2 3 4 5 6 u 7 8 9 10 12

ITEM NO. 25-SAU-301


DESCRIPTION FISCAL METERING PACKAGE r 25
Ql
\ 25
Q
\ / 25
FI
/ 25r \ f 25
p
\ / 25
-1
\ f 25
Tl
\ / 25 \
T

A DESIGN (P/T) 1400 PSIG / 150 "F kM k y\ |yoo38/| [yoo39/| |yoo38/| [yoo39/| |yoo38/1 I/0039/ SSWJ METER CONTROL PANEL A
OPERATING (P/T)
SIZE
1068 PSIG / 103 "F
2 x 10” (NOTE 15)
W~l>
LU
w
o
CAPACITY
DUTY
NOR
MAX
20 MMSCFD (NOTE 4)
70 MMSCFD
210 MMSCFD
-o—o—o—o—o-
-o—o—o—o—o-
-o—o—o—o-
—o—o—o—o—o- —J
o
0 —o-1
9

-o-
|o

f 25\ / 25 \ / 25 \ / 25c \ / 25 \ / 25 \/ 25 25 25
:: zi: zio z zi: ZIC ZIC ZIC ZIO ZIC
0
0 VQ042/ \0042/ /004l/ y004l/ \0038/ '\0038/ \ 004ÿ|Vÿ045/|Vÿ047/|\0047/

FISCAL METERING PACKAGE BY METERING VENDOR


o 0

_ J_
TJTTJTTTI - -i- j _ VI ill
4-L-l-l- J-L.
im T T

_ __ _ _
__
TO PERTAGAS
(NOTE 13)
B PERTAGAS METER CONTROL PANEL J B
TO DCR i
(NOTE 13) i
L-‘

—i
1 _ I

Tl (N0_TE_12_)
L

i
1

r '
I
J
i
r i 1
“i
r i 1 (NOTE 5)
I I
ri /"25N| STREAM "A” f 25 \ Eo—o —o EDP ESD
SET @1100 psig

ANALOG JB DIGITAL JB
III I Iftttttt n ] FLOWRATE
Voony L
o
r-'
V0011/--1
in
c

0
JL

/
:0Y

PI \
AUTO SELECT
/'25'Nl H \Q03j/
rrrrrf
0
U— -s
725 \ =c SET @ 1060 PSIG CLOSE
i
Y°QI/I L (NOTE 10)
c L I I
Y yooii/ ypoii/ c
L
1
J
-
SET @70 MMSCFD
(NOTE 4)
* 71 ZIC s
25
XY
0003,
25
PT
25
P
1-
/25N| STREAM ”B” 25
ioo; \Q00 0036, 0037,
_ El FLOWRATE

___
"
Yoonj/I L PT i
- J 0011 3/4”-BA-CA- 3/4”-BA-CA-
i:C 05
IAS - 3-2-2837 IAS 3-2-2834
/- z 25 25
2”-BA-CA 2”-BA-CA
2 icL ll r 25\
IS
25
BY PIPING
f 25
HS
\ IAS fn -3-2-2830
25
F V
BY INSTR zso
0003
zsc
0003 BY INSTR -3-2-2890
PERTAGAS

00
XY ESDV

m
25 25 25 XY 0011
1
BY PIPING SALES GAS
20 -BA-CA 20 -BA-CA 4/ V0038/ 0038, F PT FT BY INSTR V0043/ 0043
I # \ IAS | 3/4” 0003, BY PIPING 20”-BA-CA 2 (NOTE 16) PIPELINE
FROM METERING PACKAGE ,00138/ \ 0038
-3-2-2823/ 25 fi

--
0038, (NOTE 6) rc (NOTE 6) -3-2-2833
PID-PL-25-0005\ D
u.
-3-2-2822
IIXCII
|0”x20" L0
|
_[ _
\m) sT
IC ,
LxJ

T
LU
.
T
LxJ
LX:
T
25
25
S 25
ZSC
0038
X-
TT
0038,
25 25
s
25
ZSO
a
20”-BA-C/
T
20"x16"
16” 20"x16"
20”-GP-CA1-25-0192
_ (NOTE 6) TS0 1
IMh
20”-CK-CA
I IIMI
-L(N0TE 6)\
T
30”-GP-CA1-25-0196 (NOTE 6)
JNOTE 6,11) Ss?- Z: ZSC
ZSO TE Tl 25 0041 -3-2-2825 I \ 20”-BA-CA W 2”-BA-CA FC 2 -3-4-2832 17) 2-3-2-2834
2”- BA-CA
2”-BA-CA <
Q_

