6000 60

Pressure drop in duct entry for scrubber

Q 360000 M3/ hr 100 m3 / Sec

D Inlet Diameter of Duct ( clear I.D. In mtr )


V velocity Of gas in duct
V1 velocity in gas in the flue duct
V2 velocity of gas in m / Sec after change in section
K1 coefficeint of friction as for expansion
k2 coefficient of friction for contraction
g acceleration due to gravity in m/sec2
ρg1 Average density of gas at 40 OC
ρg2 Average density of gas 40 OC

A Loss inlet in entry in WC (0.65*K2 * V22 / 2*g ) *ρg2

0.365631477 mm water column

B Loss at outlet of duct in WC (0.65*K2 * V22 / 2*g ) *ρg2

5.178715596 mm water column

c Total Loss at inlet and out let considering Dry gas zone

5.544347073 mm water column

D Considering liquid flooding + gas entry loss at Grid + Gas passsing loss at Distributor

15 mm water column

E pressure drop across the packing as per calcualtion

100 mm water column

F Total loss across thae scrubber Maximum

126.0886941 mm water column

Page 1
Sheet1

dd = (4* f * V21 / 2*g* D1)* (ρg)

Page 2
Sheet1

18

1.104 mtr Scrubber inside diameter Ratio inlet to outlet


18 m/sec
18 m/sec 5 D1/ D2 0.2208
5.092297899 m/sec
0.38
0.28
9.81 M / sec2
1.12 Kg / m3
1.12 Kg / m3