The properties of stream U_100 for HMB Case 1 (Production Year 2019 - 2020) is used in the sizing of HP Separators.
4. HP Separator is not equipped with internals.
Software Used
Title Version Validation (Y / N / N/A)
SeleXpress 3.2.1.92 Y
References
1. 402020-01391-02-SY-REP-0002- Flow Assurance Report- Cluster 2B Gas Fields
2. OMF Bid Addendum 001 Technical - 0E
3. 402020-01391-01-SY-BOD-0001-0G Overall Design Basis
Conclusions
Vessel Size Nozzle and Line Size
Vessel ID = 3000 mm Inlet header size = 14"
Vessel T/T = 6000 mm Mixed phase inlet nozzle size = 16"
Vessel Weight = 99 te Mixed phase inlet line size = 10"
Operating Weight = 116 te Gas outlet nozzle size = 12"
Gas outlet line size = 10"
Liquid outlet nozzle size = 2"
Liquid outlet line size = 2"
Table of Contents
Objective 4
Method 4
Assumptions 4
Fluid Properties and Details 5
Nozzle Sizing 6
Vessel Height Determination 7
Vessel Weight Calculation 7
Vessel Sketch 10
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Method:
Vessel, nozzle and line sizing calculations were performed using inhouse sizing spreadsheets.
Assumptions:
1. 10% design margin on production fluid of 10 MMSCMD
2. 20m3 slug volume on each vessel based on MEG draw out rate of 168 m3/day
3. The properties of stream U_100 for HMB Case 1 (Production Year 2019 - 2020) is used in the sizing of HP Separators.
4. HP Separator is not equipped with internals.
Conclusion:
Vessel Size Nozzle Size
Vessel ID = 3000 mm Mixed phase inlet nozzle size = 16"
Vessel T/T = 6000 mm Gas outlet nozzle size = 10"
L/D = 2 Liquid outlet nozzle size = 2"
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Gas Outlet:
Gas Outlet Stream = U_101
Operating Pressure = 6400.0 kPag
Design Pressure = 8000.0 kPag Manual entry
Operating Temperature = 11.0 °C
Design Temperature = 65.0 °C
Standard Gas Flow = 137500.0 Sm³/h
Gas Volumetric Rate = 1799.4 Am³/h
Gas Density (ρg) = 52.46 kg/m³
Gas Mass Rate = 26.2 kg/s
Gas viscosity = 0.013 cP
Gas Rate (Qg) = 0.50 m³/s
Liquid Outlet:
Liquid Outlet Stream = U_103
Hydrocarbon phase mass rate = 0.0 kg/s
Hydrocarbon phase density = 650.0 kg/m³
Hydrocarbon phase viscosity = 0.00 cP
Hydrocarbon phase surface tension = 0.00 N/m
Light phase volumetric rate = 0 m3/h
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
= 1080.4 kg/m³
Calculated Values:
Volume fraction light liquid = 0.01
Nozzle Sizing:
Inlet nozzle:
Maximum ρv2 = 1400 kg/m.s²
Minimum size inlet nozzle (ID) = 352.91 mm
Selected inlet nozzle (NB) = 400.00 mm Manual entry
Nozzle schedule = 80
Nozzle ID = 363.52 mm
Nozzle velocity = 4.82 m/s
Calculated ρv2 = 1244 kg/m.s²
Nozzle size check: OK
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Vessel Sizing:
Vessel type selected = Knockout Drum (H)
K factor for design = 0.07 Calculated
Vessel head type = Semi-ellipsoidal
= 3.37
= 0.25 m/s
Vessel Heights:
Residence Times and Heights:
Time Calculated Heights Cumulative Heights
LZA(LL) -BOV = - 0.30 m (default) 0.30 m
LZA(LL) -LA(L) = 1.0 min 0.15 m 0.45 m
LA(L) - NLL = 1.5 min 0.60 m 1.05 m
NLL - LA(H) = 1.5 min 0.60 m 1.65 m
LAH - LAHH = 1.0 min 0.15 m 1.80 m
LAHH to TOV = - 1.20 m (default) 3.00 m
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
where the definitions are the same as previously, except for K which is a factor for elliposidal heads based on the
end proportion D/2h - for this calculation K is taken as 1.
Therefore, using the values as before the minimum head thickness = 106.42 mm
The corrosion/cladding allowance is added and then a 10% margin added to give a required minimum thickness of
117.06 mm
The closest standard plate thickness to be used is 118.00 mm
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Head perimeter =
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
1.20 m
m
0.60 m = 1.5 min
0.30 m
6.00 m
Liquid Outlet
Flow = 0.55 kg/s
Density = 1,080 kg/m³
Velocity = 0.27 m/s
Min. Size = 25.59 mm
NB Size = 50.00 mm
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Appendix A
Vessel Sizing
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
A 5.3.18 CST
Operating Conditions
Vessel Tag Number
Fluid Properties
Input Properties Oil Water Vapour Slug
Mass Flows [kg/hr] 10 1,804 85,815
Slug Volume [m3] 20 (Enter known volume or 0 if no slug expected)
Density [kg/m3] 650.0 1,080.4 52.5
Molecular Weight [ - ] - - 16.2
Calculated Properties Oil Water Vapour Slug Total Fluid Total Liquid
Volume Flowrate [bbl/d, MMscfd] 2 252 106.1 125.9 87,629 1,814
Mixed Phase Density [kg/m3] - - - 1076.4 53.5 1,076.4
Volume Flow [m3/hr] 0.0 1.7 1635.8 1637.5 1.7
Nozzle Sizing
Mixed Phase Inlet Vapour Outlet
Max Inlet Momentum [kg/s2] 1400 Max Outlet Momentum [kg/s2] 3750
Velocity [m/s] 5.1 Velocity [m/s] 8.5
Min Inlet ID [mm] 336 Min Outlet ID [mm] 262
Specified ND 400 Specified ND 300
Liq Outlet
Max Outlet Velocity [m/s] 1
Min Outlet ID [mm] 24
Specified ND 50
Note
Slug Volume is 90.9 % of Control Volume between NLL and LAH.
Calculation Sheet
Appendix B
Line Sizing
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
A 9/3/18 CST
Line Number =
Mixture Mass Flow Rate = 175238.2 kg/h
3
Actual Mixture Density = 53.51 kg/m
Pipe Internal Diameter = 330.20 mm
Equivalent Length = 20.0 m
C-Factor (in SI units; see below) = 122
2
Pipe Cross-sectional Area = 0.0856 m
3
Actual Volumetric Flow Rate = 3274.94 m /h
Mixture Velocity = 10.62 m/s
Erosional Velocity = 16.68 m/s
Pressure Drop = 13.71 kPa/100m
= 2.74 kPa
ASSUMPTIONS
1) The Moody friction factor is assumed to be an average of 0.015. At low velocities this requires verification. [Ref.1]
2) The empirical constant for erosional velocity (SI units) has the following recommended values: [Ref.1]
- Solids-free, continuous service 122
- Solids-free, intermittent service 152.5
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; continous service 183 - 244
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; intermittent service up to 305
3) The table in 2) is in accordance with API RP 14E. Subsequent review by independent oil and gas operators and scientists
has demonstrated that this table is highly conservative and even shows a reverse trend with mixture density.
For solids-free liquid impingement erosion a C-factor of 366 may be assumed. [Ref.2]
4) According to Ref.3, errors of up to ± 20% may normally be anticipated on calculated pressure drop.
Verification using approved modelling software should be considered during detailed design.
5) Though based on an offshore code, the above methodology is applicable to onshore piping subject to the stated constraints.
REFERENCES
1) API RP 14E, "Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems", 5th Ed., 1-Oct-91
2) M.M Salama and E.S Venkatesh, "Evaluation of API RP 14E Erosional Velocity Limitations of Offshore gas Wells",
OTC 4485, 15th Annual OTC in Houston, May 1983
A 9/3/18 CST
Line Number =
Mixture Mass Flow Rate = 87619.1 kg/h
3
Actual Mixture Density = 53.51 kg/m
Pipe Internal Diameter = 242.87 mm
Equivalent Length = 20.0 m
C-Factor (in SI units; see below) = 122
2
Pipe Cross-sectional Area = 0.0463 m
3
Actual Volumetric Flow Rate = 1637.47 m /h
Mixture Velocity = 9.82 m/s
Erosional Velocity = 16.68 m/s
Pressure Drop = 15.92 kPa/100m
= 3.18 kPa
ASSUMPTIONS
1) The Moody friction factor is assumed to be an average of 0.015. At low velocities this requires verification. [Ref.1]
2) The empirical constant for erosional velocity (SI units) has the following recommended values: [Ref.1]
- Solids-free, continuous service 122
- Solids-free, intermittent service 152.5
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; continous service 183 - 244
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; intermittent service up to 305
3) The table in 2) is in accordance with API RP 14E. Subsequent review by independent oil and gas operators and scientists
has demonstrated that this table is highly conservative and even shows a reverse trend with mixture density.
For solids-free liquid impingement erosion a C-factor of 366 may be assumed. [Ref.2]
4) According to Ref.3, errors of up to ± 20% may normally be anticipated on calculated pressure drop.
Verification using approved modelling software should be considered during detailed design.
5) Though based on an offshore code, the above methodology is applicable to onshore piping subject to the stated constraints.
REFERENCES
1) API RP 14E, "Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems", 5th Ed., 1-Oct-91
2) M.M Salama and E.S Venkatesh, "Evaluation of API RP 14E Erosional Velocity Limitations of Offshore gas Wells",
OTC 4485, 15th Annual OTC in Houston, May 1983
Std Calc: WS-CA-PR-001 Rev 3 \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\HP Separator sizing\Outlet Line SizingProd Date Printed: 3/16/2018
Calculation Cover Sheet
Calculation Method
In-house WP Flare KO Drum spreadsheet
Assumptions
See content
Software Used
Title Version Validation (Y / N / N/A)
SeleXpress 3.2.1.92 Y
References
1. API Std 521
2. DEP 80.45.10.10
3. Process Datasheet for Flare Knock-out Drum Rev.1 (Doc. no.: 0846-ON-PDS-0811-10)
Conclusions
Dimensions: Design Conditions:
ID = 4200 mm Design Temperature = -45 / 220 o C
T/T = 17000 mm Design Pressure = 3.5 barg
Dimensions:
Mixed phase inlet = 36"
Gas outlet = 44"
Liquid outlet = 2"
Table of Contents
Objective 4
Method 4
Assumptions 4
Fluid Properties and Details 5
Separation Data 6
Calculated Values 6
Vessel Sizing 6
Weight Calculation 7
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Method:
In-house WP Flare KO Drum spreadsheet
Assumptions:
1. Flare KO Drum will be sized based on full flow relief rate of 10.05 MMSCMD and capable of disengaging entrained
droplets of 500 µm or larger.
2. The liquid space on top of LA(HH) will be designed to accommodate the maximum emergency liquid relief rate of
72.5 m3/h from maximum condensate flow for LV-1101 within a period of 40 minutes.
3. Flare header size is 900 mm. The properties of full flow relief is based on the calculated backpressure at the Flare
KO Drum is used in vessel sizing, i.e. 0.7 barg
4. No margin is applied for Flare KO Drum Sizing.
5. Since the relief flow is essentially dry (mass fraction>95%), a max allowable gas load factor, k value of 0.25 m/s to
be used as recommended in DEP 80.45.10.10
6. Level setting criteria for Flare KO Drum sizing is as recommended in DEP 80.45.10.10.
Parameter Criteria
LAHH to bottom of inlet nozzle Minimum 150 mm
LAH to LAHH 60 s pump out capacity or 150 mm whichever is greater
NLL to LAH 150 s pump out capacity or 100 mm whichever is greater
LAL to NLL 150 s pump out capacity or 100 mm whichever is greater
LALL to LAL 60 s pump out capacity or 200 mm whichever is greater
Bottom tan line to LALL 150 mm
L/D 2 ≤ L/D ≤ 6
7. Flare KO Drum will be sized to cater for 2 inlets.
8. Nozzle sizing criteria for HP Flare KO Drum sizing is as recommended in DEP 80.45.10.10
Nozzle Criteria
Inlet ρV2 < 5000 Pa (half open pipe)
Vapour Outlet ρV2 < 6000 Pa
Liquid Outlet Velocity < 1 m/s
9. Minimum required time to empty the drum during emergency is within 2 hours (from LAHH to LAL).
Conclusion:
Vessel Size Level Setting
Vessel ID = 4200 mm LAHH(max) - TOV = 3060 mm
Vessel T/T = 17000 mm LAHH - LAHH(max) = 440 mm
L/D = 4 LAH - LAHH = 150 mm
LAL - LAH = 200 mm
Nozzle Size LALL - LAL = 200 mm
Mixed phase inlet nozzle size = 36" (based on 2 inlets) BOV - LALL = 150 mm
Gas outlet nozzle size = 44"
Liquid outlet nozzle size = 2"
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Gas Outlet:
Gas Outlet Stream = Flare gas outlet@0.7barg
Operating Pressure = 70.0 kPag
Design Pressure = 350.0 kPag Calculated
Operating Temperature = -38.0 °C
Design Temperature = 65.0 °C
Standard Gas Flow = 418524 Sm³/h
Gas Volumetric Rate = 200366 Am³/h
Gas Density (ρg) = 1.46 kg/m³
Gas Mass Rate = 292350 kg/s
Gas viscosity (µg) = 0.009 cP
Gas Rate (Qg) = 56 m³/s
Liquid Outlet:
Liquid Outlet Stream = Condy outlet@0.7barg
Hydrocarbon phase mass rate = 0.0 kg/s
Hydrocarbon phase density = 0.0 kg/m³
Hydrocarbon phase viscosity = 0.0 cP
Hydrocarbon phase surface tension = 0.0000 N/m
Light phase volumetric rate = 0.0 m3/s
Aqueous phase mass rate = 5184.9 kg/s
Aqueous phase density = 1105.0 kg/m³
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Separation Data:
Storage for miscellaneous liquids = 48.3 m3
Release time (liquid holdup) = 40.0 min
Vessel vapour passes = 2
Droplet diameter to be separated = 500 µm
Calculated Values:
Liquid flowrate = 5 m3/h
Vapour flowrate = 56 Am³/s
Particle Diameter = 0.00050 m =D
= 2.57 m/s
Vessel Sizing:
Vessel diameter = 4.20 m
Vessel t/t length = 17.0 m
Vessel L/D = 4.05
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Nozzle Sizing:
Inlet nozzle:
Maximum ρv² = 5000 kg/m.s² Manual entry
Minimum size inlet nozzle (NB) = 781.43 mm
Selected inlet nozzle (NB) = 900.0 mm
Selected schedule = Std
Selected inlet nozzle ID = 895.4 mm
Inlet nozzle velocity = 58.03 m/s
Calculated ρv” = 2901 kg/m.s²
Nozzle size check: Nozzle size acceptable
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
where the definitions are the same as previously, except for K which is a factor for elliposidal heads based on the
end proportion D/2h - for this calculation K is taken as 1.
