Ensayo 5 (contracorriente)

SENSOR TEMPERATURADensidad Viscosidad Velocidad Reynolds K Cp


ST-16 45 990.22 0.000596 0.6374 4.18
ST-1 36.1 993.69 0.000704 0.14091844 3182.48281 0.622 4178
ST-2 33.7 994.53 0.00074 0.14091844 3030.21871 0.6171 4178
ST-3 35.6 993.87 0.000711 0.14091844 3151.72116 0.621 4178
ST-4 34.6 994.22 0.000726 0.14091844 3087.68993 0.619 4178
ST-5 34.1 994.4 0.000734 0.14091844 3054.58956 0.6179 4178
ST-6 33.7 994.53 0.00074 0.12057193 3168.85617 0.6171 4178
ST-7 32.3 994.99 0.00076 0.12057193 3086.89234 0.6142 4178
ST-8 33.1 994.73 0.000749 0.12057193 3131.40872 0.6159 4178
ST-9 31.9 995.12 0.000766 0.12057193 3063.11318 0.6134 4178
ST-10 31.4 995.28 0.000774 0.12057193 3031.94051 0.6124 4178
Caudal (M/S) ÁREA
SC-1 2.833333E-05 0.00020106
SC-2 3.333333E-05 0.00027646
1s

Rugosidad
Reynolds Densidad
Re=(p*v*D)/M
Pr Rugosidad Cu f NuD hi flujo másico m*Cp
0.0015
4.72879743 0.0015 0.04354411 20.7842785 807.988826 0.02815455 117.62971
5.0100794 0.0015 0.04424652 19.9427159 769.165624 0.02817835 117.729146
4.78350725 0.0015 0.04368193 20.6182003 800.243898 0.02815965 117.651018
4.90020679 0.0015 0.04397533 20.2653692 784.016472 0.02816957 117.69245
4.96302314 0.0015 0.04413059 20.0804547 775.482062 0.02817467 117.713757
5.0100794 0.0015 0.04359464 21.0913283 0.033151 138.504878
5.16978183 0.0015 0.0439689 20.6356943 0.03316633 138.568941
5.080893 0.0015 0.04376381 20.8833173 0.03315767 138.532731
5.21739159 0.0015 0.04408027 20.5003971 0.03317067 138.587045
5.28048988 0.0015 0.04422823 20.3205854 0.033176 138.609328

D
equivalente
agua fría
0.01955556
0.01955556
0.01955556
0.01955556
0.01955556
Transferencias de calor

SENSOR TEMPERATURA °C flujo másico Cp


ST-16 45 4180
ST-1 36.1 0.02815455 4178
ST-2 33.7 0.02817835 4178
ST-3 35.6 0.02815965 4178
ST-4 34.6 0.0281695667 4178
ST-5 34.1 0.0281746667 4178
ST-6 33.7 0.033151 4178
ST-7 32.3 0.0331663333 4178
ST-8 33.1 0.0331576667 4178
ST-9 31.9 0.0331706667 4178
ST-10 31.4 0.033176 4178

U
520.2232796468

NTU
1.0003573385
Transferencias de calor, flujo caliente Qh
Tramo 1, 2m -58.8201819
Tramo 2, 1m -117.6717336
Tramo 3, 1m -58.85155172
Total -235.3434672

Pérdidas de Energía
83.3387749

CR
0.8486421907
Transferencia de calor, flujo frío Qc
Tramo 1, 2m 83.1112828
Tramo 2, 1m 166.271866
Tramo 3, 1m 69.29909333
Total 318.6822421

Eficiencia
0.4255319149

Eficiencia contracorriente
0.51924