www.bwtek.com | www.nanoram.com
We are Your Spectroscopy Partner
Global leader with > 10,000 Portable and handheld Raman systems
www.bwtek.com | www.nanoram.com 2
Raman Spectroscopy
Laser
785 nm Excitation
1 photon : 1,000,000
3
www.bwtek.com | www.nanoram.com
Mid-IR NIR reflectance Raman
Mechanism: absorption by Mechanism: absorption by Mechanism: inelastic
fundamental molecular harmonics of fundamental scattering by vibrational,
vibrational modes vibrational modes of X-H bonds rotational, low frequency
(e.g., N-H, O-H) molecular modes.
Molecular Specificity: high
Molecular Specificity: low Molecular Specificity: high
Signal Strength: strong
Signal Strength: weak Signal Strength: weak
Energy: 600-4000 cm-1
Energy: 4000-12,500 cm-1 Energy: 176-3200 cm-1
Sampling: direct material
contact required, glass and Sampling: non-contact, but Sampling: container
water appear opaque; can close proximity to material interference is mitigated by
rarely see through container required (<5 mm) accessories
materials
Hardware: longer probes Hardware: CCD detection;
Hardware: probes extremely possible (meters); quartz optics; quartz optics; long probes
expensive, and short in length, dispersive, interferometry common (kilometers in some
size and weight common cases)
4
www.bwtek.com | www.nanoram.com
Technical Specifications
NanoRam
BWS455
Detector TE Cooled linear CCD Array
Excitation 785nm ± 0.5nm, Stability <0.5cm-1, Linewidth <2.0cm-1
mW tunable from 0 mW to 300 mW
Laser Power
0 to 100% in 10% increments
Control
Range / 176cm-1 to 2900cm-1
Resolution ~ 9.0 cm-1 @ 785nm
Display High Visibility OLED touch screen, 3.7" size
Barcode Reader 1D and 2D barcodes
Data Formats .txt, .csv, .spc
DC Power 12V DC at 6.6 Amps
Battery Rechargeable Li-ion Battery, > 5 hours operation
PC Software NanoRam ID
Computer
USB 2.0, Wifi
Interface
5
www.bwtek.com | www.nanoram.com
NanoRam
Raman Technology
Optimal excitation
wavelength of 785nm to
reduce fluorescence
www.bwtek.com | www.nanoram.com
NanoRam
Innovations
State of the art laser and
cooled sensor technology
increases sensitivity
7
www.bwtek.com | www.nanoram.com
NanoRam
Lean Material Lifecycle
Incoming non-destructive
testing of Raw Materials
Reducing Waste in the
Dispensing Suite
Plastic Packaging
Identification
At line identification of
intermediates
Final product identification
Substandard, Adulterants, and Counterfeit Deterrent
8
www.bwtek.com | www.nanoram.com
NanoRam
Ease of Use
No sample preparation
required
Scan through:
Polyethylene Bags
Borosilicate Glass
Vials
Disposable Pipette
Touch Screen allows for
quick documentation of
sample information
9
www.bwtek.com | www.nanoram.com
NanoRam
Ease of Use
Performance Qualification
using polystyrene takes less
than one minute
Wireless reporting for
reduced documentation lead
time
Remote Administration to
reduce unit down time
Clear Pass/ Fail results
Attachments provide laser
safety with built in interlock
10
www.bwtek.com | www.nanoram.com
NanoRam
Good Documentation Practices
Fully Traceable results with:
Time/ Date Stamps
User
System Presets
Etc.
www.bwtek.com | www.nanoram.com
NanoRam
Technical Support
IQOQPQ Services
Execution
Validation Documentation
SOP Templates
Admin
Developer
General User Training
On-site method development,
training and other support services
available
12
www.bwtek.com | www.nanoram.com
NanoRam
Regulatory Compliance
Supports CFR21 Part 11 Electronic
Records and Signature Protocols
Supports CFR21 Part 1040.10
Performance Standards for Light
Emitting Products
Complies with USP<1120> and EP
Ch.2.2.48 guidelines for Raman
spectroscopy
ASTM E1840 Raman Shift Standards
for spectrometer calibrations
13
www.bwtek.com | www.nanoram.com
NanoRam
Warranty Programs
One year factory
warranty comes standard
Extended warranty
programs of 2 or 3 years
can be additionally
purchased
All warranties can be
combined with calibration
service