Professional Documents
Culture Documents
AR550 Series Industrial Switching Router Quick Start Guide PDF
AR550 Series Industrial Switching Router Quick Start Guide PDF
Issue: 12(2017-10-11)
Part number: 31505671
The installation accessory package of AR550C-2C6GE does not include 3-pin connector and 4-pin connector.
NOTE
The installation accessory package of AR550C-4GE does not include 2-pin connector, 3-pin connector, and 7-pin
connector .
The installation accessory package of AR550C-2C6GE-2D does not include 4-pin connector and 7-pin connector.
Items and quantities in the installation accessory package vary depending on the product model.
Safety Guidelines
To ensure personal and equipment safety, observe all the safety precautions on the equipment and in this
document. and items do not cover all the safety precautions and are only supplementary to
WARNING CAUTION
Follow all the safety precautions and instructions provided by Huawei. The safety precautions outlined in this
document are only those that Huawei can predict. Huawei is not liable for any consequence that results from
violation of regulations pertaining to safe operations or safety codes pertaining to the design, production,
WARNING AR550 series industrial switching routers are class A products. In a domestic environment, these products
may cause radio interference in which case the user may be required to take the adequate measures.
The AR550 has more than one power input. Disconnect all power inputs to power off this device.
CAUTION During installation and maintenance, take ESD protection measures, for example, wear ESD gloves or an ESD wrist
strap.
During router transport and installation, prevent the router from colliding with objects like doors, walls, or shelves.
Do not place other objects on the router.
NOTE The installation, connection, and login methods of AR550 series industrial switching routers are similar. This
document uses the AR550-8FE-D-H and AR550E routers as an example. For more information, see the Hardware
Installation and Maintenance Guide.
Figures in this document are for reference only and may not show the actual appearance of the router.
1
Site Environment
Do not place this product in an environment with flammable or explosive gases, or smoke.
The installation site must be free from leaking or dripping water or heavy dew. If the relative humidity is high,
The installation site must be well ventilated, and the air vents of the router must not be blocked.
1 Place the router's real panel in front of the DIN rail and ensure that the DIN rail fits in between the fixture
near the top of the router and spring latch near the bottom.
NOTE Before the installation, ensure that the DIN rail has been secured in position.
The router is placed near the DIN rail for convenient movement.
2 Make the router incline forward with the bottom away from the DIN rail, and place the fixture at the rear of
the router on the top of the DIN rail.
3 Slowly push the router toward the DIN rail to make the spring latch at the rear of the router move down.
The spring latch then bounces back to fix the router on the DIN rail.
NOTE If the spring latch is too tight to move down, you can pull down the spring latch during the installation.
2
Scenario 2: Installing the Router in a Cabinet (Using a 550 Horizontal Rack-Mounting Kit)
CAUTION There must be a clearance larger than or equal to the router's width at the left and right of the router after the
installation. The clearance above the router must be at least two times the router's height and the clearance below
the router must be greater than or equal to the router's height.
1 Install two floating nuts on each front mounting rail of the cabinet. Leave four mounting holes between the
two floating nuts on the same mounting rail.
NOTE The length of six adjacent mounting holes may not be 2 U. Observe the scale ticks on the mounting rails when
installing floating nuts.
You can use a flat-head screwdriver to install floating nuts.
1 2
×4
2U
2 Attach the brackets of the 550 horizontal rack-mounting kit on the front mounting rails of the cabinet and
insert M6 screws in the mounting holes. Use a Phillips screwdriver to tighten the lower M6 screws and then
the upper ones to fix the rack-mounting kit.
3 Place the rear panel of the router in front of the DIN rail on the rack-mounting kit and ensure that the DIN
rail fits in between the fixture near the top of the router and the spring latch near the bottom.
4 Make the router incline forward with the bottom away from the DIN rail, and place the fixture at the rear of
the router on the top of the DIN rail.
5 Slowly push the router toward the DIN rail to make the spring latch at the rear of the router move down.
The spring latch then bounces back to fix the router on the DIN rail.
NOTE
If the spring latch is too tight to move down, you can use a flat-head screwdriver to hold down
the spring latch during the installation.
3
Scenario 3: Using a Vertical Rack-Mounting Bracket to Install an AR550E Router into an
F01S200 Cabinet
1 On each front mounting rail, install two floating nuts in the fifth and eighth mounting holes
counted from the left.
NOTE
You can use a flat-head screwdriver to install floating nuts.
1 3
RESET
SYS
7
15
12V-48V; 6A
DC1
- +
USB
6
14
SYNC
DC2
- +
5
13
CONSOLE
4
12
GE/PoE+
PoE1
17
- +
GE
48V; 5A
2.5GE
11
16 3
PoE2
- +
10
2
1
- +
DI
10GE
9
1
0
8
0
PoE1
PoE2
DC1
DC2
a c
a Use a Phillips screwdriver to remove the seven M4 screws at the back of the router.
Align the seven M4 mounting holes on the vertical rack-mounting bracket with those at the back of
b
the router.
3 Move the router and vertical rack-mounting bracket into the cabinet. Use the Phillips screwdriver to
tighten the M6 screws on a diagonal line on the vertical rack-mounting bracket, and then tighten the
M6 screws on the other diagonal line.
4
Connecting the Router
NOTE
For details about pin assignments and cable connections, see the Hardware Description.
1A 2A
1B 2B
5
2
Connect to an
electrical interface to Boolean output External digital
1 Ethernet cable Switch or PC receive and send 5
cable input devices —
data services.
5
Powering On the Router
Indicator Description
NOTE For more information about indicators, see the Hardware Description.
NOTE If your PC's operating system provides terminal simulation software (like HyperTerminal in Windows 2000), you do not
need to install additional terminal simulation software. If the PC runs on an operating system without terminal
simulation software (like Windows 7), install third-party terminal simulation software on the PC by referring to user
manual or online help.
A PC may have more than one serial port. Select the port connected to the console port. Generally, COM1 is used. If
you modify the serial port communication parameters on the router, modify the communication parameters on the PC
to ensure that they use the same communication parameters, and then set up the connection again.
2 Start the terminal simulation software, create a connection, specify the connected port, and set
communication parameters as follows:
Bits per second (B): 9600
Data bits (D): 8
Parity (P): None
Stop bits (S): 1
Flow control (F): None
3 Press Enter until a message is displayed asking you to enter the username and password. (The following
information is for reference only.)
NOTE The default user name is admin and the default password is Admin@huawei.
6
Login authentication
Username:admin
Password:
<Huawei>
Info: The entered password is the same as the default. You are advised to change
it to ensure security.
CAUTION If you forget the login password, restore the password according to the Troubleshooting.
After successful login, you can configure the router on the command line interface. For more information,
see the CLI-based Configuration.
To configure the router using the web system, perform the following steps (V200R005C70 and later versions
Support).
10 Configure an IP address for the PC. The IP address must be in the range of 192.168.1.2 to 192.168.1.254.
11 Start the Internet Explorer (8.0 or later), Google Chrome (23 or later), or Mozilla Firefox (12 or later),
enter https://192.168.1.1 in the address box, and press Enter to display the login page.
12 Enter the user name admin and password Admin@huawei (case sensitive).
7
Now, you can configure the router on the web page. For more information, see the Web-based
Configuration of the product.
Declaration of Conformity
Hereby, Huawei Technologies Co., Ltd. declares that the radio equipment type is in compliance
with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address:
www.huawei.com/en/product-certification.