You are on page 1of 3
libration Services ZX _wesldatty tis) acne Colona CaBhatt? ==) ABHATH weicnts & MEASURINGLAB HAVE OA. P.0.B Say re eg oatmeal) LIE ali Hay EAE ou eae asind Oasis Residence Building, Opposite of Emirates Ges, ind. Area 2, Shed NotS, Al Quesis, beta “Tol: +074 4 2580010, Fax: +971 4 2580050, Mob.: +871 60 4811251, Gem: +871 50 2214408 Email: sales@ebhathuae.com, Website: www.calibretion.2e CALIBRATION CERTIFICATE AUTHORIZED & SIGNATORIES Ariethel Tanteo: Calibrated by GeriicateNo. > ADLOOSDAE Pose Tres Date oftssue elena Caloration Date 2 Mens Job No. ce 1406 Calibration Due Date: 13Jen-19 Calbrated at Laborato Received Dato 1 Melena8 [customer oerars Customer + VEEPEE TRADING Lic Address Dubai — United Arab Emirates [inet ine Catteration woo pera instrument © Insulation Testor Tange + teferto calibration resuk Manufacturer + HIOKI Resolution: refer to calibration resut Mode! No. = iRaD56 Accuracy + refer to coloration result Serial No. + 140503020 No: — ENVIRONMENTAL CONDITIONS I ‘Ambient Temperature; 242°C fa stve Humidity: 56.3 RH METHOD OF CALIBRATION 1, Calibration Procedure: WI/ABHATH-EO2, Wi/ABHATH-EOT 2. Reference Sandari/Gudlne? tURANET eg 1593.0 STANDARD EQUIPMENT USED Insulation Tester Calibration Box 0126941 [07-Aug-18 ‘MT calbration doe in Tunis ard are raceabl to National inertial standard as pared ts SOUEG THRE cor Pe relront reiements of 03001 Standards when acti asthe supple rowdigeairtion reat RESULTS OF CALIBRATION. {- Tie genie Exinsted Usain bees wi he rsals elcid ae cnldess malo 9990 Come Saas GS 2_ The rests of calitation{s given in te ettachedCalivation Daa Shoat). [Petters —_] The calibration interval should bo dntecninod acl on eats OOOO 2. The wer should determine th uit ofthe fastumen fr intended ee 3. The resis seed i this erica lt oly othe tem calrated 4 The item was rectved in good eon. 5. The gen measured values ate average of readings. het cange zee ti ton noown ‘he leboratory eocreton rumen of he Dual Ace angrers in rset ssren Aeden Cnsonss Fe oe oe a Reegheon fl except uth th pr won permission of ABMATH Wht & eamrng Lat & = QL cuales tight pctine Cylons ‘abhath? Lei\ ABHATH weicnts a measurinG Lap \ PS SUL Tents alaR Tahont csp tL uggs endanpay e ananen P.0.Box: 48402, Behind Oasis Residence Building, Opposite of Emirates Gas, Ind. Area 2, Shed No:6, Al ‘Qusais, Dubai Tels: +871 4 2580010, Fax: +971 4 2580060, Mob.: +971 50 4811251, Gem: +971 50 2214409 Email: sales@abhathuaa.com, Website: vww.celibration.ae foe ~ CALIBRATION DATA 'ADL-O0S9-i8 Insulation Tester 140503020 Page Calibration Date Calibration Due Date est Volage: 0 V H1a0% of rd) Resolutions 091 Ma |" 20.000wa| 985 ma} s26mn]z 0400 ma] O01 Ma 2.08 (ae = 48.0% ofa) oma |“30000ya| 965 wa] soo was soo mal ~oama} ar sv 18.0% of rd) [Resolution: ~o.1M® | 20.000Ma/ 995ma} 996ma] x 0400 mo] 001 mo 2.08 3(8.0 % of da) sma | s0000mal seswa| s0mals 800 wa] aime 20% [Tes Volige: 250 V 0.09 oF rg) SE 200 (cu 18.0% of eg) ja cima | 10000 wa| 9925 ma| 300ma[s aon wa| 045 ma 200 rest Vonuge: _ soo ¥ (0.03% of rig) Resolution: “0.01 M_[ 40.000 ma] 995 ma], 000%] + 0400 ma] aos wo 2.00 i 6.0% oF de) cima | 10000 wa] 999Ma]i00Ma]= 400 wa] oa mo 207 48.056 of re) | ___ma_| noo we | sea | sooo wa] = ano wal twa | amo] [Test Volts ev 16.0% of da) [Resolaion: “oor ma |“ io.000Ma| 985 ma] 1000 wa] = 0400 ma] O05 Ma 2.00 16.0 %6 oF re) ima | 30000Ma[999mn| s00Ma]s 400 mal oama 208 318.0% of de) [a twa [10000 ma} 999 ma 1) 2.00 ‘Abhath not liable for any demas the laboratory accrediaion requirements ofthe Dubai Acerediaion Conter i wi aes ae fiz putlaettg Obj gS _pcidve Clos! “abhath? ABHATH weicrs ameasure tas \ 222 SAUL Tans o8s tol h AVN £ Toke ¥e di qatisanal Aig Male Ua a cl LYE yeaa daly ha Ut AE age F.0.Box: 48402, Behind Oasis Residence Building, Opposite of Emirates Gas, Ind. Aros 2, Shed No:6, Al Qusais, Oust Tel:: +871 4 2580010, Fax: +971 4 2580060, Mob.: +971 50 4811251, Gsm: +971 50 2214400 Email: sales@abhathusa.com,Websile: www.calibration.ce CALIBRATION DATA + ADL-O0SD48 3or3 + Insulation Tester ation Date 14Jan-18, Calibration Due Date 33Jan-19 FUNCTION TESTED AC Voltage @ 50 Hz Range 20V 712.3 % ofrdg +8 des) Resoktions: ov | ano a2v zum7v | 22v 035 3780 378 = 86 v | oov 0.08 Rane oo 0 323 % of rig + dats) Resoltions: 1 20 + 1766 V ov 036 380. + 000 V ov 052 DC Voltage = aw #13 Kofrdg +4 dgts) Resolutions o.001v_| 04200 V av = oo v | o0ov 036 3.7800 38V, #005 v | ecov [one 72113 8 of rdg +4 dts) e ay | a200v a2V = 009 v_| 000v a4 Resohtions _001v | 37800 w73V =os3v | oov 005 213 % of eg 4 gts] Range ov | @00v a2 #095 V | oav 034 IResohtions av | 37800 378 2 sav | dav 005 2113 %oFrde+édets)_- Range ov | a200v 20 + 746 V ov 044 IResluiow —_1v | S800 swov | osev [ov 030 | *** END OF CERTIFICATE *** ‘Abhath not abi for any dar ‘he leboretory accreditaion requirements ofthe Dubal Acerediation Center

You might also like