Therefore, using the values as before the minimum head thickness = 8.083 mm
The corrosion/cladding allowance is added and then a 10% margin added to give a required minimum thickness of
13.083 mm
The closest standard plate thickness to be used is 14.000 mm
Weight Calculation:
The steel volume of the shell is calculated from:
Head perimeter =
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Appendix A
Vessel Sizing
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
SUBJECT Flare KO Drum sizing @ 0.7barg (level setting & nozzle) SHEET of
Basis: Minimum Control Height criteria
REV DATE BY CKD REV DATE BY CKD REV DATE BY CKD
A 22/3/2018 CST
Operating Conditions
Vessel Tag Number
Fluid Properties
Input Properties Oil Water Vapour Slug
Mass Flows [kg/hr] 0 5,185 292,350
3
Slug Volume [m ] 0 (Enter known volume or 0 if no slug expected)
Density [kg/m3] 800.0 1,105.0 1.5
Molecular Weight [ - ] - - 16.52
Calculated Properties Oil Water Vapour Slug Total Fluid Total Liquid
Volume Flowrate [bbl/d, MMscfd] 0 708 355.3 0.0 297,535 5,185
Mixed Phase Density [kg/m3] - - - 1105.0 1.5 1,105.0
Volume Flow [m3/hr] 0.0 4.7 200366.4 200371.1 4.7
Nozzle Sizing
Mixed Phase Inlet Vapour Outlet
Max Inlet Momentum [kg/s2] 5000 Max Outlet Momentum [kg/s2] 6000
Velocity [m/s] 58.0 Velocity [m/s] 64.1
Number of inlets 2 Min Outlet ID [mm] 1051
Min Inlet ID [mm] 781 Specified ND 1100
Specified ND 900
Liq Outlet
Max Outlet Velocity [m/s] 1
Min Outlet ID [mm] 41
Specified ND 50
Note
Slug Volume is 0.0 % of Control Volume between NLL and LAH.
LAHH = 0.7 m
3
Cylindrical liquid volume @ LAHH = 25.80 m
Head liquid volume @ LAHH = 0.72
Horizontal Flare Knock Out Drum Sizing (SI Units)
Standard Calculation WS-PR-CA-012, Rev. 1, "Re-Issued for Use", 2-Sep-02
Validated: Verification of WS-PR-CA-012, Rev. 1, "Re-Issued for Use", 2-Sep-02
A 22/3/2018 CST
Input Data
3
Liquid Mass Rate = 5,185 kg/hr Storage for Misc. Liquids = 48.33 m
3
Liquid Density = 1105.0 kg/m Release Time (Liquid Holdup) = 40 min
Calculated Parameters
Appendix B
Drag Coefficient Estimation
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Appendix C
Hysys Properties
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Appendix D
Vessel Sketch
Inlet Nozzle (N1A) Gas outlet nozzle (N2) Inlet nozzle (N1B)
900 mm 1100 mm 900 mm
ID = 4200 mm
N12
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Page 57 of 74
1:53 PM 3/28/2018
Rev 6.5
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blow
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KG DWN 98/2 Part III Proj No:
Client: ONGC Phase/CTR:
Cover Sheet 28-Mar-18 Total Pages: 10 Plus Cover, TOC & Checklist
(a) Calculation Objective
(b) Assumptions
(c) References
(d) Conclusions
Perunding Ranhill Worley Calculation Pad 1 of 3 01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note - Calc Cover
5:08 PM 3/27/2018
Note:
Change
Row height
Youcells
can
is with
50
copy
for
a
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KG DWN 98/2 Part III Proj No:
Client: ONGC Phase/CTR:
Table of Contents Page: 2 Plus Cover, TOC & Checklist
(e) Table of Contents Page Row
Rev
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 16/3/2018 Issued for Review CST MM 16/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 2 of 11 01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note - Calc Cover
5:08 PM 3/27/2018
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KG DWN 98/2 Part III Proj No:
Client: ONGC Phase/CTR:
Checklist Page: 3 Plus Cover, TOC & Checklist
(f) Check List
Rev
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available in addition to software version.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification checked.
Checking records:
Checked and annotated copy of calculation filed (use "Document Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 16/3/2018 Issued for Review CST MM 16/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 3 of 11 01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note - Calc Cover
5:08 PM 3/27/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X 27-Mar-18 Page: 4 of 10
Rev
1.0 OBJECTIVES
1. To calculate the blowdown load from new HP Separators during emergency shutdown
2. To check minimum temperature achievable during blowdown scenario
3. To size the blowdown RO for the new HP Separator BDVs
4. To determine new staggered blowdown load during emergency shutdown
1. The following summarizes input parameter for Hysys Depressuring Scenarios for new HP Separator blowdown segment.
Minimum Temperature
PARAMETER Fire Case Adiabatic Case
Case
Design Pressure of Design Pressure of Design Pressure of
Initial Pressure
vessel vessel vessel
Minimum ambient
Initial Normal operating Normal operating temperature or operating
Temperature temperature temperature temperature whichever
lowever
2. 20 m of piping length between SDV and inlet nozzle of HP Separator and 10 m of piping length between outlet nozzle to SDVs are assumed.
3. Design pressure of HP Separator is 80 barg.
4. Production fluid arrival temperature of HP Separator is at 11 ⁰C. However, operating temperature for Fire and Adiabatic blowdown scenarios
is assumed at 20 ⁰C due to heat gain from the environment.
5. Initial Temperature of HP Separator for Low Temperature case is taken at 11 ⁰C.
6. 20% margin on piping volume to cater for uncertainties.
7. New fuel gas package is identical to existing package.
8. New Gas Dehydration Unit is identical to existing package.
3.0 METHODOLOGY
HYSYS Dynamic Depressuring Utiility from ASPEN HYSYS V8.8 is used to determine the peak blowdown load and the minimum temperature
achievable during blowdown scenario.
In-house line sizing spreadsheet is used to size the inlet line while Aspen Flare System Analyzer v8.8 is used to model the flare network.
Rev: A Page: 4 of 10
Perunding Ranhill Worley Calculation Pad 4 of 11 01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note - 4
5:08 PM 3/27/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X 27-Mar-18 Page: 5 of 10
Rev
Rev: A Page: 5 of 10
Perunding Ranhill Worley Calculation Pad 5 of 11 01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note - 5
5:08 PM 3/27/2018
Calculation Sheet 1
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KeywordPerundingRanhillWorleyLandscape
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X Page: 6 of 10
4.0 RESULTS AND DISCUSSION
4.1 Blowdown Load Results
Rev: A Page: 6 of 10
5:08 PM 3/27/2018
Calculation Sheet 1
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Calculation Title: HP Separator BDV Sizing Calculation Calc Number: PR-CAL-0002
Project Title: KeywordPerundingRanhillWorleyLandscape
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X Page: 7 of 10
4.0 RESULTS AND DISCUSSION
4.2 Comparison of Existing and New Blowdown Loads
200,000
Receiving area new peak Staggered Blowdown Load (NEW)
flow @ 198,366 kg/h Staggered Blowdown Load (Existing)
Receiving Area (NEW)
100,000
50,000
0
0 200 400 600 800 1000 1200 1400 1600 1800
Time (seconds)
Rev: A Page: 7 of 10
5:08 PM 3/27/2018 8 of 11
Attachment A 1
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 8 of 10
SDV @ feed inlet HP Separator 16 80 406.4 12.70 381.0 20000 1 23.94 2.28 0.0121 2.74 0.03 2.70 28.73 4.27
HP Separator SDV @ gas outlet 12 80 304.8 12.70 279.4 10000 1 8.78 0.61 0.0000 0.74 0.00 0.74 10.53 0.00
HP Separator SDV @ liquid outlet 2 80 50.8 5.54 39.7 10000 1 1.25 0.01 1.0000 0.01 0.01 0.00 1.50 1.50
HP Separator (LAH) 111.0 3000 6000 1 76.06 49.48 - 49.48 27.96 21.52 76.06 40.46
SDV @ feed inlet HP Separator 16 80 406.4 12.70 381.0 20000 1 23.94 2.28 0.0121 2.74 0.03 2.70 28.73 4.27
HP Separator SDV @ gas outlet 12 80 304.8 12.70 279.4 10000 1 8.78 0.61 0.0000 0.74 0.00 0.74 10.53 0.00
HP Separator SDV @ liquid outlet 2 80 50.8 5.54 39.7 10000 1 1.25 0.01 1.0000 0.01 0.01 0.00 1.50 1.50
HP Separator (LAL) 111.0 3000 6000 1 76.06 49.48 - 49.48 4.42 45.06 76.06 19.26
SDV @ feed inlet HP Separator 16 80 406.4 12.70 381.0 20000 1 23.94 2.28 0.0123 2.74 0.03 2.70 28.73 4.29
HP Separator SDV @ gas outlet 12 80 304.8 12.70 279.4 10000 1 8.78 0.61 0.0000 0.74 0.00 0.74 10.53 0.00
HP Separator SDV @ liquid outlet 2 80 50.8 5.54 39.7 10000 1 1.25 0.01 1.0000 0.01 0.01 0.00 1.50 1.50
HP Separator (LAH) 111.0 3000 6000 1 76.06 49.48 - 49.48 27.96 21.52 76.06 40.46
SDV @ feed inlet HP Separator 16 80 406.4 12.70 381.0 20000 1 23.94 2.28 0.0123 2.74 0.03 2.70 28.73 4.29
HP Separator SDV @ gas outlet 12 80 304.8 12.70 279.4 10000 1 8.78 0.61 0.0000 0.74 0.00 0.74 10.53 0.00
HP Separator SDV @ liquid outlet 2 80 50.8 5.54 39.7 10000 1 1.25 0.01 1.0000 0.01 0.01 0.00 1.50 1.50
HP Separator (LAL) 111.0 3000 6000 1 76.06 49.48 - 49.48 4.42 45.06 76.06 19.26
Attachment B 2
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 9 of 10
Attachment C 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Blowdown\[01410 IAPSB-PR-CAL-0002 - Blowdown Calculation Note.xls]5
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 10 of 10
Line/Unit No:
Units SI SI SI SI SI
Phase Gas Gas Gas Gas Gas
Diameter, Nominal 150.00 mm mm mm mm mm
Type of Pipe Commercial Steel Commercial Steel Commercial Steel Commercial Steel Commercial Steel
Pipe Schedule Sch 80 Std Sch 40 Sch 40 Sch 80
Pipe Class Optional Override Optional Override Optional Override Optional Override Optional Override
User can override WT/ID Incorrect Schedule No. Incorrect Schedule No. Incorrect Schedule No. Incorrect Schedule No.
O.D.,mm User Input User Input User Input User Input User Input
WT., mm User Input User Input User Input User Input User Input
I.D. / W.T.,mm 146.33 10.97 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Flow Type Mass Mass Mass Mass Mass
Actual Flowrate 31607 kg/h kg/h kg/h kg/h kg/h
Inlet Temperature 20 °C °C °C °C °C
Inlet Pressure 8101.325 kPaa kPaa kPaa kPaa kPaa
Pressure Linked to previous line Link from Line 1 Outlet Pressure Link from Line 2 Outlet Pressure Link from Line 3 Outlet Pressure Link from Line 4 Outlet Pressure
Inlet Pressure 8101.325 kPaa 0 kPaa 0 kPaa 0 kPaa 0 kPaa
Molecular Weight 16.23
Compressibility Not required
Gas k Value at Outlet (CP / CV) 1.629
User Defined Density 63.99 kg/m3 kg/m3 kg/m3 kg/m3 kg/m3
(User can override density) (User can override density) (User can override density) (User can override density)
Density 63.990 kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3
Viscosity 0.0134 cP cP cP cP cP
Design Margin % % % % %
Eq Lengths Eq Lengths Eq Lengths Eq Lengths Eq Lengths
Elbows / Bends / Tees No. metres No. metres No. metres No. metres No. metres
Elbow 90° (LR) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Elbow 45° (LR) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Bend 90°, R = 5D 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Bend 180°, R = 5D 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Tee Through 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Tee 90° Branch 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Valves
Ball (red. bore 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Ball (red. bore 50 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Gate (std. bore) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Gate (red. bore 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (straight pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (Y pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (angle pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Check (swing type) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Check (ball or piston 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Plug (regular) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Butterfly ( 150 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Strainer (Y and Bucket Type) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Enlargers & Reducers
Nominal Size (upstream) mm mm mm mm mm
Nominal Size (downstream) mm mm mm mm mm
Reducer 0.00 0.00 0.00 0.00 0.00
Enlarger 0.00 0.00 0.00 0.00 0.00
Entrance & Exits
Entrance - Inward Projecting 1 7.51 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Entrance - Flush 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Exits - All cases 1 9.63 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
User Defined K Value & DP
K Value for Fitting 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Pressure Drop: Item 1 kPa kPa kPa kPa kPa
Pressure Drop: Item 2 kPa kPa kPa kPa kPa
Fittings Eq. Length, m 17.14 #VALUE! #VALUE! #VALUE! #VALUE!
Pipe Straight Length 20 m m m m m
Total Eq. Length, m 37.14 #VALUE! #VALUE! #VALUE! #VALUE!
