%NUCON TECHNICAL SPECIFICATIONS
GRLen mae) WANE
1 | Size mm 600x200
[2 [Thickness mm 75,100,125, 150, 200 & 230
3 | Size Tolerance mm 2 (4h)
4 | Compressive Strength Nima 335
5 | Oven dry density Kgima 550-650
6 | Fire Resistance Hrs 4(For 200mm thick wall)
7 | Thermal Conductivity Kwik 0.16
8 | Sound Reduction Db 37-42,
9 | Modulus of Elasticity Mpa | 2040 —
10 | Thormal Resistance (R Value) Me0KWw | 0.46
11 | Dry Shrinkage % 0.04
12 | Sound Transmission Class Rating | Db 44
N
5
Games)
* Specifications as per IS standards (IS 2185 part
)) Grade Ml
NUN Melerg
1 | Size (LxHxB) 600mm x 200mm x 75mm to 230mm ‘225mm x 100mm x75mm
2_ | Precision In Size Variation 2.00 (+/+) ram ae Variation 2.15 (+i)
3 | Compressive Strength 3.5 - 4.5N/mma(As per IS:2185 part Ill) _ 25-30 Beate)
4 | Dry Dens | 550-650 kgima(Oven dry) 31800 kgimg
5_| Fire Resistance 2 10 6 hours depending on thickness 2 Hours
6 | Sound Reduction index1 (a8) 45 for 200 mm thick wall 550 for 230 mm thick wall
7_| Thermal Condvetivity(Kw-miC) | 0.16 2 : 081
@ | Mortar Consumption M3 with 1:8 | 0.5 bag of cement 1.35 bag of coment
@ | Construction Time per mason 30 Sqm_ __ Bie z 20 Sam
10 | Chemical composition |_Fly ash used around 70% eacts with binders(lime and cement) to form Nucon Eiorescence. ae tes Ta Salat ete.
11_| Finishing Gan be directly cut or shapedi/sculptured as required. Not possible
12 _| Contribution to carpet area 35% No Contribution
13 _| Cost benefit factor ‘Savings up to 24% in structural cost Gue to reduction of dead load (Subject to projet design.) No cost benef
14_[ Energy saving No Energy Saving
Up to 80% of Air-conditioning Load reduction.ISO 9001 : 2015 Ce:
Greenway Building Materials India Private Ltd.,
1-200, Paritala (V) | Kanchikacherla Krishna (Dist.,) | A.P. - 521 180
e mail : sales@nuconblocks.com, info@nuconblocks.com
contact : +91 888 66 77 501/509/510 web: www.nuconblocks.com
The only AAC Block with mark in South India