FORCE
SENSORS
FOR
DESIGN
IN RECENT YEARS, factors such as consumer demand and
a tough economy have pushed OEMs to produce sleeker,
smaller, and less costly products than in the past. This forces
designers to spec or engineer parts for increasingly tight space
requirements. In this difficult situation, even small components
such as force sensors can play a surprisingly big role in the
development of successful solutions. A patented, thin-film,
flexible but accurate force sensor was developed specifically
to target industry needs for a low-cost, unobtrusive, force
or pressure-measurement solution. The unique technology
eliminates many of the challenges plaguing engineers in the
design of streamlined products.

TekScanFinal.indd 1 4/6/09 3:40:43 PM


Tekscan
Selecting
a low-power
force sensor
for seamless
integration
and sleeker
designs

M
OST ENGINEERS ARE FAMILIAR sor has become commercially available. The
with the numerous types of force generic term for these devices is tactile sensor.
sensors. These devices abound in The term comes from their frequent use as a
robotics, industrial equipment, au- means of sensing a nuanced or delicate touch,
tomobile safety systems, and many other areas. as with a robotic hand from a humanoid robot.
The most well-known transducers for mea- But tactile sensors have applications extending
suring force are load cells. They can use a far beyond anthropomorphic robots. They typi-
variety of technologies to sense loads. Strain cally are built on flexible circuit material so they
gages, piezoelectric elements, and variable ca- can be thin, light, and flexible (within reason).
pacitance are among the methods in wide use. This opens up potential applications as, for
Load cells, however, have some drawbacks, example, sitting under a bolt head to sense the
particularly in applications where weight and load as a technician wrenches the nut tighter,
size are both at a premium. Load cells can be or measuring the force between two rollers
bulky. In situations where the application of directly from within the nip.
interest involves relatively lightweight elements, One such tactile sensor in particular
the load cell may weigh more than the compo- targets uses that can benefit from an unob-
nent being tested. And some types of load cells trusive force measurement with a transducer
can also be subject to ringing in certain ap- that is also economical. Called a FlexiForce®
plications because their internal elements have sensor, it consists of special, proprietary
spring-like qualities. piezoresistive material sandwiched between
In recent years, a different type of force sen- two pieces of flexible polyester with printed-

TekScanFinal.indd 2 4/6/09 3:40:46 PM


Produced by Machine Design Custom Media

silver conductors on each inner half. The con- shape off-the-shelf for testing/proof of concept
ductive traces form electrical connections to and are available in several lengths. But these
external circuits. The resulting sensor is paper sensors can also be fabricated in custom form
thin, only about 8 mils thick. factors with relative ease for OEM applications.
Similarly, the range of force these sensors
FOCUSED ON handle can be customized as well. They can
VERSATILITY also be quite sensitive to applied force. A Flexi-
FlexiForce sensors, manufactured by Tekscan, Force sensor can register a light touch of only
Inc., are basically resistors that vary linearly 5 gm, though recommendations are to load at
in terms of conductance vs. force under an least 80% of the device’s sensing area with 40
applied load. With no force applied, their re- gm or more for best results. It is also possible
sistance is on the order of megaohms; it is es- to adjust the sensor’s dynamic range by tweak-
sentially an open circuit. As applied force rises, ing its external drive circuit. These adjustments
output resistance drops, eventually reaching are as easy as a turn on a potentiometer.
about 10k Ω or lower, depending on the appli- Also available are “matrix” sensors, which
cation. The output, expressed in conductance come in a variety of standard shapes and sizes.
vs. force, is quite linear (linearity error < ± 3%). These sensors are often referred to as “sensor
External circuitry to convert the output into a mats.” The mats can be built with sensing loca-
linear analog voltage can be relatively simple. tions as small as 0.0009 sq-in. or covering areas
FlexiForce sensors come in one standard up to 256 sq-in. These packages are considered

100-lb Sensor
1200 0.020

0.018
1000
0.016
Force
orce
e
0.014
Resistance (K-Ohms)

800
0.012
Conductance

Co
C
Conductance:
on
o nd 1/R
600 0.010

0.004
400
0.006

0.004
200
Resistance
Re
esiista
esi sta
anc
ce 0.002

0 0.000
0 10 20 30 40 50 60 70 80 90 100 110 120
Force (lbs)

FlexiForce sensors are basically resistors that vary linearly in terms of conductance vs.
force under an applied load.