Elevation Change m m m m m
CALCULATED VALUES: SI Results SI Results SI Results SI Results SI Results
Mass Flow 31607.00 kg/h 0.00 kg/h 0.00 kg/h 0.00 kg/h 0.00 kg/h
Actual Vol. Flow Rate 493.94 m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h
Static Head Loss 0.00 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Reynolds No. 5701045 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Moody Friction Factor 0.0152 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Pressure Drop 22.12 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m
Design Pressure Drop 22.12 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m
Inlet Velocity 8.16 m/s 0.00 m/s 0.00 m/s 0.00 m/s 0.00 m/s
Design Total Drop 8.21 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Cumulative Design Total Drop 8.21 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Inlet Press 8101 kPaa 0 kPaa 0 kPaa 0 kPaa 0 kPaa
Outlet Press 8093 kPaa #DIV/0! kPaa #DIV/0! kPaa #DIV/0! kPaa #DIV/0! kPaa
Outlet Density 63.93 kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3
Outlet Vol Flow 494.44 m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h
Outlet Velocity 8.17 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Pressure Drop/Inlet P 0.10 % #DIV/0! % #DIV/0! % #DIV/0! % #DIV/0! %
VELOCITY CHECK
Noise Limit 24.20 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Sonic Velocity at Outlet (Vs) 494.61 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Erosional Velocity Limit : C 122 100 122 122 122
Ve 15.25 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
WARNINGS: #DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
Std Calc: WS-CA-PR-001 Rev 3 \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Blowdown\BDV Inlet Line SizingProd Date Printed: 3/16/2018
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 58 of 74
2:00 PM 3/28/2018
Rev 6.5
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\PSV sizing\[01410 IAPSB-PR-CAL-0003 -P
Calculation Title: PSV Sizing Calculation Calc Number: PR-CAL-0003
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Cover Sheet 28-Mar-18 Total Pages: 8 Plus Cover, TOC & Checklist
(a) Calculation Objective
To document the PSV and inlet line sizing calculation for 2 x 50% HP Separators full flow blocked discharge scenario
(b) Assumptions
(c) References
1. API STANDARD 521 - Pressure-relieving and Depressuring Systems (6th edition, January 2014)
2. API STANDARD 526
3. Heat and Material Balance
4. OFFSHORE DESIGN GUIDE WS-DG-PR-007 (Relief & Blowdown Calculations)
(d) Conclusions
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0003 -PSV Calculation Note - Calc Cover
6:03 PM 3/16/2018
Note:
Change
Row height
Youcells
can
is with
50
copy
for
a
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 16/3/2018 Issued for Review CST MM 16/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0003 -PSV Calculation Note - Calc Cover
6:03 PM 3/16/2018
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available in addition to software version.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification checked.
Checking records:
Checked and annotated copy of calculation filed (use "Document Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 16/3/2018 Issued for Review CST MM 16/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0003 -PSV Calculation Note - Calc Cover
6:03 PM 3/16/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
1.0 OBJECTIVE
To document the PSV and inlet line sizing calculation for 2 x 50% HP Separators full flow blocked discharge scenario
1. The following summarizes input parameter for full flow blocked discharge Scenario of new HP Separator during overpressure.
Initial Pressure = Design Pressure of vessel
Initial Temperature = Normal operating temperature
2. 20 m of piping length between outlet nozzle of HP Separator to PSV is assumed.
3. Design pressure of HP Separator is 80 barg.
4. Production fluid arrival temperature of HP Separator is at 11 ⁰C.
3.0 METHODOLOGY
1. For estimation of relief rate, the methodology given in API RP-520; API RP-521 shall generally apply, however the specific procedures, practices and
requirements as detailed in the following is considered.
2. In-house RWP line sizing spreadsheet is used to size the inlet line. While Aspen Flare System Analyzer v8.8 is used to model the flare network.
General
a. The possibility of two or more related emergency conditions ('multiple contigencies') shall not be evaluated.
b. No credit shall be taken for the presence of emergency instrumentation and the response of plant operators in determining relief requirement, except
in those instances allows for in the codes.
c. Flow rate through equipment and other conditions during the particular contigency shall be assumed to be at the maximum operating flow, except
where the contingency directly alters the flow. A standard exception is fire exposure where it is normally assumed that the equipment is blocked in,
ie. incoming and outgoing process flows are stopped.
d. No credit shall be taken for increased out-flow via a pressure controlled side stream due to action by the controller.
𝑊 𝑇𝑍 Where:
𝐴=
𝐶𝐾 𝑃 𝐾 𝐾 𝑀 W= Relief flow T = Relief temperature
k= Ideal gas specific heats Z = Compressibility factor
Kd, Kb, Kc = Correction factors M = Molecular weight
2 P1 = Relief pressure
𝐶 = 520 𝑘
𝑘+1
Rev: A Page: 4 of 8
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0003 -PSV Calculation Note - Methodology
6:03 PM 3/16/2018
Calculation Sheet 9
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
4.0 RESULTS
PSV Sizing
Required Load 87619 kg/h (Load for 2 x 50% configuration)
Required Relief Valve Area 1294 mm2
Selected Relief Valve Area 1841 mm2
Rated Load 124618 kg/h
PSV Size 4L6
Rev: A Page: 5 of 8
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0003 -PSV Calculation Note - Methodology
6:03 PM 3/16/2018 6 of 8
Attachment A 1
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 6 of 8
Attachment B 2
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 7 of 8
A 9.3.18 CST
PSV SET PRESSURE 8,000 kPag LIQUID CAPACITY CERTIFICATION REQD ? (Y/N) N
ALLOWABLE OVERPRESSURE 10 %
RELIEF TEMPERATURE 11 C CHECK OVERPRESSURE CORRECTION FACTOR
LIQUID RELIEF RATE 1,804 kg/hr
3
LIQUID DENSITY (at Temperature) 1081 kg/m
BACKPRESSURE FACTOR KW 1.00
manual input To refine the calculated relief area, calculate Kv from
OVERPRESSURE FACTOR Kp 0.60 API520. This is particularly important if the calculated
VISCOSITY FACTOR KV 1.00 relief area is close to the selcted standard orifice size
DISCHARGE COEFFICIENT Kd 0.62
PSV BACKPRESSURE 800 kPag
RELIEF VALVE AREA 9.5 mm2
Attachment C 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\PSV sizing\[01410 IAPSB-PR-CAL-0003 -PSV Calculation Note.xls]Attachments
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 8 of 8
Line Number =
Mixture Mass Flow Rate = 124617.9 kg/h
Actual Mixture Density = 76.85 kg/m3
Pipe Internal Diameter = 242.87 mm
Equivalent Length = 20.0 m
C-Factor (in SI units; see below) = 122
Pipe Cross-sectional Area = 0.0463 m2
Actual Volumetric Flow Rate = 1621.57 m3/h
Mixture Velocity = 9.72 m/s
Erosional Velocity = 13.92 m/s
Pressure Drop = 22.43 kPa/100m
= 4.49 kPa
ASSUMPTIONS
1) The Moody friction factor is assumed to be an average of 0.015. At low velocities this requires verification. [Ref.1]
2) The empirical constant for erosional velocity (SI units) has the following recommended values: [Ref.1]
- Solids-free, continuous service 122
- Solids-free, intermittent service 152.5
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; continous service 183 - 244
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; intermittent service up to 305
3) The table in 2) is in accordance with API RP 14E. Subsequent review by independent oil and gas operators and scientists
has demonstrated that this table is highly conservative and even shows a reverse trend with mixture density.
For solids-free liquid impingement erosion a C-factor of 366 may be assumed. [Ref.2]
4) According to Ref.3, errors of up to ± 20% may normally be anticipated on calculated pressure drop.
Verification using approved modelling software should be considered during detailed design.
5) Though based on an offshore code, the above methodology is applicable to onshore piping subject to the stated constraints.
REFERENCES
1) API RP 14E, "Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems", 5th Ed., 1-Oct-91
2) M.M Salama and E.S Venkatesh, "Evaluation of API RP 14E Erosional Velocity Limitations of Offshore gas Wells",
OTC 4485, 15th Annual OTC in Houston, May 1983
www.advisian.com
Page 59 of 74
1:41 PM 3/28/2018
Rev 6.5
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flar
Calculation Title: Flare Header Sizing Calculation Calc Number: PR-CAL-0005
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Cover Sheet 28-Mar-18 Total Pages: 9 Plus Cover, TOC & Checklist
(a) Calculation Objective
1. To document the PSV tailpipe, BDV tailpipe and Flare header sizing calculation results for the following scenarios:
Full flow relief load of 10.05 MMSCMD resulted from combined relief from the receival area (2 x 50% HP Separators and Slug Catcher).
Staggered emergency depressurisation from receival area and process area
2. To perform the flare header size adequacy check for new 36" extension on existing flare header to cater for new flare KO drum.
(b) Assumptions
(c) References
1. API STANDARD 521 - Pressure-relieving and Depressuring Systems (6th edition, January 2014)
2. API STANDARD 526
3. Equipment Layout
(d) Conclusions
1. Flare Header size of 36" is adequate to cater for full flow relief of 10.05 MMSMD.
2. 1x50% HP Separator PSV tailpipe size is 12"
1x50% HP Separator BDV tailpipe size is 10"
2x50% HP Separator relief subheader size is 20"
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Calc Cover
1:41 PM 3/28/2018
Note:
Change
Row height
Youcells
can
is with
50
copy
for
a
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
Page Row
Heading: No: Worksheet Name: No:
Cover, TOC & Checklist 1 1
1.0 OBJECTIVE 2 4
2.0 INTRODUCTION 2 4
3.0 METHODOLOGY 2 4
4.0 RESULTS 5 5
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 28/3/2018 Issued for Review CST MM 28/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Calc Cover
1:41 PM 3/28/2018
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available in addition to software version.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification checked.
Checking records:
Checked and annotated copy of calculation filed (use "Document Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 28/3/2018 Issued for Review CST MM 28/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Calc Cover
1:41 PM 3/28/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
1.0 OBJECTIVE
1. To document the PSV tailpipe, BDV tailpipe and Flare header sizing calculation results for the following scenarios:
a. Full flow relief load of 10.05 MMSCMD resulted from combined relief from the receival area (2 x 50% HP Separators and Slug Catcher).
b. Staggered emergency depressurisation from receival area and process area
2. To perform the flare header size adequacy check for new 36" extension on existing flare header to cater for new flare KO drum.
1. Flare header size of the Flare KO Drum gas outlet is 900 mm. Flare stack elevation of 53.5m is assumed.
2. Total gas outlet flowrate is 10.04 MMSCMD (292,350 kg/h).
3. Pressure drop of 0.1 bar across flare tip is assumed.
4. 200 meter of 36" extension is added onto existing flare header to cater for new Flare KO Drum.
5. Flare gas outlet composition is based on combined full flow relief of 5.75 MMSCMD from U-field 2x50% HP Separator and 4.3 MMSCMD from
Vashista Slug Catcher.
Component Mole fraction
Nitrogen 0.00862
CO2 0.00218
Methane 0.97629
Ethane 0.00620
Propane 0.00324
i-Butane 0.00067
n-Butane 0.00103
i-Pentane 0.00030
n-Pentane 0.00024
n-Hexane 0.00018
n-Heptane 0.00002
n-Octane 0.00000
n-Nonane 0.00000
n-Decane 0.00000
EGlycol 0.00000
TEGlycol 0.00000
H2O 0.00011
Oxygen 0.00092
Operating pressure of Flare KO Drum is at 0.7 barg.
6. The following criteria were followed to determine the required tailpipe size.
- Maximum Mach no. in the tailpipe and subheader shall be kept below 0.8
- Maximum Mach no. in the main flare header shall be kept below 0.5
7. Maximum back pressure shall not exceed 150# piping design pressure which is the lowest pipe rating in the flare network.
3.0 METHODOLOGY
1. Flare network hydraulic calculations are performed using Aspen Flare System Analyser (Flarenet) Version 8.8.
2. The size of flare header is established by the governing flaring load and velocity calculations based on header Mach no. and the developed
backpressure.
3. Vent model was built based on equipment layout.
4. The following pressure drop approach has been considered in the Flarenet model:
- Single phase - Isothermal Gas
- Two phase - Beggs & Brill
5. Peng Robinson EOS was used for VLE calculations and Enthalpy calculations.
6. Flare headers shall be sized based on process load capacity. Mach number for vapour lines is calculated based on the API STD 521 equation 61:
Rev: A Page: 4 of 9
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Methodology
1:41 PM 3/28/2018
Calculation Sheet 9
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
4.0 RESULTS
Below is the summary result from Flare Analyzer based on 36" flare header size.
Tailpipe size is selected to ensure that Mach number is kept below 0.8.
2. Taipipe sizing
HP Separator PSV HP Separator BDV HP Separator relief
Segment
tailpipe tailpipe subheader
Selected size (inch) 12 10 20
Backpressure (barg) 1.92 0.68 1.20
Mach no. 0.62 0.35 0.54
2
rhoV 118,554 25,573 80,474
Rev: A Page: 5 of 9
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Methodology
1:41 PM 3/28/2018 6 of 9
Attachment A 1
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 6 of 9
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 03: 10 MMSCMD Relief
Label : Length/Nom. Diameter /(m : - )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:38:29 PM
1:41 PM 3/28/2018 7 of 9
Attachment B 2
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 7 of 9
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 03: 10 MMSCMD Relief
Label : Pres./Mach Number /(bar_g : - )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:39:06 PM
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 03: 10 MMSCMD Relief
Label : Rho V2 /(kg/m/s2 )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:38:52 PM
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 03: 10 MMSCMD Relief
Label : Mass Flow/Rated Flow /(kg/hr : kg/hr )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:48:27 PM
1:41 PM 3/28/2018 8 of 9
Attachment C 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 8 of 9
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 01: Receival BD
Label : Pres./Mach Number /(bar_g : - )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:40:43 PM
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 01: Receival BD
Label : Rho V2 /(kg/m/s2 )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:40:16 PM
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 01: Receival BD
Label : Mass Flow/Rated Flow /(kg/hr : kg/hr )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:49:05 PM
1:41 PM 3/28/2018 9 of 9
Attachment D 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\[01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note.xls]Calc Cover
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 9 of 9
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0005 -Flare Header Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 02: Process BD
Label : Pres./Mach Number /(bar_g : - )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:39:42 PM
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 02: Process BD
Label : Rho V2 /(kg/m/s2 )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:39:54 PM
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 10 MMSCMD with new 36" flare header
Scenario : Case 02: Process BD
Label : Mass Flow/Rated Flow /(kg/hr : kg/hr )
PFD
\\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\U Field tie-in\Flarenet\FlareHeader_10MMSCMD_36in (
Printed At 3/22/2018 2:48:45 PM
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 60 of 74
Flare Study For ONGC KG-DWN-
98/2 MEG Facility
29 March 2018
402020-01410A-SR-REP-MA01-001
www.advisian.com
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Table of Contents
1 Introduction ........................................................................................................................... 5
1.3 Abbreviations........................................................................................................... 5
2 Methodology ......................................................................................................................... 6
2.1 Study Methodology .............................................................................................. 6
Advisian iii
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
5 Conclusion ............................................................................................................................ 35
6 References ............................................................................................................................ 36
6.1 International Codes and Standards ............................................................... 36
Appendix List
Appendix A: Hazardous Area Classification Layout ........................................................................................... i
Advisian iv
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
1 Introduction
This document presents the findings of the Flare study for the new OMF / Vashishta HP Flare
installation at Onshore MEG plant for ONGC’s KG-DWN-98/2 development.
