Basic Setting

Normal (Potentiometer & Flap Adaptation)

Prerequisites:

Potentiometer / Flap replyed

OR Climatronic Control Module (J255) replaced

OR Climatronic Control Module (J255) recoded

[Select]

[08 - Heating/Air Conditioning]

[Basic Settings - 04]

Group 001

[Go!]

Activate the Basic Setting.

[ON/OFF/Next]

The basic setting takes approximately 25 seconds.

[Done, Go Back]

[Close Controller, Go Back - 06]

Service Position

Notes:

Has to be performed before ANY Actuators/Motors are being removed.


While in Service Position the Display reads SF (German for "Servicefall").

Make sure to have the Ignition OFF while working on the Actuators/Motors.

Once all work has been done, switch ON the Ignition and perform the normal Basic Setting
(Potentiometer & Flap Adaptation).

[Select]

[08 - Heating/Air Conditioning]

[Basic Settings - 04]

Group 002

[Go!]

Activate the Basic Setting.

[ON/OFF/Next]

The Display should read SFnow.

[Done, Go Back]

[Close Controller, Go Back - 06]