TekScanFinal.indd 3 4/6/09 3:40:46 PM


Tekscan
pressure-mapping systems and are designed
to be used with Tekscan’s patented electronics COMPARING
and software to display areas of high and low CAPABILITIES
pressure across the surface of the sensor. They It is useful to compare FlexiForce sensors with
typically find use in R&D, test & measurement, other types of tactile sensor technologies. One
and quality assurance applications. design uses a piezoresistive material, similar to
This sort of versatility lets tactile sensors that of FlexiForce sensors, sandwiched between
play a role in a number of imaginative uses. flexible plastic sheets, but puts both conductive
The first generation of thin-film force sensors areas on the same substrate. A point to note
emerged in the 1980s. Developed by Tekscan about this design is that the output depends on
for the dental industry, they let clinicians mea- the sensor area over which the force is distrib-
sure the force and pressure distribution of a uted. A force acting on a large percentage of
patient’s bite with respect to time. This was an sensor area will produce a lower reading than the
advancement over a check with mere carbon same amount of force concentrated on a smaller
paper, which could only gauge peak pressure area. In this regard, such sensors behave as pres-
with no time reference. sure sensors rather than as force sensors.
Since the 1980s, the technology has been Another type of tactile sensor uses capaci-
further refined, and applications have emerged tance as the sensing mechanism. The typical
in such areas as conformal ergonomics, large makeup is that of overlapping row and column
metal-stamping machines, small electronic electrodes separated by an elastic dielectric
connections, and even soft rubber door seals. material. Compressing the dielectric between
Often, shoe manufacturers use FlexiForce sen- a particular intersection of row and column
sors to gauge the amount of force exerted by plates reduces the plate spacing and provides a
heels and toes to design a more comfortable response proportional to displacement.
shoe insole. One difficulty with capacitive tactile sensors
FlexiForce sensors are 100% factory-tested. is that they generally must be driven with a high-
Thus, they tend to be specified in applications frequency ac signal. This is because the dis-
that can’t tolerate failures. And, they are built placement change with applied force is relatively
in the United States, an advantage for custom small, and so is the change in capacitance.
sensor designs that incorporate a significant The electronics needed to convert capacitance
amount of intellectual property. change to force can be somewhat complicated.
In contrast, FlexiForce sensors are driven with
dc. They can be used with Tekscan’s Economi-
cal Load and Force (ELF) system to sample and
record data at rates of up to 5.7 kHz.
Simple drive electronics plus a thin profile
make FlexiForce sensors candidates for several
areas of use. The standard version of the sen-
sor has an active sensing diameter of 0.375 in.
In many cases, designers will prototype with
a standard sensor to prove a concept, then
Tekscan also offers a variety of matrix sensors, devise a custom version. Custom sensors can
which are used with patented software and have nearly any shape, even with irregular fea-
electronics for real-time pressure mapping over tures. Sensors can also be attached to stiffer
a given area. continued on page 6

TekScanFinal.indd 4 4/6/09 3:40:51 PM


Produced by Machine Design Custom Media

Standard and Custom Single-Point Force and Load Sensors


MODEL A201 FLEXIFORCE STANDARD, off-the-shelf sensors come four in a box. For customized
versions, Tekscan accepts orders ranging from 10 items to millions, depending on factors that
include sensor size and shape.