ybJ
00 Q_CO

yUJ
Q_

yUJ
00
5°-
i . I1 25
0044
0038 g yJ(N0TE 2) 0038
<
0138
' ( XV
0043,
25
ZSC 2 "-BA-CA
-3-2-2826 44 -3-2-2886
2”- BA-CA 2”- BA-CA (NOTE 7)
zso 10”- BA-CA -3-2-2827
D
-3-2-2824 iH
T
it
IT
it
Y T
0044, <-3-2-2837
0038
PROFILER
(NOTE 1)
(NOTE 2)
0041 -3-2-2889 -3-2-2884
D
STREAM -A SP INSULATING
(NOTE 8, 11) -HH-EHI- (NOTE 6) 0298 GASKET
25 10” 0” 10”- BA-CA
HV FC 1°”-CA ,n FC
ff r HS 25
j -3-2-2840 20"-BA-CA
2”-FH-CA1 -25-0201 0044, E 2”-BA-CA
10D 10D
4 USM .3D, 25 \ zsc -3-2-2828 20”-GP-CA1-25-0203 CPGL SCOPE OTHER (PERTAGAS SCOPE)
2”-BA-CA -3-2-2849 1 4 PATH USM I
V0047/
0043
2”- BA-CA
SP GAS PLANT (B31.3)
2"-BA-CA 5
-3-2-2850 -3-2-2854 | 1
0300 25
T 2”-GL-CA -3-2-2888 3 ZSO
#-3-1-2851 (NOTE 3) 0043, BATERY LIMIT
C 25 25 25
1

25
1
IAS
10”-GP-CA1-25-0197
25
HV AT FENCE
2’’-GL-CA 2”- BA-CA _
|M| 1 "-BA-CA 25 0041
TO FLARE HEADER -3-1-2852 -3-2-2853 -3-2-2831
HV ZSO ZSC XV
s XY
2”-FH-CA1-25-0194 i r \0040 0040, 0040, 0047
-MM- 0047
XCKABLE 10”-BA-CA
2”-FH-CA1 -25-0194 <+
(NOTE 2) -3-2-2882
Valve Open
-Zi 10”- BA-CA I 25
FC 25
E CO
CD
O)
-3-2-2881 J ZSO zsc Valve Close E
0047 0047,
CT)
o 2”- BA-CA
5 -3-2-2883
7 .A
CN
LO
CN

_
< <
o
o
•CM Y TITÿIAS & CNJ
05
HS =o / 25N IAS Y
o V0045/ -s 25
CN
25 25 25 \0046/ XY Yzz
25
L
in XY Dl PT FT 0046,
! 25 Y
25 25 S
0045 0139/Y0039, 0039, TT
0039
L -- S
o

ZSC ZSC S 25 C -i
0039/ V 0045 . 25
25 25 1 ZSO 25
ZSC =o
1 TE Tl 0042,
25 25 O
zso DXJ— 0039, 0139, BY INSTR 25 0042,
i

0045,
zso XV
(NOTE 1) g BY PIPING r~ XV
(NOTE 2)
7 0039, 0045, 0046,
9. RETRACTABLE SAMPLE POINT PROBE : F
If „ STREAM-B PROFILER /z- T'CN T CN
3
10”-BA-CA 010” (NOTE 3) 10” 10”-BA-CA

TO SAMPLE 2”-BA-CA w
-3-2-2844
i FC

2”-BA-CA
10D 10D
1°”-CA
USM
4 PATH USM
.3D,
10”-GP-CA1-25-0198
25
zso
25
zsc
FC

2”-BA-CA
J -3-2-2846
25
-3-2-2857 25
CONDITIONING -3-2-2856 0046/ \0046, -3-1-2861 HV
INST SYSTEM I HV
2”-GL-CA w 0039, 2"-BA-CA SP 0042,
0301
PIPING 2”FL -3-1-2858 m -3-2-2887
’’-BA-CA (NOTE 3) 25-SAU-301 L
— IMI 1-3-2-2829 _
2”-FH-CA1 -25-0202
\ 2”-FH-CA1-25-0200 FISCAL METERING PACKAGE
(HOLD 1)
L J

