You are on page 1of 4

DESIGN CHECK FOR CONNECTION PLATE FOR ISMC150: -

Check the forces on bracket from STAAD output


Forces on brackets : -
Vertical shear forces, Vv = 13.50
Horizontal shear forces, Vh = 0.00
Bending moments ,for DL+LL at support = 0.000

Design of Vertical plate : -


Width ,B1 = 250
Depth ,D1 = 300
Thickness, t1 = 8

Number of vertical legs per brackets, n = 1


Forces & moments on each Plate

Vertical shear forces, V1 = Vv/n = 13.5 / 1 = 13.500


Comp/ Tension forces, F1 = Vh/n = 0 / 1 = 0.000
Eccentricity for horizontal load , eh = 75
Bending moment induced, M1 = [V1 x eh] = 13.5 x 0.075 = 1.01
Maximum bending stress,σb= M1 / ZXX =[M1 / (t x d2/6)] = 8.44
= 1.02 x 10^6 / (8 x 300 ^2 / 6) <
Permissibale bending stress of MS = 165
Hence plate is safe in bending

Maximum shear stress induced ,σs = [ V1 / (t1 x D1) = 5.625


= 13.5 x 10^3 / (8 x 300 ) <
Permisibale shear stress of MS = 100
Hence Plate is safe in shear

Maximum comp/tension stress induced ,σct = [ F1/( t1 x D1 )] = 0.00


= 0 x 10^3 / (8 x 300 ) <
Permissibale Compressive stress of MS = 150

Hence the plate is safe in compression / tension


Maximum deflection (cantilever) = V1 x eh^2 x (2B1 + (B1-eh))/6Esteel x = 0.002
= 13.5 x 10^3 x 75^2 x (2 x 250 + (250- 75) / ( 6 x 2 x 10^6) (8x300 <
Span/325 = 0.923
Hence the bracket is safe in Deflection

CHECK FOR ANCHOR FASTNER (CRACKED) FOR PLATE CONNECTION:-


Data : (FROM HILTI TECHNICAL MANUAL)
Spacing of anchor fastners = 150

Minimum concret edge distance = 75

.HSA CHEMICAL = 16
LENGTH = 140
FOR .HSA CHEMICAL M 16 X 140mm LONG
Design
Parame Recommended Load Permissibale Load
ters
Pullout Strength (Tensile) 8.5 KN 11.9
Shear Strength 17.0 KN 17.4

Reactions :-
VH in
Type of Supports Nature VV in KN
KN
PINNED Err:511 shear Err:511

Nos of bolts reqd = ( bolts reqd ) pull in x + ( bolts reqd ) shear in y

( Fastner reqd ) shear y = VH/ shear strength of bolt


( Fastner reqd ) pull in z = VV / pull out strength of bolt

Total Nos of fastner :-


Type of Supports Vv Vh
Fixed but release 1.59 0.00
Provide fastner 2 2

HENCE PROVIDE 4 Nos .HSA CHEMICAL M16 X 140mm LONG


KN FOS 1.2
KN FOS 1.2
KN - m

mm
mm
mm

KN
KN
mm
KN-m
N/mm2

N/mm2

N/mm2

N/mm2

N/mm2

N/mm2

mm

mm
mm

mm

mm
mm

Permissibale Load

KN
KN

Nature