Physical Properties FlexiForce Standard Model A201


Thickness 0.008 in. (0.208 mm)
Length 7.75 in (197 mm) Optional
trimmed lengths: 6 in.
(152 mm), 4 in. (102 mm),
or 2 in. (51 mm)
Width 0.55 in. (14 mm)
Sensing Area 0.375 in. (9.53 mm) diameter Note the extreme
flexibility of the
Connector 3-pin Male Square Pin A201 FlexiForce
(center pin is inactive) standard sensor.
Substrate Polyester (ex: Mylar)

Standard Force Ranges


0 - 1 lb (4.4 N)
0 - 25 lbs (111 N)
0 - 100 lbs (445 N)
To measure up to 1,000 lbs, apply a lower drive
voltage and reduce the resistance of the feed-
back resistor (see circuit on page 7).
Custom versions of
Typical Performance FlexiForce sensors can
include sensors with
Linearity (Error) < ±3% more than one sensing
Repeatability < ± 2.5% of Full Scale element.

Hysteresis < 4.5% of Full Scale


Drift < 5% per Logarithmic Time Scale
Response Time < 5μsec
Operating 15ºF - 140ºF (-9ºC - 60ºC)
Temperature

New HT201 High-Temperature Force & Load Sensors: 15°F to 400°F (-9°C to 204°C)

TekScanFinal.indd 5 4/6/09 3:40:51 PM


Tekscan
continued from page 4 side of these ranges, a simple op-amp circuit
substrates such as hard plastic or metal if the can be constructed (see circuit on page 7). By
application environment demands it. adjusting the feedback resistor of the op-amp
Standard sensors are offered in the range circuit, or adjusting the drive voltage to the
of 0 to 1, 0 to 25, and 0 to 100 lbs. Overloads sensor, the force range can be fine-tuned up
up to 10,000 psi (plastic limit) won’t harm the to 10 times in either direction for keying in on
sensors. For measuring forces between or out- specific force ranges.

From infusion pumps to palpation proficiency


MORE RECENT MARKETS are functioning properly. more chance of malignancy.
taking off for thin-film sensors In another case, a National Over time, the group devel-
include the medical device Cancer Institute-sponsored oped MammaCare®, now rec-
industry. Novel devices mea- project in the late 1970s ognized as the medical and
sure forces exerted by tools began to use technology to scientific standard for clinical
during surgery for a more standardize breast exami- breast examination efficiency.
sensitive tactile response nation. The problem: Most Over the years, the group
and accurate simulations; breast lesions are palpable developed many design itera-
certify axial stabilization of and discovered by hand, not tions to come up with what
tendons and evenness of tis- X-ray, which works on bone today is called the Palpation
sues in joints during surgery and not on soft tissue. At the Proficiency and Assessment
to facilitate proper recovery; time, it was routine for tumors Device (PAD), which compris-
and obtain feedback from the size of golf balls to go un-es tactually accurate breast
forces exerted on infusion and noticed, not a good situation models instrumented with
syringe pumps to ensure they when the larger the tumor, the custom FlexiForce sensors.
The sensors locate
and relay over 1,000
levels of examination
pressure within each
square centimeter by
way of a digital signal
processor. The device
lets MammaCare
confidently certify
clinicians who have
demonstrated exami-
nation skill. The com-
plete solution also
included electronics,
The MammaCare breast model, containing small simulated tumors, hardware, firmware,
sits on the surface of a pad containing an array of FlexiForce sensors. and Windows drivers
The sensors provide force feedback data used to measure the perfor- designed and pro-
mance quality of a clinician’s breast examination skills. These data duced by SSI Wire-
are used to certify breast examination proficiency. less.