10. OPERATING PRESSURE RANGE :


•MIN = 900 PSIG : LOW PRESSURE ALARM : 880 PSIG 2"-GL-CA 2”-BA-CA
•MAX = 1060 PSIG: HIGH PRESSURE ALARM: 1080 PSIG -3-1-2859 -3-2-2860
G 11. 20” 600# BLIND FLANGE SHOULD BE INSTALLED DURING SHUTDOWN G
PERIOD BEFORE CONNECTED TO PERTAGAS USM SYSTEM
12. DIAGNOSTIC SIGNAL
13. CABLE OPTIC
17. GLOBE VALVE AND TEMPORARY LINE WILL BE INSTALLED BETWEEN 2”-BA-CA-3-2-2884 AND 2”-BA-CA-3-2-2834 DURING START-UP TO PRESSURE TRUNKLINE HOLD FOR PERTAGAS SCOPE :
18. DENOTES GRISSIK DURI USM PROJECT SCOPE
14. GAS CHRAMFORGRAPH SPLIT SIGNAL (( ))
1. MINIMUM FLOW CAN BE ACHIEVED @ 908 PSIG BY
15. H2S & H20 ANALYZER SIGNAL 19. DENOTES GRISSIK PERTAGAS USM AND PIPELINE
16. HIGH POINT VENT / MAINTAINING ITS ACCURACY
J TIE-IN PROJECT SCOPE

NOTES : THIS DRAWING HAS BEEN DERIVED FROM PREVIOUS DWG. NO.:
1. FOR BOROSCOPE INSPECTION (45 DEGREE) 2E 24.08.17 RE-AFC RE-APPROVED FOR CONSTRUCTION RR AN I ANI HR AK PH.TW DW BR DRAWING NO.: REV. ID-N-CG-PP0-PID-PL-25-001 1 REV.2D
2. MANUAL ACTUATED VALVE WITH HANDWHELL 2D 06.07.17 AFC APPROVED FOR CONSTRUCTION RR ANI ANI EAN YP PH DW BR GRISSIK-PERTAGAS ULTRASONIC CUSTODY METERING AND

H
3.
4.
FLOW PROFILER
OPERATING FLOW RANGE :

•NOR.
VENDOR TO ADVICE MIN. FLOW
TO MMSCFD
@ 908 PSIG (HOLD 1)
2C
2B
2A
05.06.17 RE-IFA RE-ISSUED FOR APPROVAL
17.03.17
07.03.17
IFA
IFC
ISSUED FOR APPROVAL
ISSUED FOR COMMENT
RR
RR
AS
ANI
ANI
ANI
ANI
ANI
ANI
EAN
EAN
EAN
YP
YP
YP
PH DW
PH DW
DW
BR
BR
BR
ConocoPhillips PROJECT TITLE:

DISCIPLINE /
SUB-DISCIPLINE : PROCESS / PROCESS GENERAL
PIPELINE TIE-IN PROJECT

H
5.
•MAX 260 MMSCFD
DURING NORMAL OPERATION, 25-FV-001 1 IS FLOW CONTROLLED IF PIPELINE PRESSURE INCREASE IN CREASE AVOCE
2 14.02.17 IFU RE ISSUED FOR USE IVN GW GW YS TW DW BR
ConocoPhillips (Grissik) Ltd.
DOCUMENT TYPE :
PIPING AND INSTRUMENTATION DIAGRAM
1 25.07.16 IFU ISSUED FOR USE IVN GW GW YS TW DW SO
1060 PSIG, 25 -FV- 0011 WILL BE PRESSURE CONTROLLED CPGL GROUP OWNER : AREA : TITLE :
6. BALL VALVE FULL BORE, SINGLE BODY DOUBLE ISOLATION AND BLEED (DIB-1 PCV ADI 6D)
OC 30.06.16 IFC ISSUED FOR COMMENT (FEL-3) IVN GW GW OD TW DLH SO UO | ASSET ENGINEERING ONSHORE SUMATERA CG I GRISSIK SYSTEM 25-GAS EXPORT AND METERING
7. LOW POINT DRAIN OB 24.02.16 IFA ISSUED FOR APPROVAL HTS MDM MDM HH SO LOCATION : SYSTEM : PERTAGAS SALES GAS METER AT GRISSIK
PL | CENTRAL GAS PLANT 25 | GAS EXPORT AND METERING
8. DATA OF H20, H2S AND GC WILL BE TAKEN FROM EXISTING SSWJ METERING SYSTEM (DWG. NO. NO. REFERENCE DWG TITLE REFERENCE DWG NO. DATE STATUS LEAD Pr.ENG. P.E L.P.E U.O SCALE: PROJECT NO. DWG NO. : REV.
REVISION BY CHK ENG.
ID-N-CG-PP0-PID-PL-25-0005) SAMPLING PROBE AT PERTAGAS SKID SHALL BE PROVIDED FOR FUTURE OPERATION NUMBER ENG. /E.M COMPANY A1 CAD DRAWING DO NOT ALTER MANUALLY
Cod File :
NTS N-CG-066 ID— N— CG— PPO— PID— PL— 25— 001 1 2E