1 2 3 4 5 6

STROKE OF THE FLOATER ASSLY.SHOULD BE 15mm


NOTE.- SET THE STROKE OF THE FLOATER BEFORE TESTING

TESTING INSTRUCTION
SB-021 APPLY WATER PRESSURE OF 5 BAR FOR 5 MINUTES
& IT MUST NOT DAMAGE THE SWIMMER ASSLY
SB-003A
SB-020 SB-021
SB-010
A SB-002 A

SB-013 SB-014

SB-005 SB-004
SB-006
SB-003A VALVE BODY GLASS FILLED 1 A/214C
NYLON
SB-020 NIPPLE BRASS 1 A/214M
SB-021 ELBOW 1-1/4"BSP(F) IS:1570,C20 1

B SB-005 PIN/KNOB ASSLY S.S202 1 A/214E B

SB-006 HEX NUT M8x1.25 S.S202 1 ---


SB-010 RUBBER VALVE Φ40xΦ11x8.5 SBR 2 A/214H
SB-015 Sq.GASKET SBR 1 A/214L
(BOTTOM PLATE)
stud S.S202 8
SB-007 FLOATER ASSLY S.S202 1 A/214F
SB-004 INSERT ---- S.S202 1 A/214D
All rights strictly reserved. Reproduction or issue to third parties in any form

SB-014 GASKET(BODY) SBR 1 A/214K


whatever is not permitted without written authority from the proprietor.
Property of Impulse Holding B.V. Copyright Impulse Pumps B.V.

SB-002 TOP PLATE-II M.S. PLATE 1 A/214B


C SB-007 C
SB-013 Sq.GASKET(TOP SBR 1 A/214J
PLATE)
SB-001 BOX ASSLY. ---- M.S 1 A/214A
PART NO PART NAME DESCRIPTION MATERIAL QTY. DETAIL
SB-015 DRG.NO.
Revision information format scale projection

Rev Date Drn Appr Info A 3 1:5


- - Drawn : AK Title : SWIMMER BOX VP-50
Date : 29-08-2014 Dwg No. : 2014-10344 Rev. -
Weight : Kg Material : Material <not specified>

NOTE:- SUITABLE FOR VP50 ONLY


State : Under Editing Treatm. : -
UNSPECIFIED GEOMETRICAL, LINEAR AND ANGULAR
D TOLERANCE SHALL CONFERM TO ISO 2768-MK
(UNLESS OTHERWISE STATED) Impulse Pumps B.V. - Arendsenweg 9 - 7021 PC Zelhem - The Netherlands D