TekScanFinal.indd 6 4/6/09 3:40:53 PM


Produced by Machine Design Custom Media

pinpointing the problem and adjusting the


equipment accordingly. The monitoring device
eliminates a lot of line downtime because ad-
justments just take a few minutes.”
Bottling lines can run at speeds of 1,200
bottles a minute. At these speeds, there are a
lot of bottle collisions associated with corralling
and other handling operations. Only a durable
Typical drive circuit for sensor. sensor can withstand this sort of treatment,
says MacDonald. Some of the company’s cus-
tomers have been using the same monitoring
SIZING UP device for 2 ½ to 3 years now.
APPLICATIONS Durability also tops the list for SSI Wire-
Light weight and size aren’t the only reasons for less, a U.S. engineering firm and business
employing FlexiForce sensors. Durability was a unit of SSI Embedded Systems. According to
key driver for Sensor Wireless, a Canadian man- President Michele Mordacq, a recent project,
ufacturer of wireless monitoring gear for large a prototype wireless inventory-control system,
bottling plants. To help their clients reduce involved single-point sensors in a custom
breakage during production, Sensor Wireless arrangement that fits on a shelving unit in a
needed a custom force sensor integrated into grocery store. When a shelf becomes empty,
its system which would determine forces ap- the system sends e-mails to company person-
plied to bottles by production line rails, robotic nel listing items that need restocking.
grippers, and adjacent bottles. ”From all the available force-sensing tech-
Once Sensor Wireless customers receive nologies, we selected the FlexiForce as the best
an order, they consult with Sensor Wireless, combination of durability, price, and accuracy,”
which replicates the bottle in question and then says Mordacq. “In questioning different sensor
wraps a sensor around the form. The sensor is
combined with a wireless transmitter by Sen-
sor Wireless and is placed around the bottle,
explains Director of Production and R&D Tom
MacDonald. The proprietary electronics that
enable wireless capability go inside the bottle.
Readings of sidewall forces on the test bottle
transmit from the FlexiForce sensor through an
RF signal to a Palm handheld, so line operators
can see the forces in real time.
Before a custom FlexiForce sensor was devel-
oped for their application, a lot of line adjust-
ments entailed workers “guessing-and-check-
ing,” a difficult way to find problems, notes A FlexiForce thin-film sensor wrapped
MacDonald. “But now,” he says, “an operator around a test “bottle” captures sidewall
just needs to isolate a section of line and run forces exerted on the form. Internal elec-
the test bottle through it anywhere from five tronics send this data wirelessly to a Palm
to 10 times to get a force profile. The operator handheld, letting line operators see the ef-
repeats this process for the whole line, quickly fects of their adjustments in real time.

TekScanFinal.indd 7 4/6/09 3:40:54 PM


Tekscan
manufacturers, we liked the availability of an
off-the-shelf, single-point sensor because we
could easily purchase a few and then build test
samples to see if a system would work. For the
inventory equipment, highly accurate devices
such as medical scales cost too much, and that
level of accuracy was unnecessary anyway. As
long as measurements lay within a few ounces,
it was good enough. Load cells proved too big
because they interfered with system operation.”
Mordacq says the thin-film sensors can also
provide users a way to reduce costs such as
maintenance because the devices let compa-
nies remotely monitor equipment in the field The prototype Real Time Wireless Inventory
and take corrective action earlier. It’s common Reporting system developed by SSI Wireless
to send out technicians to measure pressure, uses force sensors from Tekscan to deter-
temperature, motor turns, and the like to diag- mine when shelves need restocking.
nose equipment problems, Mordacq explains.
This process is costly and time-consuming.
So SSI Wireless is combining FlexiForce sen- unfamiliar disciplines. Mechanical engineers,
sors with electronics to build a device that will for example, must increasingly deal with differ-
provide a remote view for diagnostics. Tekscan ent fields, such as electronics.
worked with the firm during the effort to help “Tekscan partnered with us to help turn its
iron out development issues. Economical Load & Force (ELF) system for
Mordacq also says the capability to interact force measurement into a wireless device,” says
with a force-sensor manufacturer with strategic Mordacq. “We brought in our hardware and
technological partners is important because software experience in wireless communica-
this arrangement can help designers cope with tions and network protocols as well as experi-

