You are on page 1of 4
e2eors Types of Loads Considered for Piging Sess Anais Types of Loads Considered for Piping Stress Analysis Every Piping system is subjected to different loads during its design life which develops stresses in the system. Depending on the stress design basis the system is classified as stress critical or non- stress critical. All the stress critical system shall be stress analyzed using software system (eg.Caesar I) to keep the stresses within the allowable limits as per the code/standard. The types of loads to be considered inStress Analysis shall be as given in table: Types of Loads: a) Thermal Loads at Various Operating ‘@) Thermal Loads at Various Operating Conditions: Conditions b) Sustained Loads ¢) Seismic Loads d) Wind Loads ©) PSV Reaction Force #) Sug Force Analysis Temperature and Pressure to be used shall be as mentioned below. Analysis Temperature 9) Forces Induced by Surge Pressure Normally the Design temperature (Maximum/ Minimum values as per Line List) shall be used for thermal analysis, For those lines having Design temperature greater than 80 deg, C and if the difference between Operating and Design temperature is more than 25 deg. C, the maximum/minimum Operating temperatures, as obtained from Process Group, may be used in Stress Analysis in place of the Design temperature. In addition to the Maximum/Minimum Design/Operating temperatures, Piping shall also be analyzed for the Normal Operating temperature. Analysis Pressure Line Design Pressure specified in the Line List shall be considered as the analysis pressure. hupuhwvoiping-enginoering.conoasings-consdered-pping-stress-anais nt 1 aos Types of Loads Considered for Piging Sess Anais b) Sustained Loads Sustained loads to be considered are as given below: + Design pressure. ‘+ Weight of Pipe and associated components such as Flanges, Valves, Strainer, ‘+ Sight glass etc., mounted on the Piping System. ‘+ Weight of Fluid/contents in the piping, + Insulation and cladding weight. + Hydro test loads, if applicable for the line. + Snow load, if applicable, ¢) Seismic Loads For Projects where Seismic Design is to be carried out, equivalent Static Seismic Analysis method in Caesar II shall be used to evaluate the seismic stresses, displacements and loads on the piping system. the Seismic coefficient is not provide by the client, then the calculation of static seismic co-efficient in terms of 'g! based on Project site-specific data shall be calculated as per relevant codes (UBC/ASCE/SNIP/others as applicable). In that case, the Seismic factor calculation document shall be enclosed as an Attachment to the Project Stress Analysis Design basis document. The normal Operating Temperature shall be used when analyzing for Occasional loads. Seismic loads shall be considered as acting along the horizontal axes (both in +ve and in the ~e directions, that is, along North, South, East and West directions), but not acting simultaneously, d) Wind Loads Wind loads shall be considered for lines with outside diameter 14” NB (including insulation) & above and at Elevation 410 meters & above from ground level. The normal Operating Temperature shall be used when analyzing for Occasional loads. ‘Wind shape factor shall be considered as 0.7. Wind loads shall be considered as acting along the horizontal axes (both in the +ve and in the -¥e directions, that is, along North, South, East and West directions), but not acting simultaneously. Wind pressure for the different Elevations shall be specific to the Project as per the Project CivilStructural design basis. The same shall be considered for wind data input in piping analysis, e) PSV Reaction Force the Piping System being analyzed consists of PSV (pressure safely vale), the reaction force due to PSV operation shall be considered as applicable and a static equivalent method of stress analysis shall be performed considering the same. hupuhwvoiping-enginoering.conoasings-consdered-pping-stress-anais nt 28 e2eors Types of Loads Considered for Piging Sess Anais ‘A Dynamic Load Factor equal to 2.0 shall be applied on the valve reaction force value. However, in the case of valves of high reaction force values, the DLF value calculated as per appendix-lI of ASME B31.1 may be used, based on valve data if provided by Vendor. f) Slug Force For lines having slug flow regime, as identified by the Process group on P&Diline list, slug force shall be considered in the piping stress analysis. Slug force shall be calculated as below: Fslug = (p) (A) (V2) [2(1 - cos @)]1/2 DLF Where, Fslug = Force due to slug in Newton p= Density of the slug in Kg/m3, ‘A= Inside area of pipe cross section in m2, \V = Velocity of moving slug in misec. @ = inclusion angle at elbow or change of direction DLF = Dynamic Load Factor (DLF) equal to two shall be used, unless more accurate value is available, Foxtel flow Fosthogona Figt: Forces at a 90° bend (oF 90° change in direction or at intersection) Faxial = (p) (A) (V2) DLF Forthogonal = (p) (A) (V2) DLF hupuhwvoiping-enginoering.conoasings-consdered-pping-stress-anais nt 3

You might also like