1.1 Objectives
The objective of this study is to determine the minimum height required for the new HP flare stack
at ONGC KG-DWN-98/2 MEG Facility such that thermal radiation levels, noise limits and flammable
gas cloud concentrations at selected sensitive receptors when the flare is in operation do not
exceed the specified acceptance criteria to ensure safety of personnel.
1.2 Scope
The report covers the Flare study for the new HP flare system installation at ONGC KG-DWN-98/2
MEG Facility. The assessment includes:
1.3 Abbreviations
Advisian Page 5 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
2 Methodology
2.1 Study Methodology
The overall methodology of this study is summarized as follows:
1. Data collection - relevant data for flare study (i.e process inputs, environmental condition
etc) are taken from project specific documents /inter-discipline inputs;
3. Acceptance criteria establishment – acceptance criteria for thermal radiation level and
flammable gas dispersion concentration are established for the study;
6. Impact assessment - the impact of thermal radiation and flammable gas dispersion from
the new HP flare stack on the identified receptor points is assessed with regards to
acceptance criteria; and
Simulation of flammable gas dispersion is conducted using PHAST 7.21. PHAST is a process hazard
analysis software tool which is used for chemical release consequence analysis. The wind direction
simulated in PHAST 7.21 is from the plant South.
Advisian Page 6 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
3 Basis of Study
This section outlines the basis and assumptions made, adopted acceptance criteria and identified
receptor points for this study.
1. Weather condition of 8.3/D and 27.5/D (8.3 m/s and 27.5 m/s wind speed with Pasquill
Stability Class D) are used in sizing of the new HP flare stack height [3, 6];
5. F-factor (fraction of heat radiated) for the new HP flare tip is based on pipe type;
6. The simulated flammable gas dispersion in PHAST has considered the maximum downwind
effects distance to the concentration of interest;
7. The relative humidity and ambient temperature is taken to be 72% and 28˚C respectively
[1].
The selected receptor points at ONGC KG-DWN-98/2 MEG Facility and their coordinates are given
in Table 3-1. The overall ONGC KG-DWN-98/2 MEG Facility plot plan is attached in Appendix A.
Advisian Page 7 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Coordinate
Receptor Point
Receptor Point Description
ID Northing Easting Elevation
Advisian Page 8 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
For the purpose of this study, the flammable gas dispersion simulation is performed for 50% LFL
and 100% LFL gas clouds. The 50% LFL gas cloud shall not be permitted to encroach on the
identified receptor points
Case 1: To study the thermal radiation and noise levels at each receptor points identified
based on the stack height of the existing HP flare and tip diameter of 914.4 mm (36’’);
Sensitivity Case 1: To study the thermal radiation and noise levels at each receptor points
identified based on the stack height of the existing HP flare and tip diameter of 812.8 mm
(32’’);
Case 2: To establish the stack height for the new HP flare stack at tip diameter of 914.4
mm (36’’) whilst ensuring the thermal radiation and noise levels at the receptor points not
exceeding the acceptance criteria; and
Sensitivity Case 2: To establish stack height for the new HP flare stack at tip diameter of
812.8 mm (32’’) whilst ensuring the thermal radiation and noise levels at the receptor
points not exceeding the acceptance criteria.
Process Data
Advisian Page 9 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
HP Flare Design
Meteorological Conditions
Ambient air temperature
28˚C [1]
Relative humidity
72% [1]
Included
Solar radiation
2
1.04 kW/m [6]
Simulated wind speed for
thermal radiation and 8.3/D
flammable gas dispersion
(m/s) / Pasquill Stability
27.5/D
Class
Advisian Page 10 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
4.1 Case 1
For Case 1, the new flare will be operating at flaring load of 292350.2 kg/hr (10.05 MMscmd).
Assessment of the thermal radiation levels at identified receptor points was carried out by using
49.5 m as the height of the new HP flare stack (with additional tip length of 3.0 m).
Table 4-1 summarises the thermal radiation levels at each receptor point. The graphical outputs of
thermal radiation contour at 8.3 m/s and 27.5 m/s wind speeds for Case 1 are shown in Figure 4-1,
4-2, 4-3 and 4-4.
Based on Table 4-1, at wind speed of 27.5 m/s, the thermal radiation levels at receptor points RP_1
(New HP Flare Stack Base) and RP_2 (Sterile Area Boundary Plant North) exceed the acceptance
2 2
criteria potentially reaching 7.05 kW/m and 6.80 kW/m respectively. Therefore, configuration of
the new HP flare stack has been further analysed to satisfy the acceptance criteria at RP_1 and RP_2
(refer Section 4.3).
Base Case
2
Receptor Receptor Point Acceptance Thermal Radiation (kW/m )
2 Acceptance
Point ID Description Criteria (kW/m )
8.3/D 27.5/D
Marginally
Sterile Area
above
RP_2 Boundary Plant 6.31 4.91 6.80
acceptance
North
criteria
Advisian Page 11 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Base Case
2
Receptor Receptor Point Acceptance Thermal Radiation (kW/m ) Acceptance
2
Point ID Description Criteria (kW/m )
Sterile Area
RP_3 Boundary Plant 6.31 3.93 4.30 Acceptable
East
Sterile Area
RP_4 Boundary Plant 6.31 4.00 4.33 Acceptable
West
Sterile Area
RP_5 Boundary Plant 6.31 3.25 3.13 Acceptable
Southwest
Figure 4-1: Plan View of Thermal Radiation Contour at 8.3 m/s Wind Speed (Case 1)
Advisian Page 12 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-2: Elevation View of Thermal Radiation Contour at 8.3 m/s Wind Speed (Case 1)
Advisian Page 13 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-3: Plan View of Thermal Radiation Contour at 27.5 m/s Wind Speed (Case 1)
Advisian Page 14 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-4: Elevation View of Thermal Radiation Contour at 27.5 m/s Wind Speed (Case 1)
Wind speeds of 8.3 m/s and 27.5 m/s were considered for the assessment of flammable gas
dispersion. A downwind direction from plant South blowing towards the receptors points was
modelled in event of flame-out of the new HP flare stack. The extent of the 50% LFL and 100% LFL
gas clouds at different wind speeds are illustrated in Figure 4-5 and 4-6.
Figure 4-5 and 4-6 show that the 50% LFL and 100% LFL flammable gas clouds at stack height of
49.5 m do not descend downwards encroaching the receptor points at ground level.
Advisian Page 15 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
4.1.3 Noise
The noise limit for emergency condition is 115dB(A) at all receptor points. The noise levels at
receptor points for Case 1 are tabulated in Table 4-2 and do not exceed the noise limit for
emergency condition.
Advisian Page 16 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Case 1
8.3/D 27.5/D
RP_1 New HP Flare Stack Base 109 109
Sterile Area Boundary Plant
RP_2 103 103
North
Sterile Area Boundary Plant
RP_3 103 103
East
Sterile Area Boundary Plant
RP_4 103 103
West
Sensitivity Case 1 is conducted to study the thermal radiation, flammable gas dispersion and noise
levels for the new HP flare stack if a tip diameter of 812.8 mm (32’’) is used. The flaring load and
height of the stack is maintained at 292350.2 kg/hr (10.05 MMscmd) and 49.5 m height
respectively.
Table 4-3 shows the thermal radiation levels at each receptor point. The graphical outputs of
thermal radiation contour at 8.3 m/s and 27.5 m/s wind speeds for Sensitivity Case 1 are shown in
Figure 4-7, 4-8, 4-9 and 4-10.
The thermal radiation results show that at wind speed of 27.5 m/s, only thermal radiation level at
receptor point RP_1 (New HP Flare Stack Base) slightly exceeds the acceptance criteria, reaching
2
6.38 kW/m .
Advisian Page 17 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Sensitivity Case 1
2
Receptor Receptor Point Acceptance Thermal Radiation (kW/m )
2 Acceptance
Point ID Description Criteria (kW/m )
8.3/D 27.5/D
Marginally
New HP Flare above
RP_1 6.31 5.29 6.38
Stack Base acceptance
criteria
Sterile Area
RP_2 Boundary Plant 6.31 4.47 6.08 Acceptable
North
Sterile Area
RP_3 Boundary Plant 6.31 3.65 3.93 Acceptable
East
Sterile Area
RP_4 Boundary Plant 6.31 3.71 4.00 Acceptable
West
Sterile Area
RP_5 Boundary Plant 6.31 3.05 2.95 Acceptable
Southwest
Advisian Page 18 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-7: Plan View of Thermal Radiation Contour at 8.3 m/s Wind Speed (Sensitivity Case
1)
Advisian Page 19 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-8: Elevation View of Thermal Radiation Contour at 8.3 m/s Wind Speed (Sensitivity
Case 1)
Advisian Page 20 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-9: Plan View of Thermal Radiation Contour at 27.5 m/s Wind Speed (Sensitivity
Case 1)
Advisian Page 21 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-10: Elevation View of Thermal Radiation Contour at 27.5 m/s Wind Speed
(Sensitivity Case 1)
The flammable gas dispersion is conducted for the new HP flare stack flaring at 49.5 m height to
demonstrate the downwind distance and gas cloud pattern. Based on Figure 4-11 and 4-12, the
50% LFL and 100% LFL flammable gas clouds at stack height of 49.5 m do not descend downwards
encroaching the receptor points at ground level.
Advisian Page 22 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-11: Flammable Gas Dispersion of Sensitivity Case 1 at 8.3/D Weather Condition
Figure 4-12: Flammable Gas Dispersion of Sensitivity Case 1 at 27.5/D Weather Condition
4.2.3 Noise
The noise limit for emergency condition is 115dB(A) at all receptor points. The noise levels at
receptor points for Sensitivity Case 1 are tabulated in Table 4-4 and do not exceed the noise limit
for emergency condition.
Advisian Page 23 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Sensitivity Case 1
8.3/D 27.5/D
RP_1 New HP Flare Stack Base 109 109
Sterile Area Boundary Plant
RP_2 103 103
North
Sterile Area Boundary Plant
RP_3 103 103
East
Sterile Area Boundary Plant
RP_4 103 103
West
4.3 Case 2
As discussed in Section 4.1, the thermal radiation levels at RP_1 (New HP Flare Stack Base) and
RP_2 (Sterile Area Boundary Plant North) during worst wind condition, 27.5 m/s do not meet the
2
acceptance criteria of 6.31 kW/m . This is mainly due to high flaring load.
The minimum height of the new HP flare stack to meet the thermal radiation acceptance criterion
at all receptor points is 55.6 m. The radiation levels at various receptor points are shown in Table 4-
5. The graphical outputs of thermal radiation contour at 27.5 m/s wind speed for Case 2 is shown
in Figure 4-13 and 4-14.
Case 2
Thermal Radiation
Receptor Receptor Point Acceptance 2
(kW/m )
2 Acceptance
Point ID Description Criteria (kW/m )
27.5/D
New HP Flare
RP_1 6.31 6.31 Acceptable
Stack Base
Advisian Page 24 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Case 2
Sterile Area
RP_2 Boundary Plant 6.31 6.25 Acceptable
North
Sterile Area
RP_5 Boundary Plant 6.31 3.03 Acceptable
Southwest
Advisian Page 25 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-13: Plan View of Thermal Radiation Contour at 27.5 m/s Wind Speed (Case 2)
Advisian Page 26 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-14: Elevation View of Thermal Radiation Contour at 27.5 m/s Wind Speed (Case 2)
The extent of the 50% LFL and 100% LFL flammable gas clouds at 55.6 m stack height are
presented in Figure 4-15. Figure 4-15 shows that the flammable gas clouds do not descend
downwards encroaching the receptor points at ground level.
Advisian Page 27 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
4.3.3 Noise
The noise limit for emergency condition is 115dB(A) at all receptor points. The noise levels at
receptor points for Case 2 are shown in Table 4-6 and do not exceed the noise limit for emergency
condition.
Advisian Page 28 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Sensitivity Case 2 is carried out to identify the required minimum stack height for the new HP flare
stack if a tip diameter of 812.8 mm (32’’) is used. The flaring load is maintained at 292350.2 kg/hr
(10.05 MMscmd).
The minimum height of the new HP flare stack to meet the thermal radiation acceptance criterion
at all receptor points is 50.1 m. Table 4-7 summarises the thermal radiation levels at each receptor
point. The graphical outputs of thermal radiation contour are shown in Figure 4-16 and 4-17.
Sensitivity Case 2
Thermal Radiation
Receptor Receptor Point Acceptance 2
(kW/m )
2 Acceptance
Point ID Description Criteria (kW/m )
27.5/D
New HP Flare
RP_1 6.31 6.31 Acceptable
Stack Base
Sterile Area
RP_2 Boundary Plant 6.31 6.03 Acceptable
North
Sterile Area
RP_3 Boundary Plant 6.31 3.92 Acceptable
East
Sterile Area
RP_4 Boundary Plant 6.31 4.00 Acceptable
West
Sterile Area
RP_5 Boundary Plant 6.31 2.94 Acceptable
Southwest
Advisian Page 29 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-16: Plan View of Thermal Radiation Contour at 27.5 m/s Wind Speed (Sensitivity
Case 2)
Advisian Page 30 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-17: Elevation View of Thermal Radiation Contour at 27.5 m/s Wind Speed
(Sensitivity Case 2)
Figure 4-18 shows that the 50% LFL and 100% LFL flammable gas clouds at stack height of 50.1 m
do not descend downwards encroaching the receptor points at ground level.
Advisian Page 31 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Figure 4-18: Flammable Gas Dispersion of Sensitivity Case 2 at 27.5/D Weather Condition
4.4.3 Noise
The noise limit for emergency condition is 115dB(A) at all receptor points. The noise levels at
receptor points for Sensitivity Case 2 are shown in Table 4-8 and do not exceed the noise limit for
emergency condition.