Biggest challenges
A WIDE RANGE OF FORCE-SENSING technol- orders, whether they are buying a single sensor
ogies is available, making it difficult to select or millions of sensors. What’s more, designers
the best one. Research from MACHINE DESIGN expect timely delivery of sensors.
magazine’s “2008 Sensors Market Overview Companies that need help in selecting and
Report” lists the biggest challenges designers integrating standard or custom sensors into
face when dealing with a sensor manufacturer. their solutions can work closely with the Tek-
Topping the list is lack of technical assistance. scan technical team throughout the design pro-
When designers have technical questions, cess. As Mark Goldstein, Ph.D., a member of
they want to speak with application engineers the research team that founded MammaCare®,
who understand their processes and can says, “Work is spectacular, and more exception-
quickly address their questions. They also want al than I thought it would be. The sensors work
to collaborate with a company that sells qual- great. They can detect the slightest pressure
ity products and can efficiently handle their accurately. It is way beyond my expectations.”

TekScanFinal.indd 8 4/6/09 3:40:55 PM


Produced by Machine Design Custom Media

ence in the development of Windows desktop Turn a laptop into a


applications. Our two companies continue force-measurement system
to work together on other solutions, a recent
example coming from the aforementioned wire- IN ADDITION TO THE WIRED version shown
less shelf-inventory system.” here, Tekscan’s wireless, inexpensive Economi-
A quick turnaround on custom devices along cal Load & Force (ELF) system provides a USB-
with a sensor manufacturer that knows OEM powered Hub, a battery-operated transmitter,
processes inside-out were factors important three sensors (one in each of the available
to Cervitrol, a Swedish engineering firm that force ranges), and software that turns a laptop
helps companies in the design of new solu- or PC into a force-measurement instrument.
tions. A recent project involved the design The wireless system can capture and store
of an instrument for measuring pressures force data from an
between a steel and rubber plate in commer- event up to 200 feet
cial printing equipment. The instrument lets away. Key software
operators see forces in real time to quickly and features include ASCII
easily adjust the machinery. sis
output to data-analysis
”We had already used the standard flexible me
software, real-time
sensor in other jobs and product trials in the re,
data capture,
past, so we were familiar with its large dynamic and movie e re-
range and excellent linearity and accuracy,” cording and
says Thomas Eisner, design engineer. “But the saving.
instrument design,” he continues, “required
our working closely with the manufacturer. The
design needed a much smaller sensing area
than the standard sensor provides, so it was
necessary to ensure such a small area could, The Economical Load & Force (ELF) system
in fact, detect force. The application involved a from Tekscan gives users an inexpensive,
load range of about 10 to 100 psi and a long pre-built way to try out a force-measurement
surface requiring an even pressure distribution system. Wireless systems are also available.
through a line along the surface. An eight-week
turnaround on the custom sensor and good
advice from the manufacturer helped smooth works well in end solutions, providing a wide
our product-development processes.” resistance range, high linearity, low drift, and
low power consumption. What’s more, the user-
CONCLUSION friendly, single-cell sensors don’t need complex
Good things come in small packages, as OEMs electronics to achieve an output.
that have adopted thin-film piezoresistive flexible Given these characteristics, OEMs can em-
force sensors (FlexiForce) can attest. Such tech- ploy this technology in a range of applications.
nology, with its very thin and flexible capabilities, They will find that these sensors play a key role
is easy to integrate into a myriad of designs. in developing sleeker, smaller designs. ■
OEMs find that these low-cost, off-the-shelf
sensors provide them an easy and quick way MammaCare® is the registered trademark of the
to prototype products. The durable design also Mammatech Corporation. All rights reserved.
For more information on using thin-film, flexible force sensors in product design, visit www.tekscan.com;
phone 800.248.3669 in the United States or +1.617.464.4500 internationally; or email marketing@tekscan.com.

TekScanFinal.indd 9 4/6/09 3:40:56 PM

You might also like