CPP BUNKER LEVEL

Steam calculation=mass of fuel *ncv *.785


TON (802-190)=612

BOILER EFFICENCY=78.5% (TOTAL ST.*612+CBD*130)


COAL FUEL*NCV
NCV=3550 KCAL/KG
OIL NCV =9650 KCAL/KG
Coal analysis Mts. Qty. of coal in Bunkers in Metric Ton.
KTS RAKE 39 Empty -----------------(DENSITY)-------------------------
Ash=45.62% 1.0 1.2 1.4 1.8 2.0
F/c =35.42% 8 2.27 2.224 3.178 4.09 4.54
Ncv=3637 c 7 6.06 7.272 8.480 10.91 12.12
Gcv=3812 cal 6 15.15 18.18 21.21 27.27 30.30
5 30.30 3.36 42.42 54.54 60.60
Vol =18.48% 4 53.03 63.64 74.24 95.45 106.06
M0i=0.48 3 83.33 100.00 116.66 150.0 166.66
2 121.21 145.5 169.69 218.18 242.42
1 166.67 200.0 233.34 300.0 333.34
0 242.42 290.90 339.39 436.36 484.84