Sensitivity Case 2
Advisian Page 32 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
4.5 Summary
Table 4-9 summarises the findings of the Flare study for all cases.
Case 1
8.3 m/s 49.5 m 3.0 m 914.4 mm (36’’) 162.9 m/s Met for all receptor
points
27.5 m/s 49.5 m 3.0 m 914.4 mm (36’’) 162.9 m/s Exceeded at 7.05
2
kW/m and 6.80
2
kW/m at the stack
base and sterile area
boundary at Plant
North respectively.
Sensitivity Case 1
8.3 m/s 49.5 m 3.0 m 812.8 mm (32‘’) 206.1 m/s Met for all receptor
points
27.5 m/s 49.5 m 3.0 m 812.8 mm (32‘’) 206.1 m/s Exceeded at 6.38
2
kW/m at the stack
base.
Case 2
8.3 m/s 45.3 m 3.0 m 914.4 mm (36’’) 162.9 m/s Met for all receptor
points
27.5 m/s 55.6 m 3.0 m 914.4 mm (36’’) 162.9 m/s Met for all receptor
points
Advisian Page 33 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Sensitivity Case 2
8.3 m/s 41.0 m 3.0 m 812.8 mm (32‘’) 206.1 m/s Met for all receptor
points
27.5 m/s 50.1 m 3.0 m 812.8 mm (32‘’) 206.1 m/s Met for all receptor
points
The maximum allowable noise limit during emergency condition of 115 dB(A) is not exceeded for
all study cases analysed.
The extent of the 50% LFL and 100% LFL flammable gas clouds for all study cases do not descend
downwards encroaching the receptor points at ground level.
Advisian Page 34 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
5 Conclusion
Flare study has been performed for the new HP flare at ONGC KG-DWN-98/2 MEG Facility. The
following conclusions are made:
The new HP flare stack height will need to be 55.6 m if a tip of 914.4 mm (36’’) diameter is
used. This is to maintain the sterile area boundary radius of 90 m and satisfy the thermal
radiation acceptance criterion at all receptor points.
A minimum of flare stack height 50.1 m is required for the new HP flare if a smaller tip
812.8 mm (32’’) diameter can be used. This is to ensure the thermal radiation criterion is
met and to maintain the sterile area boundary radius of 90 m.
Based on a minimum height of 49.5 m flare stack with a 32’’ flare tip diameter (as per
2
existing HP flare at Vashishta) the thermal radiation criterion of 6.31 kW/m is marginally
2
exceeded with a calculated value of 6.38 kW/m .
The maximum allowable noise limit during emergency condition of 115 dB(A) is not
exceeded for all study cases analysed.
Gas dispersion study cases show that the extent of 50% LFL and 100% LFL flammable gas
clouds do not descend downwards encroaching the receptor points at ground level
regardless of the wind conditions.
Flare vendor to verify results and confirm flare tip size and hence flare height.
Advisian Page 35 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
6 References
6.1 International Codes and Standards
1. API STD 521, Guide for Pressure-Relieving and Depressuring Systems, January
2014.
th
6. Email received from Mustafa Mahmood on 19 March 2018 (Composition for
Flaresim- addition of HP Separator + Inlet Separator)
th
7. Email received from Mustafa Mahmood on 22 March 2018 (Flarenet and Flare
KOD Summary Results (revised))
th
8. Email received from Mustafa Mahmood on 26 March 2018 (ONGC Flare Study)
Advisian Page 36 of 38
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Advisian i
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
Advisian ii
Oil and Natural Gas Corporation Limited
Flare Study For ONGC KG-DWN-98/2
MEG Facility
2.9E04 kg/hr
Mass flow
(10.05 MMscmd)
Nitrogen 0.008620
CO2 0.002182
Methane 0.976290
Ethane 0.006200
Propane 0.003240
i-Butane 0.000670
n-Butane 0.001029
i-Pentane 0.000295
n-Pentane 0.000236
n-Hexane 0.000180
n-Heptane 0.000020
n-Octane 0.000000
n-Nonane 0.000000
n-Decane 0.000000
H2O 0.000283
Oxygen 0.000920
TEGlycol 0.000000
EGlycol 0.000000
Advisian iii
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 61 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 62 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 63 of 74
1
Page 1 of 5
2
18. 1
Reid vapor pressure thermostatic controlled water bath and stirrer
19. Refrigerator 250 lts 1
Oil Viscosity test kit
20. 1
Gerin Kit
21. Fann - V.G. meter 6 speeds working on 220V/50Hz 2
22. Mettler analytical balance 1
Density Hydrometer (Type L50S) with calibration certificates
a) Range 0.70-0.75 6
b) Range 0.75-0.80 6
c) Range 0.80-0.85 6
d) Range 0.80-0.95 6
23.
e) Range 0.90-1.05 6
f) Range 1.00-1.05 6
g) Range 1.1-1.3 6
h) Range 1.3-1.5
6
Hot air oven - Accuracy + 10C Temp. (Control + Safety) 120 litres, with removable
34. 1
S.S. Trays.
Page 2 of 5
3
High pressure Oil & Gas sampler Capacity – 500CC pressure rating = 3000 psi sour 10 no’s
35.
service application (CO2 = 6.9% H2S = 1100 ppm, chloride = 28000 ppm each
36. FT IR Spectrophotometer / Perkin Elmer/MERK 01 no’s
Automated Particle size Analyser (For NAS Specification testing) Pamas/Spectrex 02 no’s
37.
Water section
5. Calibration standards and Standard Reagent solutions of commonly determined 5 no’s each
ions by using spectro photometer with SL.No. 4
6. All Glass distillation unit with quick-fit joints, round bottom flash capacity, 2000 06 no’s
ml. with sunwick control heating mantle
7. Turbidity meter : 2
Each Model 2100 A with calibration Standards and following spares: 2
i) Spare parts kit, Model 2100 A 2
ii) Fuse, 3/4 amp., slo-blo (5) 2
iii) Lamp Assembly (1) 2
iv) Sample Cell 4
v) Tube, Photomultipliers (1) 2
Vendor : LOVIBOND/ HACH Company
8 MF-Millipore Filter, 0-45 mm pore Size, 47 mm diameter, colour white, 100 filters 50
per package. Packages
Curtain Matheson scientific Inc.
Cat No. HAWP - 04700
0-22 mm pore size 47 mm diameter, 100 filters per package. 10 Packages
9 In-line Millipore filter Holder 47 mm 6
10 Lovibond Comparator -2000+ 2
11 Square Cuvettes (13.5 mm) for Sl. No, 10 12
12 Colour Disc. for chlorine 3/2A 6
Page 3 of 5
4
temperature uniformity + 0250C, control and sensitivity + 0.50C complete with dual
temperature safety thermostat, stainless steel diffuser plate, thermometer, and
holder, circuit breaker and 3-wire cord and plug 220V/50Hz.
16 Fume Hood complete with exhaust fan, exhaust fan switch, two electric outlets, 1
stainless steel sink, and four remote controls for hot water, cold water, gas and
vacuum (in accordance with specification sheet WIN-6050 "Laboratory Fume
Hood”) outside dimensions:
1829 mm Height X 346 mm Width X 915 mm depth
Inside dimensions:
1575 mm Height X 1194 mm Width X 711 mm depth
17 Vacuum pump, model D-25, two stage 1.3 H.P., One litre/minute capacity. 1
18 Pressure Gauges 10
SS-316 Borudon tube, 21/2" dial glycerine filled entry from bottom, 1/4" NPT
Range 0-70 psi.
19 Field testing kits by CHEMetrics
i) dissolved oxygen kit 10 Kits
Page 4 of 5
5
32. Industrial Water distillation plant for demineralized water (Min. 100 Liters per day) 02 no’s
33. Desktop Computer 02 no’s
Refer _____ for Specification
Page 5 of 5
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 64 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 65 of 74
Project: KG DWN 98/2 Project Development
Case: Production Year 2020 - 11.46 MMSCMD
TOTAL
Vapour Fraction 1.0000 1.0000 1.0000 1.0000 0.0000 1.0000
o
Temperature C 55.00 30.00 30.00 29.91 29.96 29.13
Pressure bar g 85.80 62.00 62.00 61.80 61.90 60.00
Molar Flow kgmol/h 3524.44 16670.59 20195.03 20195.03 0.00 20195.03
Mass Flow kg/h 62697.51 291073.52 353771.03 353771.03 0.00 353771.03
Molecular Weight kg/kmol 17.79 17.46 17.52 17.52 18.02 17.52
3
Mass Density kg/m 64.65 50.45 50.59 50.43 847.08 49.00
Heat Flow MW -76.17 -358.15 -435.07 -435.07 0.00 -435.07
Mass Enthalpy kJ/kg -4373.5 -4429.6 -4427.3 -4427.3 -15859.3 -4427.3
GAS PHASE
Molar flow kgmol/h 3524.44 16670.59 20195.03 20195.03 --- 20195.03
Mass Flow kg/h 62697.51 291073.52 353771.03 353771.03 --- 353771.03
3
Act Volume Flow Am /h 969.79 5769.93 6992.87 7014.86 --- 7219.35
Std Gas Flow MMSCMD 2.00 9.46 11.46 11.46 --- 11.46
Std Gas Flow MMSCFD 70.63 334.08 404.71 404.71 --- 404.71
Molecular Weight kg/kmol 17.79 17.46 17.52 17.52 --- 17.52
o
Mass Heat Capacity kJ/kg C 2.72 2.65 2.64 2.64 --- 2.63
3
Mass Density kg/m 64.65 50.45 50.59 50.43 --- 49.00
o
Thermal Conductivity W/m K 0.0449 0.0394 0.0394 0.0394 --- 0.0391
Viscosity cP 0.0146 0.0131 0.0131 0.0131 --- 0.0130
Z Factor 0.8755 0.8653 0.8657 0.8659 --- 0.8678
Cp / Cv 1.507 1.522 1.520 1.519 --- 1.514
OIL PHASE
Molar Flow kgmol/h --- --- --- --- --- ---
Mass Flow kg/h --- --- --- --- --- ---
3
Act Volume Flow Am /h --- --- --- --- --- ---
Std Liquid Flow barrel/day --- --- --- --- --- ---
o
Mass Heat Capacity kJ/kg. C --- --- --- --- --- ---
3
Mass Density kg/m --- --- --- --- --- ---
o
Thermal Conductivity W/m. K --- --- --- --- --- ---
Viscosity cP --- --- --- --- --- ---
Surface Tension dynes/cm --- --- --- --- --- ---
AQUEOUS PHASE
Molar Flow kgmol/h --- --- --- --- 0.00 ---
Mass Flow kg/h --- --- --- --- 0.00 ---
3
Act Volume Flow Am /h --- --- --- --- 0.00 ---
Std Liquid Flow barrel/day --- --- --- --- 0.0 ---
o
Mass Heat Capacity kJ/kg C --- --- --- --- 4.306 ---
3
Mass Density kg/m --- --- --- --- 847.08 ---
o
Thermal Conductivity W/m K --- --- --- --- 0.6182 ---
Viscosity cP --- --- --- --- 0.798 ---
Surface Tension dynes/cm --- --- --- --- 71.24 ---
Project: KG DWN 98/2 Project Development
Case: Production Year 2020 - 11.46 MMSCMD
www.advisian.com
Page 66 of 74
Calculation Cover Sheet
Calculation Method
In-house WP 2-phase vertical separator spreadsheet.
Assumptions
See content
Software Used
Title Version Validation (Y / N / N/A)
SeleXpress 3.2.1.92 Y
References
1. Process Design Basis - CPP/LQUP Rev. 0B (Doc. no.: 402020-01391-06-PR-BOD-0001)
2. Flow Assurance Report - Cluster 2B Gas Fields Rev. 0D (Doc. no.: 402020-01391-02-SY-REP-0002)
3. Heat & Material Balance: Case 1 (FF Mode - Year 2020) (Dwg. no.: 402020-01391-06-PR-PFD-0101)
4. DEP 31.22.05.11 - Gas/Liquid Separators - Type Selection and Design Rules
Conclusions
Selected Vessel Size Selected Nozzle and Line Size
Vessel ID = 2900 mm Inlet nozzle size = 30"
Vessel T/T = 5800 mm Inlet line size to vessel = 20"
Vessel Weight (per unit) = 72.3 te Gas outlet nozzle size = 24"
Gas outlet line size from vessel = 20"
Liquid outlet nozzle size = 2"
Liquid outlet line size = 2"
Table of Contents
Objective 4
Method 4
Assumptions 4
Fluid Properties and Details 5
Nozzle Sizing 6
Vessel Height Determination 7
Vessel Weight Calculation 7
Vessel Sketch 10
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Method:
In-house WP 2-phase vertical separator spreadsheet.
Assumptions:
1. Composition for incoming Cluster 1 gas with flowrate of 2 MMSCMD is based on from HMB stream 170.
2. Onshore gas design flowrate is 9.46 MMSCMD.
3. Gas Separator inlet condition is 62 barg and 30 degC.
4. No margin is applied on 2 x 100% vessel sizing.
5. Gas load factor, k value of 0.08 m/s is assumed for vessel with demister.
6. Level setting criteria for vertical separator sizing is as recommended in DEP 31.22.05.11
7. Demister thickness of 150mm is assumed.
Parameter Criteria
LAHH to bottom of inlet nozzle 0.35 x vessel diameter
LAH to LAHH Minimum 100 mm or 1 - 2 minutes for action in control room; 5 minutes for outside
of control room
LAL to LAH Minimum 350 mm or 3 minutes holdup time
LALL to LAL Minimum 100 mm or 1 - 2 minutes for action in control room; 5 minutes for outside
of control room
Bottom tan line to LALL Minimum 250 mm
L/D 2 ≤ L/D ≤ 6
8. Nozzle sizing criteria for Gas Separator is as follows:
Nozzle Criteria
Inlet ρV2 < 1400 Pa (no inlet device)
Vapour Outlet ρV2 < 3750 Pa
Liquid Outlet Velocity < 1 m/s
9. Pressure drop across Gas Separator is 0.2 bar.
10. Inlet pressure of 61 barg to Gas Metering Skid at downstream of Gas Separator is assumed.
Conclusion:
Selected Vessel Size Selected Nozzle and Line Size
Vessel ID = 2900 mm Inlet nozzle size = 30"
Vessel T/T = 5800 mm Inlet line size to vessel = 20"
L/D = 2.0 Gas outlet nozzle size = 24"
Gas outlet line size from vessel = 20"
Selected Level Setting Liquid outlet nozzle size = 2"
LAH - LAHH = 150 mm Liquid outlet line size = 2"
LAL - LAH = 350 mm Pressure drop between Gas Separator outlet and Gas
LALL - LAL = 100 mm Metering skid is 0.5 bar based on selected line size.
BOV - LALL = 300 mm
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Liquid Outlet:
Liquid Outlet Stream = Liq outlet
Liquid volumetric rate = 0.0 m³/s Manual entry
Liquid density = 847.1 kg/m³ HYSYS
Liquid density used = 847.1 kg/m³ HYSYS
Volume fraction light liquid = 0.00 Manual entry
(note: if light liquid fracton is above 0.05 then the light liquid density is used for the average liquid density)
Total liquid rate at P and T = 0.00 m3/s = 0.2 m3/d Manual entry
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
= 3.97
= 0.31 m/s
= 2.81 m
Nozzle Sizing:
Inlet nozzle:
Maximum ρv2 = 1400 kg/m.s²
Minimum size inlet nozzle (NB) = 685.67 mm
Selected inlet nozzle (NB) = 750.00 mm
Selected schedule = 30
Selected inlet nozzle ID = 730.25 mm
Inlet nozzle velocity = 4.65 m/s
Calculated ρv2 = 1095 kg/m.s²
Nozzle size check: Nozzle size acceptable
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
where the definitions are the same as previously, except for K which is a factor for elliposidal heads based on the
end proportion D/2h - for this calculation K is taken as 1.
Therefore, using the values as before the minimum head thickness = 72.86 mm
The corrosion/cladding allowance is added and then a 10% margin added to give a required minimum thickness of
83.44 mm
The closest standard plate thickness to be used is 84.00 mm
Weight Calculation:
The steel volume of the shell is calculated from:
Head perimeter =
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
0.44 m
0.15 m
2.9 m
2.62 m
730.25 mm
Selected height: 5.80 m
Calculated height: 5.12 m
60 s = 0.15 m
90 s = 0.18 m
90 s = 0.18 m
60 s = 0.10 m
h5 = 0.30 m
Inlet
Flow = 98.27 kg/s
Density = 50.6 kg/m³
Min. Size = 685.67 mm Liquid Outlet
NB Size = 750.00 mm Flow = 0.00 kg/s
ρv2 = 1095 kg/m.s² Density = 847 kg/m³
Velocity = 4.65 m/s Velocity = 0.00 m/s
Min. Size = 1.88 mm
NB Size = 50.00 mm
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
Appendix A
Vessel Sizing
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
A 21/03/18 CST
Height to top tan line = 435 mm 150 mm 0.15 x diameter or specified min
Demister (Y/N) = Y
Inlet nozzle height = 750 mm inlet nozzle ID
Height to inlet from LAHH = 870 mm 300 mm 0.3 x diameter or specified min
Specified Min.
Height LAH to LAHH = 150 mm 150 mm specified hold up time or specified min
Height NLL to LAH = 200 mm 200 mm half specified holdup or specified min, and slug volume
Height LAL to NLL = 200 mm 200 mm half specified holdup or specified min
Height LALL to LAL = 150 mm 150 mm specified hold up time or specified min
Note
Slug Volume is 0.0 % of Control Volume between NLL and LAH.
Appendix B
Line Sizing
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
A 23/3/18 CST
Line Number =
Mixture Mass Flow Rate = 353771.0 kg/h
3
Actual Mixture Density = 50.59 kg/m
Pipe Internal Diameter = 431.80 mm
Equivalent Length = 220.0 m
C-Factor (in SI units; see below) = 122
2
Pipe Cross-sectional Area = 0.1464 m
3
Actual Volumetric Flow Rate = 6992.87 m /h
Mixture Velocity = 13.26 m/s
Erosional Velocity = 17.15 m/s
Pressure Drop = 15.46 kPa/100m
= 34.01 kPa
ASSUMPTIONS
1) The Moody friction factor is assumed to be an average of 0.015. At low velocities this requires verification. [Ref.1]
2) The empirical constant for erosional velocity (SI units) has the following recommended values: [Ref.1]
- Solids-free, continuous service 122
- Solids-free, intermittent service 152.5
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; continous service 183 - 244
- Solids-free, inhibition or corrosion resistant alloys or no corrosion; intermittent service up to 305
3) The table in 2) is in accordance with API RP 14E. Subsequent review by independent oil and gas operators and scientists
has demonstrated that this table is highly conservative and even shows a reverse trend with mixture density.
For solids-free liquid impingement erosion a C-factor of 366 may be assumed. [Ref.2]
4) According to Ref.3, errors of up to ± 20% may normally be anticipated on calculated pressure drop.
Verification using approved modelling software should be considered during detailed design.
5) Though based on an offshore code, the above methodology is applicable to onshore piping subject to the stated constraints.
REFERENCES
1) API RP 14E, "Recommended Practice for Design and Installation of Offshore Production Platform Piping Systems", 5th Ed., 1-Oct-91
2) M.M Salama and E.S Venkatesh, "Evaluation of API RP 14E Erosional Velocity Limitations of Offshore gas Wells",
OTC 4485, 15th Annual OTC in Houston, May 1983
Appendix C
Hysys Properties
This Calculation represents the work of WorleyParsons performed to recognized engineering principles and practices appropriate for the terms of reference provided by WorleyParsons contractual
Customer. This Calculation is confidential and prepared solely for the use of the Customer. The contents of this Calculation may not be disclosed to or relied upon by any party other than the Customer,
and neither WorleyParsons , its subconsultants nor their respective employees assume any liability for any reason, including, but not limited to, negligence, to any other party for any information or
representation herein.
002-000-PDF-566 (015311) EPF-0027
www.advisian.com
Page 67 of 74
M
M M
V-N78151
M
V-N78152A
M
V-N78152B
M M M M
A-N77151A
M M M M
A-N77151B
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 68 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0A
Drawing List
Page 69 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 70 of 74
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 71 of 74
3:51 PM 3/28/2018
Rev 6.5
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x50%
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KG DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR:
Cover Sheet 28-Mar-18 Total Pages: 8 Plus Cover, TOC & Checklist
(a) Calculation Objective
(b) Assumptions
(c) References
1. API STANDARD 521 - Pressure-relieving and Depressuring Systems (6th edition, January 2014)
2. Heat and Material Balance (Doc. No.: 402020-01391-06-PR-PFD-0101)
3. OFFSHORE DESIGN GUIDE WS-DG-PR-007 (Relief & Blowdown Calculations)
4. OFFSHORE DESIGN GUIDE WS-DG-PR-016 (Depressuring and Low Temperature Studies)
5. OFFSHORE DESIGN GUIDE WS-DG-PR-020 (Flare, Relief, Blowdown & Vent System Design)
(d) Conclusions
Perunding Ranhill Worley Calculation Pad 1 of 3 01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note - Calc Cover
2:22 PM 3/27/2018
Note:
Change
Row height
Youcells
can
is with
50
copy
for
a
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KG DWN 98/2 Part III Proj No:
Client: ONGC Phase/CTR:
Table of Contents Page: 2 Plus Cover, TOC & Checklist
(e) Table of Contents Page Row
Rev
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 27/3/2018 Issued for Review CST MM 27/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 2 of 9 01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note - Calc Cover
2:22 PM 3/27/2018
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KG DWN 98/2 Part III Proj No:
Client: ONGC Phase/CTR:
Checklist Page: 3 Plus Cover, TOC & Checklist
(f) Check List
Rev
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available in addition to software version.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification checked.
Checking records:
Checked and annotated copy of calculation filed (use "Document Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 27/3/2018 Issued for Review CST MM 27/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 3 of 9 01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note - Calc Cover
2:22 PM 3/27/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X 27-Mar-18 Page: 4 of 8
Rev
1.0 OBJECTIVES
1. To calculate the blowdown load from 2 x 100% Gas Separator during emergency shutdown
2. To check minimum temperature achievable during blowdown scenario
3. To size the blowdown RO for the new Gas Separator BDV
3.0 METHODOLOGY
HYSYS Dynamic Depressuring Utiility from ASPEN HYSYS V8.8 is used to determine the peak blowdown load and the minimum temperature
achievable during blowdown scenario.
In-house line sizing spreadsheet is used to size the inlet line while Aspen Flare System Analyzer v8.8 is used to model the flare network.
Rev: A Page: 4 of 8
Perunding Ranhill Worley Calculation Pad 4 of 9 01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note - 4
2:22 PM 3/27/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X 27-Mar-18 Page: 5 of 8
Rev
Based on above results, fire case blowdown at LAL is the governing scenario with peak load at 1.1 MMSCMD.
Minimum temperature at valve outlet is at -14 oC. Hence, design temperature of -29 oC is adequate for this system.
Rev: A Page: 5 of 8
Perunding Ranhill Worley Calculation Pad 5 of 9 01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note - 5
2:22 PM 3/27/2018 6 of 9
Attachment A 1
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X Include Attachment in Print List: X 27-Mar-18 Page: 6 of 8
Attchmt: A GAS SEPARATOR BLOWDOWN INVENTORY +File:Attachment Identifier: A
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 6 of 8
SDV @ feed inlet Gas Separator 20 120 508 38.10 431.8 20000 1 27.13 2.93 0.0000 3.51 0.00 3.51 32.56 0.00
Gas Separator SDV @ gas outlet 20 120 508 38.10 431.8 10000 1 13.57 1.46 0.0000 1.76 0.00 1.76 16.28 0.00
Gas Separator SDV @ liquid outlet 2 160 50.8 8.74 33.3 10000 1 1.05 0.01 1.0000 0.01 0.01 0.00 1.26 1.26
Gas Separator (LAH) 84.0 2900 5800 1 71.07 44.70 - 44.70 3.36 41.34 71.07 9.34
SDV @ feed inlet Gas Separator 20 120 508 38.10 431.8 20000 1 27.13 2.93 0.0000 3.51 0.00 3.51 32.56 0.00
Gas Separator SDV @ gas outlet 20 120 508 38.10 431.8 10000 1 13.57 1.46 0.0000 1.76 0.00 1.76 16.28 0.00
Gas Separator SDV @ liquid outlet 2 160 50.8 8.74 33.3 10000 1 1.05 0.01 1.0000 0.01 0.01 0.00 1.26 1.26
Gas Separator (LAL) 84.0 2900 5800 1 71.07 44.70 - 44.70 1.19 43.51 71.07 9.12
Attachment B 2
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X Include Attachment in Print List: X 27-Mar-18 Page: 7 of 8
Attchmt: B GAS SEPARATOR BDV HYSYS BLOWDOWN CALCULATION Attachment+File: Identifier: B
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 7 of 8
Attachment C 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Blowdown\[01410 IAPSB-PR-CAL-0011 - 2x100% Blowdown Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator BDV Sizing Calculation Calc Number: PR-CAL-0011
Project Title: KeywordPerundingRanhillWorleyPortrait
KG DWN 98/2 Part III TRUE Proj No:
Client: ONGC Phase/CTR:
Include sheet in TOC: X Include Attachment in Print List: X 27-Mar-18 Page: 8 of 8
Attchmt: C BDV Inlet Line Sizing +File: Attachment Identifier: C
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 8 of 8
Line/Unit No:
Units SI SI SI SI SI
Phase Gas Gas Gas Gas Gas
Diameter, Nominal 150.00 mm mm mm mm mm
Type of Pipe Commercial Steel Commercial Steel Commercial Steel Commercial Steel Commercial Steel
Pipe Schedule Sch 120 Std Sch 40 Sch 40 Sch 80
Pipe Class Optional Override Optional Override Optional Override Optional Override Optional Override
User can override WT/ID Incorrect Schedule No. Incorrect Schedule No. Incorrect Schedule No. Incorrect Schedule No.
O.D.,mm User Input User Input User Input User Input User Input
WT., mm User Input User Input User Input User Input User Input
I.D. / W.T.,mm 139.73 14.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Flow Type Mass Mass Mass Mass Mass
Actual Flowrate 32875 kg/h kg/h kg/h kg/h kg/h
Inlet Temperature 30 °C °C °C °C °C
Inlet Pressure 8101.325 kPaa kPaa kPaa kPaa kPaa
Pressure Linked to previous line Link from Line 1 Outlet Pressure Link from Line 2 Outlet Pressure Link from Line 3 Outlet Pressure Link from Line 4 Outlet Pressure
Inlet Pressure 8101.325 kPaa 0 kPaa 0 kPaa 0 kPaa 0 kPaa
Molecular Weight 17.52
Compressibility Not required
Gas k Value at Outlet (CP / CV) 1.601
User Defined Density 67.3 kg/m3 kg/m3 kg/m3 kg/m3 kg/m3
(User can override density) (User can override density) (User can override density) (User can override density)
Density 67.300 kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3
Viscosity 0.01386 cP cP cP cP cP
Design Margin % % % % %
Eq Lengths Eq Lengths Eq Lengths Eq Lengths Eq Lengths
Elbows / Bends / Tees No. metres No. metres No. metres No. metres No. metres
Elbow 90° (LR) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Elbow 45° (LR) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Bend 90°, R = 5D 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Bend 180°, R = 5D 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Tee Through 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Tee 90° Branch 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Valves
Ball (red. bore 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Ball (red. bore 50 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Gate (std. bore) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Gate (red. bore 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (straight pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (Y pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (angle pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Check (swing type) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Check (ball or piston 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Plug (regular) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Butterfly ( 150 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Strainer (Y and Bucket Type) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Enlargers & Reducers
Nominal Size (upstream) mm mm mm mm mm
Nominal Size (downstream) mm mm mm mm mm
Reducer 0.00 0.00 0.00 0.00 0.00
Enlarger 0.00 0.00 0.00 0.00 0.00
Entrance & Exits
Entrance - Inward Projecting 1 7.11 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Entrance - Flush 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Exits - All cases 1 9.11 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
User Defined K Value & DP
K Value for Fitting 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Pressure Drop: Item 1 kPa kPa kPa kPa kPa
Pressure Drop: Item 2 kPa kPa kPa kPa kPa
Fittings Eq. Length, m 16.21 #VALUE! #VALUE! #VALUE! #VALUE!
Pipe Straight Length 20 m m m m m
Total Eq. Length, m 36.21 #VALUE! #VALUE! #VALUE! #VALUE!
Elevation Change m m m m m
CALCULATED VALUES: SI Results SI Results SI Results SI Results SI Results
Mass Flow 32875.00 kg/h 0.00 kg/h 0.00 kg/h 0.00 kg/h 0.00 kg/h
Actual Vol. Flow Rate 488.48 m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h
Static Head Loss 0.00 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Reynolds No. 6003918 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Moody Friction Factor 0.0153 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Pressure Drop 28.92 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m
Design Pressure Drop 28.92 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m
Inlet Velocity 8.85 m/s 0.00 m/s 0.00 m/s 0.00 m/s 0.00 m/s
Design Total Drop 10.47 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Cumulative Design Total Drop 10.47 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Inlet Press 8101 kPaa 0 kPaa 0 kPaa 0 kPaa 0 kPaa
Outlet Press 8091 kPaa #DIV/0! kPaa #DIV/0! kPaa #DIV/0! kPaa #DIV/0! kPaa
Outlet Density 67.21 kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3
Outlet Vol Flow 489.12 m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h
Outlet Velocity 8.86 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Pressure Drop/Inlet P 0.13 % #DIV/0! % #DIV/0! % #DIV/0! % #DIV/0! %
VELOCITY CHECK
Noise Limit 23.59 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Sonic Velocity at Outlet (Vs) 479.93 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Erosional Velocity Limit : C 122 100 122 122 122
Ve 14.87 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
WARNINGS: #DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
www.advisian.com
Page 72 of 74
3:53 PM 3/28/2018
Rev 6.5
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x5
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Cover Sheet 28-Mar-18 Total Pages: 7 Plus Cover, TOC & Checklist
(a) Calculation Objective
To document the PSV and inlet line sizing calculation for 2 x 100% Gas Separators relief scenario during external fire.
(b) Assumptions
(c) References
1. API STANDARD 521 - Pressure-relieving and Depressuring Systems (6th edition, January 2014)
2. API STANDARD 526 - Flanged Steel Pressure-relief valves (6th edition, April 2009)
3. Heat and Material Balance
4. OFFSHORE DESIGN GUIDE WS-DG-PR-007 (Relief & Blowdown Calculations)
(d) Conclusions
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note - Calc Cover
3:53 PM 3/28/2018
Note:
Change
Row height
Youcells
can
is with
50
copy
for
a
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x50% PSV Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Table of Contents Page: 2 Plus Cover, TOC & Checklist
(e) Table of Contents
Rev
Page Row
Heading: No: Worksheet Name: No:
Cover, TOC & Checklist 1 1
1.0 OBJECTIVE 2 4
2.0 INTRODUCTION 2 4
3.0 METHODOLOGY 2 4
4.0 RESULTS 5 4
Attachment A: Gas Separator Hysys Properties 5
Attachment B: Gas Separator PSV Sizing Calculation 6
Attachment C: PSV Inlet Line Sizing 7
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 16/3/2018 Issued for Review CST MM 16/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note - Calc Cover
3:53 PM 3/28/2018
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x50% PSV Calculation Note.xls]Calc Cover
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Checklist Page: 3 Plus Cover, TOC & Checklist
(f) Check List
Rev
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available in addition to software version.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification checked.
Checking records:
Checked and annotated copy of calculation filed (use "Document Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 16/3/2018 Issued for Review CST MM 16/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note - Calc Cover
3:34 PM 3/27/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note.xls]Methodology
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KG-DWN 98/2 Part III
KeywordPerundingRanhillWorleyPortrait TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: x 27-Mar-18 Page: 4 of 7
Rev
1.0 OBJECTIVE
To document the PSV and inlet line sizing calculation for 2 x 100% Gas Separators relief scenario during external fire.
1. The following summarizes input parameter for fire scenario of Gas Separator during overpressure.
Initial Pressure = Design Pressure of vessel
Initial Temperature = Normal operating temperature
2. Only one operating Gas Separator will be considered in this calculation.
3. Design pressure of Gas Separator is 80 barg.
4. Production fluid arrival conditions of Gas Separator is at 62 barg and 30 ⁰C.
5. Gas Separator dimensions are 2.9 m (ID) x 5.8 m (T/T) with thickness of 84 mm.
6. Gas Separator is assumed as dry vessel.
3.0 METHODOLOGY
1. For estimation of relief rate, the methodology given in API RP-520; API RP-521 shall generally apply, however the specific procedures, practices and
requirements as detailed in the following is considered.
2. In-house RWP line sizing spreadsheet is used to size the inlet line. While Aspen Flare System Analyzer v8.8 is used to model the flare network.
General
a. The possibility of two or more related emergency conditions ('multiple contigencies') shall not be evaluated.
b. No credit shall be taken for the presence of emergency instrumentation and the response of plant operators in determining relief requirement, except
in those instances allows for in the codes.
c. Flow rate through equipment and other conditions during the particular contigency shall be assumed to be at the maximum operating flow, except
where the contingency directly alters the flow. A standard exception is fire exposure where it is normally assumed that the equipment is blocked in,
ie. incoming and outgoing process flows are stopped.
d. No credit shall be taken for increased out-flow via a pressure controlled side stream due to action by the controller.
Fire
a. Vessel surface area is calculated based on total cylindrical area and 2:1 elipsoidal head unless specified.
b. For dry vessel API 521 eq. 12 based on gas expansion will be used to determine the relief load:
𝐴 𝑇 −𝑇 . Where:
𝑊 = 0.1406 𝑀 𝑃 . W = Relief flow Tw = Maximum vessel wall temperature
𝑇
M = Molecular weight T1 = Relief temperature
P1 = Relief pressure A' = Exposed surface area of the vessel
c. Relief load and required orifice area are calculated based on API 520 Part 1 equation 3.2.
4.0 RESULTS
PSV Sizing
Required Load 16245 kg/h
Required Relief Valve Area 308.8 mm2
Selected Relief Valve Area 324.5 mm2
Rated Load 17070 kg/h
PSV Size 1 1/2 G 3
Inlet Line
Criteria
Line Size DN100
Pressure Drop 19.58 kPa
3% 0.24% --> OK
Mass Density 50.59 kg/m³
Velocity < Ve 14.11 m/s --> OK
rhoV² 50000 10072 kg/m/s²--> OK
Rev: A Page: 4 of 7
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note - Methodology
3:34 PM 3/27/2018 5 of 7
Attachment A 1
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note.xls]Methodology
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KeywordPerundingRanhillWorleyPortrait
KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: X Include Attachment in Print List: X 27-Mar-18 Page: 5 of 7
Attchmt: A Hysys Properties +File: Attachment Identifier: A
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 5 of 7
Attachment B 2
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note.xls]Methodology
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KeywordPerundingRanhillWorleyPortrait
KG-DWN 98/2 Part III TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: X Include Attachment in Print List: X 27-Mar-18 Page: 6 of 7
Attchmt: B Gas Separator PSV sizing calculation +File: Attachment Identifier: B
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 6 of 7
A 26.3.18 CST MM
Attachment C 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\[01410 IAPSB-PR-CAL-0012 -2x100% PSV Calculation Note.xls]Methodology
Calculation Title: 2x100% Gas Separator PSV Sizing Calculation Calc Number: PR-CAL-0012
Project Title: KeywordPerundingRanhillWorleyPortrait
KG-DWN 98/2 Part III TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: X Include Attachment in Print List: X 27-Mar-18 Page: 7 of 7
Attchmt: C PSV Inlet Line Sizing +File: Attachment Identifier: C
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 7 of 7
Line/Unit No:
Units SI SI SI SI SI
Phase Gas Gas Gas Gas Gas
Diameter, Nominal 100.00 mm mm mm mm mm
Type of Pipe Commercial Steel Commercial Steel Commercial Steel Commercial Steel Commercial Steel
Pipe Schedule Sch 120 Std Sch 40 Sch 40 Sch 80
Pipe Class Optional Override Optional Override Optional Override Optional Override Optional Override
User can override WT/ID Incorrect Schedule No. Incorrect Schedule No. Incorrect Schedule No. Incorrect Schedule No.
O.D.,mm User Input User Input User Input User Input User Input
WT., mm User Input User Input User Input User Input User Input
I.D. / W.T.,mm 92.05 11.13 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Flow Type Mass Mass Mass Mass Mass
Actual Flowrate 17070 kg/h kg/h kg/h kg/h kg/h
Inlet Temperature 151.4 °C °C °C °C °C
Inlet Pressure 9781.325 kPaa kPaa kPaa kPaa kPaa
Pressure Linked to previous line Link from Line 1 Outlet Pressure Link from Line 2 Outlet Pressure Link from Line 3 Outlet Pressure Link from Line 4 Outlet Pressure
Inlet Pressure 9781.325 kPaa 0 kPaa 0 kPaa 0 kPaa 0 kPaa
Molecular Weight 17.52
Compressibility Not required
Gas k Value at Outlet (CP / CV) 1.333
User Defined Density 50.59 kg/m3 kg/m3 kg/m3 kg/m3 kg/m3
(User can override density) (User can override density) (User can override density) (User can override density)
Density 50.590 kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3
Viscosity 0.01688 cP cP cP cP cP
Design Margin % % % % %
Eq Lengths Eq Lengths Eq Lengths Eq Lengths Eq Lengths
Elbows / Bends / Tees No. metres No. metres No. metres No. metres No. metres
Elbow 90° (LR) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Elbow 45° (LR) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Bend 90°, R = 5D 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Bend 180°, R = 5D 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Tee Through 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Tee 90° Branch 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Valves
Ball (red. bore 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Ball (red. bore 50 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Gate (std. bore) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Gate (red. bore 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (straight pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (Y pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Globe (angle pattern) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Check (swing type) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Check (ball or piston 40 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Plug (regular) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Butterfly ( 150 mm) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Strainer (Y and Bucket Type) 0.00 #VALUE! #VALUE! #VALUE! #VALUE!
Enlargers & Reducers
Nominal Size (upstream) mm mm mm mm mm
Nominal Size (downstream) mm mm mm mm mm
Reducer 0.00 0.00 0.00 0.00 0.00
Enlarger 0.00 0.00 0.00 0.00 0.00
Entrance & Exits
Entrance - Inward Projecting 1 4.27 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Entrance - Flush 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Exits - All cases 1 5.48 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
User Defined K Value & DP
K Value for Fitting 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Pressure Drop: Item 1 kPa kPa kPa kPa kPa
Pressure Drop: Item 2 kPa kPa kPa kPa kPa
Fittings Eq. Length, m 9.75 #VALUE! #VALUE! #VALUE! #VALUE!
Pipe Straight Length 10 m m m m m
Total Eq. Length, m 19.75 #VALUE! #VALUE! #VALUE! #VALUE!
Elevation Change 3 m m m m m
CALCULATED VALUES: SI Results SI Results SI Results SI Results SI Results
Mass Flow 17070.00 kg/h 0.00 kg/h 0.00 kg/h 0.00 kg/h 0.00 kg/h
Actual Vol. Flow Rate 337.42 m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h
Static Head Loss 1.49 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Reynolds No. 3885499 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Moody Friction Factor 0.0168 #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Pressure Drop 91.62 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m
Design Pressure Drop 91.62 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m 0.00 kPa/100 m
Inlet Velocity 14.08 m/s 0.00 m/s 0.00 m/s 0.00 m/s 0.00 m/s
Design Total Drop 19.58 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Cumulative Design Total Drop 19.58 kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa #DIV/0! kPa
Inlet Press 9781 kPaa 0 kPaa 0 kPaa 0 kPaa 0 kPaa
Outlet Press 9762 kPaa #DIV/0! kPaa #DIV/0! kPaa #DIV/0! kPaa #DIV/0! kPaa
Outlet Density 50.49 kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3 #DIV/0! kg/m3
Outlet Vol Flow 338.10 m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h #DIV/0! m3/h
Outlet Velocity 14.11 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Pressure Drop/Inlet P 0.20 % #DIV/0! % #DIV/0! % #DIV/0! % #DIV/0! %
VELOCITY CHECK
Noise Limit 27.26 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Sonic Velocity at Outlet (Vs) 518.24 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
Erosional Velocity Limit : C 122 100 122 122 122
Ve 17.15 m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s #DIV/0! m/s
WARNINGS: #DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
#DIV/0! #DIV/0! #DIV/0! #DIV/0!
Std Calc: WS-CA-PR-001 Rev \3\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\PSV sizing\1-phase Inlet Line Sizing2x100% Date Printed: 3/27/2018
KG-DWN-98/2 PRE-FEED
Technical Bid Addendum 002 for Onshore MEG & Gas Pipeline
(OMF) Terminal under KG DWN 98/2 Development Project
Tender No. K07DC16051
Revision 0E
www.advisian.com
Page 73 of 74
3:19 PM 3/28/2018
Rev 6.5
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50%
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Cover Sheet 28-Mar-18 Total Pages: 8 Plus Cover, TOC & Checklist
(a) Calculation Objective
1. To perform BDV outlet line sizing at relief outlet of 2x50% Gas Separator during emergency depressurisation.
2. To perform PSV tailpipe sizing at relief outlet of 2x50% Gas Separator during overpressure due to external fire.
(b) Assumptions
(c) References
1. API STANDARD 521 - Pressure-relieving and Depressuring Systems (6th edition, January 2014)
2. API STANDARD 526 - Flanged-steel Pressure Relieving Valves (6th edition, April 2009)
(d) Conclusions
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Calc Cover
3:19 PM 3/28/2018
Note:
Change
Row height
Youcells
can
is with
50
copy
for
a
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Table of Contents Page: 2 Plus Cover, TOC & Checklist
(e) Table of Contents
Rev
Page Row
Heading: No: Worksheet Name: No:
Cover, TOC & Checklist 1 1
1.0 OBJECTIVE 2 4
2.0 INTRODUCTION 2 4
3.0 METHODOLOGY 2 4
4.0 RESULTS 5 5
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 28/3/2018 Issued for Review CST MM 28/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Calc Cover
3:19 PM 3/28/2018
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Checklist Page: 3 Plus Cover, TOC & Checklist
(f) Check List
Rev
Please check boxes for all applicable items checked or delete if not appropriate:
Calculations:
Source of input data stated (with revision number and date if relevant).
Assumptions stated.
Summary of results or conclusions if appropriate.
For software based calculations, reference to software verification if available in addition to software version.
Method clear and easy to follow.
Input data correct.
Calculation arithmetically correct OR software previously verified and reference to verification checked.
Checking records:
Checked and annotated copy of calculation filed (use "Document Check Print" stamp).
Corrections made as required and calculation dated and signed on cover sheet by checker.
Revisions:
Changes clouded.
Revision history block updated.
Calculation re-checked if required.
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
0 0-Jan-00 0 0 0 0-Jan-00
A 28/3/2018 Issued for Review CST MM 28/3/2018
REVISION REV DATE DESCRIPTION BY CHECKED CHECK DATE
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Calc Cover
3:19 PM 3/28/2018
Calculation Sheet 1
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KG-DWN 98/2 Part III
KeywordPerundingRanhillWorleyPortrait TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: x 28-Mar-18 Page: 4 of 8
Rev
1.0 OBJECTIVE
1. To perform BDV outlet line sizing at relief outlet of 2x50% Gas Separator during emergency depressurisation.
2. To perform PSV tailpipe sizing at relief outlet of 2x50% Gas Separator during overpressure due to external fire.
1. Flare header size of the Flare KO Drum gas outlet is 500 mm. Flare stack elevation of 53.5m is assumed.
2. Total gas outlet flowrate is 11.46 MMSCMD (353,771 kg/h).
3. Pressure drop of 0.1 bar across flare tip is assumed.
4. Flare gas outlet composition is based on combined gas flowrates of 2 MMSCMD from Cluster 1 and 9.46 MMSCMD from onshore.
Component Mole fraction
CO2 0.00188
Nitrogen 0.00790
Methane 0.94530
Ethane 0.01450
Propane 0.01883
i-Butane 0.00326
n-Butane 0.00478
22-Mpropane 0.00000
i-Pentane 0.00082
n-Pentane 0.00051
n-Hexane 0.00051
Mcyclopentan 0.00002
H2O 0.00049
NBP_-5* 0.00008
NBP_9* 0.00006
NBP_24* 0.00008
NBP_38* 0.00011
NBP_52* 0.00017
NBP_66* 0.00022
NBP_81* 0.00019
NBP_92* 0.00013
NBP_108* 0.00006
NBP_122* 0.00003
NBP_136* 0.00002
NBP_150* 0.00001
NBP_165* 0.00001
NBP_179* 0.00001
5. The following criteria were followed to determine the required tailpipe size.
- Maximum Mach no. in the tailpipe and subheader shall be kept below 0.8
- Maximum Mach no. in the main flare header shall be kept below 0.5
6. Maximum back pressure shall not exceed 150# piping design pressure which is the lowest pipe rating in the flare network.
3.0 METHODOLOGY
1. Flare network hydraulic calculations are performed using Aspen Flare System Analyser (Flarenet) Version 8.8.
2. The size of flare header is established by the governing flaring load and velocity calculations based on header Mach no. and the developed
backpressure.
3. Flare header length of 60 meter between Flare KO Drum and relief subheader from Gas Separator is assumed.
4. The following pressure drop approach has been considered in the Flarenet model:
- Single phase - Isothermal Gas
- Two phase - Beggs & Brill
5. Peng Robinson EOS was used for VLE calculations and Enthalpy calculations.
6. Flare headers shall be sized based on process load capacity. Mach number for vapour lines is calculated based on the API STD 521 equation 61:
Rev: A Page: 4 of 8
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Methodology
3:19 PM 3/28/2018
Calculation Sheet 9
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KG-DWN 98/2 Part III
KeywordPerundingRanhillWorleyPortrait TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: x 28-Mar-18 Page: 5 of 8
Rev
4.0 RESULTS
Below is the summary result from Flare Analyzer based on 20" flare header size.
Tailpipe size is selected to ensure that Mach number is kept below 0.8.
Rev: A Page: 5 of 8
Perunding Ranhill Worley Calculation Pad 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Methodology
3:19 PM 3/28/2018 6 of 8
Attachment A 1
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KeywordPerundingRanhillWorleyPortrait
KG-DWN 98/2 Part III Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: X Include Attachment in Print List: X 28-Mar-18 Page: 6 of 8
Attchmt: A Flarenet Model - Pipe length and diameter setup +File: Attachment Identifier: A
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 6 of 8
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 11.46 MMSCMD for 2x100% Gas Separator
Scenario : Case 2: 2x100% Fire Relief
Label : Length/Nom. Diameter /(m : - )
PFD
Attachment B 2
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KeywordPerundingRanhillWorleyPortrait
KG-DWN 98/2 Part III TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: X Include Attachment in Print List: X 28-Mar-18 Page: 7 of 8
Attchmt: B Flarenet Results - Gas Separator emergency depressurisation Attachment+File: Identifier: B
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 7 of 8
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 11.46 MMSCMD for 2x100% Gas Separator
Scenario : Case 1: 2x100% Blowdown
Label : Pres./Mach Number /(bar_g : - )
PFD
PFD
PFD
Attachment C 3
Cover Sheet
portrait
Electronic File location: \\myklarwdfs01v\MY\KLA\IntecSea\G\Projects\01410 IAPSB KG-DWN 98-2 Pre-FEED Part3\21.0 Working Folders\CST\Cluster 2B\Flarenet\[01410 IAPSB-PR-CAL-0013 -2x50% Tailpipe Sizing Calculation Note.xls]Methodology
Calculation Title: 2x100% Relief Outlet Line Sizing Calculation Calc Number: PR-CAL-0013
Project Title: KeywordPerundingRanhillWorleyPortrait
KG-DWN 98/2 Part III TRUE Proj No: 01410 IAPSB
Client: ONGC Phase/CTR: Pre-FEED
Include sheet in TOC: X Include Attachment in Print List: X 28-Mar-18 Page: 8 of 8
Attchmt: C Flarenet Results - Gas Separator fire relief scenario Attachment +File: Identifier: C
Rev
Attachment Worksheet:
Attachment Filename:
Attachment Author:
Rev: A Page: 8 of 8
Ranhill Worley Calculation Pad Portrait
Rev 1 01410 IAPSB-PR-CAL-0013 -2x100% Tailpipe Sizing Calculation Note - Attachments
Aspen Flare System Analyzer
Version34.0.0.109
User Name : Intecsea
Job Code :
Project : ONSHORE TERMINAL FOR VA & S1 DEVELOPMENT PROJECT
Description : Flare System Design - 11.46 MMSCMD for 2x100% Gas Separator
Scenario : Case 2: 2x100% Fire Relief
Label : Pres./Mach Number /(bar_g : - )
PFD
PFD
PFD
www.advisian.com
Page 74 of 74
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 1 of 10
GSPC ------------------------------
EIL------------------------------
Format No. EIL 1641-1924 Rev. 1 Copyright EIL – All rights reserved
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 2 of 10
TABLE OF CONTENTS
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 3 of 10
1.0 INTRODUCTION
1.1 Gujarat State Petroleum Corporation Ltd (GSPC) is the operator of the Deen Dayal Field
(Block KG-OSN/2001/03) situated offshore from the Yanam – Kakinada coast of Andra
Pradesh, India.
GSPC has discovered a significant reserve of gas in the Deen Dayal West (DDW) area
with the KG#8 exploration well located 15km offshore in 60 meters of water. The
reservoir is characterised by high temperature and high pressure.
The initial Deen Dayal Field Development is expected to consist of a Well Head Platform
(WHP), Process cum Living Quarter Platform, multiphase pipeline to shore and an
Onshore Gas Terminal (OGT). The pipeline route will be via the Goutami Godavari River
estuary to avoid encroaching on the Corangi Sanctuary.
The basis for the Integrated Field Development Strategy is to initiate the development
of the Deen Dayal Complex by building a production hub in the DDW area. As other
fault blocks (Deen Dayal North (DDN), Deen Dayal East (DDE)) are explored and
delineated, production pipelines resulting from development of these areas will be
routed through the DDW production Hub. All production gas from the Deen Dayal
complex will be gathered together at the DDW production Hub and exported to the
Onshore Gas Terminal at Mallavaram, East Godavari, Andhra Pradesh via a common
export pipeline (up to the pipeline maximum capacity).
UNIT CAPACITY
Gas Sweetening Unit
100 MMSCFD of slug catcher gas per
Gas Dehydration Unit
train
Dew Point Depression Unit
776 TPD (Slug catcher, GSU & DPDU
Condensate Stabilisation Unit
Condensate)
Sulphur Recovery Unit 753 kg/day (sulphur product)
1.2 Operating scenarios for Onshore Gas Terminal are listed below:
Case No. Case Description
Case-I Feed rate per train corresponding to 100 MMSCFD of slug catcher gas for
controlling case of CGR-5 (Condensate gas ratio-5)
Case-II Feed rate per train corresponding to 100 MMSCFD of slug catcher gas for
controlling case of CGR-20 (Condensate gas ratio-20)
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 4 of 10
1.3 Basic Engineering Design Basis (BEDB) for all facilities, containing technical information
as agreed between GSPC and EIL, shall be used for the process design and basic
engineering of process units/utility systems/offsite facilities. The BEDB for each facility
is divided in two parts:
Part-A: Unit Design Basis providing necessary data for a specific process
unit/utility system/offsite facility.
1.4 This document constitutes Part-A of the Basic Engineering Design Basis for Flare system.
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 5 of 10
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 6 of 10
Other failure case load can be due to blocked outlet, tube rupture, CV blow out full
open, PCV fail open etc. These failures are taken one at a time in the complex.
Following are the highest governing loads:
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 7 of 10
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 8 of 10
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 9 of 10
shall be maintained. It shall be steam traced as well. The line downstream of sour flare
KOD shall be of SS-304L material.
6.0 KNOCK-OUT DRUM
A) Hydrocarbon Flare Knock-out Drum
There shall be a main knock out drum (KOD) near HC flare stack for hydrocarbon flare.
This KOD shall collect blow downs from main HC flare, both HP & LP.
The main KOD near flare stack shall be provided with two no. electric motor driven
blow down pumps of 5 m3/hr capacity each (1 operating + 1 stand-by). These pumps
shall be provided near the main KOD to pump out liquid that accumulates in the drum
to slop tank. These pumps shall be provided with emergency power back-up and status
lamp indication in control room as well. The pumps shall be provided with auto
start/stop facility on high high level and low low level respectively.
Apart from main knockout drum (KOD) near the flare stack, individual units shall be
provided with a flare KOD within ISBL.
B) Acid Flare Knock-out Drum
There shall be a knock out drum (KOD) near the flare stack for acid flare. This KOD shall
collect blow down from the acid flare header and the same is to be routed to OWS.
7.0 WATER SEAL DRUM
A vertical water seal drum shall be provided at the bottom of the HC flare stack. The
water seal drum is an integral part of the HC flare stack. Thus it shall not be possible to
take water seal drum under maintenance without the shutdown of entire OGT complex.
Thus to avoid any such situation all the internals of water seal drum shall be of SS316L.
8.0 FLARE STACK
Flare stack components shall be designed for handling maximum flare load to minimum
purge gas rate. Flare stack shall be purged with fuel gas. Flare vendor to ensure
adequate velocity at flare stack tip during normal operation, with normal purge gas rate
in flare headers, such that the flame always remains outside the tip. No damage should
occur to tip due to burning inside the tip.
The flare stack shall have a molecular seal, flare tip and flame pilots.
The metallurgy of the hydrocarbon flare tip shall be considered as Incoloy 825.
The acid flare header shall be post weld heat treated and hardness of 200 BHN shall be
maintained. It shall be steam traced. The line downstream of sour flare KOD shall be of
SS-304L material. This line shall be provided with auxiliary fuel gas to combust acid
gases.
Acid flare riser material last 5m before and after bend shall be inconel 625. 1
The minimum stack height shall be such that the total radiation (flare radiation + solar
radiation) is within the API RP 521 permissible limit of 1500 Btu/hr.ft2, in areas where
emergency actions lasting 2-3 minutes can be required by personnel without shielding
but with appropriate clothing.
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar
Document No.
Basic Engineering Design Basis Part-A A043-02-41-PDB-89 Rev. 1
FLARE SYSTEM
Page 10 of 10
a) All hydrocarbon bearing discharges of all molecular weights from pressure relief/
pressure control devices shall be discharged to closed flare system.
b) Short term H2S rich reliefs from process units shall also be joined into hydrocarbon
flare.
c) The individual unit flare header sizing shall be done considering the maximum flare
load from among all the significant flare cases.
d) For HP HC flare a maximum allowable backpressure of 3.2 kg/cm2g at unit battery
limit shall be considered for sizing the main flare header. However, a maximum
allowable backpressure of 3.4 kg/cm2g shall be considered at PSV outlet of
respective units.
e) For LP HC flare a maximum allowable backpressure of 1.5 kg/cm2g at unit battery
limit shall be considered for sizing the main flare header. However, a maximum
allowable backpressure of 1.7 kg/cm2g shall be considered at PSV outlet of
respective units
f) For acid flare a maximum allowable backpressure of 0.7 kg/cm2g at unit battery
limit shall be considered for sizing the main flare header. However, a maximum
allowable backpressure of 0.9 kg/cm2g shall be considered at PSV outlet of sulphur
block.
g) Flare header shall be purged by all units maintaining a minimum Purge velocity of
0.1 fps in respective unit headers with fuel gas. In addition all dead ends of flare
headers shall be purged with fuel gas.
h) Maximum allowable radiation shall be limited as per requirements of API RP 521.
Average wind Velocity of 20 m/s shall be considered for calculation of radiation.
i) SMOKELESS CAPACITY: As there is no continuous release of hydrocarbon gases to
flare except fuel gas purging, the normal flare load is not much. Also there is no
extended start-up requirement for any process unit. Therefore, flare system shall be
designed for a smokeless capacity of 3% of peak flare loading.
j) An ultrasonic flow meter shall be provided for flare gas flow measurement
downstream of main KOD in hydrocarbon flare header.
k) Peak load is based on GSU reflux failure which contains 10% CO2.To assist flaring of
this high CO2 acid gas , a provision is kept to inject 6.5TPH of fuel gas along with acid
gas for easy burning of high CO2 gases.
PROJECT
On-shore Gas Terminal
Gujarat State Petroleum Corporation Ltd.
Deen Dayal Field Development
Gandhinagar